Description
Manufacture of one hydrogen refuelling station rated at 850 kg/day. Its recorded tank-service purchase represents lifetime storage-capacity provision, while hydrogen supply, compression and precooling belong to operational callers.
Hydrogen distribution
Reference product Hydrogen refuelling station GLO
Stable dataset identity
hydrogen-refuelling-station
1.0.1Published inventory
Process description and catalog context. View scientific metadata
Manufacture of one hydrogen refuelling station rated at 850 kg/day. Its recorded tank-service purchase represents lifetime storage-capacity provision, while hydrogen supply, compression and precooling belong to operational callers.
Classification, keywords, bookmarks and download counts.
Classification path: Energy > Hydrogen > Hydrogen distribution
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
A score could not be calculated because one or more inventory exchanges could not be linked to the UVEK 2025 screening background.
Missing factors are not treated as zero. The inventory remains available while the background mapping is corrected.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata |
|---|---|---|---|---|
|
Hydrogen refuelling station
GLO
|
hydrogen refuelling station
|
1
|
unit | - |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata |
|---|---|---|---|---|
|
market for steel, low-alloyed
GLO
|
steel, low-alloyed
|
2.66e+04
|
kilogram | - |
|
market for metal working, average for steel product manufacturing
GLO
|
metal working, average for steel product manufacturing
|
2.66e+04
|
kilogram | - |
|
market for steel, chromium steel 18/8
GLO
|
steel, chromium steel 18/8
|
5210
|
kilogram | - |
|
market for metal working, average for chromium steel product manufacturing
GLO
|
metal working, average for chromium steel product manufacturing
|
5210
|
kilogram | - |
|
market for cast iron
GLO
|
cast iron
|
2940
|
kilogram | - |
|
market for copper, anode
GLO
|
copper, anode
|
1180
|
kilogram | - |
|
market for metal working, average for copper product manufacturing
GLO
|
metal working, average for copper product manufacturing
|
1180
|
kilogram | - |
|
market for aluminium, wrought alloy
GLO
|
aluminium, wrought alloy
|
499
|
kilogram | |
|
market for metal working, average for aluminium product manufacturing
GLO
|
metal working, average for aluminium product manufacturing
|
499
|
kilogram | - |
|
market for phenolic resin
RER
|
phenolic resin
|
372
|
kilogram | - |
|
market for electronics, for control units
GLO
|
electronics, for control units
|
64
|
kilogram | - |
|
market for concrete, normal
RoW
|
concrete, normal
|
87.5
|
cubic meter | - |
|
market for waste concrete
RoW
|
waste concrete
|
-2.10e+05
|
kilogram | - |
|
high pressure hydrogen storage tank
|
250
|
kilogram | - |
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
First published inventory; no earlier version is available for comparison.
SupersededThe hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-11-03 | The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation. | Current view |
| Version 1.0.0 Superseded | Published 2026-07-15 | First published inventory; no earlier version is available for comparison. | Open version |
The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.
Pressure-vessel and station-design assumptions remain those of the source model.
Source: https://doi.org/10.1016/j.jclepro.2018.07.180.
Declared foreground licence: CC-BY-4.0. Source publications and external supplier inventories retain their own terms.
The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for aluminium, wrought alloy (technosphere / GLO / kilogram) | Amount | Not present | 499 kilogram | The aluminium, wrought alloy entry supplies the material, process or treatment required by the revised reference. The selected source correction applies to the actual component boundary, without changing the station service or claiming a new storage performance. The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for aluminium alloy, AlLi (technosphere / GLO / kilogram) | Amount | 499 kilogram | Not present | The former aluminium alloy, AlLi entry is superseded by the revised product/component boundary. The selected source correction applies to the actual component boundary, without changing the station service or claiming a new storage performance. The hydrogen-station or storage-tank reference now distinguishes the supplied tank/equipment materials from their fabrication and site allocation. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Version metadata | Capacity factor | Not set | 70.00 | No explanation was recorded for this change. |
| Version metadata | Description | Manufacture of one basic850kg/day hydrogen refuelling station; archived70percent utilization implies595kg/day. Metals, polymer/electronics proxies, concrete and signed waste-concrete demand are included. Current250kg tank-service purchase is lifetime hydrogen-storage capacity across two125kg purchases under40year station/20year tank lives, not dry vessel mass or250kg simultaneously installed storage. Compression, precooling, hydrogen supply and route-specific losses belong to operational callers. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. Wulf et al.(2018), Journal of Cleaner Production199,431–443, compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. The archived component references here cover only their stated manufacturing or auxiliary service, not an entire delivered-hydrogen pathway. Original SI and later premise adapter remain distinct. Publication2018 is not automatically inventory reference year; no software/LCIA method or background profile is inferred from another paper. |
Manufacture of one hydrogen refuelling station rated at 850 kg/day. Its recorded tank-service purchase represents lifetime storage-capacity provision, while hydrogen supply, compression and precooling belong to operational callers. | |
| Version metadata | Design capacity | Not set | 850.000000 | |
| Version metadata | Design capacity unit | Not set | kg/day | |
| Version metadata | Methodology and allocation explanation | Wulf et al.(2018), Journal of Cleaner Production199,431–443, compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. The archived component references here cover only their stated manufacturing or auxiliary service, not an entire delivered-hydrogen pathway. Original SI and later premise adapter remain distinct. Publication2018 is not automatically inventory reference year; no software/LCIA method or background profile is inferred from another paper. | Source model Wulf et al. (2018) compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. These components represent only the stated manufacture or auxiliary service. The original supplement and later premise adapter retain distinct roles; 2018 is not an inferred inventory reference year. Component basis Nominal 850 kg/day and selected 70% utilization imply 595 kg/day. The archived 40-year station/20-year tank lives give two purchases of 125 kg installed H2 capacity, or 250 kg lifetime capacity units. This is neither 250 kg dry vessel mass nor 250 kg simultaneous installed capacity. Concrete uses the compiler's 2,400 kg/m³ conversion. |
|
| Version metadata | Publication / citation | Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production,199,431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 | Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 | |
| Version metadata | Source | Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production,199,431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 | Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 | |
| Version metadata | Contributors, publications, projects and supporting evidence | Funding: 1. Project: Not set Funding: 1. Organization: Ror: https://ror.org/0281dp749 Funding: 1. Organization: Url: https://www.helmholtz.de/ Funding: 1. Organization: Name: Helmholtz Association of German Research Centres Funding: 1. Award identifier: Not set Evidence: 1. Origin: source_import Evidence: 1. Target field: publications Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: editor_verification Evidence: 2. Target field: publications Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 2. Source reference: https://api.crossref.org/works/10.1016%2Fj.jclepro.2018.07.180 Evidence: 3. Origin: source_import Evidence: 3. Target field: data_origins Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: source_import Evidence: 4. Target field: data_origins Evidence: 4. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 4. Source location: description Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: source_import Evidence: 5. Target field: technology_description Evidence: 5. Qualification: Only this supplied activity is described; whole-paper life-cycle boundaries not copied onto components. Evidence: 5. Source location: description Evidence: 5. Source reference: Existing published CLIC inventory documentation Evidence: 6. Origin: editor_verification Evidence: 6. Target field: publications Evidence: 6. Qualification: Seven authors in publisher order; all Jülich parent affiliation. HistoricalIEK-STE/IEK-3 units are retained as source context, not contemporary department substitutions or automatic RWTH affiliations. Evidence: 6. Source location: Publisher byline;Crossref;JuSER850627 Evidence: 6. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 7. Origin: editor_verification Evidence: 7. Target field: methodology_notes Evidence: 7. Qualification: Manufacture of one basic850kg/day hydrogen refuelling station; archived70percent utilization implies595kg/day. Metals, polymer/electronics proxies, concrete and signed waste-concrete demand are included. Current250kg tank-service purchase is lifetime hydrogen-storage capacity across two125kg purchases under40year station/20year tank lives, not dry vessel mass or250kg simultaneously installed storage. Compression, precooling, hydrogen supply and route-specific losses belong to operational callers. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. Quantity agreement is partial and does not certify supplier chemistry, source anomalies, coproduct allocation, loss ownership or uncertainty. Evidence: 7. Source location: S3–S8; exact quantities and source denominators Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S095965261832170X-mmc1.docx Evidence: 8. Origin: editor_verification Evidence: 8. Target field: funding Evidence: 8. Qualification: Helmholtz source-publication support has no awardnumber and projectlink remains null. ES2050 is a source-studyprogramme, not proof of funding of CLIC compilation or a specific award. Jülich member institution is distinct from umbrella Helmholtz funder. Evidence: 8. Source location: Crossmark funding;institutional research-program listing Evidence: 8. Source reference: https://crossmark.crossref.org/dialog/?doi=10.1016%2Fj.jclepro.2018.07.180 Projects: 1. Url: https://www.helmholtz.de/en/research/research-fields/energy/energy-system-2050/ Projects: 1. Name: Energy System 2050 – A Contribution of the Research Field Energy Projects: 1. Acronym: ES2050 Projects: 1. Relation: source_study Projects: 1. Grant identifier: Not set Publications: 1. Doi: 10.1016/j.jclepro.2018.07.180 Publications: 1. Url: https://doi.org/10.1016/j.jclepro.2018.07.180 Publications: 1. Title: Life Cycle Assessment of hydrogen transport and distribution options Publications: 1. Scientific authors: 1. Name: Christina Wulf Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 2. Name: Markus Reuß Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 3. Name: Thomas Grube Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 4. Name: Petra Zapp Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 5. Name: Martin Robinius Publications: 1. Scientific authors: 5. Orcid: 0000-0002-5307-3022 Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 6. Name: Jürgen-Friedrich Hake Publications: 1. Scientific authors: 6. Orcid: Not set Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 6. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 6. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 7. Name: Detlef Stolten Publications: 1. Scientific authors: 7. Orcid: Not set Publications: 1. Scientific authors: 7. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 7. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 7. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Citation: Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production,199,431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2018 |
Funding: 1. Project: Not set Funding: 1. Organization: Ror: https://ror.org/0281dp749 Funding: 1. Organization: Url: https://www.helmholtz.de/ Funding: 1. Organization: Name: Helmholtz Association of German Research Centres Funding: 1. Award identifier: Not set Evidence: 1. Origin: source_import Evidence: 1. Target field: publications Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: editor_verification Evidence: 2. Target field: publications Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 2. Source reference: https://api.crossref.org/works/10.1016%2Fj.jclepro.2018.07.180 Evidence: 3. Origin: source_import Evidence: 3. Target field: data_origins Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: source_import Evidence: 4. Target field: data_origins Evidence: 4. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 4. Source location: description Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: source_import Evidence: 5. Target field: technology_description Evidence: 5. Qualification: Only this supplied activity is described; whole-paper life-cycle boundaries not copied onto components. Evidence: 5. Source location: description Evidence: 5. Source reference: Existing published CLIC inventory documentation Evidence: 6. Origin: editor_verification Evidence: 6. Target field: publications Evidence: 6. Qualification: Seven authors in publisher order; all Jülich parent affiliation. HistoricalIEK-STE/IEK-3 units are retained as source context, not contemporary department substitutions or automatic RWTH affiliations. Evidence: 6. Source location: Publisher byline;Crossref;JuSER850627 Evidence: 6. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 7. Origin: editor_verification Evidence: 7. Target field: methodology_notes Evidence: 7. Qualification: Manufacture of one basic850kg/day hydrogen refuelling station; archived70percent utilization implies595kg/day. Metals, polymer/electronics proxies, concrete and signed waste-concrete demand are included. Current250kg tank-service purchase is lifetime hydrogen-storage capacity across two125kg purchases under40year station/20year tank lives, not dry vessel mass or250kg simultaneously installed storage. Compression, precooling, hydrogen supply and route-specific losses belong to operational callers. Quantity agreement is partial and does not certify supplier chemistry, source anomalies, coproduct allocation, loss ownership or uncertainty. Evidence: 7. Source location: S3–S8; exact quantities and source denominators Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S095965261832170X-mmc1.docx Evidence: 8. Origin: editor_verification Evidence: 8. Target field: funding Evidence: 8. Qualification: Helmholtz source-publication support has no awardnumber and projectlink remains null. ES2050 is a source-studyprogramme, not proof of funding of CLIC compilation or a specific award. Jülich member institution is distinct from umbrella Helmholtz funder. Evidence: 8. Source location: Crossmark funding;institutional research-program listing Evidence: 8. Source reference: https://crossmark.crossref.org/dialog/?doi=10.1016%2Fj.jclepro.2018.07.180 Evidence: 9. Origin: editor_verification Evidence: 9. Target field: methodology_notes Evidence: 9. Qualification: Manifest-verified historical decision NB-BOUNDED-2031. Preserve the identified prior repair and its source/profile qualifications. Exact agreement is not blanket approval of every other amount, provider, uncertainty or future version. Original decision rationale: Compose only the source-verified corrections recorded in audit ordinals 140; preserve the remaining curated model, original paired profiles and published history. Original qualification: The individual cited source/proxy and engineering limitations remain binding. No complete-model replacement, performance change, new recovery credit or blanket background migration is authorized. Specific prior repair evidence: Wulf2018 station TableS4 specifies499kg aluminium and tank TableS6 specifies6kgAl per10kgcapacity; it does not specify an aluminium-lithium aerospace alloy. Replacing that unusual alloy supplier by existing generic wrought aluminium at unchanged499kg station and0.6kg perkg H2capacity is a reasonable scoped correction. Generic wrought is still an alloy/grade proxy, not proof of pureAl or permission to set all alloying elements to zero or change background primary-secondary shares. Subsequent one-unit tank provider incorporates75kg at125kgcapacity, independently verified; no blanket correction of other alloy consumers is authorized. Evidence: 9. Source location: Historical preservation register P013/P014 or scoped H-series review; original encoding and approval boundaries retained Evidence: 9. Source reference: Manifest-verified prior correction/source/migration decisions and exact archive guards Evidence: 10. Origin: editor_verification Evidence: 10. Target field: technology_description Evidence: 10. Qualification: Technical-characterisation review TC-2031. Design capacity: 850.000000. Basis: Exact archived station model names850 kg/day; provision metadata describes the rated asset, while actual hydrogen supply/compression/precooling belong to operational callers. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 10. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 10. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: technology_description Evidence: 11. Qualification: Technical-characterisation review TC-2031. Design capacity unit: kg/day. Basis: Exact archived station model names850 kg/day; provision metadata describes the rated asset, while actual hydrogen supply/compression/precooling belong to operational callers. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 11. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 11. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 12. Origin: editor_verification Evidence: 12. Target field: technology_description Evidence: 12. Qualification: Technical-characterisation review TC-2031. Capacity factor (%): 70.00. Basis: Exact archived station nominal850 kg/day× selected 70% gives 595 kg/day; a model throughput-utilization factor for this station, not a measured duty record. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 12. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 12. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: technology_description Evidence: 13. Qualification: Technical-characterisation review TC-2031. Annual production volume: Unspecified. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 13. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 13. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-2031. Annual production volume unit: Unspecified. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 14. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-2031. Annual production volume year: Unspecified. Basis: No annual observation year is established by publication 2018, source-cited study dates or model construction/service calendars. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 15. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-2031. Plant or represented-asset lifetime (years): 40. Basis: Match own component/service and source/archived model scope. Preserve existing source technical lives and valid ratings; do not infer a complete facility or measured operation from a normalized material/process reference. Evidence classification: native supplement and archived model scope crosscheck. Confidence: high for model scope not measured operation. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: Native publisher SI TablesS4-S8; exact archived station/cavern assumptions Evidence: 16. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-2031. Commercial maturity stage: early_commercial. Basis: Retain existing earlycommercial maturity solely as a qualified source-era curator estimate of hydrogen refuelling or salt-cavern service-route context, not verification of the exact model's industrial performance. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json Evidence: 17. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-2031. Technology readiness level: Unspecified. Basis: Source mass/energy tables and archival route assumptions do not establish exact standalone earlycommercial/TRL8for this selected process or chemical recipe. Leave unsupported exact readiness unspecified; commercial constituent availability is not denied. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json Evidence: 18. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 19. Origin: editor_verification Evidence: 19. Target field: technology_description Evidence: 19. Qualification: Technical-characterisation review TC-2031. Technological representativeness: 4. Basis: Curator proxy score4for transferred equipment/materials and selected process, chemical or allocation assumptions, not an independently measured representative industrial inventory. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 19. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json Evidence: 19. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 20. Origin: editor_verification Evidence: 20. Target field: technology_description Evidence: 20. Qualification: Technical-characterisation review TC-2031. Geographical representativeness: 4. Basis: Curator score at least3for generic suppliers/equipment and regional transfers; retain broaderproxy4where already present. No production-weighted exact plant or regional sample established. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 20. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json Evidence: 20. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Evidence: 21. Origin: editor_verification Evidence: 21. Target field: technology_description Evidence: 21. Qualification: Technical-characterisation review TC-2031. Temporal representativeness: 4. Basis: Curator historical/mixed score4for2018andolder source inputs plus archived engineering assumptions. Publication and compilation dates do not establish a common observed inventory year. Evidence classification: native source boundary and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 21. Source location: Source SI TablesS4-S8 and exact archived reference; wulf-source-reading.json Evidence: 21. Source reference: https://doi.org/10.1016/j.jclepro.2018.07.180 Projects: 1. Url: https://www.helmholtz.de/en/research/research-fields/energy/energy-system-2050/ Projects: 1. Name: Energy System 2050 – A Contribution of the Research Field Energy Projects: 1. Acronym: ES2050 Projects: 1. Relation: source_study Projects: 1. Grant identifier: Not set Publications: 1. Doi: 10.1016/j.jclepro.2018.07.180 Publications: 1. Url: https://doi.org/10.1016/j.jclepro.2018.07.180 Publications: 1. Title: Life Cycle Assessment of hydrogen transport and distribution options Publications: 1. Scientific authors: 1. Name: Christina Wulf Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 2. Name: Markus Reuß Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 3. Name: Thomas Grube Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 4. Name: Petra Zapp Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 5. Name: Martin Robinius Publications: 1. Scientific authors: 5. Orcid: 0000-0002-5307-3022 Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 6. Name: Jürgen-Friedrich Hake Publications: 1. Scientific authors: 6. Orcid: Not set Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 6. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 6. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Scientific authors: 7. Name: Detlef Stolten Publications: 1. Scientific authors: 7. Orcid: Not set Publications: 1. Scientific authors: 7. Affiliations: 1. Ror: https://ror.org/02nv7yv05 Publications: 1. Scientific authors: 7. Affiliations: 1. Url: https://www.fz-juelich.de/ Publications: 1. Scientific authors: 7. Affiliations: 1. Name: Forschungszentrum Jülich Publications: 1. Citation: Wulf, C., Reuß, M., Grube, T., Zapp, P., Robinius, M., Hake, J.-F., & Stolten, D. (2018). Life Cycle Assessment of hydrogen transport and distribution options. Journal of Cleaner Production 199, 431–443. https://doi.org/10.1016/j.jclepro.2018.07.180 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2018 |
|
| Version metadata | System boundary | Manufacture of one basic850kg/day hydrogen refuelling station; archived70percent utilization implies595kg/day. Metals, polymer/electronics proxies, concrete and signed waste-concrete demand are included. Current250kg tank-service purchase is lifetime hydrogen-storage capacity across two125kg purchases under40year station/20year tank lives, not dry vessel mass or250kg simultaneously installed storage. Compression, precooling, hydrogen supply and route-specific losses belong to operational callers. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. Wulf et al.(2018), Journal of Cleaner Production199,431–443, compare wind-powered alkaline-electrolysis supply chains using LOHC trucks, compressed-gas trucks and cavern/pipeline routes, including seasonal storage. The archived component references here cover only their stated manufacturing or auxiliary service, not an entire delivered-hydrogen pathway. Original SI and later premise adapter remain distinct. Publication2018 is not automatically inventory reference year; no software/LCIA method or background profile is inferred from another paper. | The recorded whole-station construction and lifetime tank-capacity provision. Operational hydrogen supply, compression, precooling and route-specific loss flows are separate. | |
| Version metadata | Technological representativeness | 3 | 4 | |
| Version metadata | Technology description | Manufacture of one basic850kg/day hydrogen refuelling station; archived70percent utilization implies595kg/day. Metals, polymer/electronics proxies, concrete and signed waste-concrete demand are included. Current250kg tank-service purchase is lifetime hydrogen-storage capacity across two125kg purchases under40year station/20year tank lives, not dry vessel mass or250kg simultaneously installed storage. Compression, precooling, hydrogen supply and route-specific losses belong to operational callers. Superseded historical recipe; preserve current corrections rather than reverting from this historical evidence. | Basic hydrogen-station construction with metals, polymer/electronics proxies, concrete, signed waste-concrete demand and lifetime tank-capacity purchases. | |
| Version metadata | Technology readiness level | 8 | Not set | |
| Version metadata | Temporal representativeness | 3 | 4 | |
| Version metadata | Limitations on use | Original publisher SI is recovered and hashed. Main full text remains restricted at JuSER; Elsevier API supplies bibliographic core only and institutional HTTP200 probes are HTML challenge payloads. No verified detailed LCIA method, software version, complete background system model or main-text acknowledgments inferred from other papers. Station S4 is850 kg/day nominal; archived70 percent utilization gives595 kg/day. Station40year/tank20year lives are archived assumptions. S8 installed125 kg H2 capacity times two lifetime purchases equals current250 kg capacity units. Do not describe250 kg as vessel mass or simultaneous capacity. S6 dry materials12.6 kg/kgcapacity exclude2.4 kg forming services. Later unit125kg helper is absent from pinned CLIC snapshot and is not a missing originalpaper dataset or a proposed addition. S6 source carbon fibre uses Das2011 recipe (2.25kg acrylonitrile,0.20kg vinyl acetate,1.07kg resin,175kWh heat and26.2kWh electricity perkg fibre). CLIC references later Benitez-derived weaved fibre; quantity agreement does not certify fibre type, process or source equivalence. No measured tank pressure or replacement frequency inferred from truck500bar reference. S5 hydrogenation electricity666Wh versus current660Wh is a0.9 percent source/compiler difference, not within the half-percent comparison screen. One conditional current2043amount candidate records0.666kWh. Confirm source precision and intended incremental-service basis before new version; no publisher corrigendum establishes this as a corrected coefficient. Hydrogenation source10g H2/kg is absent from its auxiliary recipe. Neither hydrogenation nor dehydrogenation purchases basehydrogen; trace caller loss/makeup ownership before adding10g, full1kg or direct H2 emissions. Dehydrogenation9.5kWh heat equals current34.2MJ, and366Wh electricity matches. Existing dehydrogenation/DBT descriptions incorrectly repeat hydrogenation and1percentloss; correct component descriptions separately. DBT source2mg iron(III) chloride is mapped to2mg iron(III) sulfate in CLIC. Equal numerical mass does not establish chemistry equivalence; verify exact intended catalyst and available supplier without guessing a replacement UUID. Source535g HCl coproduct lacks solution concentration/allocation; pure535gHCl contains about520g chlorine, exceeding printed260gCl2, whereas535g of30percent solution would contain about156g chlorine. This conditional composition screen is not proof of a source error or permission for a coproduct credit. Source42.1kWh/kg electricity is copied exactly; high magnitude alone does not justify changing its unit. S7 construction water31.25kg and electricity0.09375kWh perkg agree with5millionm3 water and15,000MWh divided by4000t/year*40years.570kW is pump capacity;570/0.76=750kW electrical draw. Tap water remains a compiler provider proxy, with brine/resource/outlet ownership unresolved.2350t cushion is an initial stock; lifetime equivalent0.0146875kg/kg is not automatically recurring1.3percentloss. Storage service0.344kWh covers0.240compression+0.104drying; extra0.48return compression and1percentannualH2loss need caller-boundary review, not automatic addition. S3 pertonne coating source has heatCHP768kg, sodaash1000kg and no explicit bulkZn/Al/Si feed. Coating is an application/process recipe, not demonstrated production of1kg alloy. S2 also prints5340t distribution steel versus5340kg drawing. Do not copy printed dimensional/recipe anomalies into newerTsiklios/PSIpipeline adapters. Current4847already fixes dust14.7kg/tonne and ammonia30.6g/tonne; preserve both. DOC/TOC may overlap; omittedDOC/wasteheat and current waste market versus source landfill require source-specific closure. Publisher/Crossref/Crossmark ordered seven-author journal byline placesHake beforeStolten; institutional repository order differs. Jülich is the common verified parent institution; historicalIEK-STE/IEK-3 units are not separatefunders and currentdepartment names are not retroactive affiliations. RWTHdual affiliation is not established for this2018paper. Helmholtz funding is source-publication scoped, with no awardnumber. Institutional ES2050program listing supports a source-studyproject, but not an invented specific grant/funder-to-project award or funding of CLIC curation. Crossmark reports documentcurrent; registry has no registeredupdate relation. Scoped DOI/title corrigendum, erratum and amendment searches located no authoritative notice. This is not exhaustive proof of absence or whole-model scientific signoff. Later compiler helper/refactoring and current CLIC editorial revisions are not publisher errata. |
Capacity and operation The station/tank lives and utilization are selected assumptions. A later 125 kg unit helper is absent from this snapshot; its absence does not establish a missing original-paper dataset. Operational callers must own compression, precooling, supply and losses once. Evidence limits The original publisher supplement was recovered. Main full text remains restricted; bibliographic API core and HTTP-200 HTML challenge pages do not establish detailed methods or complete acknowledgments. A software/LCIA version, complete background model or current department/RWTH affiliation is not inferred from another paper. Recorded publisher/registry/Crossmark and scoped correction searches located no authoritative applicable notice without proving complete absence. Later compiler refactoring and CLIC corrections are distinct from publisher errata. |
|
| Version metadata | Intended application | Not set | Use of this specific equipment or auxiliary-service reference within an explicitly assembled hydrogen pathway, retaining capacity/throughput distinctions and caller ownership. | Apply reviewed discovery metadata and change explanations from the curated release. |
| Version metadata | Name | Hydrogen refuelling station | hydrogen refuelling station | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content