Description
PV electrical balance-of-system provision for 1 m² of electric installation, utility scale, open ground in the RER model. It supplies the recorded electrical balance-of-system components; inverters have a separate reference.
Chemicals
Reference product electric installation, utility scale, open ground RER
Stable dataset identity
electric-installation-production-utility-scale-open-ground
1.0.1Published inventory
Process description and catalog context. View scientific metadata
PV electrical balance-of-system provision for 1 m² of electric installation, utility scale, open ground in the RER model. It supplies the recorded electrical balance-of-system components; inverters have a separate reference.
Classification, keywords, bookmarks and download counts.
Classification path: Chemicals
Log in to bookmarkSource documentation, background profiles and references.
Technical or institutional report
Götz, M., Deuber, R., Gazbour, N., Brailovsky, P. H., Nold, S., Marchand-Lasserre, M., Frischknecht, R., Khan, A. A., Bovo, G., Stucki, M. (2026). Heath, G. (Ed.), Life Cycle Inventories of Photovoltaic Systems. IEA PVPS Task 12, Report T12-33:2026. https://doi.org/10.69766/WJTE1771
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per square meter, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-23 19:43 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
electric installation production, utility scale, open ground
RER
|
electric installation, utility scale, open ground
|
1
|
square meter | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
Copper, at regional storage
RER
|
Copper, at regional storage
|
0.53
|
kilogram |
0.0833557
mol H+-Eq / square meter
86.1% of total
0.860447
kg CO2-Eq / square meter
19.7% of total
24.375
CTUe / square meter
47.1% of total
0.027963
kg P-Eq / square meter
93.7% of total
0.00565571
kg N-Eq / square meter
70.7% of total
0.0670494
mol N-Eq / square meter
69.2% of total
1.1362e-08
CTUh / square meter
77.0% of total
1.0476e-06
CTUh / square meter
92.6% of total
0.258186
kBq U235-Eq / square meter
24.6% of total
13.2505
dimensionless / square meter
53.5% of total
1.9114e-08
kg CFC-11-Eq / square meter
24.1% of total
1.9013e-07
disease incidence / square meter
55.6% of total
0.0176107
kg NMVOC-Eq / square meter
61.5% of total
11.6384
MJ, net calorific value / square meter
20.3% of total
0.000610839
kg Sb-Eq / square meter
94.9% of total
0.656686
m3 world Eq deprived / square meter
6.4% of total
BAFU:2025
|
|
|
Polyethylene, LLDPE, granulate, at plant
RER
|
Polyethylene, LLDPE, granulate, at plant
|
0.11
|
kilogram |
0.000610415
mol H+-Eq / square meter
0.6% of total
0.250653
kg CO2-Eq / square meter
5.7% of total
1.4238
CTUe / square meter
2.8% of total
1.3749e-05
kg P-Eq / square meter
0.0% of total
0.000133498
kg N-Eq / square meter
1.7% of total
0.00145869
mol N-Eq / square meter
1.5% of total
3.5866e-11
CTUh / square meter
0.2% of total
9.2866e-10
CTUh / square meter
0.1% of total
0.00842091
kBq U235-Eq / square meter
0.8% of total
0.104453
dimensionless / square meter
0.4% of total
5.7537e-09
kg CFC-11-Eq / square meter
7.2% of total
7.7120e-09
disease incidence / square meter
2.3% of total
0.000629583
kg NMVOC-Eq / square meter
2.2% of total
7.81006
MJ, net calorific value / square meter
13.6% of total
3.8682e-07
kg Sb-Eq / square meter
0.1% of total
0.0098635
m3 world Eq deprived / square meter
0.1% of total
BAFU:2025
|
|
|
Synthetic rubber, at plant
RER
|
Synthetic rubber, at plant
|
0.02
|
kilogram |
0.000157936
mol H+-Eq / square meter
0.2% of total
0.0479889
kg CO2-Eq / square meter
1.1% of total
0.291785
CTUe / square meter
0.6% of total
1.0495e-05
kg P-Eq / square meter
0.0% of total
2.7429e-05
kg N-Eq / square meter
0.3% of total
0.000278549
mol N-Eq / square meter
0.3% of total
2.0448e-11
CTUh / square meter
0.1% of total
5.9720e-10
CTUh / square meter
0.1% of total
0.0101743
kBq U235-Eq / square meter
1.0% of total
0.231823
dimensionless / square meter
0.9% of total
1.0570e-09
kg CFC-11-Eq / square meter
1.3% of total
2.6977e-09
disease incidence / square meter
0.8% of total
0.000199929
kg NMVOC-Eq / square meter
0.7% of total
1.36232
MJ, net calorific value / square meter
2.4% of total
3.3661e-07
kg Sb-Eq / square meter
0.1% of total
0.0738561
m3 world Eq deprived / square meter
0.7% of total
BAFU:2025
|
|
|
Polyethylene, LLDPE, granulate, at plant
RER
|
Polyethylene, LLDPE, granulate, at plant
|
0.02
|
kilogram |
0.000107497
mol H+-Eq / square meter
0.1% of total
0.044141
kg CO2-Eq / square meter
1.0% of total
0.250737
CTUe / square meter
0.5% of total
2.4212e-06
kg P-Eq / square meter
0.0% of total
2.3510e-05
kg N-Eq / square meter
0.3% of total
0.000256882
mol N-Eq / square meter
0.3% of total
6.3162e-12
CTUh / square meter
0.0% of total
1.6354e-10
CTUh / square meter
0.0% of total
0.00148296
kBq U235-Eq / square meter
0.1% of total
0.0183946
dimensionless / square meter
0.1% of total
1.0133e-09
kg CFC-11-Eq / square meter
1.3% of total
1.3581e-09
disease incidence / square meter
0.4% of total
0.000110872
kg NMVOC-Eq / square meter
0.4% of total
1.37539
MJ, net calorific value / square meter
2.4% of total
6.8122e-08
kg Sb-Eq / square meter
0.0% of total
0.00173701
m3 world Eq deprived / square meter
0.0% of total
BAFU:2025
|
|
|
transformer, oil-immersed, 2.5 mw
|
9.00e-05
|
unit |
0.00544453
mol H+-Eq / square meter
5.6% of total
2.0004
kg CO2-Eq / square meter
45.7% of total
5.52892
CTUe / square meter
10.7% of total
0.000526835
kg P-Eq / square meter
1.8% of total
0.00127515
kg N-Eq / square meter
15.9% of total
0.0119685
mol N-Eq / square meter
12.3% of total
2.3272e-09
CTUh / square meter
15.8% of total
2.9764e-08
CTUh / square meter
2.6% of total
0.501344
kBq U235-Eq / square meter
47.9% of total
7.06224
dimensionless / square meter
28.5% of total
3.4545e-08
kg CFC-11-Eq / square meter
43.5% of total
9.3354e-08
disease incidence / square meter
27.3% of total
0.00664093
kg NMVOC-Eq / square meter
23.2% of total
24.8566
MJ, net calorific value / square meter
43.4% of total
4.5710e-06
kg Sb-Eq / square meter
0.7% of total
5.38536
m3 world Eq deprived / square meter
52.6% of total
|
||
|
Building, hall, steel construction
CH
|
Building, hall, steel construction
|
9.00e-04
|
square meter |
0.00249316
mol H+-Eq / square meter
2.6% of total
0.259322
kg CO2-Eq / square meter
5.9% of total
1.32009
CTUe / square meter
2.6% of total
8.4463e-05
kg P-Eq / square meter
0.3% of total
0.000269
kg N-Eq / square meter
3.4% of total
0.00950792
mol N-Eq / square meter
9.8% of total
2.5450e-10
CTUh / square meter
1.7% of total
5.9448e-09
CTUh / square meter
0.5% of total
0.0642416
kBq U235-Eq / square meter
6.1% of total
0.916338
dimensionless / square meter
3.7% of total
5.3636e-09
kg CFC-11-Eq / square meter
6.8% of total
3.0158e-08
disease incidence / square meter
8.8% of total
0.000895115
kg NMVOC-Eq / square meter
3.1% of total
3.11705
MJ, net calorific value / square meter
5.4% of total
2.6560e-06
kg Sb-Eq / square meter
0.4% of total
3.83408
m3 world Eq deprived / square meter
37.4% of total
BAFU:2025
|
|
|
Nylon 66, at plant
RER
|
Nylon 66, at plant
|
7.36e-04
|
kilogram |
2.6114e-05
mol H+-Eq / square meter
0.0% of total
0.00605476
kg CO2-Eq / square meter
0.1% of total
0.00626727
CTUe / square meter
0.0% of total
3.2526e-07
kg P-Eq / square meter
0.0% of total
1.0003e-05
kg N-Eq / square meter
0.1% of total
4.9354e-05
mol N-Eq / square meter
0.1% of total
6.0261e-13
CTUh / square meter
0.0% of total
5.2151e-12
CTUh / square meter
0.0% of total
2.4082e-06
kBq U235-Eq / square meter
0.0% of total
7.1676e-05
dimensionless / square meter
0.0% of total
2.1325e-13
kg CFC-11-Eq / square meter
0.0% of total
2.5862e-10
disease incidence / square meter
0.1% of total
1.5048e-05
kg NMVOC-Eq / square meter
0.1% of total
0.0948975
MJ, net calorific value / square meter
0.2% of total
2.4470e-09
kg Sb-Eq / square meter
0.0% of total
3.3011e-06
m3 world Eq deprived / square meter
0.0% of total
BAFU:2025
|
|
|
Wire drawing, copper
RER
|
Wire drawing, copper
|
0.53
|
kilogram |
0.00364273
mol H+-Eq / square meter
3.8% of total
0.199558
kg CO2-Eq / square meter
4.6% of total
1.44299
CTUe / square meter
2.8% of total
0.00117175
kg P-Eq / square meter
3.9% of total
0.000304992
kg N-Eq / square meter
3.8% of total
0.00336693
mol N-Eq / square meter
3.5% of total
5.6152e-10
CTUh / square meter
3.8% of total
4.2414e-08
CTUh / square meter
3.7% of total
0.100876
kBq U235-Eq / square meter
9.6% of total
1.23001
dimensionless / square meter
5.0% of total
4.9927e-09
kg CFC-11-Eq / square meter
6.3% of total
9.7410e-09
disease incidence / square meter
2.8% of total
0.00147174
kg NMVOC-Eq / square meter
5.1% of total
3.40519
MJ, net calorific value / square meter
5.9% of total
2.4342e-05
kg Sb-Eq / square meter
3.8% of total
0.0851941
m3 world Eq deprived / square meter
0.8% of total
BAFU:2025
|
|
|
Extrusion, plastic pipes
RER
|
Extrusion, plastic pipes
|
0.15
|
kilogram |
0.000155038
mol H+-Eq / square meter
0.2% of total
0.0377642
kg CO2-Eq / square meter
0.9% of total
0.102398
CTUe / square meter
0.2% of total
1.9589e-05
kg P-Eq / square meter
0.1% of total
2.1505e-05
kg N-Eq / square meter
0.3% of total
0.000207843
mol N-Eq / square meter
0.2% of total
4.9247e-11
CTUh / square meter
0.3% of total
2.4268e-10
CTUh / square meter
0.0% of total
0.0282896
kBq U235-Eq / square meter
2.7% of total
0.724328
dimensionless / square meter
2.9% of total
9.0203e-10
kg CFC-11-Eq / square meter
1.1% of total
1.2285e-09
disease incidence / square meter
0.4% of total
8.7179e-05
kg NMVOC-Eq / square meter
0.3% of total
0.692331
MJ, net calorific value / square meter
1.2% of total
7.0495e-08
kg Sb-Eq / square meter
0.0% of total
0.0245764
m3 world Eq deprived / square meter
0.2% of total
BAFU:2025
|
|
|
Transport, freight, lorry, fleet average
RER
|
Transport, freight, lorry, fleet average
|
0.41
|
ton kilometer |
0.000324983
mol H+-Eq / square meter
0.3% of total
0.0776172
kg CO2-Eq / square meter
1.8% of total
0.220834
CTUe / square meter
0.4% of total
7.3877e-06
kg P-Eq / square meter
0.0% of total
0.000133653
kg N-Eq / square meter
1.7% of total
0.00138887
mol N-Eq / square meter
1.4% of total
2.7261e-11
CTUh / square meter
0.2% of total
6.0265e-10
CTUh / square meter
0.1% of total
0.00896501
kBq U235-Eq / square meter
0.9% of total
0.458695
dimensionless / square meter
1.9% of total
2.8892e-09
kg CFC-11-Eq / square meter
3.6% of total
2.3985e-09
disease incidence / square meter
0.7% of total
0.000495778
kg NMVOC-Eq / square meter
1.7% of total
1.12509
MJ, net calorific value / square meter
2.0% of total
1.8189e-07
kg Sb-Eq / square meter
0.0% of total
0.090002
m3 world Eq deprived / square meter
0.9% of total
BAFU:2025
|
|
|
Transport, freight, rail
RER
|
Transport, freight, rail
|
0.41
|
ton kilometer |
3.0068e-05
mol H+-Eq / square meter
0.0% of total
0.00686802
kg CO2-Eq / square meter
0.2% of total
0.0180884
CTUe / square meter
0.0% of total
4.1469e-06
kg P-Eq / square meter
0.0% of total
9.9968e-06
kg N-Eq / square meter
0.1% of total
0.000100171
mol N-Eq / square meter
0.1% of total
8.2698e-12
CTUh / square meter
0.1% of total
8.7363e-11
CTUh / square meter
0.0% of total
0.00673236
kBq U235-Eq / square meter
0.6% of total
0.126979
dimensionless / square meter
0.5% of total
1.6698e-10
kg CFC-11-Eq / square meter
0.2% of total
3.0944e-10
disease incidence / square meter
0.1% of total
3.1946e-05
kg NMVOC-Eq / square meter
0.1% of total
0.132762
MJ, net calorific value / square meter
0.2% of total
1.5390e-08
kg Sb-Eq / square meter
0.0% of total
0.00389096
m3 world Eq deprived / square meter
0.0% of total
BAFU:2025
|
|
|
Disposal, treatment of cables
GLO
|
Disposal, treatment of cables
|
0.68
|
kilogram |
0.000415214
mol H+-Eq / square meter
0.4% of total
0.584537
kg CO2-Eq / square meter
13.4% of total
16.7693
CTUe / square meter
32.4% of total
4.2864e-05
kg P-Eq / square meter
0.1% of total
0.000132132
kg N-Eq / square meter
1.7% of total
0.00132372
mol N-Eq / square meter
1.4% of total
1.0500e-10
CTUh / square meter
0.7% of total
2.9696e-09
CTUh / square meter
0.3% of total
0.0587671
kBq U235-Eq / square meter
5.6% of total
0.654359
dimensionless / square meter
2.6% of total
3.6528e-09
kg CFC-11-Eq / square meter
4.6% of total
2.6252e-09
disease incidence / square meter
0.8% of total
0.00045369
kg NMVOC-Eq / square meter
1.6% of total
1.71944
MJ, net calorific value / square meter
3.0% of total
3.1074e-07
kg Sb-Eq / square meter
0.0% of total
0.0779296
m3 world Eq deprived / square meter
0.8% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
pv-2026-uvek-heroku-drafts-20260915. pv-2026-uvek-publication-20260915. Curator-led source-backed PV 2026 release, not a community peer-review checklist. 317 UVEK 2025 inventories and 7,296 exchanges validated; nine documented water-balance/fuel-CO2 warnings…
SupersededUtility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight.
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-11-03 | Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. | Current view |
| Version 1.0.0 Superseded | Published 2026-09-15 | pv-2026-uvek-heroku-drafts-20260915. pv-2026-uvek-publication-20260915. Curator-led source-backed PV 2026 release, not a community peer-review checklist. 317 UVEK 2025 inventories and 7,296 exchanges validated; nine documented water-balance/fuel-CO2 warnings retained. Approved proxies and biosphere conversion limitations remain documented. Unknown quality scores are not invented. Data-adaptation changes: native UVEK suppliers restored; approved geographic and transport proxies retained; CLIC ecoinvent 3.10 biosphere conventions applied. No claim of exact reproduction of the report's impact assessment results. | Open version |
Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight.
Other source freight arithmetic and route-distance inconsistencies remain; cable-treatment composition is not fully verified.
Source: https://doi.org/10.69766/WJTE1771, https://doi.org/10.69766/WJTE1771.
Declared foreground licence: CC-BY-NC-SA-4.0. Source publications and external supplier inventories retain their own terms.
Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Transport, freight, lorry, fleet average (technosphere / RER / ton kilometer) | Amount | 0.820592117390257 | 0.41081398122663076 | The quantity of Transport, freight, lorry, fleet average follows the selected material or process reference. Only transported material mass belongs in freight, and the sheath belongs in the installation’s disposal boundary. Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. |
| Transport, freight, lorry, fleet average (technosphere / RER / ton kilometer) | Inventory comment | IEA PVPS T12-33:2026, X-electric-utility!L17. (4,5,na,na,na,na); Standard distance 60km incl. disposal Native preparation: exact_source_identity; source-to-draft amount factor 1. Original calculation (numeric amount used): =600/1000*SUM(L8:L16) |
Exclude separately purchased wire-drawing and extrusion services from transported cargo, while retaining those manufacturing services; this is the bounded historical source correction, not a complete freight validation. Historical exchange note: IEA PVPS T12-33:2026, X-electric-utility!L17. (4,5,na,na,na,na); Standard distance 60km incl. disposal Native preparation: exact_source_identity; source-to-draft amount factor 1. Original calculation (numeric amount used): =600/1000*SUM(L8:L16) |
The annotation now explains the role and assumptions of Transport, freight, lorry, fleet average within this inventory. Only transported material mass belongs in freight, and the sheath belongs in the installation’s disposal boundary. Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. |
| Transport, freight, lorry, fleet average (technosphere / RER / ton kilometer) | Loc | -0.1977291049301848 | -0.8896147673622113 | The lognormal location is ln(|0.410813981|) = -0.889614767, so the distribution is centred on this nominal quantity. Its relative spread is unchanged. |
| Transport, freight, rail (technosphere / RER / ton kilometer) | Amount | 0.5471121880411728 | 0.41051947598663074 | The quantity of Transport, freight, rail follows the selected material or process reference. Only transported material mass belongs in freight, and the sheath belongs in the installation’s disposal boundary. Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. |
| Transport, freight, rail (technosphere / RER / ton kilometer) | Inventory comment | IEA PVPS T12-33:2026, X-electric-utility!L18. (4,5,na,na,na,na); Standard distances 200km (metals 600km) Native preparation: exact_source_identity; source-to-draft amount factor 1. Original calculation (numeric amount used): =0.6*SUM(L8:L13)+0.2*SUM(L14:L16) |
Exclude separately purchased wire-drawing and extrusion services from transported cargo, while retaining those manufacturing services; this is the bounded historical source correction, not a complete freight validation. Historical exchange note: IEA PVPS T12-33:2026, X-electric-utility!L18. (4,5,na,na,na,na); Standard distances 200km (metals 600km) Native preparation: exact_source_identity; source-to-draft amount factor 1. Original calculation (numeric amount used): =0.6*SUM(L8:L13)+0.2*SUM(L14:L16) |
The annotation now explains the role and assumptions of Transport, freight, rail within this inventory. Only transported material mass belongs in freight, and the sheath belongs in the installation’s disposal boundary. Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. |
| Transport, freight, rail (technosphere / RER / ton kilometer) | Loc | -0.6031014006222544 | -0.8903319066678985 | The lognormal location is ln(|0.410519476|) = -0.890331907, so the distribution is centred on this nominal quantity. Its relative spread is unchanged. |
| Disposal, treatment of cables (technosphere / GLO / kilogram) | Amount | 0.6632281631727104 | 0.6829635603727103 | The quantity of Disposal, treatment of cables follows the selected material or process reference. Only transported material mass belongs in freight, and the sheath belongs in the installation’s disposal boundary. Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. |
| Disposal, treatment of cables (technosphere / GLO / kilogram) | Inventory comment | IEA PVPS T12-33:2026, X-electric-utility!L19. (2,3,1,3,1,4); Native preparation: exact_source_identity; source-to-draft amount factor 1. Original calculation (numeric amount used): =SUM(L8:L10) |
Include the separately purchased AC outer sheath: cable retirement = L8+L9+L10+L11; preserve the positive UVEK treatment-demand convention and exact existing supplier. Historical exchange note: IEA PVPS T12-33:2026, X-electric-utility!L19. (2,3,1,3,1,4); Native preparation: exact_source_identity; source-to-draft amount factor 1. Original calculation (numeric amount used): =SUM(L8:L10) |
The annotation now explains the role and assumptions of Disposal, treatment of cables within this inventory. Only transported material mass belongs in freight, and the sheath belongs in the installation’s disposal boundary. Utility-PV electrical installation now includes the omitted AC cable-sheath retirement and excludes fabrication-service quantities from material freight. |
| Disposal, treatment of cables (technosphere / GLO / kilogram) | Loc | -0.4106362104826071 | -0.3813137731439875 | The lognormal location is ln(|0.68296356|) = -0.381313773, so the distribution is centred on this nominal quantity. Its relative spread is unchanged. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Version metadata | Data collection period end year | 2026 | Not set | No explanation was recorded for this change. |
| Version metadata | Data collection period start year | 2022 | Not set | |
| Version metadata | Source | Götz et al. (2026), Life Cycle Inventories of Photovoltaic Systems, IEA PVPS Task 12, Report T12-33:2026. https://doi.org/10.69766/WJTE1771; inventory locator: X-electric-utility, column L. | Götz, M., Deuber, R., Gazbour, N., Brailovsky, P. H., Nold, S., Marchand-Lasserre, M., Frischknecht, R., Khan, A. A., Bovo, G., Stucki, M. (2026). Heath, G. (Ed.), Life Cycle Inventories of Photovoltaic Systems. IEA PVPS Task 12, Report T12-33:2026. https://doi.org/10.69766/WJTE1771 | |
| Version metadata | Contributors, publications, projects and supporting evidence | Funding: 1. Project: Url: https://iea-pvps.org/key-topics/t12-lci-pv-systems-2026/ Funding: 1. Project: Name: IEA PVPS Task 12: Life Cycle Inventories of Photovoltaic Systems 2026 Funding: 1. Project: Acronym: IEA PVPS Task 12 Funding: 1. Project: Relation: source_study Funding: 1. Project: Grant identifier: Not set Funding: 1. Organization: Ror: https://ror.org/020ddnn22 Funding: 1. Organization: Url: Not set Funding: 1. Organization: Name: Swiss Federal Office of Energy Funding: 1. Award identifier: SI/502610-01 Evidence: 1. Origin: source_import Evidence: 1. Target field: publications Evidence: 1. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 1. Source location: original_doi Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: publications Evidence: 2. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 2. Source location: original_citation Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: editor_verification Evidence: 3. Target field: publications Evidence: 3. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 3. Source location: registry-records.json: requested_doi=10.69766/wjte1771, metadata.published.date-parts Evidence: 3. Source reference: https://api.crossref.org/works/10.69766%2FWJTE1771 Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 4. Source location: Suggested citation and authors, PDF pp. 2–4 Evidence: 4. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 5. Origin: editor_verification Evidence: 5. Target field: projects Evidence: 5. Qualification: SFOE supports the source report. German OekodesignPV funding specifically supports simulated Chapter 4 data, not all industrial/retained inventories. No assertion about CLIC or original historical measurements. Evidence: 5. Source location: Acknowledgement, PDF p. 6 Evidence: 5. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 6. Origin: editor_verification Evidence: 6. Target field: funding Evidence: 6. Qualification: Source-study report/development funding only; locally derived variants excluded. Evidence: 6. Source location: Acknowledgement, PDF p. 6 Evidence: 6. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 7. Origin: source_import Evidence: 7. Target field: use_limitations Evidence: 7. Qualification: Existing documented limitation only; no new scientific assumption. Evidence: 7. Source location: description Evidence: 7. Source reference: Existing published CLIC inventory documentation Evidence: 8. Origin: source_import Evidence: 8. Target field: data_period_start_year Evidence: 8. Qualification: Literal workbook-declared interval, not evidence that all inputs were measured within these bounds. Retained older inputs and partial updates remain qualified. Evidence: 8. Source location: description Evidence: 8. Source reference: Existing published CLIC inventory documentation Evidence: 9. Origin: source_import Evidence: 9. Target field: data_period_end_year Evidence: 9. Qualification: Literal workbook-declared interval, not evidence that all inputs were measured within these bounds. Retained older inputs and partial updates remain qualified. Evidence: 9. Source location: description Evidence: 9. Source reference: Existing published CLIC inventory documentation Evidence: 10. Origin: source_import Evidence: 10. Target field: system_boundary Evidence: 10. Qualification: Own-row scope declaration only; no whole life cycle is inferred from the subject technology. Evidence: 10. Source location: description Evidence: 10. Source reference: Existing published CLIC inventory documentation Evidence: 11. Origin: source_import Evidence: 11. Target field: included_life_cycle_stages Evidence: 11. Qualification: Directly represented operation only. Tags are supported inclusions, not a claim that other stages are absent. Evidence: 11. Source location: name Evidence: 11. Source reference: Existing published CLIC inventory documentation Evidence: 12. Origin: editor_verification Evidence: 12. Target field: funding Evidence: 12. Qualification: Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope. Evidence: 12. Source location: Organization identity and registered names Evidence: 12. Source reference: https://api.ror.org/v2/organizations/020ddnn22 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: publications Evidence: 13. Qualification: Ordered publication byline and abbreviated affiliations are verified from the report. ROR identities are independently verified; Certisolis uses its official website. Editor and task-manager roles are not inserted as authors. These are not new inventory contributors and publication year 2026 is not an inventory reference year. Evidence: 13. Source location: AUTHORS page and suggested citation, July 2026 report Evidence: 13. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 14. Origin: editor_verification Evidence: 14. Target field: publications Evidence: 14. Qualification: Compared 13 exchange references with the pinned published workbook. Every nonzero numeric source exchange row in the selected column is represented. Cached source quantities, unit adapters and documented CLIC adaptations are distinguished; this does not validate background supplier equivalence, uncertainty distributions or the complete scientific model. Source-specific scientific metadata are traceable through X-Process!FS (process Z-PV-238). Source validity dates are not measurement periods. The source freight expressions sum kg, transformer pieces and hall square metres. The source lorry formula uses 600 km whereas its note says 60 km. Version 1.0.1 removes fabrication services from cargo but retains this mixed-unit subtotal. Its bounded historical correction is not a complete freight validation; resolve equipment transport boundaries and the distance conflict before proposing a new quantity. Evidence: 14. Source location: X-electric-utility!L; exchange-specific cell comparison retained in the curated update plan Evidence: 14. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-LCI-PV-SupplyChains.xlsx Projects: 1. Url: https://iea-pvps.org/key-topics/t12-lci-pv-systems-2026/ Projects: 1. Name: IEA PVPS Task 12: Life Cycle Inventories of Photovoltaic Systems 2026 Projects: 1. Acronym: IEA PVPS Task 12 Projects: 1. Relation: source_study Projects: 1. Grant identifier: Not set Publications: 1. Doi: 10.69766/wjte1771 Publications: 1. Url: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Publications: 1. Title: Life Cycle Inventories of Photovoltaic Systems Publications: 1. Scientific authors: 1. Name: Michael Götz Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/05pmsvm27 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Name: ZHAW Publications: 1. Scientific authors: 2. Name: Reto Deuber Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/05pmsvm27 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Name: ZHAW Publications: 1. Scientific authors: 3. Name: Nouha Gazbour Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/00jjx8s55 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Name: CEA Publications: 1. Scientific authors: 4. Name: Peter H. Brailovsky Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02kfzvh91 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Fraunhofer ISE Publications: 1. Scientific authors: 5. Name: Sebastian Nold Publications: 1. Scientific authors: 5. Orcid: Not set Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02kfzvh91 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Fraunhofer ISE Publications: 1. Scientific authors: 6. Name: Mathilde Marchand-Lasserre Publications: 1. Scientific authors: 6. Orcid: Not set Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/04y8cs423 Publications: 1. Scientific authors: 6. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 6. Affiliations: 1. Name: MINES ParisTech Publications: 1. Scientific authors: 7. Name: Rolf Frischknecht Publications: 1. Scientific authors: 7. Orcid: Not set Publications: 1. Scientific authors: 7. Affiliations: 1. Ror: https://ror.org/03c1wwn39 Publications: 1. Scientific authors: 7. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 7. Affiliations: 1. Name: Treeze ltd. Publications: 1. Scientific authors: 8. Name: Abeer Ali Khan Publications: 1. Scientific authors: 8. Orcid: Not set Publications: 1. Scientific authors: 8. Affiliations: 1. Ror: https://ror.org/04hjzh827 Publications: 1. Scientific authors: 8. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 8. Affiliations: 1. Name: First Solar Publications: 1. Scientific authors: 9. Name: Gisèle Bovo Publications: 1. Scientific authors: 9. Orcid: Not set Publications: 1. Scientific authors: 9. Affiliations: 1. Ror: Not set Publications: 1. Scientific authors: 9. Affiliations: 1. Url: https://www.certisolis.com/ Publications: 1. Scientific authors: 9. Affiliations: 1. Name: Certisolis Publications: 1. Scientific authors: 10. Name: Matthias Stucki Publications: 1. Scientific authors: 10. Orcid: Not set Publications: 1. Scientific authors: 10. Affiliations: 1. Ror: https://ror.org/05pmsvm27 Publications: 1. Scientific authors: 10. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 10. Affiliations: 1. Name: ZHAW Publications: 1. Citation: Götz, M., Deuber, R., Gazbour, N., Brailovsky, P. H., Nold, S., Marchand-Lasserre, M., Frischknecht, R., Khan, A. A., Bovo, G., Stucki, M. (2026). Heath, G. (Ed.), Life Cycle Inventories of Photovoltaic Systems. IEA PVPS Task 12, Report T12-33:2026. https://doi.org/10.69766/WJTE1771 Publications: 1. Relation: primary_source Publications: 1. Source type: technical_report Publications: 1. Publication year: 2026 |
Funding: 1. Project: Url: https://iea-pvps.org/key-topics/t12-lci-pv-systems-2026/ Funding: 1. Project: Name: IEA PVPS Task 12: Life Cycle Inventories of Photovoltaic Systems 2026 Funding: 1. Project: Acronym: IEA PVPS Task 12 Funding: 1. Project: Relation: source_study Funding: 1. Project: Grant identifier: Not set Funding: 1. Organization: Ror: https://ror.org/020ddnn22 Funding: 1. Organization: Url: Not set Funding: 1. Organization: Name: Swiss Federal Office of Energy Funding: 1. Award identifier: SI/502610-01 Evidence: 1. Origin: source_import Evidence: 1. Target field: publications Evidence: 1. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 1. Source location: original_doi Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: publications Evidence: 2. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 2. Source location: original_citation Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: editor_verification Evidence: 3. Target field: publications Evidence: 3. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 3. Source location: registry-records.json: requested_doi=10.69766/wjte1771, metadata.published.date-parts Evidence: 3. Source reference: https://api.crossref.org/works/10.69766%2FWJTE1771 Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Publication in 2026 does not refresh older measurements. Evidence: 4. Source location: Suggested citation and authors, PDF pp. 2–4 Evidence: 4. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 5. Origin: editor_verification Evidence: 5. Target field: projects Evidence: 5. Qualification: SFOE supports the source report. German OekodesignPV funding specifically supports simulated Chapter 4 data, not all industrial/retained inventories. No assertion about CLIC or original historical measurements. Evidence: 5. Source location: Acknowledgement, PDF p. 6 Evidence: 5. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 6. Origin: editor_verification Evidence: 6. Target field: funding Evidence: 6. Qualification: Source-study report/development funding only; locally derived variants excluded. Evidence: 6. Source location: Acknowledgement, PDF p. 6 Evidence: 6. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 7. Origin: source_import Evidence: 7. Target field: included_life_cycle_stages Evidence: 7. Qualification: Directly represented operation only. Tags are supported inclusions, not a claim that other stages are absent. Evidence: 7. Source location: name Evidence: 7. Source reference: Existing published CLIC inventory documentation Evidence: 8. Origin: source_import Evidence: 8. Target field: use_limitations Evidence: 8. Qualification: Existing documented limitation only; no new scientific assumption. Evidence: 8. Source location: inventory_snapshot.comment Evidence: 8. Source reference: Existing published CLIC inventory documentation Evidence: 9. Origin: source_import Evidence: 9. Target field: system_boundary Evidence: 9. Qualification: Own-row scope declaration only; no whole life cycle is inferred from the subject technology. Evidence: 9. Source location: inventory_snapshot.comment Evidence: 9. Source reference: Existing published CLIC inventory documentation Evidence: 10. Origin: editor_verification Evidence: 10. Target field: funding Evidence: 10. Qualification: Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope. Evidence: 10. Source location: Organization identity and registered names Evidence: 10. Source reference: https://api.ror.org/v2/organizations/020ddnn22 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: publications Evidence: 11. Qualification: Ordered publication byline and abbreviated affiliations are verified from the report. ROR identities are independently verified; Certisolis uses its official website. Editor and task-manager roles are not inserted as authors. These are not new inventory contributors and publication year 2026 is not an inventory reference year. Evidence: 11. Source location: AUTHORS page and suggested citation, July 2026 report Evidence: 11. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 12. Origin: editor_verification Evidence: 12. Target field: publications Evidence: 12. Qualification: Compared 13 exchange references with the pinned published workbook. Every nonzero numeric source exchange row in the selected column is represented. Cached source quantities, unit adapters and documented CLIC adaptations are distinguished; this does not validate background supplier equivalence, uncertainty distributions or the complete scientific model. Source-specific scientific metadata are traceable through X-Process!FS (process Z-PV-238). Source validity dates are not measurement periods. The source freight expressions sum kg, transformer pieces and hall square metres. The source lorry formula uses 600 km whereas its note says 60 km. Version 1.0.1 removes fabrication services from cargo but retains this mixed-unit subtotal. Its bounded historical correction is not a complete freight validation; resolve equipment transport boundaries and the distance conflict before proposing a new quantity. Evidence: 12. Source location: X-electric-utility!L; exchange-specific cell comparison retained in the curated update plan Evidence: 12. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-LCI-PV-SupplyChains.xlsx Evidence: 13. Origin: editor_verification Evidence: 13. Target field: methodology_notes Evidence: 13. Qualification: Manifest-verified historical decision NB-PV-UTILITY-064-065. Preserve the identified prior repair and its source/profile qualifications. Exact agreement is not blanket approval of every other amount, provider, uncertainty or future version. Original decision rationale: Include omitted AC-sheath cable retirement and remove fabrication-service quantities from freight in the same utility-PV electric installation, preserving all physical inputs, providers, signs and original UVEK 2025 / biosphere 3.10 pairing. Original qualification: Remaining source freight arithmetic includes transformer counts/building area as kg (0.0005940871430045899 tkm/m2) and has a 60/600 km narrative conflict. Keep those unresolved rather than invent equipment masses or routes. Cable-tie retirement and generic cable treatment composition remain unverified. Evidence: 13. Source location: Historical preservation register P013/P014 or scoped H-series review; original encoding and approval boundaries retained Evidence: 13. Source reference: Manifest-verified prior correction/source/migration decisions and exact archive guards Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-3480. Design capacity: Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: fields/design_capacity Evidence: 14. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-3480. Design capacity unit: Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: fields/design_capacity_unit Evidence: 15. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-3480. Capacity factor (%): Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: fields/capacity_factor_percent Evidence: 16. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-3480. Annual production volume: Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: fields/annual_production_volume Evidence: 17. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-3480. Annual production volume unit: Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: fields/annual_production_volume_unit Evidence: 18. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 19. Origin: editor_verification Evidence: 19. Target field: technology_description Evidence: 19. Qualification: Technical-characterisation review TC-3480. Annual production volume year: Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 19. Source location: fields/annual_production_volume_year Evidence: 19. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 20. Origin: editor_verification Evidence: 20. Target field: technology_description Evidence: 20. Qualification: Technical-characterisation review TC-3480. Plant or represented-asset lifetime (years): Unspecified. Basis: No additional current-context value established for this reference. Source validity, model years, population coverage and product/service denominator retain separate roles. Evidence classification: pinned source card and guarded prior scope review. Confidence: high for existing model scope not observed plant performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 20. Source location: fields/plant_lifetime_years Evidence: 20. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 21. Origin: editor_verification Evidence: 21. Target field: technology_description Evidence: 21. Qualification: Technical-characterisation review TC-3480. Commercial maturity stage: mature_commercial. Basis: Retain the earlier curator assessment of the established underlying commercial industrial route; market/recycling models and simulated factory configurations do not establish deployment of the exact CLIC model. Obsolescence of a commercial route is not low readiness. Evidence classification: existing curator estimate reassessed against source scope. Confidence: medium curator judgement not publisher rating. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 21. Source location: X-Process!FS Evidence: 21. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 22. Origin: editor_verification Evidence: 22. Target field: technology_description Evidence: 22. Qualification: Technical-characterisation review TC-3480. Technology readiness level: 9. Basis: Retain the earlier curator assessment of the established underlying commercial industrial route; market/recycling models and simulated factory configurations do not establish deployment of the exact CLIC model. Obsolescence of a commercial route is not low readiness. Evidence classification: existing curator estimate reassessed against source scope. Confidence: medium curator judgement not publisher rating. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 22. Source location: X-Process!FS Evidence: 22. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 23. Origin: editor_verification Evidence: 23. Target field: technology_description Evidence: 23. Qualification: Technical-characterisation review TC-3480. Technological representativeness: 3. Basis: Workbook X-electric/X-electric-utility: modelled electrical balance of system for a reference 10 MW p plant. Inventory is per m², so the whole plant rating is not assigned to this component. Evidence classification: existing curator estimate reassessed against source scope. Confidence: medium curator judgement not publisher rating. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 23. Source location: X-Process!FS Evidence: 23. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 24. Origin: editor_verification Evidence: 24. Target field: technology_description Evidence: 24. Qualification: Technical-characterisation review TC-3480. Geographical representativeness: 3. Basis: Workbook X-electric/X-electric-utility: modelled electrical balance of system for a reference 10 MW p plant. Inventory is per m², so the whole plant rating is not assigned to this component. Evidence classification: existing curator estimate reassessed against source scope. Confidence: medium curator judgement not publisher rating. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 24. Source location: X-Process!FS Evidence: 24. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Evidence: 25. Origin: editor_verification Evidence: 25. Target field: technology_description Evidence: 25. Qualification: Technical-characterisation review TC-3480. Temporal representativeness: 2. Basis: Workbook X-electric/X-electric-utility: modelled electrical balance of system for a reference 10 MW p plant. Inventory is per m², so the whole plant rating is not assigned to this component. Evidence classification: existing curator estimate reassessed against source scope. Confidence: medium curator judgement not publisher rating. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 25. Source location: X-Process!FS Evidence: 25. Source reference: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Projects: 1. Url: https://iea-pvps.org/key-topics/t12-lci-pv-systems-2026/ Projects: 1. Name: IEA PVPS Task 12: Life Cycle Inventories of Photovoltaic Systems 2026 Projects: 1. Acronym: IEA PVPS Task 12 Projects: 1. Relation: source_study Projects: 1. Grant identifier: Not set Publications: 1. Doi: 10.69766/wjte1771 Publications: 1. Url: https://iea-pvps.org/wp-content/uploads/2026/07/IEA-PVPS-T12-33-2026-REPORT-LCI-2026.pdf Publications: 1. Title: Life Cycle Inventories of Photovoltaic Systems Publications: 1. Scientific authors: 1. Name: Michael Götz Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/05pmsvm27 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Name: ZHAW Publications: 1. Scientific authors: 2. Name: Reto Deuber Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/05pmsvm27 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Name: ZHAW Publications: 1. Scientific authors: 3. Name: Nouha Gazbour Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/00jjx8s55 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Name: CEA Publications: 1. Scientific authors: 4. Name: Peter H. Brailovsky Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02kfzvh91 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Fraunhofer ISE Publications: 1. Scientific authors: 5. Name: Sebastian Nold Publications: 1. Scientific authors: 5. Orcid: Not set Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02kfzvh91 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Fraunhofer ISE Publications: 1. Scientific authors: 6. Name: Mathilde Marchand-Lasserre Publications: 1. Scientific authors: 6. Orcid: Not set Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/04y8cs423 Publications: 1. Scientific authors: 6. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 6. Affiliations: 1. Name: MINES ParisTech Publications: 1. Scientific authors: 7. Name: Rolf Frischknecht Publications: 1. Scientific authors: 7. Orcid: Not set Publications: 1. Scientific authors: 7. Affiliations: 1. Ror: https://ror.org/03c1wwn39 Publications: 1. Scientific authors: 7. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 7. Affiliations: 1. Name: Treeze ltd. Publications: 1. Scientific authors: 8. Name: Abeer Ali Khan Publications: 1. Scientific authors: 8. Orcid: Not set Publications: 1. Scientific authors: 8. Affiliations: 1. Ror: https://ror.org/04hjzh827 Publications: 1. Scientific authors: 8. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 8. Affiliations: 1. Name: First Solar Publications: 1. Scientific authors: 9. Name: Gisèle Bovo Publications: 1. Scientific authors: 9. Orcid: Not set Publications: 1. Scientific authors: 9. Affiliations: 1. Ror: Not set Publications: 1. Scientific authors: 9. Affiliations: 1. Url: https://www.certisolis.com/ Publications: 1. Scientific authors: 9. Affiliations: 1. Name: Certisolis Publications: 1. Scientific authors: 10. Name: Matthias Stucki Publications: 1. Scientific authors: 10. Orcid: Not set Publications: 1. Scientific authors: 10. Affiliations: 1. Ror: https://ror.org/05pmsvm27 Publications: 1. Scientific authors: 10. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 10. Affiliations: 1. Name: ZHAW Publications: 1. Citation: Götz, M., Deuber, R., Gazbour, N., Brailovsky, P. H., Nold, S., Marchand-Lasserre, M., Frischknecht, R., Khan, A. A., Bovo, G., Stucki, M. (2026). Heath, G. (Ed.), Life Cycle Inventories of Photovoltaic Systems. IEA PVPS Task 12, Report T12-33:2026. https://doi.org/10.69766/WJTE1771 Publications: 1. Relation: primary_source Publications: 1. Source type: technical_report Publications: 1. Publication year: 2026 |
|
| Version metadata | Description | Source-traceable UVEK 2025 inventory. Reference flow: 1 square meter. Materials and packaging for the production of cabling and transformer station for a utility scale PV system. Inverters are not included. Disposal of the product after use. Production of different components of the electric installation for a utility scale photovoltaic plant. Electric installation Original technosphere quantities and waste-service signs restored. Biosphere uses the CLIC ecoinvent 3.10 profile; regional water metadata is retained but its regional characterization is not reproduced. No claim of exact reproduction of report impact results. License: CC BY-NC-SA 4.0 (https://creativecommons.org/licenses/by-nc-sa/4.0/). The report's Licence Notice and Use Restrictions also states exclusions for separately credited material and restrictions on AI training and text/data mining. See the cited source notice; this release does not broaden those terms. CLIC metadata curation (2026-09-17): TRL 9 and mature-commercial status are curator estimates of the established underlying industrial route(s), not publisher-assigned ratings or evidence that a particular modelled plant exists. Representativeness estimates (1 best, 5 weakest): technology 3, geography 3, temporal 2. Workbook X-electric/X-electric-utility: modelled electrical balance of system for a reference 10 MWp plant. Inventory is per m², so the whole plant rating is not assigned to this component. No defensible dataset-specific plant capacity, utilization, annual output or lifetime is stated for this reference flow. Industry totals and sample coverage are not plant measurements. Unreported characterization fields remain blank. Source: IEA PVPS T12-33:2026, DOI 10.69766/WJTE1771; X-electric-utility, column L. Metadata: X-Process!FS; workbook period 2022-2026. |
PV electrical balance-of-system provision for 1 m² of electric installation, utility scale, open ground in the RER model. It supplies the recorded electrical balance-of-system components; inverters have a separate reference. | Describe electric installation production, utility scale, open ground by its actual reference flow, recorded inputs and applicable source qualifications instead of curation instructions and historical decision logs. |
| Version metadata | Intended application | Not set | Electrical balance-of-system supply within the matching installation model, preserving its declared plant-unit or module-area basis. | Apply reviewed discovery metadata and change explanations from the curated release. |
| Version metadata | Methodology and allocation explanation | Not set | Inventory basis The reference uses the retained UVEK 2025 cut-off background and CLIC ecoinvent 3.10 biosphere profile. Regional water metadata is retained; its regional characterization is not reproduced by this profile. Source process assumptions Production of different components of the electric installation for a utility scale photovoltaic plant. Source validity The source metadata gives a validity interval of 2022–2026. It is not an independently verified measurement period; publication of the report in 2026 does not refresh the underlying data. Source sampling Hypothetical 10 MWp ground-mounted PV system (10 MWp DC, 7.5 MVA AC); 22 240 modules (450 Wp, 1.998 m²/module); 80 string inverters; 4 × 2.5 MVA (2500 kVA) transformer stations (slightly oversized relative to the 7.5 MVA AC sizing at installation level); covered ground area 69 600 m² (300 × 232 m). Functional unit: 1 m² module area (44 438 m² total). Cradle-to-gate; electrical BoS only (inverters not included). Cable assumptions: DC cable 222 300 m (Lapp H1Z2Z2-K 1×6 mm²); AC cable 12 000 m (FG16M16-flex 1×95 mm²). Transformer stations: 4 units, buildings 4 × 10 m² = 40 m². Cable ties: 20 per table × 570 tables. All cable lengths and component quantities based on manufacturer datasheets. Electrical material boundary The AC-sheath cable retirement is included, and freight excludes fabrication-service quantities. These existing physical-boundary choices are retained with the current material bill and treatment signs. Inventory trace X-electric-utility, column L. Metadata: X-Process!FS. |
|
| Version metadata | System boundary | Materials and packaging for the production of cabling and transformer station for a utility scale PV system. Inverters are not included. Disposal of the product after use. | The recorded cabling, electrical equipment, packaging and included end-of-life handling. Inverters are excluded from this electrical-installation reference. Source coverage Materials and packaging for the production of cabling and transformer station for a utility scale PV system. Inverters are not included. Disposal of the product after use. |
|
| Version metadata | Technology description | Not set | Electric installation | |
| Version metadata | Limitations on use | No claim of exact reproduction of report impact results. | The source report does not establish exact reproduction of its impact results with this background/profile pairing. Recorded TRL, maturity and representativeness ratings are curator estimates of the underlying route, not publisher-assigned ratings or confirmation that the exact modelled plant exists. Source production totals, sample coverage and rated throughput are not measured annual output of this dataset’s plant. A source uncertainty annotation of ‘None’ does not establish zero exchange uncertainty. Freight and treatment qualifications The remaining source freight subtotal is 0.0005940871430045899 tkm/m² and still treats transformer counts/building area as kg. The narrative has a 60/600 km distance conflict. Cable-tie retirement and the composition represented by generic cable treatment remain unverified; these gaps do not establish new equipment masses or routes. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content