Maritime freight

electric drive and buffer battery assembly, container ship

Reference product electric drive and buffer battery, container ship RER

Published Version 1.0.0 Not assessed Latest published

Stable dataset identity electric-drive-and-buffer-battery-assembly-container-ship

Unit
unit
Reuse license
CC BY 4.0
Published
2026-11-03
Version
1.0.0
Technology maturity
Not assessed

Published inventory

Overview

Process description and catalog context. View scientific metadata

Description

Lifetime electric-drive and buffer-battery equipment for one modeled hydrogen container ship.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Maritime freight (transport/maritime/freight)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0

Classification path: Transport > Maritime transport > Maritime freight

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Other

Supporting sources:

Minnan Ye; Phil Sharp; Nigel Brandon; Anthony Kucernak (2022). System-level comparison of ammonia, compressed and liquid hydrogen as fuels for polymer electrolyte fuel cell powered shipping. https://doi.org/10.1016/j.ijhydene.2021.12.164

Shijie Wei; Fayas Malik Kanchiralla; Henk Polinder; Frederik Schulte; Arnold Tukker; Bernhard Steubing (2026). Environmental impacts of fuel cell use in deep-sea shipping towards 2050. https://doi.org/10.1016/j.apenergy.2026.127666

premise ship inventory workbook, pinned source commit 85028621 (2026). https://github.com/polca/premise/blob/850286212ca71e44ebbc0c90909640a5c5db62ae/premise/data/additional_inventories/lci-ships.xlsx

Inventory changes relative to source: Not assessed

Equivalence to the original source inventory has not been established.

Background database
ecoinvent / 3.12
Background system model
cut-off
Biosphere database
ecoinvent / 3.12

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Not provided
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
25 years
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level Not assessed
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 8 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change -1.2207e+07 kg CO2-Eq / unit
Screening result

This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.

Show all 16 indicator totals
Acidification -103488 mol H+-Eq / unit
Climate change -1.2207e+07 kg CO2-Eq / unit
Freshwater ecotoxicity -1.1406e+08 CTUe / unit
Freshwater eutrophication -94534.3 kg P-Eq / unit
Marine eutrophication -21725.3 kg N-Eq / unit
Terrestrial eutrophication -204465 mol N-Eq / unit
Human toxicity, cancer -0.0230204 CTUh / unit
Human toxicity, non-cancer -1.16465 CTUh / unit
Ionising radiation -2.2381e+06 kBq U235-Eq / unit
Land use -1.2001e+08 dimensionless / unit
Ozone depletion -1.63422 kg CFC-11-Eq / unit
Particulate matter -0.456626 disease incidence / unit
Photochemical ozone formation -61559 kg NMVOC-Eq / unit
Resource use, fossils -1.5501e+08 MJ, net calorific value / unit
Resource use, minerals and metals -15952.2 kg Sb-Eq / unit
Water use -8.1271e+07 m3 world Eq deprived / unit
Calculation details

Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact 4e70d56a85b1 · calculated 2026-11-03 09:19 UTC. These screening results do not replace a reviewed comparative LCA.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
electric drive and buffer battery assembly, container ship
RER
electric drive and buffer battery, container ship
1
unit - Reference flow

Inputs

Technosphere inputs 7 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
market for battery, Li-ion, NMC111, rechargeable
GLO
battery, Li-ion, NMC111, rechargeable
2.54e+04
kilogram -
291448 kg CO2-Eq / unit -2.4% of total
BAFU:2025
market for used Li-ion battery
GLO
used Li-ion battery
-2.54e+04
kilogram
-74350.6 kg CO2-Eq / unit 0.6% of total
BAFU:2025
market for marine electric motor
GLO
marine electric motor
84.87
unit
5894.54 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for converter, for electric passenger car
GLO
converter, for electric passenger car
8.81e+04
kilogram
2.0042e+06 kg CO2-Eq / unit -16.4% of total
BAFU:2025
market for waste electric and electronic equipment
GLO
waste electric and electronic equipment
-8.81e+04
kilogram
-1.5948e+07 kg CO2-Eq / unit 130.6% of total
BAFU:2025
market for inverter, 500kW
GLO
inverter, 500kW
40.12
unit
491810 kg CO2-Eq / unit -4.0% of total
BAFU:2025
market for control cabinet, heat and power co-generation unit, 160kW electrical
GLO
control cabinet, heat and power co-generation unit, 160kW electrical
65.8
unit
1.0219e+06 kg CO2-Eq / unit -8.4% of total
BAFU:2025
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 1 version · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  1. Version 1.0.0
    Published

    Adds electric drive and buffer battery assembly, container ship, supplying 1 unit of electric drive and buffer battery, container ship in RER. This is…

    Published · Viewing · Latest
Show full version history table (1 version)
Version Published Reason for this version Link
Version 1.0.0 2026-11-03 Adds electric drive and buffer battery assembly, container ship, supplying 1 unit of electric drive and buffer battery, container ship in RER. This is a new catalogue entry with no earlier version for a like-for-like revision comparison. Current view
About this version

About this version

Adds electric drive and buffer battery assembly, container ship, supplying 1 unit of electric drive and buffer battery, container ship in RER. This is a new catalogue entry with no earlier version for a like-for-like revision comparison.

Release notes

Source references: https://doi.org/10.1016/j.ijhydene.2021.12.164, https://doi.org/10.1016/j.apenergy.2026.127666.

Declared licence: CC BY 4.0. Source documents and external supplier inventories retain their own terms.

Electric-drive and buffer-battery equipment for one qualified 43,000-DWT ship over 25 years; fuel-cell systems and tank are separately purchased by the ship. Battery converter assumes 1C, not verified marine power capability. Represent their materials with the native 500 kW PV inverter recipe divided by its approximately 3000 kg nominal mass.

Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content