Description
Production of aspiration system. The reference flow is one unit of aspiration system. It is a supporting equipment or consumable inventory for the laboratory waste-RAM recovery route.
Waste
Reference product aspiration system GLO
Stable dataset identity
aspiration-system-production
1.0.0Published inventory
Process description and catalog context. View scientific metadata
Production of aspiration system. The reference flow is one unit of aspiration system. It is a supporting equipment or consumable inventory for the laboratory waste-RAM recovery route.
Classification, keywords, bookmarks and download counts.
Classification path: Waste
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
https://doi.org/10.1016/j.jclepro.2025.147016; https://doi.org/10.5281/zenodo.17348137; LCI_equipment!A66; SHA-256 cda3a9b590afe2e570908048c1e2999f1a9ba098f0045f6312c7074344674c24
Inventory changes relative to source: Modified inventory
The published ecoinvent 3.8 APOS background is replaced by ecoinvent 3.12 cut-off. The compilation also makes the documented laboratory correction and alternative allocation views explicit; it is not a reproduction of the original APOS model.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-16 10:57 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
aspiration system production
GLO
|
aspiration system
|
1
|
unit | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
reinforcing steel production
RoW
|
reinforcing steel
|
25.24
|
kilogram |
0.102045
mol H+-Eq / unit
0.8% of total
36.8346
kg CO2-Eq / unit
2.5% of total
97.1756
CTUe / unit
1.5% of total
0.0142118
kg P-Eq / unit
0.4% of total
0.0244575
kg N-Eq / unit
1.7% of total
0.256742
mol N-Eq / unit
1.7% of total
1.0911e-07
CTUh / unit
1.8% of total
1.1152e-06
CTUh / unit
0.6% of total
8.86211
kBq U235-Eq / unit
2.9% of total
105.196
dimensionless / unit
2.1% of total
4.4237e-07
kg CFC-11-Eq / unit
1.9% of total
2.2639e-06
disease incidence / unit
2.1% of total
0.111314
kg NMVOC-Eq / unit
1.9% of total
365.716
MJ, net calorific value / unit
2.6% of total
0.000245669
kg Sb-Eq / unit
0.5% of total
8.10631
m3 world Eq deprived / unit
2.1% of total
BAFU:2025
|
|
|
smelting of copper concentrate, sulfide ore
RoW
|
copper, anode
|
8.41
|
kilogram |
4.1947
mol H+-Eq / unit
31.2% of total
23.6589
kg CO2-Eq / unit
1.6% of total
1335.19
CTUe / unit
20.0% of total
1.4814
kg P-Eq / unit
42.1% of total
0.235615
kg N-Eq / unit
16.5% of total
2.6661
mol N-Eq / unit
17.2% of total
7.5601e-07
CTUh / unit
12.6% of total
7.1432e-05
CTUh / unit
38.1% of total
6.92691
kBq U235-Eq / unit
2.3% of total
582.648
dimensionless / unit
11.7% of total
5.6052e-07
kg CFC-11-Eq / unit
2.4% of total
7.9240e-06
disease incidence / unit
7.4% of total
0.734388
kg NMVOC-Eq / unit
12.5% of total
317.433
MJ, net calorific value / unit
2.2% of total
0.0169534
kg Sb-Eq / unit
37.2% of total
25.3537
m3 world Eq deprived / unit
6.6% of total
BAFU:2025
|
|
|
treatment of aluminium scrap, new, at refiner
RoW
|
aluminium, cast alloy
|
4.21
|
kilogram |
0.000394338
mol H+-Eq / unit
0.0% of total
0.0935395
kg CO2-Eq / unit
0.0% of total
0.263159
CTUe / unit
0.0% of total
1.6061e-05
kg P-Eq / unit
0.0% of total
0.000157321
kg N-Eq / unit
0.0% of total
0.00162722
mol N-Eq / unit
0.0% of total
4.4856e-11
CTUh / unit
0.0% of total
7.9602e-10
CTUh / unit
0.0% of total
0.0229739
kBq U235-Eq / unit
0.0% of total
0.729816
dimensionless / unit
0.0% of total
3.3002e-09
kg CFC-11-Eq / unit
0.0% of total
3.0897e-09
disease incidence / unit
0.0% of total
0.000573049
kg NMVOC-Eq / unit
0.0% of total
1.42394
MJ, net calorific value / unit
0.0% of total
2.1776e-07
kg Sb-Eq / unit
0.0% of total
0.100119
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for polyvinyl chloride, suspension polymerised
RoW
|
polyvinyl chloride, suspension polymerised
|
4.21
|
kilogram |
0.0237949
mol H+-Eq / unit
0.2% of total
9.50132
kg CO2-Eq / unit
0.6% of total
97.9041
CTUe / unit
1.5% of total
0.000589773
kg P-Eq / unit
0.0% of total
0.00493515
kg N-Eq / unit
0.3% of total
0.0543682
mol N-Eq / unit
0.4% of total
2.9780e-09
CTUh / unit
0.0% of total
1.5979e-07
CTUh / unit
0.1% of total
0.632266
kBq U235-Eq / unit
0.2% of total
8.06083
dimensionless / unit
0.2% of total
3.8888e-06
kg CFC-11-Eq / unit
16.4% of total
2.3652e-07
disease incidence / unit
0.2% of total
0.0191891
kg NMVOC-Eq / unit
0.3% of total
183.422
MJ, net calorific value / unit
1.3% of total
6.9132e-05
kg Sb-Eq / unit
0.2% of total
0.817316
m3 world Eq deprived / unit
0.2% of total
BAFU:2025
|
|
|
reinforcing steel production
RoW
|
reinforcing steel
|
20.93
|
kilogram |
0.0846376
mol H+-Eq / unit
0.6% of total
30.5513
kg CO2-Eq / unit
2.1% of total
80.5991
CTUe / unit
1.2% of total
0.0117875
kg P-Eq / unit
0.3% of total
0.0202854
kg N-Eq / unit
1.4% of total
0.212946
mol N-Eq / unit
1.4% of total
9.0501e-08
CTUh / unit
1.5% of total
9.2497e-07
CTUh / unit
0.5% of total
7.35039
kBq U235-Eq / unit
2.4% of total
87.2517
dimensionless / unit
1.8% of total
3.6691e-07
kg CFC-11-Eq / unit
1.5% of total
1.8777e-06
disease incidence / unit
1.8% of total
0.0923261
kg NMVOC-Eq / unit
1.6% of total
303.331
MJ, net calorific value / unit
2.1% of total
0.000203762
kg Sb-Eq / unit
0.4% of total
6.72351
m3 world Eq deprived / unit
1.8% of total
BAFU:2025
|
|
|
reinforcing steel production
RoW
|
reinforcing steel
|
206.09
|
kilogram |
0.833328
mol H+-Eq / unit
6.2% of total
300.803
kg CO2-Eq / unit
20.3% of total
793.565
CTUe / unit
11.9% of total
0.116058
kg P-Eq / unit
3.3% of total
0.199727
kg N-Eq / unit
14.0% of total
2.09663
mol N-Eq / unit
13.5% of total
8.9106e-07
CTUh / unit
14.8% of total
9.1071e-06
CTUh / unit
4.9% of total
72.3707
kBq U235-Eq / unit
23.6% of total
859.066
dimensionless / unit
17.2% of total
3.6125e-06
kg CFC-11-Eq / unit
15.2% of total
1.8487e-05
disease incidence / unit
17.4% of total
0.909028
kg NMVOC-Eq / unit
15.5% of total
2986.55
MJ, net calorific value / unit
21.1% of total
0.00200621
kg Sb-Eq / unit
4.4% of total
66.1986
m3 world Eq deprived / unit
17.3% of total
BAFU:2025
|
|
|
reinforcing steel production
RoW
|
reinforcing steel
|
115.93
|
kilogram |
0.468746
mol H+-Eq / unit
3.5% of total
169.201
kg CO2-Eq / unit
11.4% of total
446.379
CTUe / unit
6.7% of total
0.0652823
kg P-Eq / unit
1.9% of total
0.112346
kg N-Eq / unit
7.8% of total
1.17935
mol N-Eq / unit
7.6% of total
5.0122e-07
CTUh / unit
8.3% of total
5.1227e-06
CTUh / unit
2.7% of total
40.7084
kBq U235-Eq / unit
13.3% of total
483.223
dimensionless / unit
9.7% of total
2.0320e-06
kg CFC-11-Eq / unit
8.6% of total
1.0399e-05
disease incidence / unit
9.8% of total
0.511327
kg NMVOC-Eq / unit
8.7% of total
1679.93
MJ, net calorific value / unit
11.9% of total
0.00112849
kg Sb-Eq / unit
2.5% of total
37.2366
m3 world Eq deprived / unit
9.7% of total
BAFU:2025
|
|
|
section bar rolling, steel
RoW
|
section bar rolling, steel
|
25.24
|
kilogram |
0.00801907
mol H+-Eq / unit
0.1% of total
4.9423
kg CO2-Eq / unit
0.3% of total
28.8517
CTUe / unit
0.4% of total
0.00138667
kg P-Eq / unit
0.0% of total
0.00179947
kg N-Eq / unit
0.1% of total
0.0175675
mol N-Eq / unit
0.1% of total
4.4286e-09
CTUh / unit
0.1% of total
7.6861e-08
CTUh / unit
0.0% of total
0.970124
kBq U235-Eq / unit
0.3% of total
13.1153
dimensionless / unit
0.3% of total
2.4682e-07
kg CFC-11-Eq / unit
1.0% of total
1.3074e-07
disease incidence / unit
0.1% of total
0.00780758
kg NMVOC-Eq / unit
0.1% of total
34.0913
MJ, net calorific value / unit
0.2% of total
3.5590e-05
kg Sb-Eq / unit
0.1% of total
0.702121
m3 world Eq deprived / unit
0.2% of total
BAFU:2025
|
|
|
wire drawing, copper
RoW
|
wire drawing, copper
|
8.41
|
kilogram |
0.0573381
mol H+-Eq / unit
0.4% of total
3.14113
kg CO2-Eq / unit
0.2% of total
22.7133
CTUe / unit
0.3% of total
0.0184439
kg P-Eq / unit
0.5% of total
0.00480071
kg N-Eq / unit
0.3% of total
0.052997
mol N-Eq / unit
0.3% of total
8.8386e-09
CTUh / unit
0.1% of total
6.6761e-07
CTUh / unit
0.4% of total
1.58784
kBq U235-Eq / unit
0.5% of total
19.361
dimensionless / unit
0.4% of total
7.8588e-08
kg CFC-11-Eq / unit
0.3% of total
1.5333e-07
disease incidence / unit
0.1% of total
0.0231658
kg NMVOC-Eq / unit
0.4% of total
53.5992
MJ, net calorific value / unit
0.4% of total
0.000383155
kg Sb-Eq / unit
0.8% of total
1.34099
m3 world Eq deprived / unit
0.4% of total
BAFU:2025
|
|
|
section bar extrusion, aluminium
RoW
|
section bar extrusion, aluminium
|
4.21
|
kilogram |
0.0084569
mol H+-Eq / unit
0.1% of total
2.99794
kg CO2-Eq / unit
0.2% of total
11.9503
CTUe / unit
0.2% of total
0.00139313
kg P-Eq / unit
0.0% of total
0.00176494
kg N-Eq / unit
0.1% of total
0.0160266
mol N-Eq / unit
0.1% of total
2.4494e-09
CTUh / unit
0.0% of total
2.3997e-08
CTUh / unit
0.0% of total
2.06991
kBq U235-Eq / unit
0.7% of total
29.7826
dimensionless / unit
0.6% of total
7.3833e-08
kg CFC-11-Eq / unit
0.3% of total
6.5879e-08
disease incidence / unit
0.1% of total
0.00578673
kg NMVOC-Eq / unit
0.1% of total
55.3309
MJ, net calorific value / unit
0.4% of total
3.8342e-06
kg Sb-Eq / unit
0.0% of total
4.41846
m3 world Eq deprived / unit
1.2% of total
BAFU:2025
|
|
|
blow moulding
RoW
|
blow moulding
|
4.21
|
kilogram |
0.00984908
mol H+-Eq / unit
0.1% of total
2.71455
kg CO2-Eq / unit
0.2% of total
9.59805
CTUe / unit
0.1% of total
0.00187895
kg P-Eq / unit
0.1% of total
0.00214736
kg N-Eq / unit
0.2% of total
0.0192394
mol N-Eq / unit
0.1% of total
8.2412e-09
CTUh / unit
0.1% of total
2.1910e-08
CTUh / unit
0.0% of total
2.74636
kBq U235-Eq / unit
0.9% of total
96.4976
dimensionless / unit
1.9% of total
8.7865e-08
kg CFC-11-Eq / unit
0.4% of total
1.1843e-07
disease incidence / unit
0.1% of total
0.00682768
kg NMVOC-Eq / unit
0.1% of total
60.1884
MJ, net calorific value / unit
0.4% of total
4.9786e-06
kg Sb-Eq / unit
0.0% of total
3.29544
m3 world Eq deprived / unit
0.9% of total
BAFU:2025
|
|
|
section bar rolling, steel
RoW
|
section bar rolling, steel
|
342.95
|
kilogram |
0.108973
mol H+-Eq / unit
0.8% of total
67.1622
kg CO2-Eq / unit
4.5% of total
392.073
CTUe / unit
5.9% of total
0.0188437
kg P-Eq / unit
0.5% of total
0.0244535
kg N-Eq / unit
1.7% of total
0.238729
mol N-Eq / unit
1.5% of total
6.0181e-08
CTUh / unit
1.0% of total
1.0445e-06
CTUh / unit
0.6% of total
13.1833
kBq U235-Eq / unit
4.3% of total
178.227
dimensionless / unit
3.6% of total
3.3541e-06
kg CFC-11-Eq / unit
14.1% of total
1.7767e-06
disease incidence / unit
1.7% of total
0.106099
kg NMVOC-Eq / unit
1.8% of total
463.275
MJ, net calorific value / unit
3.3% of total
0.000483643
kg Sb-Eq / unit
1.1% of total
9.5413
m3 world Eq deprived / unit
2.5% of total
BAFU:2025
|
|
|
transport, freight, lorry, 16-32 metric ton, diesel, EURO 6
RoW
|
transport, freight, lorry, 16-32 metric ton, diesel, EURO 6
|
38.5
|
ton kilometer |
0.0571358
mol H+-Eq / unit
0.4% of total
10.7535
kg CO2-Eq / unit
0.7% of total
26.2593
CTUe / unit
0.4% of total
0.000782758
kg P-Eq / unit
0.0% of total
0.0251162
kg N-Eq / unit
1.8% of total
0.2725
mol N-Eq / unit
1.8% of total
2.9010e-09
CTUh / unit
0.0% of total
6.6017e-08
CTUh / unit
0.0% of total
1.23469
kBq U235-Eq / unit
0.4% of total
46.5734
dimensionless / unit
0.9% of total
5.6783e-07
kg CFC-11-Eq / unit
2.4% of total
2.8613e-07
disease incidence / unit
0.3% of total
0.0893124
kg NMVOC-Eq / unit
1.5% of total
155.322
MJ, net calorific value / unit
1.1% of total
2.0751e-05
kg Sb-Eq / unit
0.0% of total
9.71089
m3 world Eq deprived / unit
2.5% of total
BAFU:2025
|
|
|
market for steel, low-alloyed
GLO
|
steel, low-alloyed
|
25.24
|
kilogram |
0.157551
mol H+-Eq / unit
1.2% of total
53.9355
kg CO2-Eq / unit
3.6% of total
127.243
CTUe / unit
1.9% of total
0.0210315
kg P-Eq / unit
0.6% of total
0.0364249
kg N-Eq / unit
2.5% of total
0.388689
mol N-Eq / unit
2.5% of total
1.8786e-07
CTUh / unit
3.1% of total
1.2874e-06
CTUh / unit
0.7% of total
9.65756
kBq U235-Eq / unit
3.1% of total
128.958
dimensionless / unit
2.6% of total
5.2057e-07
kg CFC-11-Eq / unit
2.2% of total
3.6741e-06
disease incidence / unit
3.5% of total
0.165995
kg NMVOC-Eq / unit
2.8% of total
473.409
MJ, net calorific value / unit
3.3% of total
0.000476335
kg Sb-Eq / unit
1.0% of total
8.82059
m3 world Eq deprived / unit
2.3% of total
BAFU:2025
|
|
|
treatment of used cable
GLO
|
copper, cathode
|
8.41
|
kilogram |
5.1521
mol H+-Eq / unit
38.4% of total
22.6129
kg CO2-Eq / unit
1.5% of total
1435.01
CTUe / unit
21.4% of total
1.47698
kg P-Eq / unit
42.0% of total
0.23698
kg N-Eq / unit
16.6% of total
2.69718
mol N-Eq / unit
17.4% of total
8.2661e-07
CTUh / unit
13.8% of total
7.8798e-05
CTUh / unit
42.1% of total
7.23334
kBq U235-Eq / unit
2.4% of total
584.273
dimensionless / unit
11.7% of total
5.7191e-07
kg CFC-11-Eq / unit
2.4% of total
8.7973e-06
disease incidence / unit
8.3% of total
0.795165
kg NMVOC-Eq / unit
13.6% of total
311.515
MJ, net calorific value / unit
2.2% of total
0.0170405
kg Sb-Eq / unit
37.4% of total
24.4593
m3 world Eq deprived / unit
6.4% of total
BAFU:2025
|
|
|
treatment of aluminium scrap, new, at remelter
RoW
|
aluminium, wrought alloy
|
4.21
|
kilogram |
0.000394338
mol H+-Eq / unit
0.0% of total
0.0935395
kg CO2-Eq / unit
0.0% of total
0.263159
CTUe / unit
0.0% of total
1.6061e-05
kg P-Eq / unit
0.0% of total
0.000157321
kg N-Eq / unit
0.0% of total
0.00162722
mol N-Eq / unit
0.0% of total
4.4856e-11
CTUh / unit
0.0% of total
7.9602e-10
CTUh / unit
0.0% of total
0.0229739
kBq U235-Eq / unit
0.0% of total
0.729816
dimensionless / unit
0.0% of total
3.3002e-09
kg CFC-11-Eq / unit
0.0% of total
3.0897e-09
disease incidence / unit
0.0% of total
0.000573049
kg NMVOC-Eq / unit
0.0% of total
1.42394
MJ, net calorific value / unit
0.0% of total
2.1776e-07
kg Sb-Eq / unit
0.0% of total
0.100119
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
polyethylene, pellets, recycled to generic markets for LDPE and HDPE
RER
|
polyethylene, high density, granulate
|
4.21
|
kilogram |
0.0226962
mol H+-Eq / unit
0.2% of total
9.54762
kg CO2-Eq / unit
0.6% of total
56.8829
CTUe / unit
0.9% of total
0.000531173
kg P-Eq / unit
0.0% of total
0.00505719
kg N-Eq / unit
0.4% of total
0.0553984
mol N-Eq / unit
0.4% of total
1.3672e-09
CTUh / unit
0.0% of total
3.6159e-08
CTUh / unit
0.0% of total
0.343333
kBq U235-Eq / unit
0.1% of total
3.95229
dimensionless / unit
0.1% of total
2.6785e-07
kg CFC-11-Eq / unit
1.1% of total
2.8555e-07
disease incidence / unit
0.3% of total
0.0242112
kg NMVOC-Eq / unit
0.4% of total
295.346
MJ, net calorific value / unit
2.1% of total
1.4428e-05
kg Sb-Eq / unit
0.0% of total
55.4339
m3 world Eq deprived / unit
14.5% of total
BAFU:2025
|
|
|
market for steel, low-alloyed
GLO
|
steel, low-alloyed
|
342.95
|
kilogram |
2.141
mol H+-Eq / unit
15.9% of total
732.943
kg CO2-Eq / unit
49.5% of total
1729.14
CTUe / unit
25.8% of total
0.285802
kg P-Eq / unit
8.1% of total
0.494987
kg N-Eq / unit
34.6% of total
5.282
mol N-Eq / unit
34.1% of total
2.5528e-06
CTUh / unit
42.5% of total
1.7494e-05
CTUh / unit
9.3% of total
131.239
kBq U235-Eq / unit
42.7% of total
1752.45
dimensionless / unit
35.2% of total
7.0741e-06
kg CFC-11-Eq / unit
29.8% of total
4.9928e-05
disease incidence / unit
46.9% of total
2.25575
kg NMVOC-Eq / unit
38.5% of total
6433.27
MJ, net calorific value / unit
45.4% of total
0.00647303
kg Sb-Eq / unit
14.2% of total
119.865
m3 world Eq deprived / unit
31.4% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
7 CLIC nodes and 13 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Choose software and background database settings once you open the Basket page.
| File | Downloads | Action |
|---|---|---|
| ecoinvent_3_12_cutoff.xlsx Primary | 0 | Log in to download |
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.0 | 2026-11-16 | Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens already include the source 0.769 internal treatment allocation: do not repeat it. Background is 3.12 cut-off, not the source APOS system. Deterministic inventory; no probability distributions added. | Current view |
Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens already include the source 0.769 internal treatment allocation: do not repeat it. Background is 3.12 cut-off, not the source APOS system. Deterministic inventory; no probability distributions added.
Publication route
A curator validated the batch manifest and an editor authorized publication. This route does not imply that CLIC's current structured community-review checklist was completed.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content