Description
Supply of 1 m of antenna cable for the SHIFT6m modular smartphone. Provision of antenna cable. Phone assembly and annual use are represented in the corresponding higher-level inventories.
Materials
Reference product antenna cable GLO
Stable dataset identity
antenna-cable-supply
1.0.0Published inventory
Process description and catalog context. View scientific metadata
Supply of 1 m of antenna cable for the SHIFT6m modular smartphone. Provision of antenna cable. Phone assembly and annual use are represented in the corresponding higher-level inventories.
Classification, keywords, bookmarks and download counts.
Classification path: Materials
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
https://data.mendeley.com/datasets/w3gyzc4x5s/1; lci-shift6m_20022025.zip; process UUID cbfe3c50-ea0a-451d-8157-c88e9918a738; SHA-256 ba461e3e83a5d50ce9d528b23e5f3848ff47693ba5aa856246f1ac934366f3e3
Inventory changes relative to source: Modified inventory
The original ecoinvent 3.8 suppliers are replaced by ecoinvent 3.12 suppliers. The adapted phone supply chain also records the excluded defective inputs and the explicit PMMA lens-cover proxy.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per meter, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-16 10:58 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
antenna cable supply
GLO
|
antenna cable
|
1
|
meter | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
market for extrusion, plastic pipes
GLO
|
extrusion, plastic pipes
|
0.03
|
kilogram |
3.5695e-05
mol H+-Eq / meter
0.2% of total
0.00869461
kg CO2-Eq / meter
3.2% of total
0.0235756
CTUe / meter
1.3% of total
4.5100e-06
kg P-Eq / meter
1.2% of total
4.9513e-06
kg N-Eq / meter
1.4% of total
4.7853e-05
mol N-Eq / meter
1.3% of total
1.1338e-11
CTUh / meter
5.1% of total
5.5873e-11
CTUh / meter
0.6% of total
0.00651325
kBq U235-Eq / meter
9.0% of total
0.166765
dimensionless / meter
11.9% of total
2.0768e-10
kg CFC-11-Eq / meter
3.2% of total
2.8285e-10
disease incidence / meter
1.3% of total
2.0072e-05
kg NMVOC-Eq / meter
1.0% of total
0.159398
MJ, net calorific value / meter
3.1% of total
1.6230e-08
kg Sb-Eq / meter
0.2% of total
0.00565833
m3 world Eq deprived / meter
1.0% of total
BAFU:2025
|
|
|
market for rolling mill
GLO
|
rolling mill
|
1.77e-12
|
unit |
7.1974e-10
mol H+-Eq / meter
0.0% of total
1.2919e-07
kg CO2-Eq / meter
0.0% of total
4.8800e-07
CTUe / meter
0.0% of total
7.6440e-11
kg P-Eq / meter
0.0% of total
1.2340e-10
kg N-Eq / meter
0.0% of total
2.2541e-09
mol N-Eq / meter
0.0% of total
1.9115e-16
CTUh / meter
0.0% of total
5.6894e-15
CTUh / meter
0.0% of total
4.1146e-08
kBq U235-Eq / meter
0.0% of total
5.9980e-06
dimensionless / meter
0.0% of total
2.4752e-15
kg CFC-11-Eq / meter
0.0% of total
8.9750e-15
disease incidence / meter
0.0% of total
4.3342e-10
kg NMVOC-Eq / meter
0.0% of total
1.4990e-06
MJ, net calorific value / meter
0.0% of total
1.2481e-12
kg Sb-Eq / meter
0.0% of total
6.2226e-07
m3 world Eq deprived / meter
0.0% of total
BAFU:2025
|
|
|
market for wire drawing, copper
GLO
|
wire drawing, copper
|
0.02
|
kilogram |
0.000105992
mol H+-Eq / meter
0.7% of total
0.00580653
kg CO2-Eq / meter
2.2% of total
0.0419866
CTUe / meter
2.3% of total
3.4095e-05
kg P-Eq / meter
9.2% of total
8.8743e-06
kg N-Eq / meter
2.5% of total
9.7968e-05
mol N-Eq / meter
2.6% of total
1.6339e-11
CTUh / meter
7.3% of total
1.2341e-09
CTUh / meter
13.1% of total
0.00293519
kBq U235-Eq / meter
4.1% of total
0.0357897
dimensionless / meter
2.6% of total
1.4527e-10
kg CFC-11-Eq / meter
2.2% of total
2.8343e-10
disease incidence / meter
1.3% of total
4.2823e-05
kg NMVOC-Eq / meter
2.2% of total
0.0990808
MJ, net calorific value / meter
1.9% of total
7.0828e-07
kg Sb-Eq / meter
8.4% of total
0.00247889
m3 world Eq deprived / meter
0.4% of total
BAFU:2025
|
|
|
market for polyethylene, high density, granulate
KR
|
polyethylene, high density, granulate
|
0.03
|
kilogram |
0.000184548
mol H+-Eq / meter
1.3% of total
0.077634
kg CO2-Eq / meter
28.7% of total
0.462529
CTUe / meter
25.2% of total
4.3191e-06
kg P-Eq / meter
1.2% of total
4.1121e-05
kg N-Eq / meter
11.4% of total
0.000450458
mol N-Eq / meter
12.1% of total
1.1117e-11
CTUh / meter
5.0% of total
2.9402e-10
CTUh / meter
3.1% of total
0.00279172
kBq U235-Eq / meter
3.9% of total
0.032137
dimensionless / meter
2.3% of total
2.1779e-09
kg CFC-11-Eq / meter
33.5% of total
2.3218e-09
disease incidence / meter
10.5% of total
0.000196867
kg NMVOC-Eq / meter
10.2% of total
2.40153
MJ, net calorific value / meter
46.8% of total
1.1732e-07
kg Sb-Eq / meter
1.4% of total
0.450747
m3 world Eq deprived / meter
76.4% of total
BAFU:2025
|
|
|
market for copper, cathode
GLO
|
copper, cathode
|
0.02
|
kilogram |
0.0141191
mol H+-Eq / meter
96.1% of total
0.132324
kg CO2-Eq / meter
49.0% of total
1.14177
CTUe / meter
62.3% of total
0.000316155
kg P-Eq / meter
85.6% of total
0.000251579
kg N-Eq / meter
69.5% of total
0.0025588
mol N-Eq / meter
68.6% of total
1.3959e-10
CTUh / meter
62.3% of total
5.4846e-09
CTUh / meter
58.1% of total
0.0461165
kBq U235-Eq / meter
64.1% of total
1.04175
dimensionless / meter
74.5% of total
2.8510e-09
kg CFC-11-Eq / meter
43.8% of total
1.6726e-08
disease incidence / meter
75.9% of total
0.00148161
kg NMVOC-Eq / meter
76.9% of total
1.73751
MJ, net calorific value / meter
33.8% of total
1.3530e-06
kg Sb-Eq / meter
16.0% of total
0.118211
m3 world Eq deprived / meter
20.0% of total
BAFU:2025
|
|
|
market for glass fibre
GLO
|
glass fibre
|
0.02
|
kilogram |
0.000254345
mol H+-Eq / meter
1.7% of total
0.0455851
kg CO2-Eq / meter
16.9% of total
0.163102
CTUe / meter
8.9% of total
1.0362e-05
kg P-Eq / meter
2.8% of total
5.5520e-05
kg N-Eq / meter
15.3% of total
0.000576703
mol N-Eq / meter
15.5% of total
4.5792e-11
CTUh / meter
20.4% of total
2.3714e-09
CTUh / meter
25.1% of total
0.0136378
kBq U235-Eq / meter
18.9% of total
0.122797
dimensionless / meter
8.8% of total
1.1289e-09
kg CFC-11-Eq / meter
17.3% of total
2.4325e-09
disease incidence / meter
11.0% of total
0.000184258
kg NMVOC-Eq / meter
9.6% of total
0.736356
MJ, net calorific value / meter
14.3% of total
6.2799e-06
kg Sb-Eq / meter
74.1% of total
0.0130887
m3 world Eq deprived / meter
2.2% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
2 CLIC nodes and 6 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Choose software and background database settings once you open the Basket page.
| File | Downloads | Action |
|---|---|---|
| ecoinvent_3_12_cutoff.xlsx Primary | 0 | Log in to download |
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
Initial CLIC SHIFT6m adaptation. Specific phone design and source repair/lifetime scenarios; not a generic modern smartphone. Phone ready-for-sale and annual service are different functional…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.0 | 2026-11-16 | Initial CLIC SHIFT6m adaptation. Specific phone design and source repair/lifetime scenarios; not a generic modern smartphone. Phone ready-for-sale and annual service are different functional outputs. Prior climate checks are about 15% below the publication for phone production and 7–13% below annual service; the 2.5-year case is outside the reported interval. No exact reproduction claim. Preserve all source-model qualifications and uncertainty distributions. | Current view |
Initial CLIC SHIFT6m adaptation. Specific phone design and source repair/lifetime scenarios; not a generic modern smartphone. Phone ready-for-sale and annual service are different functional outputs. Prior climate checks are about 15% below the publication for phone production and 7–13% below annual service; the 2.5-year case is outside the reported interval. No exact reproduction claim. Preserve all source-model qualifications and uncertainty distributions.
Publication route
A curator validated the batch manifest and an editor authorized publication. This route does not imply that CLIC's current structured community-review checklist was completed.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content