Lithium-ion batteries

battery control and cooling system production, 16 modules

Reference product battery control and cooling system, 16 modules GLO

Published Version 1.0.0 Not assessed Latest published

Stable dataset identity battery-control-and-cooling-system-production-16-modules

Unit
unit
Reuse license
CC BY-NC 4.0
Published
2026-11-03
Version
1.0.0
Technology maturity
Not assessed

Published inventory

Overview

Process description and catalog context. View scientific metadata

Description

Manufacture and modelled retirement of one control and cooling assembly for 16 battery modules.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Lithium-ion batteries (materials/batteries/li-ion)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0

Classification path: Materials > Batteries > Lithium-ion batteries

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Other

Supporting sources:

Texas Instruments Incorporated (October 2025, last-updated footer). TIDA-020076 fitted BOM, SLURB87. https://www.ti.com/lit/pdf/SLURB87

Linda Ager‐Wick Ellingsen; Guillaume Majeau‐Bettez; Bhawna Singh; Akhilesh Kumar Srivastava; Lars Ole Valøen; Anders Hammer Strømman (2014; first online 1 November 2013). Life Cycle Assessment of a Lithium‐Ion Battery Vehicle Pack. Journal of Industrial Ecology 18(1), 113–124. https://doi.org/10.1111/jiec.12072

Sanna Wickerts; Rickard Arvidsson; Anders Nordelöf; Magdalena Svanström; Patrik Johansson (2023). Prospective Life Cycle Assessment of Lithium-Sulfur Batteries for Stationary Energy Storage. https://doi.org/10.1021/acssuschemeng.3c00141

Sanna Wickerts; Rickard Arvidsson; Anders Nordelöf; Magdalena Svanström; Patrik Johansson (2024). Correction to “Prospective Life Cycle Assessment of Lithium–Sulfur Batteries for Stationary Energy Storage”. https://doi.org/10.1021/acssuschemeng.4c01782

Inventory changes relative to source: Not assessed

Equivalence to the original source inventory has not been established.

Background database
ecoinvent / 3.12
Background system model
cut-off
Biosphere database
ecoinvent / 3.12

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Not provided
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level Not assessed
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 5 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change 150.758 kg CO2-Eq / unit
Screening result

This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.

Show all 16 indicator totals
Acidification 3.25349 mol H+-Eq / unit
Climate change 150.758 kg CO2-Eq / unit
Freshwater ecotoxicity 937.61 CTUe / unit
Freshwater eutrophication 0.411195 kg P-Eq / unit
Marine eutrophication 0.179809 kg N-Eq / unit
Terrestrial eutrophication 1.85594 mol N-Eq / unit
Human toxicity, cancer -2.9585e-07 CTUh / unit
Human toxicity, non-cancer 1.2160e-05 CTUh / unit
Ionising radiation 54.7245 kBq U235-Eq / unit
Land use 1054.84 dimensionless / unit
Ozone depletion 4.5802e-06 kg CFC-11-Eq / unit
Particulate matter 9.7156e-06 disease incidence / unit
Photochemical ozone formation 0.587866 kg NMVOC-Eq / unit
Resource use, fossils 1615.96 MJ, net calorific value / unit
Resource use, minerals and metals 0.0615727 kg Sb-Eq / unit
Water use 1549.17 m3 world Eq deprived / unit
Calculation details

Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact 4e70d56a85b1 · calculated 2026-11-03 09:08 UTC. These screening results do not replace a reviewed comparative LCA.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
battery control and cooling system production, 16 modules
GLO
battery control and cooling system, 16 modules
1
unit - Reference flow

Inputs

Technosphere inputs 4 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
battery central control and protection unit
1
unit -
101.755 kg CO2-Eq / unit 67.5% of total
printed circuit board, battery module control, mounted
1.12
kilogram -
36.3701 kg CO2-Eq / unit 24.1% of total
cooling system
10
kilogram -
58.321 kg CO2-Eq / unit 38.7% of total
market for used Li-ion battery
GLO
used Li-ion battery
-15.61
kilogram -
-45.6878 kg CO2-Eq / unit -30.3% of total
BAFU:2025
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 1 version · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  1. Version 1.0.0
    Published

    This battery control and cooling system production, 16 modules reference makes its product and manufacturing boundary explicit. Its supplied inputs include battery central control…

    Published · Viewing · Latest
Show full version history table (1 version)
Version Published Reason for this version Link
Version 1.0.0 2026-11-03 This battery control and cooling system production, 16 modules reference makes its product and manufacturing boundary explicit. Its supplied inputs include battery central control and protection unit, printed circuit board, battery module control, mounted, cooling system. Current view
About this version

About this version

This battery control and cooling system production, 16 modules reference makes its product and manufacturing boundary explicit. Its supplied inputs include battery central control and protection unit, printed circuit board, battery module control, mounted, cooling system.

Release notes

The reference retains the documented engineering proxies and allowances; it does not establish a manufacturer-specific grade or measured production line.

Source: https://doi.org/10.1021/acssuschemeng.4c01782.s001, https://doi.org/10.1111/jiec.12072.

Declared foreground licence: CC-BY-NC-4.0. Source publications and external supplier inventories retain their own terms.

Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content