Material and simplified assembly reference for 1 kg asynchronous traction motor, adapted to rail using the passenger-car IM2 composition in Hsieh et al. (2026). The selected figure shares are normalized by their rounded 100.05% sum. Generic shaping, an epoxy insulation proxy and assembly electricity represent a partial manufacturing model.
Dataset details
Classification, keywords, bookmarks and download counts.
Metadata & sourcesMethods, scope, reference years, publications, contributors, projects and funding.
Source
Source documentation, background profiles and references.
Other
Supporting sources:
Meng-Ju Hsieh; Anders Nordelöf; Emma Grunditz; Torbjörn Thiringer (2026). Life cycle assessment of electric traction induction machines. https://doi.org/10.1007/s11367-026-02610-7
Reference years, modelling and allocation methods, contributors, publications, projects and funding.
Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
Source publication year
Not specified
Inventory reference year
Not specified
Foreground modelling approach
Not specified
Allocated product inventory
Not specified
Allocation or multifunctionality treatment
Not specified
Inventory contributions
Not specified
Projects
Not specified
Funding
Not specified
Methodology notes
The passenger-car IM2 reference has copper stator windings, aluminium rotor conductors, 62.9 kg total mass and 100 kW peak power. Its Figure S7 gives aluminium 37.4%, electrical steel 46.3%, copper 10%, low-alloy medium-carbon steel 3.93% and coating/insulation 2.42%. CLIC retains normalization by their rounded 100.05% sum. Table S11 instead lists 28.8 kg core steel, 6.2 kg copper winding, 1.7 kg aluminium rotor conductors and 20.3 kg aluminium housing/cooling. Those selected masses total 57 kg, leaving 5.9 kg unlisted; they differ from the figure-derived amounts. This discrepancy remains unresolved.
Source Table 3 reports 26.2 kg steel-sheet scrap and 1.23 kg aluminium/copper scrap for IM2. Conditional on the Table S11 core mass, 28.8 + 26.2 = 55 kg gross sheet gives about 47.6% steel-only loss. The printed 30% and SI discussion of nearly 50% have different apparent bases; neither is an established corrected percentage. Table S22 transports 28.1 kg scrap, 0.67 kg more than the two Table 3 rows. Housing casting uses 1.06 kg aluminium, 2.1 kWh melting and 2.6 kWh other electricity per kg casting; rotor casting has the same charge and melting energy with a separate facility boundary. Current generic shaping does not reproduce these complete processes. Any revision requires a coordinated material, retention, scrap, utility and freight model.
Huggenberger's Re460 example describes replacement of GTO converters by IGBT converters while retaining existing asynchronous motors and testing insulation compatibility. It supports a rail-technology example rather than a rail-motor bill of materials or proof of rail-duty suitability. The passenger-car study's driven-kilometre functional unit, cooling, drive-cycle losses and lifetime results are separate from these per-kg manufacturing helpers. Source publication dates and the refit article's order/service-extension dates do not establish an inventory measurement period.
Installed shares, generic metalworking and 1 kWh/kg final-assembly electricity remain the selected simplified manufacturing reference. Epoxy represents combined coating/insulation without verifying the source formulation. Metalworking services do not add a second retained material mass. The separate electrical-steel helper is a nominal ferrosilicon/low-alloy-steel blend; it does not establish a rated magnetic grade.
System boundary
One kg installed motor-material reference with generic shaping and proxy assembly electricity. Complete source gross-material purchases, punching/casting rejects, recycling, factory services and freight are not reproduced. Use-phase losses, cooling performance, eventual retirement, vehicle structure and rail infrastructure remain separate.
Included life cycle stages
Manufacturing
Technology description
The source IM2 is a 62.9 kg, 100 kW peak-power passenger-car motor with copper stator windings and aluminium rotor conductors. The selected composition covers aluminium, electrical steel, copper, low-alloy steel and combined coating/insulation. CLIC uses epoxy for the last group and adds generic material-working services plus an engineering allowance of 1 kWh/kg final assembly.
Intended application
A transparent per-kg manufacturing proxy for rail scenarios that separately specify installed motor mass, electrical design, operating duty and service life.
Use limitations
The passenger-car-to-rail transfer does not verify bearings, rated load, efficiency, insulation, thermal design or rail service life. Figure S7 and the partial design table give differing masses; substituting isolated values would mix bases. Source scrap/utility requirements and processing already represented by background suppliers need coordinated review. The 1 kWh/kg allowance is assembly input, not operating electricity or a plant power rating. Earlier scoped source searches did not establish an authoritative standalone correction; complete amendment histories remain open. External supplier terms remain separate.
Data origins
Literature, Engineering estimate, Proxy
Other fields not yet completed (5)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type
Publications (2)
Citation
Meng-Ju Hsieh; Anders Nordelöf; Emma Grunditz; Torbjörn Thiringer (2026). Life cycle assessment of electric traction induction machines. https://doi.org/10.1007/s11367-026-02610-7
Title
Life cycle assessment of electric traction induction machines
Doi
10.1007/s11367-026-02610-7
Url
https://doi.org/10.1007/s11367-026-02610-7
Source type
Scientific journal
Publication year
2026
Relation
Supporting source
Authors
Meng-Ju Hsieh · 0000-0001-5344-7963; Anders Nordelöf · 0000-0002-7455-7341; Emma Grunditz; Torbjörn Thiringer
Citation
Thomas Huggenberger (2017). IGBT converters extend life of Re460 locomotives. ABB Review1/2017, pp65–69. https://library.e.abb.com/public/bfe91c518ff94330a3c591b4bbeb8b6a/65-69%201m6073_EN_72dpi.pdf
Title
IGBT converters extend life of Re460 locomotives. ABB Review1/2017, pp65–69
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Publisher-deposited registry /message/title, /message/published and /message/author
Qualification
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
description
Qualification
Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Target field
included_life_cycle_stages
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
name
Qualification
At least manufacture/assembly is directly declared; other stages unspecified.
Target field
included_life_cycle_stages
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
description
Qualification
At least manufacture/assembly is directly declared; other stages unspecified.
Target field
publications
Origin
Editor verification
Source reference
https://doi.org/10.1007/s11367-026-02610-7
Source location
provenance
Qualification
Hsieh, Nordelöf, Grunditz and Thiringer (2026) compare a permanent-magnet reference with three passenger-car induction machines. IM2 has Cu stator windings and Al rotor conductors, 100 kW peak power and 62.9 kg total mass. Figure S7 supplies the selected material proportions. The per-kg transfer to rail is an engineering choice. Huggenberger's 2017 ABB article concerns Re460 GTO-to-IGBT converter modernization with existing asynchronous motors retained and tested for insulation compatibility. It supports a rail technology example, not a measured rail-motor bill of materials or proof that the passenger-car design has rail duty capability.
Target field
methodology_notes
Origin
Editor verification
Source reference
https://doi.org/10.1007/s11367-026-02610-7
Source location
composition
Qualification
Original SI Figure S7 gives Al 37.4%, electrical steel 46.3%, Cu 10%, low-alloy medium-carbon steel 3.93%, and coating/insulation 2.42%. Rounded shares sum 100.05%; the current reference divides by that sum. Table S11 instead lists 28.8 kg core steel, 6.2 kg Cu winding, 1.7 kg Al rotor conductors and 20.3 kg Al housing/cooling within 62.9 kg. Those listed masses sum 57 kg, leaving 5.9 kg unlisted. Figure-derived quantities differ even for the shared material groups. Preserve the explicit whole-figure basis and record the discrepancy; an isolated replacement from the partial design table would mix incompatible bases. Epoxy is a proxy for combined coating and insulation, not a verified source formulation.
Target field
methodology_notes
Origin
Editor verification
Source reference
https://doi.org/10.1007/s11367-026-02610-7
Source location
manufacture
Qualification
The current reference contains installed material shares, generic shaping and a selected 1 kWh/kg final assembly allowance. Source Table 3 reports 26.2 kg steel-sheet scrap and 1.23 kg Al/Cu scrap for IM2. Conditional on the Table S11 core mass, gross sheet is 28.8 + 26.2 = 55 kg, giving about 47.6% steel-only loss. Printed 30% and the SI's nearly-50% discussion have different apparent bases; the factory-total interpretation is an inference, not a corrected source percentage. SI Table S22 transports 28.1 kg scrap, differing from the two main-table rows by 0.67 kg. Source Al housing uses 1.06 kg Al, 2.1 kWh melting and 2.6 kWh other electricity per kg casting; rotor Al uses the same charge and melting energy with a separate facility boundary. Current generic working does not reproduce these complete processes. Composition, gross retention, scrap/recycling, utilities and freight need a coordinated model decision; no isolated scalar change is proposed.
Target field
methodology_notes
Origin
Editor verification
Source reference
https://doi.org/10.1007/s11367-026-02610-7
Source location
steel
Qualification
One nominal kg non-oriented electrical-steel proxy blends 0.032/0.75 kg assumed 75%-Si ferrosilicon with the remaining low-alloy steel and adds a separate rolling service. This adds 3.2% Si from ferrosilicon only; pre-existing Si in the steel would increase total Si. Neither supplier assay nor source electrical grade is verified. Generic alloy blending and rolling do not establish the grain orientation, annealing, coating, lamination losses, core loss or magnetic performance of rated non-oriented electrical steel. Nominal material closure is separate from grade and manufacturing validation. Treat this as a qualified alloy supply proxy, not measured production of the paper's steel grade.
Target field
methodology_notes
Origin
Editor verification
Source reference
https://doi.org/10.1007/s11367-026-02610-7
Source location
application
Qualification
The paper's functional unit is one driven kilometre in a passenger-car powertrain, with drive-cycle losses, cooling and lifetime assumptions. These per-kg material helpers do not reproduce those whole-life results, EoL, actual rail motor efficiency, bearings, rated load or thermal design. The 1 kWh/kg allowance is assembly electricity, not use-phase energy. Rolling/metal-working services are not additional material mass. Source casting and punching losses must be reviewed alongside any background-provider processing already represented. Parent rail installed motor masses, vehicle lifetimes, service allocations, track/chassis scope and current road-motor supplies remain separate; no consumer rewiring or permanent-magnet substitution is proposed by this source pass.
The four Hsieh authors have Chalmers affiliations, with Nordelöf also at Swedish VTI; verified ROR identities are 040wg7k59 and 04zmmpw58. Huggenberger's printed affiliation is ABB Discrete Automation and Motion, Power Conversion, Turgi, Switzerland. ROR 00ks5vt51 identifies the Swiss ABB corporate parent for affiliation normalization, not an exact legal subsidiary or supplier contract. Preserve the historical unit label and distinguish Swiss ABB from Finnish/German ABB records and unrelated US ABB abbreviations. SBB is the operator/client in the refit article, not an inferred research funder or CLIC contributor. Chalmers open-access publication support is not an inferred research award or funding of these engineering adapters. Contributor, project and funding arrays remain unchanged.
Target field
publications
Origin
Editor verification
Source reference
https://doi.org/10.1007/s11367-026-02610-7
Source location
updates
Qualification
Scoped publisher, current Crossref and manufacturer searches did not establish an authoritative standalone correction; complete change histories remain open. The source figure/design-table and scrap-basis differences are recorded discrepancies without inventing an erratum. Hsieh publication year is 2026, with publisher online date 9 March; modeled scenarios and use phase do not date the current inventory. ABB Review issue 1/2017 is the source date; the article's 2014 order, planned service extension and current hosting are distinct. Direct publisher Tables 2/3 were recovered after browser probes failed. Existing source and exact-version guards preserve all original metadata and inventories; no live catalogue edits or material revision is applied.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Design capacity: Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Design capacity unit: Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Capacity factor (%): Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Annual production volume: Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Annual production volume unit: Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Annual production volume year: Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Plant or represented-asset lifetime (years): Unspecified. Basis: Own kg alloy or motor manufacture does not identify a configured plant. Source IM2 peak power100 kW is product performance; installed62.9 kg mass, scrap percentages and specific assembly electricity do not establish own output capacity, capacity factor, annual production or plant calendar lifetime. Vehicle lifetime and converter-refit service-extension examples retain separate scopes. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Commercial maturity stage: mature_commercial. Basis: Use mature-commercial/9 only as explicit curator assessments of established underlying charger/converter/display/PLC/motor/material manufacturing classes, supported by manufacturer or conventional source context. This is not a source-assigned exact TRL, validation of transferred BOM, or approval of this fitted vehicle/station architecture. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Technology readiness level: 9. Basis: Use mature-commercial/9 only as explicit curator assessments of established underlying charger/converter/display/PLC/motor/material manufacturing classes, supported by manufacturer or conventional source context. This is not a source-assigned exact TRL, validation of transferred BOM, or approval of this fitted vehicle/station architecture. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Technological representativeness: 4. Basis: Curator technology/geography/time 4/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Geographical representativeness: 3. Basis: Curator technology/geography/time 4/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Target field
technology_description
Origin
Editor verification
Source reference
https://zenodo.org/records/23935622
Source location
Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded
Qualification
Technical-characterisation review TC-3758. Temporal representativeness: 4. Basis: Curator technology/geography/time 4/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Technology characterizationScale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Mature commercial
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scaleHigher is more mature.9: routine commercial deployment8: commercial, but still niche or scaling7: first-commercial or advanced demonstration6: engineering-scale demonstration5: pilot or large prototype4: bench or lab validated3: research-stage conceptTechnology readiness level
123456789
earlymature
1 to 5 scaleLower is better.1: strong market- or operating-data basis2: commercially plausible, but still somewhat specific3: partly representative, with modelling or adaptation bias4: pilot, proxy-based, scaled-up, or prospective5: weak representation of the real technology stateTechnological representativeness
12345
strongweak
1 to 5 scaleLower is better.1: geography matches the claimed scope well2: regionally credible, but broader or less exact3: generic regional or global proxy4: weak proxy or clear geographic mismatch5: geography is effectively unsupportedGeographical representativeness
12345
strongweak
1 to 5 scaleLower is better.1: current for that technology class2: slightly dated, but still good3: dated enough to need caution4: stale, pilot-era, or prospective relative to current practice5: clearly not representative of the current stateTemporal representativeness
12345
strongweak
Missing exchange uncertainty generation:
Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Results per kilogram, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Acidification0.113338
mol H+-Eq / kilogram
Climate change5.96939
kg CO2-Eq / kilogram
Freshwater ecotoxicity30.6521
CTUe / kilogram
Freshwater eutrophication0.00486823
kg P-Eq / kilogram
Marine eutrophication0.00600742
kg N-Eq / kilogram
Photochemical ozone formation0.0241823
kg NMVOC-Eq / kilogram
Resource use, fossils87.0036
MJ, net calorific value / kilogram
Resource use, minerals and metals5.1565e-05
kg Sb-Eq / kilogram
Water use65.7278
m3 world Eq deprived / kilogram
Screening result
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Show all 16 indicator totals
Acidification0.113338
mol H+-Eq / kilogram
Climate change5.96939
kg CO2-Eq / kilogram
Freshwater ecotoxicity30.6521
CTUe / kilogram
Freshwater eutrophication0.00486823
kg P-Eq / kilogram
Marine eutrophication0.00600742
kg N-Eq / kilogram
Terrestrial eutrophication0.0558074
mol N-Eq / kilogram
Human toxicity, cancer9.3283e-09
CTUh / kilogram
Human toxicity, non-cancer1.6729e-07
CTUh / kilogram
Ionising radiation3.02206
kBq U235-Eq / kilogram
Land use24.7128
dimensionless / kilogram
Ozone depletion1.2549e-07
kg CFC-11-Eq / kilogram
Particulate matter3.9355e-07
disease incidence / kilogram
Photochemical ozone formation0.0241823
kg NMVOC-Eq / kilogram
Resource use, fossils87.0036
MJ, net calorific value / kilogram
Resource use, minerals and metals5.1565e-05
kg Sb-Eq / kilogram
Water use65.7278
m3 world Eq deprived / kilogram
Calculation details
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-09 12:49 UTC. These screening results do not replace a reviewed comparative LCA.
Dataset contents
Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.
Outputs
Reference flow1 rowReference production exchanges extracted from the uploaded inventory.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
electric motor production, asynchronous, traction
GLO
electric motor, asynchronous, traction
1
kilogram
-
Reference flow
Inputs
Technosphere inputs9 rowsLinked foreground or background product inputs used by this dataset.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
market for aluminium, wrought alloy
GLO
aluminium, wrought alloy
0.37
kilogram
-
0.0090249mol H+-Eq / kilogram
8.0% of total
1.8594kg CO2-Eq / kilogram
31.1% of total
5.48557CTUe / kilogram
17.9% of total
0.000490826kg P-Eq / kilogram
10.1% of total
0.00164896kg N-Eq / kilogram
27.4% of total
0.0133963mol N-Eq / kilogram
24.0% of total
2.1037e-09CTUh / kilogram
22.6% of total
3.4632e-08CTUh / kilogram
20.7% of total
1.01356kBq U235-Eq / kilogram
33.5% of total
3.48781dimensionless / kilogram
14.1% of total
3.2232e-08kg CFC-11-Eq / kilogram
25.7% of total
1.0144e-07disease incidence / kilogram
25.8% of total
0.00492989kg NMVOC-Eq / kilogram
20.4% of total
28.6115MJ, net calorific value / kilogram
32.9% of total
1.5959e-06kg Sb-Eq / kilogram
3.1% of total
12.774m3 world Eq deprived / kilogram
19.4% of total
1.0751e-07disease incidence / kilogram
27.3% of total
0.0095233kg NMVOC-Eq / kilogram
39.4% of total
11.1681MJ, net calorific value / kilogram
12.8% of total
8.6969e-06kg Sb-Eq / kilogram
16.9% of total
0.759823m3 world Eq deprived / kilogram
1.2% of total
BAFU:2025
market for steel, low-alloyed
GLO
steel, low-alloyed
0.04
kilogram
-
0.000245222mol H+-Eq / kilogram
0.2% of total
0.0839484kg CO2-Eq / kilogram
1.4% of total
0.198049CTUe / kilogram
0.6% of total
3.2735e-05kg P-Eq / kilogram
0.7% of total
5.6694e-05kg N-Eq / kilogram
0.9% of total
0.000604979mol N-Eq / kilogram
1.1% of total
2.9239e-10CTUh / kilogram
3.1% of total
2.0037e-09CTUh / kilogram
1.2% of total
0.0150316kBq U235-Eq / kilogram
0.5% of total
0.200718dimensionless / kilogram
0.8% of total
8.1024e-10kg CFC-11-Eq / kilogram
0.6% of total
5.7186e-09disease incidence / kilogram
1.5% of total
0.000258365kg NMVOC-Eq / kilogram
1.1% of total
0.736841MJ, net calorific value / kilogram
0.8% of total
7.4140e-07kg Sb-Eq / kilogram
1.4% of total
0.0137289m3 world Eq deprived / kilogram
0.0% of total
BAFU:2025
market for epoxy resin, liquid
RER
epoxy resin, liquid
0.02
kilogram
-
0.0012301mol H+-Eq / kilogram
1.1% of total
0.166355kg CO2-Eq / kilogram
2.8% of total
7.29021CTUe / kilogram
23.8% of total
5.0770e-06kg P-Eq / kilogram
0.1% of total
0.000332044kg N-Eq / kilogram
5.5% of total
0.00361189mol N-Eq / kilogram
6.5% of total
4.8081e-11CTUh / kilogram
0.5% of total
3.2701e-09CTUh / kilogram
2.0% of total
8.4051e-05kBq U235-Eq / kilogram
0.0% of total
0.00565714dimensionless / kilogram
0.0% of total
5.5615e-12kg CFC-11-Eq / kilogram
0.0% of total
3.5237e-08disease incidence / kilogram
9.0% of total
0.00103097kg NMVOC-Eq / kilogram
4.3% of total
3.05856MJ, net calorific value / kilogram
3.5% of total
7.5174e-07kg Sb-Eq / kilogram
1.5% of total
0.000160956m3 world Eq deprived / kilogram
0.0% of total
BAFU:2025
metal working, average for aluminium product manufacturing
RER
metal working, average for aluminium product manufacturing
0.37
kilogram
-
0.00283541mol H+-Eq / kilogram
2.5% of total
0.804359kg CO2-Eq / kilogram
13.5% of total
2.84913CTUe / kilogram
9.3% of total
0.000261023kg P-Eq / kilogram
5.4% of total
0.00063345kg N-Eq / kilogram
10.5% of total
0.00492282mol N-Eq / kilogram
8.8% of total
6.5100e-10CTUh / kilogram
7.0% of total
1.0346e-08CTUh / kilogram
6.2% of total
0.413059kBq U235-Eq / kilogram
13.7% of total
3.89547dimensionless / kilogram
15.8% of total
2.2184e-08kg CFC-11-Eq / kilogram
17.7% of total
2.7982e-08disease incidence / kilogram
7.1% of total
0.00185959kg NMVOC-Eq / kilogram
7.7% of total
12.5557MJ, net calorific value / kilogram
14.4% of total
1.1542e-06kg Sb-Eq / kilogram
2.2% of total
21.065m3 world Eq deprived / kilogram
32.0% of total
BAFU:2025
metal working, average for copper product manufacturing
RER
metal working, average for copper product manufacturing
0.1
kilogram
-
0.00377273mol H+-Eq / kilogram
3.3% of total
0.14281kg CO2-Eq / kilogram
2.4% of total
1.4753CTUe / kilogram
4.8% of total
0.00122829kg P-Eq / kilogram
25.2% of total
0.000313463kg N-Eq / kilogram
5.2% of total
0.0033844mol N-Eq / kilogram
6.1% of total
5.3419e-10CTUh / kilogram
5.7% of total
4.5225e-08CTUh / kilogram
27.0% of total
0.0625577kBq U235-Eq / kilogram
2.1% of total
1.39641dimensionless / kilogram
5.7% of total
4.8564e-09kg CFC-11-Eq / kilogram
3.9% of total
9.6464e-09disease incidence / kilogram
2.5% of total
0.000958049kg NMVOC-Eq / kilogram
4.0% of total
2.18295MJ, net calorific value / kilogram
2.5% of total
2.6146e-05kg Sb-Eq / kilogram
50.7% of total
4.91403m3 world Eq deprived / kilogram
7.5% of total
BAFU:2025
metal working, average for steel product manufacturing
RER
metal working, average for steel product manufacturing
0.5
kilogram
-
0.00188624mol H+-Eq / kilogram
1.7% of total
0.777405kg CO2-Eq / kilogram
13.0% of total
2.78709CTUe / kilogram
9.1% of total
0.00030154kg P-Eq / kilogram
6.2% of total
0.000532929kg N-Eq / kilogram
8.9% of total
0.00445677mol N-Eq / kilogram
8.0% of total
1.1086e-09CTUh / kilogram
11.9% of total
9.5822e-09CTUh / kilogram
5.7% of total
0.302781kBq U235-Eq / kilogram
10.0% of total
4.77083dimensionless / kilogram
19.3% of total
2.2668e-08kg CFC-11-Eq / kilogram
18.1% of total
2.4501e-08disease incidence / kilogram
6.2% of total
0.0018064kg NMVOC-Eq / kilogram
7.5% of total
10.6209MJ, net calorific value / kilogram
12.2% of total
3.2191e-06kg Sb-Eq / kilogram
6.2% of total
24.583m3 world Eq deprived / kilogram
37.4% of total
BAFU:2025
market group for electricity, medium voltage
Europe without Switzerland
electricity, medium voltage
1
kilowatt hour
-
0.000176832mol H+-Eq / kilogram
0.2% of total
0.0895816kg CO2-Eq / kilogram
1.5% of total
0.271848CTUe / kilogram
0.9% of total
7.0482e-05kg P-Eq / kilogram
1.4% of total
7.2004e-05kg N-Eq / kilogram
1.2% of total
0.000522949mol N-Eq / kilogram
0.9% of total
6.4683e-11CTUh / kilogram
0.7% of total
6.9362e-10CTUh / kilogram
0.4% of total
0.679627kBq U235-Eq / kilogram
22.5% of total
1.10644dimensionless / kilogram
4.5% of total
1.0518e-08kg CFC-11-Eq / kilogram
8.4% of total
4.1496e-09disease incidence / kilogram
1.1% of total
0.000168756kg NMVOC-Eq / kilogram
0.7% of total
6.72843MJ, net calorific value / kilogram
7.7% of total
2.6907e-07kg Sb-Eq / kilogram
0.5% of total
0.577453m3 world Eq deprived / kilogram
0.9% of total
BAFU:2025
Parameters0 source definitions · values, formulas and uncertainty.
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Downloads & files
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Add to download basket
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Adds electric motor production, asynchronous, traction, supplying 1 kilogram of electric motor, asynchronous, traction in GLO. This is a new catalogue entry with no…
Published · Viewing · Latest
Show full version history table (1 version)
Version
Published
Reason for this version
Link
Version 1.0.0
2026-11-03
Adds electric motor production, asynchronous, traction, supplying 1 kilogram of electric motor, asynchronous, traction in GLO. This is a new catalogue entry with no earlier version for a like-for-like revision comparison.
Adds electric motor production, asynchronous, traction, supplying 1 kilogram of electric motor, asynchronous, traction in GLO. This is a new catalogue entry with no earlier version for a like-for-like revision comparison.
Declared licence: CC BY 4.0. Source documents and external supplier inventories retain their own terms.
Activity/product labels and supplier references only; coefficients, formulas, uncertainty, declared output and unit are unchanged. Original engineering assumptions, functional-unit basis and limitations remain below
Review & discussionPublication provenance, scientific review and community discussion.
Public review record
Curator-led bulk import. Public evidence is shown without participant
accounts, assignments, recommendations, or private editor notes.
Show reviewHide review
Publication route
Curator-led bulk import
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
No public review transcript is available for this version.
Discussion0 public comments · questions, context and problem reports.
Public discussion
Questions and comments are public. The dataset submitter is notified.
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.