Description
Manufacture and modelled retirement of one control and cooling assembly for 16 battery modules.
Lithium-ion batteries
Reference product battery control and cooling system, 16 modules GLO
Stable dataset identity
battery-control-and-cooling-system-production-16-modules
1.0.0Published inventory
Process description and catalog context. View scientific metadata
Manufacture and modelled retirement of one control and cooling assembly for 16 battery modules.
Classification, keywords, bookmarks and download counts.
Classification path: Materials > Batteries > Lithium-ion batteries
Log in to bookmarkSource documentation, background profiles and references.
Other
Supporting sources:
Texas Instruments Incorporated (October 2025, last-updated footer). TIDA-020076 fitted BOM, SLURB87. https://www.ti.com/lit/pdf/SLURB87
Linda Ager‐Wick Ellingsen; Guillaume Majeau‐Bettez; Bhawna Singh; Akhilesh Kumar Srivastava; Lars Ole Valøen; Anders Hammer Strømman (2014; first online 1 November 2013). Life Cycle Assessment of a Lithium‐Ion Battery Vehicle Pack. Journal of Industrial Ecology 18(1), 113–124. https://doi.org/10.1111/jiec.12072
Sanna Wickerts; Rickard Arvidsson; Anders Nordelöf; Magdalena Svanström; Patrik Johansson (2023). Prospective Life Cycle Assessment of Lithium-Sulfur Batteries for Stationary Energy Storage. https://doi.org/10.1021/acssuschemeng.3c00141
Sanna Wickerts; Rickard Arvidsson; Anders Nordelöf; Magdalena Svanström; Patrik Johansson (2024). Correction to “Prospective Life Cycle Assessment of Lithium–Sulfur Batteries for Stationary Energy Storage”. https://doi.org/10.1021/acssuschemeng.4c01782
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-03 09:08 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
battery control and cooling system production, 16 modules
GLO
|
battery control and cooling system, 16 modules
|
1
|
unit | - | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
battery central control and protection unit
|
1
|
unit | - |
2.67134
mol H+-Eq / unit
82.1% of total
101.755
kg CO2-Eq / unit
67.5% of total
752.613
CTUe / unit
80.3% of total
0.370175
kg P-Eq / unit
90.0% of total
0.137074
kg N-Eq / unit
76.2% of total
1.4998
mol N-Eq / unit
80.8% of total
2.0645e-07
CTUh / unit
-69.8% of total
1.0130e-05
CTUh / unit
83.3% of total
24.9753
kBq U235-Eq / unit
45.6% of total
1017.38
dimensionless / unit
96.4% of total
3.7427e-06
kg CFC-11-Eq / unit
81.7% of total
6.5558e-06
disease incidence / unit
67.5% of total
0.663071
kg NMVOC-Eq / unit
112.8% of total
1369.65
MJ, net calorific value / unit
84.8% of total
0.052411
kg Sb-Eq / unit
85.1% of total
906.319
m3 world Eq deprived / unit
58.5% of total
|
|
|
printed circuit board, battery module control, mounted
|
1.12
|
kilogram | - |
0.491353
mol H+-Eq / unit
15.1% of total
36.3701
kg CO2-Eq / unit
24.1% of total
241.423
CTUe / unit
25.7% of total
0.0652258
kg P-Eq / unit
15.9% of total
0.0349648
kg N-Eq / unit
19.4% of total
0.331446
mol N-Eq / unit
17.9% of total
3.7270e-08
CTUh / unit
-12.6% of total
1.4464e-06
CTUh / unit
11.9% of total
8.05197
kBq U235-Eq / unit
14.7% of total
176.207
dimensionless / unit
16.7% of total
2.6438e-06
kg CFC-11-Eq / unit
57.7% of total
1.5355e-06
disease incidence / unit
15.8% of total
0.123028
kg NMVOC-Eq / unit
20.9% of total
493.431
MJ, net calorific value / unit
30.5% of total
0.0091787
kg Sb-Eq / unit
14.9% of total
414.193
m3 world Eq deprived / unit
26.7% of total
|
|
|
cooling system
|
10
|
kilogram | - |
0.250552
mol H+-Eq / unit
7.7% of total
58.321
kg CO2-Eq / unit
38.7% of total
172.746
CTUe / unit
18.4% of total
0.0145487
kg P-Eq / unit
3.5% of total
0.0489019
kg N-Eq / unit
27.2% of total
0.412147
mol N-Eq / unit
22.2% of total
5.7911e-08
CTUh / unit
-19.6% of total
9.2894e-07
CTUh / unit
7.6% of total
28.1199
kBq U235-Eq / unit
51.4% of total
128.153
dimensionless / unit
12.1% of total
1.3851e-06
kg CFC-11-Eq / unit
30.2% of total
2.7309e-06
disease incidence / unit
28.1% of total
0.156892
kg NMVOC-Eq / unit
26.7% of total
909.34
MJ, net calorific value / unit
56.3% of total
6.3515e-05
kg Sb-Eq / unit
0.1% of total
352.461
m3 world Eq deprived / unit
22.8% of total
|
|
|
market for used Li-ion battery
GLO
|
used Li-ion battery
|
-15.61
|
kilogram | - |
-0.159754
mol H+-Eq / unit
-4.9% of total
-45.6878
kg CO2-Eq / unit
-30.3% of total
-229.173
CTUe / unit
-24.4% of total
-0.0387545
kg P-Eq / unit
-9.4% of total
-0.0411322
kg N-Eq / unit
-22.9% of total
-0.387459
mol N-Eq / unit
-20.9% of total
-5.9749e-07
CTUh / unit
202.0% of total
-3.4526e-07
CTUh / unit
-2.8% of total
-6.42274
kBq U235-Eq / unit
-11.7% of total
-266.904
dimensionless / unit
-25.3% of total
-3.1915e-06
kg CFC-11-Eq / unit
-69.7% of total
-1.1065e-06
disease incidence / unit
-11.4% of total
-0.355125
kg NMVOC-Eq / unit
-60.4% of total
-1156.47
MJ, net calorific value / unit
-71.6% of total
-8.0479e-05
kg Sb-Eq / unit
-0.1% of total
-123.807
m3 world Eq deprived / unit
-8.0% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
This battery control and cooling system production, 16 modules reference makes its product and manufacturing boundary explicit. Its supplied inputs include battery central control…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.0 | 2026-11-03 | This battery control and cooling system production, 16 modules reference makes its product and manufacturing boundary explicit. Its supplied inputs include battery central control and protection unit, printed circuit board, battery module control, mounted, cooling system. | Current view |
This battery control and cooling system production, 16 modules reference makes its product and manufacturing boundary explicit. Its supplied inputs include battery central control and protection unit, printed circuit board, battery module control, mounted, cooling system.
The reference retains the documented engineering proxies and allowances; it does not establish a manufacturer-specific grade or measured production line.
Source: https://doi.org/10.1021/acssuschemeng.4c01782.s001, https://doi.org/10.1111/jiec.12072.
Declared foreground licence: CC-BY-NC-4.0. Source publications and external supplier inventories retain their own terms.
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content