Description
Deep-borehole drilling service providing 1 m of drilled length. It represents the recorded drilling energy, materials, emissions, water and treatment inputs used by the geological-storage model.
Carbon capture and storage
Reference product drilling, deep borehole RER
Stable dataset identity
drilling-deep-borehole
1.0.1Published inventory
Process description and catalog context. View scientific metadata
Deep-borehole drilling service providing 1 m of drilled length. It represents the recorded drilling energy, materials, emissions, water and treatment inputs used by the geological-storage model.
Classification, keywords, bookmarks and download counts.
Classification path: Carbon capture > Carbon capture and storage
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
Volkart, K., Bauer, C., Boulet, C. (2013). Life cycle assessment of carbon capture and storage in power generation and industry in Europe. International Journal of Greenhouse Gas Control 16, 91–106. https://doi.org/10.1016/j.ijggc.2013.03.003
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per meter, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-23 19:36 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
drilling, deep borehole
RER
|
drilling, deep borehole
NEEDS_2000 / CCS
|
1
|
meter | Reference flow |
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
AOX, Adsorbable Organic Halogen as Cl
|
water / surface water
|
4.78e-07
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.00176344
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
2.1261e-13
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Aluminium
|
water / surface water
|
0.06
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
261.116
CTUe / meter
1.1% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
9.2760e-11
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Arsenic, ion
|
water / surface water
|
4.20e-04
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
1.3706
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
1.4322e-08
CTUh / meter
0.6% of total
1.0609e-06
CTUh / meter
3.7% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
BOD5, Biological Oxygen Demand
|
water / surface water
|
0.3
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Barium
|
water / surface water
|
6.00e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
22.1854
CTUe / meter
0.1% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
8.5104e-08
CTUh / meter
0.3% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Boron
|
water / surface water
|
9.00e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.212265
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
COD, Chemical Oxygen Demand
|
water / surface water
|
3
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Calcium, ion
|
water / surface water
|
0.6
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Chloride
|
water / surface water
|
6
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
1808.64
CTUe / meter
7.3% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Chromium, ion
|
water / surface water
|
6.00e-04
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.571378
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
1.2414e-15
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
DOC, Dissolved Organic Carbon
|
water / surface water
|
0.3
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Fluoride
|
water / surface water
|
3.00e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.061083
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
1.9903e-09
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Hydrocarbons, aromatic
|
water / surface water
|
3.00e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
66.582
CTUe / meter
0.3% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
8.9487e-10
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Iron, ion
|
water / surface water
|
0.18
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
379.53
CTUe / meter
1.5% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Magnesium
|
water / surface water
|
0.12
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.141504
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
3.9457e-11
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Manganese
|
water / surface water
|
3.00e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.155026
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Methane, dichloro-, HCC-30
|
water / surface water
|
0.06
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
8.496
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
2.6786e-09
CTUh / meter
0.1% of total
2.6945e-08
CTUh / meter
0.1% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Particulates, > 10 um
|
air / non-urban air or from high stacks
|
0.01
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Phosphorus
|
water / surface water
|
1.20e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.00243768
CTUe / meter
0.0% of total
0.0012
kg P-Eq / meter
0.4% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
2.3797e-12
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Potassium, ion
|
water / surface water
|
0.9
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Silicon
|
water / surface water
|
0.03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0.140781
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
5.9946e-12
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Sodium, ion
|
water / surface water
|
6
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Strontium
|
water / surface water
|
0.02
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
325.321
CTUe / meter
1.3% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Sulfur
|
water / surface water
|
0.12
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
TOC, Total Organic Carbon
|
water / surface water
|
0.3
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
|
|
Zinc, ion
|
water / surface water
|
1.20e-03
|
kilogram |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
1.99141
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
3.1669e-09
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
activated bentonite production
DE
|
activated bentonite
Materials/fuels
|
20
|
kilogram |
0.0569984
mol H+-Eq / meter
0.2% of total
8.67974
kg CO2-Eq / meter
0.4% of total
72.5923
CTUe / meter
0.3% of total
0.00568122
kg P-Eq / meter
1.9% of total
0.00715841
kg N-Eq / meter
0.1% of total
0.0772575
mol N-Eq / meter
0.1% of total
7.0909e-09
CTUh / meter
0.3% of total
2.0319e-07
CTUh / meter
0.7% of total
2.33485
kBq U235-Eq / meter
1.1% of total
274.942
dimensionless / meter
3.2% of total
3.0029e-06
kg CFC-11-Eq / meter
4.9% of total
6.6809e-07
disease incidence / meter
1.1% of total
0.0296408
kg NMVOC-Eq / meter
0.1% of total
208.179
MJ, net calorific value / meter
0.7% of total
0.000106137
kg Sb-Eq / meter
1.5% of total
3.08657
m3 world Eq deprived / meter
0.5% of total
BAFU:2025
|
|
|
barite production
RER
|
barite
Materials/fuels
|
270
|
kilogram |
0.100159
mol H+-Eq / meter
0.4% of total
27.601
kg CO2-Eq / meter
1.1% of total
80.8843
CTUe / meter
0.3% of total
0.0243686
kg P-Eq / meter
8.0% of total
0.0202135
kg N-Eq / meter
0.2% of total
0.17547
mol N-Eq / meter
0.2% of total
2.6711e-08
CTUh / meter
1.1% of total
2.8838e-07
CTUh / meter
1.0% of total
32.9879
kBq U235-Eq / meter
15.3% of total
220.511
dimensionless / meter
2.6% of total
6.8406e-07
kg CFC-11-Eq / meter
1.1% of total
6.0433e-07
disease incidence / meter
1.0% of total
0.0607634
kg NMVOC-Eq / meter
0.2% of total
602.732
MJ, net calorific value / meter
1.9% of total
0.00228581
kg Sb-Eq / meter
31.7% of total
15.9238
m3 world Eq deprived / meter
2.7% of total
BAFU:2025
|
|
|
cement production, Portland
CH
|
cement, Portland
Materials/fuels
|
200
|
kilogram |
0.274761
mol H+-Eq / meter
1.1% of total
148.835
kg CO2-Eq / meter
6.1% of total
76.3637
CTUe / meter
0.3% of total
0.0221551
kg P-Eq / meter
7.3% of total
0.0791151
kg N-Eq / meter
0.7% of total
0.888662
mol N-Eq / meter
0.8% of total
8.7123e-09
CTUh / meter
0.4% of total
4.0006e-07
CTUh / meter
1.4% of total
19.9648
kBq U235-Eq / meter
9.3% of total
89.7165
dimensionless / meter
1.0% of total
5.0529e-07
kg CFC-11-Eq / meter
0.8% of total
1.5360e-06
disease incidence / meter
2.6% of total
0.2396
kg NMVOC-Eq / meter
0.7% of total
507.606
MJ, net calorific value / meter
1.6% of total
2.9048e-05
kg Sb-Eq / meter
0.4% of total
20.2287
m3 world Eq deprived / meter
3.5% of total
BAFU:2025
|
|
|
diesel, burned in diesel-electric generating set, 18.5kW
GLO
|
diesel, burned in diesel-electric generating set, 18.5kW
Materials/fuels
|
6300
|
megajoule |
21.4395
mol H+-Eq / meter
89.3% of total
1689.93
kg CO2-Eq / meter
69.5% of total
3854.93
CTUe / meter
15.6% of total
0.0382174
kg P-Eq / meter
12.6% of total
10.2323
kg N-Eq / meter
94.5% of total
110.215
mol N-Eq / meter
94.6% of total
1.3569e-07
CTUh / meter
5.8% of total
4.4003e-06
CTUh / meter
15.4% of total
37.6374
kBq U235-Eq / meter
17.5% of total
5342.59
dimensionless / meter
62.2% of total
3.6381e-05
kg CFC-11-Eq / meter
58.9% of total
2.4824e-05
disease incidence / meter
41.5% of total
30.9049
kg NMVOC-Eq / meter
90.6% of total
21309.2
MJ, net calorific value / meter
66.5% of total
0.000352664
kg Sb-Eq / meter
4.9% of total
335.607
m3 world Eq deprived / meter
57.4% of total
BAFU:2025
|
|
|
market for lignite
RER
|
lignite
Materials/fuels
|
0.2
|
kilogram |
5.2503e-06
mol H+-Eq / meter
0.0% of total
0.00629273
kg CO2-Eq / meter
0.0% of total
0.712799
CTUe / meter
0.0% of total
0.000463911
kg P-Eq / meter
0.2% of total
9.6246e-05
kg N-Eq / meter
0.0% of total
1.1649e-05
mol N-Eq / meter
0.0% of total
2.7777e-12
CTUh / meter
0.0% of total
2.7827e-11
CTUh / meter
0.0% of total
0.00146976
kBq U235-Eq / meter
0.0% of total
0.0166499
dimensionless / meter
0.0% of total
3.5004e-11
kg CFC-11-Eq / meter
0.0% of total
3.5338e-11
disease incidence / meter
0.0% of total
5.8451e-06
kg NMVOC-Eq / meter
0.0% of total
1.9122
MJ, net calorific value / meter
0.0% of total
3.3403e-09
kg Sb-Eq / meter
0.0% of total
0.000535108
m3 world Eq deprived / meter
0.0% of total
BAFU:2025
|
|
|
market for chemical, organic
GLO
|
chemical, organic
Materials/fuels
|
9.05
|
kilogram |
0.0555987
mol H+-Eq / meter
0.2% of total
17.8533
kg CO2-Eq / meter
0.7% of total
79.9604
CTUe / meter
0.3% of total
0.00198137
kg P-Eq / meter
0.7% of total
0.010049
kg N-Eq / meter
0.1% of total
0.124339
mol N-Eq / meter
0.1% of total
6.6694e-09
CTUh / meter
0.3% of total
1.1387e-07
CTUh / meter
0.4% of total
1.63866
kBq U235-Eq / meter
0.8% of total
17.9964
dimensionless / meter
0.2% of total
1.1651e-06
kg CFC-11-Eq / meter
1.9% of total
6.6747e-07
disease incidence / meter
1.1% of total
0.0539987
kg NMVOC-Eq / meter
0.2% of total
526.703
MJ, net calorific value / meter
1.6% of total
4.8252e-05
kg Sb-Eq / meter
0.7% of total
2.21559
m3 world Eq deprived / meter
0.4% of total
BAFU:2025
|
|
|
market for chemicals, inorganic
GLO
|
chemical, inorganic
Materials/fuels
|
42.2
|
kilogram |
0.4798
mol H+-Eq / meter
2.0% of total
69.653
kg CO2-Eq / meter
2.9% of total
345.57
CTUe / meter
1.4% of total
0.0230152
kg P-Eq / meter
7.6% of total
0.0576061
kg N-Eq / meter
0.5% of total
0.847349
mol N-Eq / meter
0.7% of total
5.0223e-08
CTUh / meter
2.2% of total
1.0992e-06
CTUh / meter
3.8% of total
19.1775
kBq U235-Eq / meter
8.9% of total
266.744
dimensionless / meter
3.1% of total
8.2647e-06
kg CFC-11-Eq / meter
13.4% of total
4.1386e-06
disease incidence / meter
6.9% of total
0.204098
kg NMVOC-Eq / meter
0.6% of total
966.468
MJ, net calorific value / meter
3.0% of total
0.000495235
kg Sb-Eq / meter
6.9% of total
18.4782
m3 world Eq deprived / meter
3.2% of total
BAFU:2025
|
|
|
market for lubricating oil
RER
|
lubricating oil
Materials/fuels
|
60
|
kilogram |
0.352375
mol H+-Eq / meter
1.5% of total
82.2677
kg CO2-Eq / meter
3.4% of total
788.225
CTUe / meter
3.2% of total
0.0157107
kg P-Eq / meter
5.2% of total
0.117687
kg N-Eq / meter
1.1% of total
0.927595
mol N-Eq / meter
0.8% of total
3.5889e-08
CTUh / meter
1.5% of total
8.5215e-07
CTUh / meter
3.0% of total
15.6406
kBq U235-Eq / meter
7.3% of total
1082.61
dimensionless / meter
12.6% of total
7.3688e-06
kg CFC-11-Eq / meter
11.9% of total
2.0064e-06
disease incidence / meter
3.4% of total
1.34437
kg NMVOC-Eq / meter
3.9% of total
4342.14
MJ, net calorific value / meter
13.6% of total
0.000263752
kg Sb-Eq / meter
3.7% of total
72.4584
m3 world Eq deprived / meter
12.4% of total
BAFU:2025
|
|
|
market for steel, low-alloyed
GLO
|
steel, low-alloyed
Materials/fuels
|
210
|
kilogram |
1.12519
mol H+-Eq / meter
4.7% of total
351.124
kg CO2-Eq / meter
14.4% of total
798.654
CTUe / meter
3.2% of total
0.137554
kg P-Eq / meter
45.2% of total
0.264603
kg N-Eq / meter
2.4% of total
2.8501
mol N-Eq / meter
2.4% of total
1.3416e-06
CTUh / meter
57.6% of total
8.3032e-06
CTUh / meter
29.0% of total
75.0921
kBq U235-Eq / meter
34.9% of total
895.789
dimensionless / meter
10.4% of total
3.4592e-06
kg CFC-11-Eq / meter
5.6% of total
2.4399e-05
disease incidence / meter
40.8% of total
1.12228
kg NMVOC-Eq / meter
3.3% of total
3070.87
MJ, net calorific value / meter
9.6% of total
0.00355996
kg Sb-Eq / meter
49.3% of total
91.8226
m3 world Eq deprived / meter
15.7% of total
Mapped treatment or supply model
|
|
|
market for transport, freight train
Europe without Switzerland
|
transport, freight train
Materials/fuels
|
487
|
ton kilometer |
0.0356701
mol H+-Eq / meter
0.1% of total
8.14755
kg CO2-Eq / meter
0.3% of total
21.4583
CTUe / meter
0.1% of total
0.00491949
kg P-Eq / meter
1.6% of total
0.0118592
kg N-Eq / meter
0.1% of total
0.118833
mol N-Eq / meter
0.1% of total
9.8104e-09
CTUh / meter
0.4% of total
1.0364e-07
CTUh / meter
0.4% of total
7.98661
kBq U235-Eq / meter
3.7% of total
150.635
dimensionless / meter
1.8% of total
1.9809e-07
kg CFC-11-Eq / meter
0.3% of total
3.6709e-07
disease incidence / meter
0.6% of total
0.0378979
kg NMVOC-Eq / meter
0.1% of total
157.496
MJ, net calorific value / meter
0.5% of total
1.8258e-05
kg Sb-Eq / meter
0.3% of total
4.61586
m3 world Eq deprived / meter
0.8% of total
BAFU:2025
|
|
|
market for transport, freight, lorry, unspecified
RER
|
transport, freight, lorry, unspecified
Materials/fuels
|
81.1
|
ton kilometer |
0.0641559
mol H+-Eq / meter
0.3% of total
15.3226
kg CO2-Eq / meter
0.6% of total
43.5955
CTUe / meter
0.2% of total
0.00145843
kg P-Eq / meter
0.5% of total
0.0263848
kg N-Eq / meter
0.2% of total
0.274181
mol N-Eq / meter
0.2% of total
5.3816e-09
CTUh / meter
0.2% of total
1.1897e-07
CTUh / meter
0.4% of total
1.76981
kBq U235-Eq / meter
0.8% of total
90.5524
dimensionless / meter
1.1% of total
5.7037e-07
kg CFC-11-Eq / meter
0.9% of total
4.7350e-07
disease incidence / meter
0.8% of total
0.097873
kg NMVOC-Eq / meter
0.3% of total
222.108
MJ, net calorific value / meter
0.7% of total
3.5908e-05
kg Sb-Eq / meter
0.5% of total
17.7676
m3 world Eq deprived / meter
3.0% of total
BAFU:2025
|
|
|
treatment of drilling waste, landfarming
CH
|
drilling waste
Waste to treatment
|
-237
|
kilogram |
0.00217968
mol H+-Eq / meter
0.0% of total
0.310896
kg CO2-Eq / meter
0.0% of total
14968.6
CTUe / meter
60.7% of total
0.00596419
kg P-Eq / meter
2.0% of total
0.000967871
kg N-Eq / meter
0.0% of total
0.0105395
mol N-Eq / meter
0.0% of total
6.0665e-07
CTUh / meter
26.1% of total
9.7976e-06
CTUh / meter
34.3% of total
0.0438574
kBq U235-Eq / meter
0.0% of total
1.64402
dimensionless / meter
0.0% of total
6.1786e-09
kg CFC-11-Eq / meter
0.0% of total
7.3472e-09
disease incidence / meter
0.0% of total
0.0033631
kg NMVOC-Eq / meter
0.0% of total
4.03185
MJ, net calorific value / meter
0.0% of total
1.2793e-06
kg Sb-Eq / meter
0.0% of total
0.100326
m3 world Eq deprived / meter
0.0% of total
BAFU:2025
|
|
|
treatment of drilling waste, residual material landfill
CH
|
drilling waste
Waste to treatment
|
-158
|
kilogram |
0.00555059
mol H+-Eq / meter
0.0% of total
1.68028
kg CO2-Eq / meter
0.1% of total
494.739
CTUe / meter
2.0% of total
0.0179872
kg P-Eq / meter
5.9% of total
0.00206118
kg N-Eq / meter
0.0% of total
0.0220301
mol N-Eq / meter
0.0% of total
6.9149e-08
CTUh / meter
3.0% of total
1.6097e-06
CTUh / meter
5.6% of total
0.17549
kBq U235-Eq / meter
0.1% of total
150.043
dimensionless / meter
1.7% of total
8.6775e-08
kg CFC-11-Eq / meter
0.1% of total
4.3206e-08
disease incidence / meter
0.1% of total
0.0120527
kg NMVOC-Eq / meter
0.0% of total
45.5743
MJ, net calorific value / meter
0.1% of total
1.7759e-06
kg Sb-Eq / meter
0.0% of total
1.61105
m3 world Eq deprived / meter
0.3% of total
BAFU:2025
|
|
|
treatment of hazardous waste, hazardous waste incineration
CH
|
hazardous waste, for incineration
Waste to treatment
|
-5
|
kilogram |
0.0104019
mol H+-Eq / meter
0.0% of total
11.7906
kg CO2-Eq / meter
0.5% of total
176.631
CTUe / meter
0.7% of total
0.00338545
kg P-Eq / meter
1.1% of total
0.00293483
kg N-Eq / meter
0.0% of total
0.0270419
mol N-Eq / meter
0.0% of total
7.9819e-09
CTUh / meter
0.3% of total
1.1909e-07
CTUh / meter
0.4% of total
0.915198
kBq U235-Eq / meter
0.4% of total
10.4718
dimensionless / meter
0.1% of total
1.0747e-07
kg CFC-11-Eq / meter
0.2% of total
1.0785e-07
disease incidence / meter
0.2% of total
0.0121409
kg NMVOC-Eq / meter
0.0% of total
56.4559
MJ, net calorific value / meter
0.2% of total
2.1557e-05
kg Sb-Eq / meter
0.3% of total
1.10755
m3 world Eq deprived / meter
0.2% of total
BAFU:2025
|
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
Water, well, in ground
|
natural resource / in water
|
3.34
|
cubic meter |
0
mol H+-Eq / meter
0.0% of total
0
kg CO2-Eq / meter
0.0% of total
0
CTUe / meter
0.0% of total
0
kg P-Eq / meter
0.0% of total
0
kg N-Eq / meter
0.0% of total
0
mol N-Eq / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
CTUh / meter
0.0% of total
0
kBq U235-Eq / meter
0.0% of total
0
dimensionless / meter
0.0% of total
0
kg CFC-11-Eq / meter
0.0% of total
0
disease incidence / meter
0.0% of total
0
kg NMVOC-Eq / meter
0.0% of total
0
MJ, net calorific value / meter
0.0% of total
0
kg Sb-Eq / meter
0.0% of total
0
m3 world Eq deprived / meter
0.0% of total
EF biosphere factor
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
First published inventory; no earlier version is available for comparison.
PublishedNo overall rationale was recorded for this version.
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-07-21 | No overall rationale was recorded for this version. | Current view |
| Version 1.0.0 | 2026-07-15 | First published inventory; no earlier version is available for comparison. | Open version |
No overall rationale was recorded for this version.
No overall rationale was recorded for this version.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Version metadata | Commercial maturity stage | first_commercial | mature_commercial | No explanation was recorded for this change. |
| Version metadata | Inventory evidence types | Literature | Literature; Engineering estimate | |
| Version metadata | Description | This dataset is part of the CCS pathway assessment of Volkart et al. (2013), which compares carbon capture and storage configurations across power-generation and industrial systems in Europe. It represents drilling activity for the subsurface infrastructure required to inject and store captured carbon dioxide in deep geological formations. | Deep-borehole drilling service providing 1 m of drilled length. It represents the recorded drilling energy, materials, emissions, water and treatment inputs used by the geological-storage model. | |
| Version metadata | Geographical representativeness | 2 | 3 | |
| Version metadata | Methodology and allocation explanation | Volkart et al. (2013) compare prospective 2025/2050 power and cement systems. The paper's base CCS case uses 200 km pipeline transport and a 1000 m saline-aquifer depth, with 110 bar CO2 transport pressure. Individual CLIC capture, storage, infrastructure and conversion nodes have distinct reference units and adaptations; the publication year is not a common inventory measurement year. The retrieved supplementary XLS contains five cement GHG result decompositions, not a native process inventory; these LCIA results must not be compared as exchange amounts. Source-study CARMA funding roles are preserved without extending them to later CLIC adaptations. | Volkart et al. (2013) model prospective European power and cement systems for 2025 and 2050. The reference CCS chain assumes a 200 km pipeline, storage in a saline aquifer at 1000 m depth and CO2 compression to 110 bar. The pipeline and wells have assumed 30-year lives, with 20 bar injection overpressure. These are source scenario assumptions; the route, depth, reference unit and supplier adaptations of this individual record govern its use. Publication in 2013 does not establish a common inventory measurement year. | |
| Version metadata | Source | Life cycle assessment of carbon capture and storage in power generation and industry in Europe, Volkart et al., 2013, International Journal of Greenhouse Gas Control | Volkart, K., Bauer, C., Boulet, C. (2013). Life cycle assessment of carbon capture and storage in power generation and industry in Europe. International Journal of Greenhouse Gas Control 16, 91–106. https://doi.org/10.1016/j.ijggc.2013.03.003 | |
| Version metadata | Contributors, publications, projects and supporting evidence | Funding: 1. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 1. Project: Name: CARbon dioxide MAnagement in power generation Funding: 1. Project: Acronym: CARMA Funding: 1. Project: Relation: source_study Funding: 1. Project: Grant identifier: Not set Funding: 1. Organization: Ror: Not set Funding: 1. Organization: Url: Not set Funding: 1. Organization: Name: Swisselectric Research Funding: 1. Award identifier: Not set Funding: 2. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 2. Project: Name: CARbon dioxide MAnagement in power generation Funding: 2. Project: Acronym: CARMA Funding: 2. Project: Relation: source_study Funding: 2. Project: Grant identifier: Not set Funding: 2. Organization: Ror: https://ror.org/005616b46 Funding: 2. Organization: Url: Not set Funding: 2. Organization: Name: Competence Center for Energy and Mobility (CCEM) Funding: 2. Award identifier: Not set Funding: 3. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 3. Project: Name: CARbon dioxide MAnagement in power generation Funding: 3. Project: Acronym: CARMA Funding: 3. Project: Relation: source_study Funding: 3. Project: Grant identifier: Not set Funding: 3. Organization: Ror: Not set Funding: 3. Organization: Url: Not set Funding: 3. Organization: Name: Competence Center for Environment and Sustainability (CCES) Funding: 3. Award identifier: Not set Funding: 4. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 4. Project: Name: CARbon dioxide MAnagement in power generation Funding: 4. Project: Acronym: CARMA Funding: 4. Project: Relation: source_study Funding: 4. Project: Grant identifier: Not set Funding: 4. Organization: Ror: Not set Funding: 4. Organization: Url: Not set Funding: 4. Organization: Name: Alstom Funding: 4. Award identifier: Not set Funding: 5. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 5. Project: Name: CARbon dioxide MAnagement in power generation Funding: 5. Project: Acronym: CARMA Funding: 5. Project: Relation: source_study Funding: 5. Project: Grant identifier: Not set Funding: 5. Organization: Ror: https://ror.org/020ddnn22 Funding: 5. Organization: Url: Not set Funding: 5. Organization: Name: Swiss Federal Office of Energy Funding: 5. Award identifier: Not set Evidence: 1. Origin: source_import Evidence: 1. Target field: publications Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: editor_verification Evidence: 2. Target field: publications Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 2. Source reference: https://api.crossref.org/works/10.1016%2Fj.ijggc.2013.03.003 Evidence: 3. Origin: source_import Evidence: 3. Target field: data_origins Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: source_import Evidence: 4. Target field: projects Evidence: 4. Qualification: Verified CARMA source study; duration 2009–2013 is not inventory time coverage. Evidence: 4. Source location: inventory_snapshot/worksheet name Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: editor_verification Evidence: 5. Target field: projects Evidence: 5. Qualification: Verified CARMA source study; duration 2009–2013 is not inventory time coverage. Evidence: 5. Source location: Project heading and details Evidence: 5. Source reference: https://www.psi.ch/fr/eem/projects/carma Evidence: 6. Origin: source_import Evidence: 6. Target field: projects Evidence: 6. Qualification: Verified CARMA source study; duration 2009–2013 is not inventory time coverage. Evidence: 6. Source location: source Evidence: 6. Source reference: Existing published CLIC inventory documentation Evidence: 7. Origin: source_import Evidence: 7. Target field: funding Evidence: 7. Qualification: Original-project financing only; not later adaptation or CLIC funding. Evidence: 7. Source location: inventory_snapshot/worksheet name Evidence: 7. Source reference: Existing published CLIC inventory documentation Evidence: 8. Origin: editor_verification Evidence: 8. Target field: funding Evidence: 8. Qualification: Original-project financing only; not later adaptation or CLIC funding. Evidence: 8. Source location: Project details / Financing Evidence: 8. Source reference: https://www.psi.ch/fr/eem/projects/carma Evidence: 9. Origin: editor_verification Evidence: 9. Target field: funding Evidence: 9. Qualification: Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope. Evidence: 9. Source location: Organization identity and registered names Evidence: 9. Source reference: https://api.ror.org/v2/organizations/020ddnn22 Evidence: 10. Origin: editor_verification Evidence: 10. Target field: publications Evidence: 10. Qualification: Canonical primary and legacy citations are aligned without changing freeform source, inventory source text or inventory contributors. Publication year is not a measurement/reference year. EPR underlying inventories are acknowledged to Roberto Dones and Roth et al. (2009); component quantities are not all printed in the 2012 article. Preserve each declared source role and historical affiliation. Evidence: 10. Source location: Original paper/SI byline; pinned DOI registration and institutional identity evidence Evidence: 10. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: methodology_notes Evidence: 11. Qualification: Volkart et al. (2013) compare prospective 2025/2050 power and cement systems. The paper's base CCS case uses 200 km pipeline transport and a 1000 m saline-aquifer depth, with 110 bar CO2 transport pressure. Individual CLIC capture, storage, infrastructure and conversion nodes have distinct reference units and adaptations; the publication year is not a common inventory measurement year. The retrieved supplementary XLS contains five cement GHG result decompositions, not a native process inventory; these LCIA results must not be compared as exchange amounts. Source-study CARMA funding roles are preserved without extending them to later CLIC adaptations. Evidence: 11. Source location: Sections 2.1–2.2, source Tables 1–3 and original supplementary XLS Evidence: 11. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Projects: 1. Url: https://www.psi.ch/fr/eem/projects/carma Projects: 1. Name: CARbon dioxide MAnagement in power generation Projects: 1. Acronym: CARMA Projects: 1. Relation: source_study Projects: 1. Grant identifier: Not set Publications: 1. Doi: 10.1016/j.ijggc.2013.03.003 Publications: 1. Url: https://doi.org/10.1016/j.ijggc.2013.03.003 Publications: 1. Title: Life cycle assessment of carbon capture and storage in power generation and industry in Europe Publications: 1. Scientific authors: 1. Name: Kathrin Volkart Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/03eh3y714 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.psi.ch/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Laboratory for Energy Systems Analysis, Paul Scherrer Institute, Villigen PSI, Switzerland Publications: 1. Scientific authors: 2. Name: Christian Bauer Publications: 1. Scientific authors: 2. Orcid: 0000-0002-1083-9200 Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/03eh3y714 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.psi.ch/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Laboratory for Energy Systems Analysis, Paul Scherrer Institute, Villigen PSI, Switzerland Publications: 1. Scientific authors: 3. Name: Céline Boulet Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/03eh3y714 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.psi.ch/ Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Laboratory for Energy Systems Analysis, Paul Scherrer Institute, Villigen PSI, Switzerland Publications: 1. Citation: Volkart, K., Bauer, C., Boulet, C. (2013). Life cycle assessment of carbon capture and storage in power generation and industry in Europe. International Journal of Greenhouse Gas Control 16, 91–106. https://doi.org/10.1016/j.ijggc.2013.03.003 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2013 |
Funding: 1. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 1. Project: Name: CARbon dioxide MAnagement in power generation Funding: 1. Project: Acronym: CARMA Funding: 1. Project: Relation: source_study Funding: 1. Project: Grant identifier: Not set Funding: 1. Organization: Ror: Not set Funding: 1. Organization: Url: Not set Funding: 1. Organization: Name: Swisselectric Research Funding: 1. Award identifier: Not set Funding: 2. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 2. Project: Name: CARbon dioxide MAnagement in power generation Funding: 2. Project: Acronym: CARMA Funding: 2. Project: Relation: source_study Funding: 2. Project: Grant identifier: Not set Funding: 2. Organization: Ror: https://ror.org/005616b46 Funding: 2. Organization: Url: Not set Funding: 2. Organization: Name: Competence Center for Energy and Mobility (CCEM) Funding: 2. Award identifier: Not set Funding: 3. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 3. Project: Name: CARbon dioxide MAnagement in power generation Funding: 3. Project: Acronym: CARMA Funding: 3. Project: Relation: source_study Funding: 3. Project: Grant identifier: Not set Funding: 3. Organization: Ror: Not set Funding: 3. Organization: Url: Not set Funding: 3. Organization: Name: Competence Center for Environment and Sustainability (CCES) Funding: 3. Award identifier: Not set Funding: 4. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 4. Project: Name: CARbon dioxide MAnagement in power generation Funding: 4. Project: Acronym: CARMA Funding: 4. Project: Relation: source_study Funding: 4. Project: Grant identifier: Not set Funding: 4. Organization: Ror: Not set Funding: 4. Organization: Url: Not set Funding: 4. Organization: Name: Alstom Funding: 4. Award identifier: Not set Funding: 5. Project: Url: https://www.psi.ch/fr/eem/projects/carma Funding: 5. Project: Name: CARbon dioxide MAnagement in power generation Funding: 5. Project: Acronym: CARMA Funding: 5. Project: Relation: source_study Funding: 5. Project: Grant identifier: Not set Funding: 5. Organization: Ror: https://ror.org/020ddnn22 Funding: 5. Organization: Url: Not set Funding: 5. Organization: Name: Swiss Federal Office of Energy Funding: 5. Award identifier: Not set Evidence: 1. Origin: source_import Evidence: 1. Target field: publications Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: editor_verification Evidence: 2. Target field: publications Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 2. Source reference: https://api.crossref.org/works/10.1016%2Fj.ijggc.2013.03.003 Evidence: 3. Origin: source_import Evidence: 3. Target field: data_origins Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: source_import Evidence: 4. Target field: data_origins Evidence: 4. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 4. Source location: description Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: source_import Evidence: 5. Target field: projects Evidence: 5. Qualification: Verified CARMA source study; duration 2009–2013 is not inventory time coverage. Evidence: 5. Source location: inventory_snapshot/worksheet name Evidence: 5. Source reference: Existing published CLIC inventory documentation Evidence: 6. Origin: editor_verification Evidence: 6. Target field: projects Evidence: 6. Qualification: Verified CARMA source study; duration 2009–2013 is not inventory time coverage. Evidence: 6. Source location: Project heading and details Evidence: 6. Source reference: https://www.psi.ch/fr/eem/projects/carma Evidence: 7. Origin: source_import Evidence: 7. Target field: projects Evidence: 7. Qualification: Verified CARMA source study; duration 2009–2013 is not inventory time coverage. Evidence: 7. Source location: source Evidence: 7. Source reference: Existing published CLIC inventory documentation Evidence: 8. Origin: source_import Evidence: 8. Target field: funding Evidence: 8. Qualification: Original-project financing only; not later adaptation or CLIC funding. Evidence: 8. Source location: inventory_snapshot/worksheet name Evidence: 8. Source reference: Existing published CLIC inventory documentation Evidence: 9. Origin: editor_verification Evidence: 9. Target field: funding Evidence: 9. Qualification: Original-project financing only; not later adaptation or CLIC funding. Evidence: 9. Source location: Project details / Financing Evidence: 9. Source reference: https://www.psi.ch/fr/eem/projects/carma Evidence: 10. Origin: editor_verification Evidence: 10. Target field: funding Evidence: 10. Qualification: Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope. Evidence: 10. Source location: Organization identity and registered names Evidence: 10. Source reference: https://api.ror.org/v2/organizations/020ddnn22 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: publications Evidence: 11. Qualification: Canonical primary and legacy citations are aligned without changing freeform source, inventory source text or inventory contributors. Publication year is not a measurement/reference year. EPR underlying inventories are acknowledged to Roberto Dones and Roth et al. (2009); component quantities are not all printed in the 2012 article. Preserve each declared source role and historical affiliation. Evidence: 11. Source location: Original paper/SI byline; pinned DOI registration and institutional identity evidence Evidence: 11. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 12. Origin: editor_verification Evidence: 12. Target field: methodology_notes Evidence: 12. Qualification: Volkart et al. (2013) compare prospective 2025/2050 power and cement systems. The paper's base CCS case uses 200 km pipeline transport and a 1000 m saline-aquifer depth, with 110 bar CO2 transport pressure. Individual CLIC capture, storage, infrastructure and conversion nodes have distinct reference units and adaptations; the publication year is not a common inventory measurement year. The retrieved supplementary XLS contains five cement GHG result decompositions, not a native process inventory; these LCIA results must not be compared as exchange amounts. Source-study CARMA funding roles are preserved without extending them to later CLIC adaptations. Evidence: 12. Source location: Sections 2.1–2.2, source Tables 1–3 and original supplementary XLS Evidence: 12. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: technology_description Evidence: 13. Qualification: Technical-characterisation review TC-84. Design capacity: Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 13. Source location: fields/design_capacity; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 13. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-84. Design capacity unit: Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: fields/design_capacity_unit; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 14. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-84. Capacity factor (%): Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: fields/capacity_factor_percent; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 15. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-84. Annual production volume: Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: fields/annual_production_volume; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 16. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-84. Annual production volume unit: Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: fields/annual_production_volume_unit; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 17. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-84. Annual production volume year: Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: fields/annual_production_volume_year; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 18. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 19. Origin: editor_verification Evidence: 19. Target field: technology_description Evidence: 19. Qualification: Technical-characterisation review TC-84. Plant or represented-asset lifetime (years): Unspecified. Basis: Retain only the current stated object scope; host power, upstream supplier ratings, per-reference intensities and project allocation do not assign every helper its own capacity or annual output. Current object category: drilling_service. Source Table1 performance is prospective; generation calendars and source/native capacity conflicts retain their distinct roles. Evidence classification: source scope and model calendar checked. Confidence: high for model definition not operating performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 19. Source location: fields/plant_lifetime_years; source paper section2.2/Table1, transport/storage sections; guarded carma-technical-source-context.json Evidence: 19. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 20. Origin: editor_verification Evidence: 20. Target field: technology_description Evidence: 20. Qualification: Technical-characterisation review TC-84. Commercial maturity stage: mature_commercial. Basis: Curator assessment of the established underlying conventional generation, biodiesel, plant infrastructure, pipeline transport/construction or drilling route, as applicable to this exact object category. The primary paper distinguishes these asset/process references from prospective capture integration; commercial storage/drilling context is also corroborated by operator evidence. This is not a source-assigned numeric TRL or validation of this reconstructed LCI. Evidence classification: primary source boundary review and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 20. Source location: Paper section2.2/Table1 and transport/storage assumptions; volkart-source-reading.json Evidence: 20. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 21. Origin: editor_verification Evidence: 21. Target field: technology_description Evidence: 21. Qualification: Technical-characterisation review TC-84. Technology readiness level: 9. Basis: Curator assessment of the established underlying conventional generation, biodiesel, plant infrastructure, pipeline transport/construction or drilling route, as applicable to this exact object category. The primary paper distinguishes these asset/process references from prospective capture integration; commercial storage/drilling context is also corroborated by operator evidence. This is not a source-assigned numeric TRL or validation of this reconstructed LCI. Evidence classification: primary source boundary review and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 21. Source location: Paper section2.2/Table1 and transport/storage assumptions; volkart-source-reading.json Evidence: 21. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 22. Origin: editor_verification Evidence: 22. Target field: technology_description Evidence: 22. Qualification: Technical-characterisation review TC-84. Technological representativeness: 4. Basis: Curator assessment of the exact historical/prospective inventory, with modelled efficiency penalties, transferred supplier/process data or asset/service proxies. The source does not validate the exact current configuration as representative operating plant data. Preserve any existing more conservative score5. Evidence classification: primary source boundary review and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 22. Source location: Paper section2.2/Table1 and transport/storage assumptions; volkart-source-reading.json Evidence: 22. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 23. Origin: editor_verification Evidence: 23. Target field: technology_description Evidence: 23. Qualification: Technical-characterisation review TC-84. Geographical representativeness: 3. Basis: Curator assessment: generic European process/background modelling and selected technology references do not constitute a production-weighted RER factory sample. Treat as regional proxy score3; a global-labelled asset transfers regional evidence and warrants score4. Keep existing more conservative scores. Evidence classification: primary source boundary review and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 23. Source location: Paper section2.2/Table1 and transport/storage assumptions; volkart-source-reading.json Evidence: 23. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Evidence: 24. Origin: editor_verification Evidence: 24. Target field: technology_description Evidence: 24. Qualification: Technical-characterisation review TC-84. Temporal representativeness: 4. Basis: Retain historical/prospective-model score4: the source uses older underlying data and 2025/2050 performance forecasts. Neither the 2013 publication nor those scenario years establish complete foreground measurement periods or annual observation years. Evidence classification: primary source boundary review and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 24. Source location: Paper section2.2/Table1 and transport/storage assumptions; volkart-source-reading.json Evidence: 24. Source reference: https://doi.org/10.1016/j.ijggc.2013.03.003 Projects: 1. Url: https://www.psi.ch/fr/eem/projects/carma Projects: 1. Name: CARbon dioxide MAnagement in power generation Projects: 1. Acronym: CARMA Projects: 1. Relation: source_study Projects: 1. Grant identifier: Not set Publications: 1. Doi: 10.1016/j.ijggc.2013.03.003 Publications: 1. Url: https://doi.org/10.1016/j.ijggc.2013.03.003 Publications: 1. Title: Life cycle assessment of carbon capture and storage in power generation and industry in Europe Publications: 1. Scientific authors: 1. Name: Kathrin Volkart Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/03eh3y714 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.psi.ch/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Laboratory for Energy Systems Analysis, Paul Scherrer Institute, Villigen PSI, Switzerland Publications: 1. Scientific authors: 2. Name: Christian Bauer Publications: 1. Scientific authors: 2. Orcid: 0000-0002-1083-9200 Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/03eh3y714 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.psi.ch/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Laboratory for Energy Systems Analysis, Paul Scherrer Institute, Villigen PSI, Switzerland Publications: 1. Scientific authors: 3. Name: Céline Boulet Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/03eh3y714 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.psi.ch/ Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Laboratory for Energy Systems Analysis, Paul Scherrer Institute, Villigen PSI, Switzerland Publications: 1. Citation: Volkart, K., Bauer, C., Boulet, C. (2013). Life cycle assessment of carbon capture and storage in power generation and industry in Europe. International Journal of Greenhouse Gas Control 16, 91–106. https://doi.org/10.1016/j.ijggc.2013.03.003 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2013 |
|
| Version metadata | Technological representativeness | 3 | 4 | |
| Version metadata | Technology readiness level | 7 | 9 | |
| Version metadata | Intended application | Not set | Well construction demand on an explicit metre basis, with injection/monitoring wells and throughput allocation kept consistent. | Apply reviewed discovery metadata and change explanations from the curated release. |
| Version metadata | System boundary | Not set | The retained drilling bill per metre; well counts and total well depth are demand factors in the storage caller. Capture, pipeline transport and operating injection are separate. | |
| Version metadata | Technology description | Not set | Drilling-length reference allocated by storage callers across injection and monitoring wells, depth, lifetime and stored CO2 throughput. | |
| Version metadata | Limitations on use | Not set | The retrieved supplementary workbook contains five cement greenhouse-gas result decompositions, not a native process inventory. It cannot establish exchange-level agreement for this record. The source paper and current inventory have different background and adaptation histories; exact impact reproduction and contemporary regional plant representativeness are not established. This is not one complete well or one kg CO2 stored. A depth multiplier must be applied at the appropriate caller boundary, avoiding a second normalization of an already allocated drilling demand. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content