Hydrogen distribution

high pressure hydrogen storage tank

Reference product high pressure hydrogen storage tank GLO

Published Version 1.0.1 Not assessed Latest published

Stable dataset identity high-pressure-hydrogen-storage-tank

Unit
kilogram
Reuse license
CC BY 4.0
Published
2026-11-03
Version
1.0.1
Technology maturity
See quality profile

Published inventory

Overview

Process description and catalog context. View scientific metadata

Description

Manufacture of high-pressure hydrogen storage equipment per 1 kg H2 storage capacity. The reference denotes capacity rather than vessel mass or hydrogen delivered over a lifetime.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Hydrogen distribution (energy/hydrogen/distribution)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0

Classification path: Energy > Hydrogen > Hydrogen distribution

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Scientific journal publication

Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180

Inventory changes relative to source: Not assessed

Equivalence to the original source inventory has not been established.

Background database
ecoinvent / 3.7
Background system model
cut-off
Biosphere database
ecoinvent / 3.7

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Mature commercial
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
20 years
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 10 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per kilogram, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change Unavailable failed
Screening score unavailable

A score could not be calculated because one or more inventory exchanges could not be linked to the UVEK 2025 screening background.

Missing factors are not treated as zero. The inventory remains available while the background mapping is corrected.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata
high pressure hydrogen storage tank
GLO
high pressure hydrogen storage tank
1
kilogram -

Inputs

Technosphere inputs 9 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata
market for sheet rolling, aluminium
GLO
sheet rolling, aluminium
0.6
kilogram -
market for aluminium, wrought alloy
GLO
aluminium, wrought alloy
0.6
kilogram
market for sheet rolling, chromium steel
GLO
sheet rolling, chromium steel
0.9
kilogram -
market for steel, chromium steel 18/8
GLO
steel, chromium steel 18/8
0.9
kilogram -
carbon fiber, weaved
7.14
kilogram -
market for epoxy resin, liquid
RER
epoxy resin, liquid
3.06
kilogram -
market group for electricity, low voltage
RER
electricity, low voltage
0.45
kilowatt hour -
market for sheet rolling, steel
GLO
sheet rolling, steel
0.9
kilogram -
market for steel, low-alloyed
GLO
steel, low-alloyed
0.9
kilogram -
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 2 versions · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  • Version 1.0.1 revises version 1.0.0.
  1. Version 1.0.0
    Published

    First published inventory; no earlier version is available for comparison.

    Superseded
  2. Version 1.0.1
    Published

    The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.

    Published · Viewing · Latest
Show full version history table (2 versions)
Version Published Reason for this version Link
Version 1.0.1 2026-11-03 The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation. Current view
Version 1.0.0 Superseded Published 2026-07-15 First published inventory; no earlier version is available for comparison. Open version
About this version

Why this version changed

The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.

Release notes

Pressure-vessel and station-design assumptions remain those of the source model.

Source: https://doi.org/10.1016/j.jclepro.2018.07.180.

Declared foreground licence: CC-BY-4.0. Source publications and external supplier inventories retain their own terms.

Changes from version 1.0.0 Compare this version with its predecessor. Exchanges are grouped by type and change; biosphere labels include their environmental compartments. Open the base version. Show changes Hide changes

Why this version changed

The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.

Public revision record

This comparison is permanently visible with the published version so users can assess every detected change before reuse.

Modified exchanges
0
Added exchanges
1
Removed exchanges
1
Inventory metadata
0
Version metadata
13
Technosphere exchanges added 1
Technosphere exchanges added
Exchange / scope Field Previous value Revised value Reason
market for aluminium, wrought alloy (technosphere / GLO / kilogram) Amount Not present 0.6 kilogram The aluminium, wrought alloy entry supplies the material, process or treatment required by the revised reference. The selected source correction applies to the actual component boundary, without changing the station service or claiming a new storage performance. The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.
Technosphere exchanges removed 1
Technosphere exchanges removed
Exchange / scope Field Previous value Revised value Reason
market for aluminium alloy, AlLi (technosphere / GLO / kilogram) Amount 0.6 kilogram Not present The former aluminium alloy, AlLi entry is superseded by the revised product/component boundary. The selected source correction applies to the actual component boundary, without changing the station service or claiming a new storage performance. The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.
Metadata changes 13
Metadata changes
Exchange / scope Field Previous value Revised value Reason
Version metadata Commercial maturity stage early_commercial mature_commercial No explanation was recorded for this change.
Version metadata Description Manufacture of high-pressure storage equipment per1kg hydrogen storage capacity. PublisherS6 is per10kg capacity and lists126kg dry materials plus24kg forming services and4.5kWh electricity. Current normalized dry mass is12.6kg/kgcapacity; metal-forming services are additional processing, not additional embodied mass. Archived assumed life20years; current fibre supplier differs from the source's upstream Das recipe. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence.

Wulf et al.(2018), Journal of Cleaner Production199,431–443, compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. The archived component references here cover only their stated manufacturing or auxiliary service, not an entire delivered-hydrogen pathway. Original SI and later premise adapter remain distinct. Publication2018 is not automatically inventory reference year; no software/LCIA method or background profile is inferred from another paper.
Manufacture of high-pressure hydrogen storage equipment per 1 kg H2 storage capacity. The reference denotes capacity rather than vessel mass or hydrogen delivered over a lifetime.
Version metadata Methodology and allocation explanation Wulf et al.(2018), Journal of Cleaner Production199,431–443, compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. The archived component references here cover only their stated manufacturing or auxiliary service, not an entire delivered-hydrogen pathway. Original SI and later premise adapter remain distinct. Publication2018 is not automatically inventory reference year; no software/LCIA method or background profile is inferred from another paper. Source model
Wulf et al. (2018) compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. These components represent only the stated manufacture or auxiliary service. The original supplement and later premise adapter retain distinct roles; 2018 is not an inferred inventory reference year.

Component basis
Table S6's 126 kg dry materials, 24 kg forming services and 4.5 kWh per 10 kg capacity become 12.6 kg dry materials, 2.4 kg forming and 0.45 kWh/kg capacity. Forming is additional processing, not additional embodied mass. The selected tank life is 20 years.
Version metadata Publication / citation Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production,199,431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180
Version metadata Source Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production,199,431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180
Version metadata Contributors, publications, projects and supporting evidence Funding: 1. Project: Not set
Funding: 1. Organization: Ror: https://ror.org/0281dp749
Funding: 1. Organization: Url: https://www.helmholtz.de/
Funding: 1. Organization: Name: Helmholtz Association of German Research Centres
Funding: 1. Award identifier: Not set
Evidence: 1. Origin: source_import
Evidence: 1. Target field: publications
Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: editor_verification
Evidence: 2. Target field: publications
Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 2. Source reference: https://api.crossref.org/works/10.1016%2Fj.jclepro.2018.07.180
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: data_origins
Evidence: 4. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 4. Source location: description
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: technology_description
Evidence: 5. Qualification: Only this supplied activity is described; whole-paper life-cycle boundaries not copied onto components.
Evidence: 5. Source location: description
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Seven authors in publisher order; all Jülich parent affiliation. HistoricalIEK-STE/IEK-3 units are retained as source context, not contemporary department substitutions or automatic RWTH affiliations.
Evidence: 6. Source location: Publisher byline;Crossref;JuSER850627
Evidence: 6. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: methodology_notes
Evidence: 7. Qualification: Manufacture of high-pressure storage equipment per1kg hydrogen storage capacity. PublisherS6 is per10kg capacity and lists126kg dry materials plus24kg forming services and4.5kWh electricity. Current normalized dry mass is12.6kg/kgcapacity; metal-forming services are additional processing, not additional embodied mass. Archived assumed life20years; current fibre supplier differs from the source's upstream Das recipe. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. Quantity agreement is partial and does not certify supplier chemistry, source anomalies, coproduct allocation, loss ownership or uncertainty.
Evidence: 7. Source location: S3–S8; exact quantities and source denominators
Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S095965261832170X-mmc1.docx
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: funding
Evidence: 8. Qualification: Helmholtz source-publication support has no awardnumber and projectlink remains null. ES2050 is a source-studyprogramme, not proof of funding of CLIC compilation or a specific award. Jülich member institution is distinct from umbrella Helmholtz funder.
Evidence: 8. Source location: Crossmark funding;institutional research-program listing
Evidence: 8. Source reference: https://crossmark.crossref.org/dialog/?doi=10.1016%2Fj.jclepro.2018.07.180
Projects: 1. Url: https://www.helmholtz.de/en/research/research-fields/energy/energy-system-2050/
Projects: 1. Name: Energy System 2050 – A Contribution of the Research Field Energy
Projects: 1. Acronym: ES2050
Projects: 1. Relation: source_study
Projects: 1. Grant identifier: Not set
Publications: 1. Doi: 10.1016/j.jclepro.2018.07.180
Publications: 1. Url: https://doi.org/10.1016/j.jclepro.2018.07.180
Publications: 1. Title: Life Cycle Assessment of hydrogen transport and distribution options
Publications: 1. Scientific authors: 1. Name: Christina Wulf
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 2. Name: Markus Reuß
Publications: 1. Scientific authors: 2. Orcid: Not set
Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 3. Name: Thomas Grube
Publications: 1. Scientific authors: 3. Orcid: Not set
Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 4. Name: Petra Zapp
Publications: 1. Scientific authors: 4. Orcid: Not set
Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 5. Name: Martin Robinius
Publications: 1. Scientific authors: 5. Orcid: 0000-0002-5307-3022
Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 6. Name: Jürgen-Friedrich Hake
Publications: 1. Scientific authors: 6. Orcid: Not set
Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 6. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 6. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 7. Name: Detlef Stolten
Publications: 1. Scientific authors: 7. Orcid: Not set
Publications: 1. Scientific authors: 7. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 7. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 7. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Citation: Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production,199,431–443. https://doi.org/10.1016/j.jclepro.2018.07.180
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2018
Funding: 1. Project: Not set
Funding: 1. Organization: Ror: https://ror.org/0281dp749
Funding: 1. Organization: Url: https://www.helmholtz.de/
Funding: 1. Organization: Name: Helmholtz Association of German Research Centres
Funding: 1. Award identifier: Not set
Evidence: 1. Origin: source_import
Evidence: 1. Target field: publications
Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: editor_verification
Evidence: 2. Target field: publications
Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 2. Source reference: https://api.crossref.org/works/10.1016%2Fj.jclepro.2018.07.180
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: data_origins
Evidence: 4. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 4. Source location: description
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: technology_description
Evidence: 5. Qualification: Only this supplied activity is described; whole-paper life-cycle boundaries not copied onto components.
Evidence: 5. Source location: description
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Seven authors in publisher order; all Jülich parent affiliation. HistoricalIEK-STE/IEK-3 units are retained as source context, not contemporary department substitutions or automatic RWTH affiliations.
Evidence: 6. Source location: Publisher byline;Crossref;JuSER850627
Evidence: 6. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: methodology_notes
Evidence: 7. Qualification: Manufacture of high-pressure storage equipment per1kg hydrogen storage capacity. PublisherS6 is per10kg capacity and lists126kg dry materials plus24kg forming services and4.5kWh electricity. Current normalized dry mass is12.6kg/kgcapacity; metal-forming services are additional processing, not additional embodied mass. Archived assumed life20years; current fibre supplier differs from the source's upstream Das recipe. Quantity agreement is partial and does not certify supplier chemistry, source anomalies, coproduct allocation, loss ownership or uncertainty.
Evidence: 7. Source location: S3–S8; exact quantities and source denominators
Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S095965261832170X-mmc1.docx
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: funding
Evidence: 8. Qualification: Helmholtz source-publication support has no awardnumber and projectlink remains null. ES2050 is a source-studyprogramme, not proof of funding of CLIC compilation or a specific award. Jülich member institution is distinct from umbrella Helmholtz funder.
Evidence: 8. Source location: Crossmark funding;institutional research-program listing
Evidence: 8. Source reference: https://crossmark.crossref.org/dialog/?doi=10.1016%2Fj.jclepro.2018.07.180
Evidence: 9. Origin: editor_verification
Evidence: 9. Target field: methodology_notes
Evidence: 9. Qualification: Manifest-verified historical decision NB-BOUNDED-2032. Preserve the identified prior repair and its source/profile qualifications. Exact agreement is not blanket approval of every other amount, provider, uncertainty or future version. Original decision rationale: Compose only the source-verified corrections recorded in audit ordinals 140; preserve the remaining curated model, original paired profiles and published history. Original qualification: The individual cited source/proxy and engineering limitations remain binding. No complete-model replacement, performance change, new recovery credit or blanket background migration is authorized. Specific prior repair evidence: Wulf2018 station TableS4 specifies499kg aluminium and tank TableS6 specifies6kgAl per10kgcapacity; it does not specify an aluminium-lithium aerospace alloy. Replacing that unusual alloy supplier by existing generic wrought aluminium at unchanged499kg station and0.6kg perkg H2capacity is a reasonable scoped correction. Generic wrought is still an alloy/grade proxy, not proof of pureAl or permission to set all alloying elements to zero or change background primary-secondary shares. Subsequent one-unit tank provider incorporates75kg at125kgcapacity, independently verified; no blanket correction of other alloy consumers is authorized.
Evidence: 9. Source location: Historical preservation register P013/P014 or scoped H-series review; original encoding and approval boundaries retained
Evidence: 9. Source reference: Manifest-verified prior correction/source/migration decisions and exact archive guards
Evidence: 10. Origin: editor_verification
Evidence: 10. Target field: technology_description
Evidence: 10. Qualification: Technical-characterisation review TC-2032. Design capacity: Unspecified. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 10. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 10. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 11. Origin: editor_verification
Evidence: 11. Target field: technology_description
Evidence: 11. Qualification: Technical-characterisation review TC-2032. Design capacity unit: Unspecified. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 11. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 11. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 12. Origin: editor_verification
Evidence: 12. Target field: technology_description
Evidence: 12. Qualification: Technical-characterisation review TC-2032. Capacity factor (%): Unspecified. Basis: Source renewal fractions, storage share, pump efficiency and chemical/carrier normalization are not a matched own nameplate/output capacity factor. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 12. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 12. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 13. Origin: editor_verification
Evidence: 13. Target field: technology_description
Evidence: 13. Qualification: Technical-characterisation review TC-2032. Annual production volume: Unspecified. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 13. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 13. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 14. Origin: editor_verification
Evidence: 14. Target field: technology_description
Evidence: 14. Qualification: Technical-characterisation review TC-2032. Annual production volume unit: Unspecified. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 14. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 14. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 15. Origin: editor_verification
Evidence: 15. Target field: technology_description
Evidence: 15. Qualification: Technical-characterisation review TC-2032. Annual production volume year: Unspecified. Basis: No annual observation year is established by publication 2018, source-cited study dates or model construction/service calendars. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 15. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 15. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 16. Origin: editor_verification
Evidence: 16. Target field: technology_description
Evidence: 16. Qualification: Technical-characterisation review TC-2032. Plant or represented-asset lifetime (years): 20. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 16. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions
Evidence: 16. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 17. Origin: editor_verification
Evidence: 17. Target field: technology_description
Evidence: 17. Qualification: Technical-characterisation review TC-2032. Commercial maturity stage: mature_commercial. Basis: Curator assessment of established pressure-vessel manufacture, zinc coating or solution-mining method classes. This is not source-assigned TRLor certification of the exact retained recipe, hydraulic equipment, pressure qualification or hydrogen operating site. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 17. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json
Evidence: 17. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 18. Origin: editor_verification
Evidence: 18. Target field: technology_description
Evidence: 18. Qualification: Technical-characterisation review TC-2032. Technology readiness level: 9. Basis: Curator assessment of established pressure-vessel manufacture, zinc coating or solution-mining method classes. This is not source-assigned TRLor certification of the exact retained recipe, hydraulic equipment, pressure qualification or hydrogen operating site. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 18. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json
Evidence: 18. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 19. Origin: editor_verification
Evidence: 19. Target field: technology_description
Evidence: 19. Qualification: Technical-characterisation review TC-2032. Technological representativeness: 4. Basis: Curator proxy score4for transferred equipment/materials and selected process, chemical or allocation assumptions, not an independently measured representative industrial inventory. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 19. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json
Evidence: 19. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 20. Origin: editor_verification
Evidence: 20. Target field: technology_description
Evidence: 20. Qualification: Technical-characterisation review TC-2032. Geographical representativeness: 3. Basis: Curator score at least3for generic suppliers/equipment and regional transfers; retain broaderproxy4where already present. No production-weighted exact plant or regional sample established. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 20. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json
Evidence: 20. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Evidence: 21. Origin: editor_verification
Evidence: 21. Target field: technology_description
Evidence: 21. Qualification: Technical-characterisation review TC-2032. Temporal representativeness: 4. Basis: Curator historical/mixed score4for2018andolder source inputs plus archived engineering assumptions. Publication and compilation dates do not establish a common observed inventory year. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 21. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json
Evidence: 21. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180
Projects: 1. Url: https://www.helmholtz.de/en/research/research-fields/energy/energy-system-2050/
Projects: 1. Name: Energy System 2050 – A Contribution of the Research Field Energy
Projects: 1. Acronym: ES2050
Projects: 1. Relation: source_study
Projects: 1. Grant identifier: Not set
Publications: 1. Doi: 10.1016/j.jclepro.2018.07.180
Publications: 1. Url: https://doi.org/10.1016/j.jclepro.2018.07.180
Publications: 1. Title: Life Cycle Assessment of hydrogen transport and distribution options
Publications: 1. Scientific authors: 1. Name: Christina Wulf
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 2. Name: Markus Reuß
Publications: 1. Scientific authors: 2. Orcid: Not set
Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 3. Name: Thomas Grube
Publications: 1. Scientific authors: 3. Orcid: Not set
Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 4. Name: Petra Zapp
Publications: 1. Scientific authors: 4. Orcid: Not set
Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 5. Name: Martin Robinius
Publications: 1. Scientific authors: 5. Orcid: 0000-0002-5307-3022
Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 6. Name: Jürgen-Friedrich Hake
Publications: 1. Scientific authors: 6. Orcid: Not set
Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 6. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 6. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Scientific authors: 7. Name: Detlef Stolten
Publications: 1. Scientific authors: 7. Orcid: Not set
Publications: 1. Scientific authors: 7. Affiliations: 1. Ror: https://ror.org/02nv7yv05
Publications: 1. Scientific authors: 7. Affiliations: 1. Url: https://www.fz-juelich.de/
Publications: 1. Scientific authors: 7. Affiliations: 1. Name: Forschungszentrum Jülich
Publications: 1. Citation: Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2018
Version metadata System boundary Manufacture of high-pressure storage equipment per1kg hydrogen storage capacity. PublisherS6 is per10kg capacity and lists126kg dry materials plus24kg forming services and4.5kWh electricity. Current normalized dry mass is12.6kg/kgcapacity; metal-forming services are additional processing, not additional embodied mass. Archived assumed life20years; current fibre supplier differs from the source's upstream Das recipe. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. Wulf et al.(2018), Journal of Cleaner Production199,431–443, compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. The archived component references here cover only their stated manufacturing or auxiliary service, not an entire delivered-hydrogen pathway. Original SI and later premise adapter remain distinct. Publication2018 is not automatically inventory reference year; no software/LCIA method or background profile is inferred from another paper. The recorded storage-equipment materials, manufacturing/forming services and electricity per kilogram H2 capacity. Stored hydrogen, refilling throughput and operational compression are outside this manufacturing node.
Version metadata Technological representativeness 2 4
Version metadata Technology description Manufacture of high-pressure storage equipment per1kg hydrogen storage capacity. PublisherS6 is per10kg capacity and lists126kg dry materials plus24kg forming services and4.5kWh electricity. Current normalized dry mass is12.6kg/kgcapacity; metal-forming services are additional processing, not additional embodied mass. Archived assumed life20years; current fibre supplier differs from the source's upstream Das recipe. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. Composite high-pressure storage-equipment manufacture normalized from publisher Table S6 per 10 kg H2 capacity, including materials, forming and electricity.
Version metadata Technology readiness level 8 9
Version metadata Temporal representativeness 3 4
Version metadata Limitations on use Original publisher SI is recovered and hashed. Main full text remains restricted at JuSER; Elsevier API supplies bibliographic core only and institutional HTTP200 probes are HTML challenge payloads. No verified detailed LCIA method, software version, complete background system model or main-text acknowledgments inferred from other papers.
Station S4 is850 kg/day nominal; archived70 percent utilization gives595 kg/day. Station40year/tank20year lives are archived assumptions. S8 installed125 kg H2 capacity times two lifetime purchases equals current250 kg capacity units. Do not describe250 kg as vessel mass or simultaneous capacity. S6 dry materials12.6 kg/kgcapacity exclude2.4 kg forming services. Later unit125kg helper is absent from pinned CLIC snapshot and is not a missing originalpaper dataset or a proposed addition.
S6 source carbon fibre uses Das2011 recipe (2.25kg acrylonitrile,0.20kg vinyl acetate,1.07kg resin,175kWh heat and26.2kWh electricity perkg fibre). CLIC references later Benitez-derived weaved fibre; quantity agreement does not certify fibre type, process or source equivalence. No measured tank pressure or replacement frequency inferred from truck500bar reference.
S5 hydrogenation electricity666Wh versus current660Wh is a0.9 percent source/compiler difference, not within the half-percent comparison screen. One conditional current2043amount candidate records0.666kWh. Confirm source precision and intended incremental-service basis before new version; no publisher corrigendum establishes this as a corrected coefficient.
Hydrogenation source10g H2/kg is absent from its auxiliary recipe. Neither hydrogenation nor dehydrogenation purchases basehydrogen; trace caller loss/makeup ownership before adding10g, full1kg or direct H2 emissions. Dehydrogenation9.5kWh heat equals current34.2MJ, and366Wh electricity matches. Existing dehydrogenation/DBT descriptions incorrectly repeat hydrogenation and1percentloss; correct component descriptions separately.
DBT source2mg iron(III) chloride is mapped to2mg iron(III) sulfate in CLIC. Equal numerical mass does not establish chemistry equivalence; verify exact intended catalyst and available supplier without guessing a replacement UUID. Source535g HCl coproduct lacks solution concentration/allocation; pure535gHCl contains about520g chlorine, exceeding printed260gCl2, whereas535g of30percent solution would contain about156g chlorine. This conditional composition screen is not proof of a source error or permission for a coproduct credit. Source42.1kWh/kg electricity is copied exactly; high magnitude alone does not justify changing its unit.
S7 construction water31.25kg and electricity0.09375kWh perkg agree with5millionm3 water and15,000MWh divided by4000t/year*40years.570kW is pump capacity;570/0.76=750kW electrical draw. Tap water remains a compiler provider proxy, with brine/resource/outlet ownership unresolved.2350t cushion is an initial stock; lifetime equivalent0.0146875kg/kg is not automatically recurring1.3percentloss. Storage service0.344kWh covers0.240compression+0.104drying; extra0.48return compression and1percentannualH2loss need caller-boundary review, not automatic addition.
S3 pertonne coating source has heatCHP768kg, sodaash1000kg and no explicit bulkZn/Al/Si feed. Coating is an application/process recipe, not demonstrated production of1kg alloy. S2 also prints5340t distribution steel versus5340kg drawing. Do not copy printed dimensional/recipe anomalies into newerTsiklios/PSIpipeline adapters. Current4847already fixes dust14.7kg/tonne and ammonia30.6g/tonne; preserve both. DOC/TOC may overlap; omittedDOC/wasteheat and current waste market versus source landfill require source-specific closure.
Publisher/Crossref/Crossmark ordered seven-author journal byline placesHake beforeStolten; institutional repository order differs. Jülich is the common verified parent institution; historicalIEK-STE/IEK-3 units are not separatefunders and currentdepartment names are not retroactive affiliations. RWTHdual affiliation is not established for this2018paper. Helmholtz funding is source-publication scoped, with no awardnumber. Institutional ES2050program listing supports a source-studyproject, but not an invented specific grant/funder-to-project award or funding of CLIC curation.
Crossmark reports documentcurrent; registry has no registeredupdate relation. Scoped DOI/title corrigendum, erratum and amendment searches located no authoritative notice. This is not exhaustive proof of absence or whole-model scientific signoff. Later compiler helper/refactoring and current CLIC editorial revisions are not publisher errata.
Materials and capacity
The source uses Das (2011) carbon fibre, while current CLIC uses a later Benitez-derived woven-fibre provider. Quantity agreement does not establish equivalent fibre/process. Source fibre inputs of 2.25 kg acrylonitrile, 0.20 kg vinyl acetate, 1.07 kg resin, 175 kWh heat and 26.2 kWh electricity/kg fibre are ancestry, not an instruction to replace current supply. No tank pressure or replacement frequency is inferred from a truck's 500 bar reference.

Evidence limits
The original publisher supplement was recovered. Main full text remains restricted; bibliographic API core and HTTP-200 HTML challenge pages do not establish detailed methods or complete acknowledgments. A software/LCIA version, complete background model or current department/RWTH affiliation is not inferred from another paper. Recorded publisher/registry/Crossmark and scoped correction searches located no authoritative applicable notice without proving complete absence. Later compiler refactoring and CLIC corrections are distinct from publisher errata.
Version metadata Intended application Not set Use of this specific equipment or auxiliary-service reference within an explicitly assembled hydrogen pathway, retaining capacity/throughput distinctions and caller ownership. Apply reviewed discovery metadata and change explanations from the curated release.
Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content