Description
Adapted bidirectional redox-flow battery converter, with declared output 1 unit.
Flow batteries
Reference product inverter, 5kW RER
Stable dataset identity
inverter-production-5kw
1.0.1Published inventory
Process description and catalog context. View scientific metadata
Adapted bidirectional redox-flow battery converter, with declared output 1 unit.
Classification, keywords, bookmarks and download counts.
Classification path: Materials > Batteries > Flow batteries
Log in to bookmarkSource documentation, background profiles and references.
Other
Supporting sources:
Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G
Texas Instruments (2015). Bidirectional DC-DC Converter. Design guide TIDUAI7, September 2015. https://www.ti.com/lit/ug/tiduai7/tiduai7.pdf
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-23 18:54 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
inverter production, 5kw
RER
|
inverter, 5kW
|
1
|
unit | - | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
MOSFET, CSD19536KCS, redox-flow battery converter
|
126
|
unit | - |
0.185334
mol H+-Eq / unit
7.2% of total
71.8766
kg CO2-Eq / unit
24.3% of total
427.783
CTUe / unit
18.9% of total
0.0443098
kg P-Eq / unit
6.5% of total
0.046711
kg N-Eq / unit
16.5% of total
0.342738
mol N-Eq / unit
12.9% of total
1.0260e-07
CTUh / unit
18.9% of total
3.7388e-06
CTUh / unit
12.0% of total
13.9352
kBq U235-Eq / unit
17.1% of total
283.39
dimensionless / unit
19.6% of total
1.2985e-05
kg CFC-11-Eq / unit
50.5% of total
1.4243e-06
disease incidence / unit
13.0% of total
0.124887
kg NMVOC-Eq / unit
12.4% of total
882.887
MJ, net calorific value / unit
22.0% of total
0.000701533
kg Sb-Eq / unit
1.6% of total
80.0339
m3 world Eq deprived / unit
2.7% of total
|
|
|
gate driver, UCC27524AQDRQ1, redox-flow battery converter
|
72
|
unit | - |
0.00683987
mol H+-Eq / unit
0.3% of total
1.70668
kg CO2-Eq / unit
0.6% of total
11.2079
CTUe / unit
0.5% of total
0.00360956
kg P-Eq / unit
0.5% of total
0.0014778
kg N-Eq / unit
0.5% of total
0.0120723
mol N-Eq / unit
0.5% of total
2.5237e-09
CTUh / unit
0.5% of total
9.9642e-08
CTUh / unit
0.3% of total
0.317536
kBq U235-Eq / unit
0.4% of total
8.18044
dimensionless / unit
0.6% of total
2.8432e-07
kg CFC-11-Eq / unit
1.1% of total
3.8810e-08
disease incidence / unit
0.4% of total
0.00392668
kg NMVOC-Eq / unit
0.4% of total
21.1224
MJ, net calorific value / unit
0.5% of total
0.000484039
kg Sb-Eq / unit
1.1% of total
3.0675
m3 world Eq deprived / unit
0.1% of total
|
|
|
microcontroller, TMS320F28035PNT, redox-flow battery converter
|
19
|
unit | - |
0.0412349
mol H+-Eq / unit
1.6% of total
7.71331
kg CO2-Eq / unit
2.6% of total
45.4099
CTUe / unit
2.0% of total
0.00427886
kg P-Eq / unit
0.6% of total
0.00484248
kg N-Eq / unit
1.7% of total
0.0343966
mol N-Eq / unit
1.3% of total
1.0817e-08
CTUh / unit
2.0% of total
3.7927e-07
CTUh / unit
1.2% of total
1.48766
kBq U235-Eq / unit
1.8% of total
28.9926
dimensionless / unit
2.0% of total
1.3989e-06
kg CFC-11-Eq / unit
5.4% of total
1.6376e-07
disease incidence / unit
1.5% of total
0.0142999
kg NMVOC-Eq / unit
1.4% of total
94.6526
MJ, net calorific value / unit
2.4% of total
9.9287e-05
kg Sb-Eq / unit
0.2% of total
8.42375
m3 world Eq deprived / unit
0.3% of total
|
|
|
SiC switch package manufacturing reference, 650 V, TO-247-3
|
6
|
unit | - |
0.00596004
mol H+-Eq / unit
0.2% of total
0.777348
kg CO2-Eq / unit
0.3% of total
3.99918
CTUe / unit
0.2% of total
0.00149358
kg P-Eq / unit
0.2% of total
0.000633475
kg N-Eq / unit
0.2% of total
0.00677117
mol N-Eq / unit
0.3% of total
9.2531e-10
CTUh / unit
0.2% of total
5.5791e-08
CTUh / unit
0.2% of total
0.208479
kBq U235-Eq / unit
0.3% of total
3.58527
dimensionless / unit
0.2% of total
8.2264e-09
kg CFC-11-Eq / unit
0.0% of total
2.8277e-08
disease incidence / unit
0.3% of total
0.00202408
kg NMVOC-Eq / unit
0.2% of total
10.9605
MJ, net calorific value / unit
0.3% of total
3.3553e-05
kg Sb-Eq / unit
0.1% of total
21.1616
m3 world Eq deprived / unit
0.7% of total
|
|
|
SiC switch package manufacturing reference, 1200 V, TO-247-3
|
6
|
unit | - |
0.00739816
mol H+-Eq / unit
0.3% of total
1.38203
kg CO2-Eq / unit
0.5% of total
5.8419
CTUe / unit
0.3% of total
0.00169507
kg P-Eq / unit
0.2% of total
0.000918075
kg N-Eq / unit
0.3% of total
0.00952825
mol N-Eq / unit
0.4% of total
1.2698e-09
CTUh / unit
0.2% of total
6.3102e-08
CTUh / unit
0.2% of total
0.372456
kBq U235-Eq / unit
0.5% of total
5.99172
dimensionless / unit
0.4% of total
1.4352e-08
kg CFC-11-Eq / unit
0.1% of total
4.1582e-08
disease incidence / unit
0.4% of total
0.00293296
kg NMVOC-Eq / unit
0.3% of total
19.4407
MJ, net calorific value / unit
0.5% of total
3.5365e-05
kg Sb-Eq / unit
0.1% of total
38.9529
m3 world Eq deprived / unit
1.3% of total
|
|
|
isolated gate driver, redox-flow battery converter
|
12
|
unit | - |
0.0064118
mol H+-Eq / unit
0.2% of total
2.33817
kg CO2-Eq / unit
0.8% of total
13.8483
CTUe / unit
0.6% of total
0.00136026
kg P-Eq / unit
0.2% of total
0.0014844
kg N-Eq / unit
0.5% of total
0.0106264
mol N-Eq / unit
0.4% of total
3.3134e-09
CTUh / unit
0.6% of total
1.1881e-07
CTUh / unit
0.4% of total
0.448969
kBq U235-Eq / unit
0.6% of total
8.78014
dimensionless / unit
0.6% of total
4.2484e-07
kg CFC-11-Eq / unit
1.7% of total
4.5678e-08
disease incidence / unit
0.4% of total
0.0039923
kg NMVOC-Eq / unit
0.4% of total
28.669
MJ, net calorific value / unit
0.7% of total
2.0443e-05
kg Sb-Eq / unit
0.0% of total
2.47585
m3 world Eq deprived / unit
0.1% of total
|
|
|
market for aluminium, cast alloy
GLO
|
aluminium, cast alloy
|
7.64
|
kilogram | - |
0.15327
mol H+-Eq / unit
5.9% of total
32.61
kg CO2-Eq / unit
11.0% of total
96.707
CTUe / unit
4.3% of total
0.00854321
kg P-Eq / unit
1.3% of total
0.0283142
kg N-Eq / unit
10.0% of total
0.227838
mol N-Eq / unit
8.6% of total
3.5790e-08
CTUh / unit
6.6% of total
5.9366e-07
CTUh / unit
1.9% of total
17.1733
kBq U235-Eq / unit
21.1% of total
65.9997
dimensionless / unit
4.6% of total
5.6644e-07
kg CFC-11-Eq / unit
2.2% of total
1.7423e-06
disease incidence / unit
15.9% of total
0.0843209
kg NMVOC-Eq / unit
8.4% of total
494.229
MJ, net calorific value / unit
12.3% of total
3.1423e-05
kg Sb-Eq / unit
0.1% of total
222.461
m3 world Eq deprived / unit
7.4% of total
BAFU:2025
|
|
market for copper, cathode
GLO
|
copper, cathode
|
3.06
|
kilogram | - |
0.477281
mol H+-Eq / unit
18.5% of total
4.92678
kg CO2-Eq / unit
1.7% of total
139.567
CTUe / unit
6.2% of total
0.160112
kg P-Eq / unit
23.5% of total
0.0323837
kg N-Eq / unit
11.4% of total
0.383914
mol N-Eq / unit
14.5% of total
6.5058e-08
CTUh / unit
12.0% of total
5.9982e-06
CTUh / unit
19.2% of total
1.47833
kBq U235-Eq / unit
1.8% of total
75.8705
dimensionless / unit
5.2% of total
1.0945e-07
kg CFC-11-Eq / unit
0.4% of total
1.0886e-06
disease incidence / unit
9.9% of total
0.100836
kg NMVOC-Eq / unit
10.0% of total
66.6394
MJ, net calorific value / unit
1.7% of total
0.00349757
kg Sb-Eq / unit
8.0% of total
3.76008
m3 world Eq deprived / unit
0.1% of total
BAFU:2025
|
|
market for steel, low-alloyed
GLO
|
steel, low-alloyed
|
1.45
|
kilogram | - |
0.00958732
mol H+-Eq / unit
0.4% of total
2.99664
kg CO2-Eq / unit
1.0% of total
6.56591
CTUe / unit
0.3% of total
0.00119259
kg P-Eq / unit
0.2% of total
0.00222081
kg N-Eq / unit
0.8% of total
0.023973
mol N-Eq / unit
0.9% of total
1.1775e-08
CTUh / unit
2.2% of total
6.6038e-08
CTUh / unit
0.2% of total
0.516522
kBq U235-Eq / unit
0.6% of total
7.07435
dimensionless / unit
0.5% of total
2.5796e-08
kg CFC-11-Eq / unit
0.1% of total
2.1417e-07
disease incidence / unit
2.0% of total
0.00951048
kg NMVOC-Eq / unit
0.9% of total
24.5114
MJ, net calorific value / unit
0.6% of total
3.1675e-05
kg Sb-Eq / unit
0.1% of total
0.592716
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
|
market for polypropylene, granulate
GLO
|
polypropylene, granulate
|
1.41
|
kilogram | - |
0.00768316
mol H+-Eq / unit
0.3% of total
2.96679
kg CO2-Eq / unit
1.0% of total
19.265
CTUe / unit
0.9% of total
0.000171782
kg P-Eq / unit
0.0% of total
0.00165363
kg N-Eq / unit
0.6% of total
0.0180712
mol N-Eq / unit
0.7% of total
4.6206e-10
CTUh / unit
0.1% of total
1.2445e-08
CTUh / unit
0.0% of total
0.102246
kBq U235-Eq / unit
0.1% of total
1.26799
dimensionless / unit
0.1% of total
6.0459e-08
kg CFC-11-Eq / unit
0.2% of total
9.7701e-08
disease incidence / unit
0.9% of total
0.00793921
kg NMVOC-Eq / unit
0.8% of total
97.0277
MJ, net calorific value / unit
2.4% of total
4.8586e-06
kg Sb-Eq / unit
0.0% of total
0.123648
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
market for capacitor, electrolyte type, > 2cm height
GLO
|
capacitor, electrolyte type, > 2cm height
|
0.41
|
kilogram | - |
0.0832859
mol H+-Eq / unit
3.2% of total
17.6796
kg CO2-Eq / unit
6.0% of total
89.6497
CTUe / unit
4.0% of total
0.0177405
kg P-Eq / unit
2.6% of total
0.0152993
kg N-Eq / unit
5.4% of total
0.148413
mol N-Eq / unit
5.6% of total
2.0444e-08
CTUh / unit
3.8% of total
6.9833e-07
CTUh / unit
2.2% of total
4.69575
kBq U235-Eq / unit
5.8% of total
91.8266
dimensionless / unit
6.3% of total
2.8510e-07
kg CFC-11-Eq / unit
1.1% of total
6.4622e-07
disease incidence / unit
5.9% of total
0.118299
kg NMVOC-Eq / unit
11.7% of total
249.295
MJ, net calorific value / unit
6.2% of total
0.0121399
kg Sb-Eq / unit
27.8% of total
305.941
m3 world Eq deprived / unit
10.2% of total
BAFU:2025
|
|
market for capacitor, film type, for through-hole mounting
GLO
|
capacitor, film type, for through-hole mounting
|
0.27
|
kilogram | - |
0.129847
mol H+-Eq / unit
5.0% of total
11.4409
kg CO2-Eq / unit
3.9% of total
119.633
CTUe / unit
5.3% of total
0.0320555
kg P-Eq / unit
4.7% of total
0.0143476
kg N-Eq / unit
5.1% of total
0.152374
mol N-Eq / unit
5.7% of total
2.6153e-08
CTUh / unit
4.8% of total
1.4955e-06
CTUh / unit
4.8% of total
2.53014
kBq U235-Eq / unit
3.1% of total
68.1669
dimensionless / unit
4.7% of total
2.5264e-07
kg CFC-11-Eq / unit
1.0% of total
5.9103e-07
disease incidence / unit
5.4% of total
0.0921705
kg NMVOC-Eq / unit
9.1% of total
162.319
MJ, net calorific value / unit
4.0% of total
0.0133464
kg Sb-Eq / unit
30.5% of total
191.875
m3 world Eq deprived / unit
6.4% of total
BAFU:2025
|
|
market for ferrite
GLO
|
ferrite
|
2.16
|
kilogram | - |
0.0145131
mol H+-Eq / unit
0.6% of total
2.63299
kg CO2-Eq / unit
0.9% of total
20.1935
CTUe / unit
0.9% of total
0.00103606
kg P-Eq / unit
0.2% of total
0.00402132
kg N-Eq / unit
1.4% of total
0.0429778
mol N-Eq / unit
1.6% of total
1.3651e-09
CTUh / unit
0.3% of total
2.4976e-08
CTUh / unit
0.1% of total
1.10103
kBq U235-Eq / unit
1.4% of total
16.7576
dimensionless / unit
1.2% of total
5.5848e-08
kg CFC-11-Eq / unit
0.2% of total
8.7277e-08
disease incidence / unit
0.8% of total
0.0144357
kg NMVOC-Eq / unit
1.4% of total
42.5831
MJ, net calorific value / unit
1.1% of total
7.2667e-06
kg Sb-Eq / unit
0.0% of total
0.795996
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
market for printed wiring board, for surface mounting, Pb free surface
GLO
|
printed wiring board, for surface mounting, Pb free surface
|
0.55
|
square meter | - |
1.23132
mol H+-Eq / unit
47.7% of total
110.291
kg CO2-Eq / unit
37.3% of total
1158.53
CTUe / unit
51.3% of total
0.365226
kg P-Eq / unit
53.6% of total
0.107609
kg N-Eq / unit
38.0% of total
1.04166
mol N-Eq / unit
39.3% of total
2.3959e-07
CTUh / unit
44.1% of total
1.7169e-05
CTUh / unit
55.0% of total
28.1976
kBq U235-Eq / unit
34.6% of total
507.064
dimensionless / unit
35.0% of total
8.8074e-06
kg CFC-11-Eq / unit
34.2% of total
3.9176e-06
disease incidence / unit
35.7% of total
0.359578
kg NMVOC-Eq / unit
35.6% of total
1449.06
MJ, net calorific value / unit
36.1% of total
0.00921904
kg Sb-Eq / unit
21.1% of total
1761.21
m3 world Eq deprived / unit
59.0% of total
BAFU:2025
|
|
market for resistor, surface-mounted
GLO
|
resistor, surface-mounted
|
0.01
|
kilogram | - |
0.143305
mol H+-Eq / unit
5.5% of total
1.58061
kg CO2-Eq / unit
0.5% of total
18.3811
CTUe / unit
0.8% of total
0.0223375
kg P-Eq / unit
3.3% of total
0.00424495
kg N-Eq / unit
1.5% of total
0.0434606
mol N-Eq / unit
1.6% of total
3.3055e-09
CTUh / unit
0.6% of total
2.0689e-07
CTUh / unit
0.7% of total
0.280402
kBq U235-Eq / unit
0.3% of total
21.0795
dimensionless / unit
1.5% of total
3.4360e-08
kg CFC-11-Eq / unit
0.1% of total
1.7089e-07
disease incidence / unit
1.6% of total
0.0187135
kg NMVOC-Eq / unit
1.9% of total
21.7019
MJ, net calorific value / unit
0.5% of total
0.00380443
kg Sb-Eq / unit
8.7% of total
15.9036
m3 world Eq deprived / unit
0.5% of total
BAFU:2025
|
|
diode production, glass-, for surface-mounting
GLO
|
diode, glass-, for surface-mounting
|
0.01
|
kilogram | - |
0.00790402
mol H+-Eq / unit
0.3% of total
1.88007
kg CO2-Eq / unit
0.6% of total
6.71725
CTUe / unit
0.3% of total
0.00200299
kg P-Eq / unit
0.3% of total
0.00170038
kg N-Eq / unit
0.6% of total
0.0159011
mol N-Eq / unit
0.6% of total
1.3992e-09
CTUh / unit
0.3% of total
4.8788e-08
CTUh / unit
0.2% of total
0.634874
kBq U235-Eq / unit
0.8% of total
8.08779
dimensionless / unit
0.6% of total
3.2158e-08
kg CFC-11-Eq / unit
0.1% of total
4.9247e-08
disease incidence / unit
0.4% of total
0.00479433
kg NMVOC-Eq / unit
0.5% of total
28.7635
MJ, net calorific value / unit
0.7% of total
7.6431e-05
kg Sb-Eq / unit
0.2% of total
33.4367
m3 world Eq deprived / unit
1.1% of total
BAFU:2025
|
|
market for electric connector, wire clamp
GLO
|
electric connector, wire clamp
|
0.01
|
kilogram | - |
0.00081231
mol H+-Eq / unit
0.0% of total
0.0668685
kg CO2-Eq / unit
0.0% of total
1.1108
CTUe / unit
0.0% of total
0.000232013
kg P-Eq / unit
0.0% of total
0.00011638
kg N-Eq / unit
0.0% of total
0.00146248
mol N-Eq / unit
0.1% of total
1.0616e-10
CTUh / unit
0.0% of total
5.7992e-09
CTUh / unit
0.0% of total
0.0299783
kBq U235-Eq / unit
0.0% of total
0.474661
dimensionless / unit
0.0% of total
1.0814e-09
kg CFC-11-Eq / unit
0.0% of total
7.1685e-09
disease incidence / unit
0.1% of total
0.000364453
kg NMVOC-Eq / unit
0.0% of total
1.09355
MJ, net calorific value / unit
0.0% of total
1.4043e-05
kg Sb-Eq / unit
0.0% of total
0.0860482
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
wire drawing, copper
RER
|
wire drawing, copper
|
3.06
|
kilogram | - |
0.0208577
mol H+-Eq / unit
0.8% of total
1.14264
kg CO2-Eq / unit
0.4% of total
8.26231
CTUe / unit
0.4% of total
0.00670928
kg P-Eq / unit
1.0% of total
0.00174633
kg N-Eq / unit
0.6% of total
0.0192785
mol N-Eq / unit
0.7% of total
3.2152e-09
CTUh / unit
0.6% of total
2.4285e-07
CTUh / unit
0.8% of total
0.5776
kBq U235-Eq / unit
0.7% of total
7.04287
dimensionless / unit
0.5% of total
2.8588e-08
kg CFC-11-Eq / unit
0.1% of total
5.5775e-08
disease incidence / unit
0.5% of total
0.00842693
kg NMVOC-Eq / unit
0.8% of total
19.4976
MJ, net calorific value / unit
0.5% of total
0.000139379
kg Sb-Eq / unit
0.3% of total
0.487808
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
section bar extrusion, aluminium
RER
|
section bar extrusion, aluminium
|
7.64
|
kilogram | - |
0.0153616
mol H+-Eq / unit
0.6% of total
5.44561
kg CO2-Eq / unit
1.8% of total
21.7072
CTUe / unit
1.0% of total
0.00253055
kg P-Eq / unit
0.4% of total
0.00320593
kg N-Eq / unit
1.1% of total
0.0291115
mol N-Eq / unit
1.1% of total
4.4493e-09
CTUh / unit
0.8% of total
4.3590e-08
CTUh / unit
0.1% of total
3.75989
kBq U235-Eq / unit
4.6% of total
54.0988
dimensionless / unit
3.7% of total
1.3411e-07
kg CFC-11-Eq / unit
0.5% of total
1.1967e-07
disease incidence / unit
1.1% of total
0.0105113
kg NMVOC-Eq / unit
1.0% of total
100.506
MJ, net calorific value / unit
2.5% of total
6.9646e-06
kg Sb-Eq / unit
0.0% of total
8.02592
m3 world Eq deprived / unit
0.3% of total
BAFU:2025
|
|
sheet rolling, steel
RER
|
sheet rolling, steel
|
1.45
|
kilogram | - |
0.00137931
mol H+-Eq / unit
0.1% of total
0.549279
kg CO2-Eq / unit
0.2% of total
1.54281
CTUe / unit
0.1% of total
0.000158937
kg P-Eq / unit
0.0% of total
0.000350707
kg N-Eq / unit
0.1% of total
0.00356374
mol N-Eq / unit
0.1% of total
5.1368e-10
CTUh / unit
0.1% of total
7.5092e-09
CTUh / unit
0.0% of total
0.159357
kBq U235-Eq / unit
0.2% of total
1.63237
dimensionless / unit
0.1% of total
9.4863e-09
kg CFC-11-Eq / unit
0.0% of total
2.8324e-08
disease incidence / unit
0.3% of total
0.00163434
kg NMVOC-Eq / unit
0.2% of total
6.56708
MJ, net calorific value / unit
0.2% of total
4.2443e-07
kg Sb-Eq / unit
0.0% of total
0.115635
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
market group for electricity, medium voltage
GLO
|
electricity, medium voltage
|
16.9
|
kilowatt hour | - |
0.0230238
mol H+-Eq / unit
0.9% of total
9.71494
kg CO2-Eq / unit
3.3% of total
29.5905
CTUe / unit
1.3% of total
0.00321621
kg P-Eq / unit
0.5% of total
0.00456457
kg N-Eq / unit
1.6% of total
0.0441903
mol N-Eq / unit
1.7% of total
5.5292e-09
CTUh / unit
1.0% of total
1.1693e-07
CTUh / unit
0.4% of total
2.63101
kBq U235-Eq / unit
3.2% of total
38.6102
dimensionless / unit
2.7% of total
9.8230e-08
kg CFC-11-Eq / unit
0.4% of total
2.1365e-07
disease incidence / unit
1.9% of total
0.0145667
kg NMVOC-Eq / unit
1.4% of total
136.196
MJ, net calorific value / unit
3.4% of total
4.7505e-06
kg Sb-Eq / unit
0.0% of total
286.194
m3 world Eq deprived / unit
9.6% of total
BAFU:2025
|
|
market for heat, district or industrial, natural gas
RoW
|
heat, district or industrial, natural gas
|
5.72
|
megajoule | - |
0.000416153
mol H+-Eq / unit
0.0% of total
0.290319
kg CO2-Eq / unit
0.1% of total
0.896599
CTUe / unit
0.0% of total
4.8187e-06
kg P-Eq / unit
0.0% of total
0.000196796
kg N-Eq / unit
0.1% of total
0.00208049
mol N-Eq / unit
0.1% of total
1.9406e-11
CTUh / unit
0.0% of total
4.6784e-10
CTUh / unit
0.0% of total
0.00533037
kBq U235-Eq / unit
0.0% of total
0.139481
dimensionless / unit
0.0% of total
6.5456e-09
kg CFC-11-Eq / unit
0.0% of total
2.0367e-09
disease incidence / unit
0.0% of total
0.00079762
kg NMVOC-Eq / unit
0.1% of total
4.64031
MJ, net calorific value / unit
0.1% of total
5.0918e-08
kg Sb-Eq / unit
0.0% of total
0.0316711
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
|
market for heat, district or industrial, other than natural gas
RoW
|
heat, district or industrial, other than natural gas
|
0.36
|
megajoule | - |
0.000306918
mol H+-Eq / unit
0.0% of total
0.0378123
kg CO2-Eq / unit
0.0% of total
0.06409
CTUe / unit
0.0% of total
1.3619e-05
kg P-Eq / unit
0.0% of total
3.8103e-05
kg N-Eq / unit
0.0% of total
0.000399259
mol N-Eq / unit
0.0% of total
1.0033e-11
CTUh / unit
0.0% of total
3.4191e-10
CTUh / unit
0.0% of total
0.00161547
kBq U235-Eq / unit
0.0% of total
0.0741394
dimensionless / unit
0.0% of total
1.1140e-10
kg CFC-11-Eq / unit
0.0% of total
4.4325e-09
disease incidence / unit
0.0% of total
0.000119333
kg NMVOC-Eq / unit
0.0% of total
0.337935
MJ, net calorific value / unit
0.0% of total
3.7311e-09
kg Sb-Eq / unit
0.0% of total
0.00195403
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
|
market for corrugated board box
RER
|
corrugated board box
|
2.91
|
kilogram | - |
0.0104733
mol H+-Eq / unit
0.4% of total
3.22276
kg CO2-Eq / unit
1.1% of total
11.6574
CTUe / unit
0.5% of total
0.000941839
kg P-Eq / unit
0.1% of total
0.00546773
kg N-Eq / unit
1.9% of total
0.0377022
mol N-Eq / unit
1.4% of total
1.5106e-09
CTUh / unit
0.3% of total
2.9534e-08
CTUh / unit
0.1% of total
0.575077
kBq U235-Eq / unit
0.7% of total
142.27
dimensionless / unit
9.8% of total
9.1883e-08
kg CFC-11-Eq / unit
0.4% of total
1.8314e-07
disease incidence / unit
1.7% of total
0.0111893
kg NMVOC-Eq / unit
1.1% of total
46.1446
MJ, net calorific value / unit
1.2% of total
6.1809e-06
kg Sb-Eq / unit
0.0% of total
1.28337
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
market for packaging film, low density polyethylene
GLO
|
packaging film, low density polyethylene
|
0.02
|
kilogram | - |
0.000133021
mol H+-Eq / unit
0.0% of total
0.0528024
kg CO2-Eq / unit
0.0% of total
0.353539
CTUe / unit
0.0% of total
6.1291e-06
kg P-Eq / unit
0.0% of total
3.1487e-05
kg N-Eq / unit
0.0% of total
0.00033604
mol N-Eq / unit
0.0% of total
8.6554e-10
CTUh / unit
0.2% of total
2.3989e-10
CTUh / unit
0.0% of total
0.00737722
kBq U235-Eq / unit
0.0% of total
0.175112
dimensionless / unit
0.0% of total
4.5385e-09
kg CFC-11-Eq / unit
0.0% of total
1.4753e-09
disease incidence / unit
0.0% of total
0.000152877
kg NMVOC-Eq / unit
0.0% of total
1.46682
MJ, net calorific value / unit
0.0% of total
7.9389e-08
kg Sb-Eq / unit
0.0% of total
0.308933
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
|
market for waste paperboard, unsorted
RoW
|
waste paperboard, unsorted
|
-2.91
|
kilogram | - |
-0.00140458
mol H+-Eq / unit
-0.1% of total
-0.229745
kg CO2-Eq / unit
-0.1% of total
-0.555135
CTUe / unit
0.0% of total
-1.4988e-05
kg P-Eq / unit
0.0% of total
-0.000552158
kg N-Eq / unit
-0.2% of total
-0.00592881
mol N-Eq / unit
-0.2% of total
-5.5843e-11
CTUh / unit
0.0% of total
-1.1742e-09
CTUh / unit
0.0% of total
-0.0202575
kBq U235-Eq / unit
0.0% of total
-0.909722
dimensionless / unit
-0.1% of total
-6.5465e-09
kg CFC-11-Eq / unit
0.0% of total
-1.8336e-08
disease incidence / unit
-0.2% of total
-0.00213587
kg NMVOC-Eq / unit
-0.2% of total
-3.14054
MJ, net calorific value / unit
-0.1% of total
-3.1701e-07
kg Sb-Eq / unit
0.0% of total
-0.14854
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
|
market for waste polyethylene
RoW
|
waste polyethylene
|
-0.02
|
kilogram | - |
4.8099e-06
mol H+-Eq / unit
0.0% of total
0.0142394
kg CO2-Eq / unit
0.0% of total
0.0586827
CTUe / unit
0.0% of total
1.6585e-08
kg P-Eq / unit
0.0% of total
8.1140e-06
kg N-Eq / unit
0.0% of total
2.6213e-05
mol N-Eq / unit
0.0% of total
2.4343e-11
CTUh / unit
0.0% of total
1.0900e-10
CTUh / unit
0.0% of total
1.8147e-05
kBq U235-Eq / unit
0.0% of total
0.00500969
dimensionless / unit
0.0% of total
5.8695e-12
kg CFC-11-Eq / unit
0.0% of total
7.4092e-09
disease incidence / unit
0.1% of total
1.3901e-05
kg NMVOC-Eq / unit
0.0% of total
0.00244612
MJ, net calorific value / unit
0.0% of total
2.7543e-10
kg Sb-Eq / unit
0.0% of total
0.00018054
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
|
market for waste electric and electronic equipment
GLO
|
waste electric and electronic equipment
|
-18.49
|
kilogram | - |
0.00113841
mol H+-Eq / unit
0.0% of total
0.239837
kg CO2-Eq / unit
0.1% of total
1.04533
CTUe / unit
0.0% of total
0.000106614
kg P-Eq / unit
0.0% of total
0.000338313
kg N-Eq / unit
0.1% of total
0.00406528
mol N-Eq / unit
0.2% of total
3.6363e-10
CTUh / unit
0.1% of total
2.2134e-08
CTUh / unit
0.1% of total
0.285493
kBq U235-Eq / unit
0.4% of total
2.30692
dimensionless / unit
0.2% of total
1.0901e-08
kg CFC-11-Eq / unit
0.0% of total
1.0707e-08
disease incidence / unit
0.1% of total
0.00125421
kg NMVOC-Eq / unit
0.1% of total
5.39525
MJ, net calorific value / unit
0.1% of total
2.8360e-06
kg Sb-Eq / unit
0.0% of total
0.774665
m3 world Eq deprived / unit
0.0% of total
Mapped treatment or supply model
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
First published inventory; no earlier version is available for comparison.
SupersededThe flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. Semiconductor packages, controls and periphery…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-11-03 | The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. Semiconductor packages, controls and periphery follow that two-stage architecture. | Current view |
| Version 1.0.0 Superseded | Published 2026-07-15 | First published inventory; no earlier version is available for comparison. | Open version |
The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. Semiconductor packages, controls and periphery follow that two-stage architecture.
The 18-module DC reference, adapted control voltage, isolation, current sharing and proprietary material fractions remain engineering assumptions.
Source: https://doi.org/10.1039/D4EB00027G.
Declared foreground licence: CC-BY-3.0. Source publications and external supplier inventories retain their own terms.
The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. Semiconductor packages, controls and periphery follow that two-stage architecture.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for aluminium, cast alloy (technosphere / GLO / kilogram) | Database | cutoff39 | Not set | The supplier’s current product, location and database profile identify the input, replacing an import-specific link identifier. |
| market for copper, cathode (technosphere / GLO / kilogram) | Database | cutoff39 | Not set | |
| market for capacitor, electrolyte type, > 2cm height (technosphere / GLO / kilogram) | Database | cutoff39 | Not set | |
| market for capacitor, film type, for through-hole mounting (technosphere / GLO / kilogram) | Database | cutoff39 | Not set | |
| diode production, glass-, for surface-mounting (technosphere / GLO / kilogram) | Database | cutoff39 | Not set | |
| wire drawing, copper (technosphere / RER / kilogram) | Database | cutoff39 | Not set | |
| section bar extrusion, aluminium (technosphere / RER / kilogram) | Database | cutoff39 | Not set | |
| sheet rolling, steel (technosphere / RER / kilogram) | Database | cutoff39 | Not set | |
| market for corrugated board box (technosphere / RER / kilogram) | Database | cutoff39 | Not set | |
| market for waste paperboard, unsorted (technosphere / RoW / kilogram) | Database | cutoff39 | Not set | |
| diode production, glass-, for surface-mounting (technosphere / GLO / kilogram) | Amount | 0.00322 | 0.01 | The quantity of diode, glass-, for surface-mounting follows the selected material or process reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for corrugated board box (technosphere / RER / kilogram) | Amount | 1.06 | 2.91 | The quantity of corrugated board box follows the selected material or process reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| metal-oxide-semiconductor field-effect transistor production, csd19536kcs, redox-flow battery converter (technosphere / GLO / unit) | Amount | Not present | 126 unit | The MOSFET, CSD19536KCS, redox-flow battery converter entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| gate driver production, ucc27524aqdrq1, redox-flow battery converter (technosphere / GLO / unit) | Amount | Not present | 72 unit | The gate driver, UCC27524AQDRQ1, redox-flow battery converter entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| microcontroller production, tms320f28035pnt, redox-flow battery converter (technosphere / GLO / unit) | Amount | Not present | 19 unit | The microcontroller, TMS320F28035PNT, redox-flow battery converter entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| package production, silicon carbide switch reference, 650 v, to-247-3 (technosphere / GLO / unit) | Amount | Not present | 6 unit | The SiC switch package manufacturing reference, 650 V, TO-247-3 entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| package production, silicon carbide switch reference, 1200 v, to-247-3 (technosphere / GLO / unit) | Amount | Not present | 6 unit | The SiC switch package manufacturing reference, 1200 V, TO-247-3 entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| isolated gate driver production, redox-flow battery converter (technosphere / GLO / unit) | Amount | Not present | 12 unit | The isolated gate driver, redox-flow battery converter entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for steel, low-alloyed (technosphere / GLO / kilogram) | Amount | Not present | 1.45 kilogram | The steel, low-alloyed entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for polypropylene, granulate (technosphere / GLO / kilogram) | Amount | Not present | 1.41 kilogram | The polypropylene, granulate entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for ferrite (technosphere / GLO / kilogram) | Amount | Not present | 2.16 kilogram | The ferrite entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for printed wiring board, for surface mounting, Pb free surface (technosphere / GLO / square meter) | Amount | Not present | 0.55 square meter | The printed wiring board, for surface mounting, Pb free surface entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for resistor, surface-mounted (technosphere / GLO / kilogram) | Amount | Not present | 0.01 kilogram | The resistor, surface-mounted entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for electric connector, wire clamp (technosphere / GLO / kilogram) | Amount | Not present | 0.01 kilogram | The electric connector, wire clamp entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market group for electricity, medium voltage (technosphere / GLO / kilowatt hour) | Amount | Not present | 16.9 kilowatt hour | The electricity, medium voltage entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for heat, district or industrial, natural gas (technosphere / RoW / megajoule) | Amount | Not present | 5.72 megajoule | The heat, district or industrial, natural gas entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for heat, district or industrial, other than natural gas (technosphere / RoW / megajoule) | Amount | Not present | 0.361 megajoule | The heat, district or industrial, other than natural gas entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for packaging film, low density polyethylene (technosphere / GLO / kilogram) | Amount | Not present | 0.0184 kilogram | The packaging film, low density polyethylene entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for waste polyethylene (technosphere / RoW / kilogram) | Amount | Not present | -0.0184 kilogram | The waste polyethylene entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for waste electric and electronic equipment (technosphere / GLO / kilogram) | Amount | Not present | -18.491259364830004 kilogram | The waste electric and electronic equipment entry supplies the material, process or treatment required by the revised reference. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| aluminium alloy production, AlMg3 (technosphere / RER / kilogram) | Amount | 0.339 kilogram | Not present | The former aluminium alloy, AlMg3 entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| cable production, connector for computer, without plugs (technosphere / GLO / meter) | Amount | 0.21 meter | Not present | The former cable, connector for computer, without plugs entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| cable production, ribbon cable, 20-pin, with plugs (technosphere / GLO / kilogram) | Amount | 0.000384 kilogram | Not present | The former cable, ribbon cable, 20-pin, with plugs entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| capacitor production, electrolyte type, < 2cm height (technosphere / GLO / kilogram) | Amount | 0.0108 kilogram | Not present | The former capacitor, electrolyte type, < 2cm height entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| electric connector production, wire clamp (technosphere / GLO / kilogram) | Amount | 0.0391 kilogram | Not present | The former electric connector, wire clamp entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| ferrite production (technosphere / GLO / kilogram) | Amount | 0.0559 kilogram | Not present | The former ferrite entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| ferrite production (technosphere / GLO / kilogram) | Amount | 4.09e-05 kilogram | Not present | |
| folding boxboard carton production (technosphere / RER / kilogram) | Amount | 1.85 kilogram | Not present | The former folding boxboard carton entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| glass fibre reinforced plastic production, polyamide, injection moulded (technosphere / RER / kilogram) | Amount | 0.209 kilogram | Not present | The former glass fibre reinforced plastic, polyamide, injection moulded entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| glass fibre reinforced plastic production, polyamide, injection moulded (technosphere / RER / kilogram) | Amount | 0.041 kilogram | Not present | |
| heat production, light fuel oil, at industrial furnace 1MW (technosphere / Europe without Switzerland / megajoule) | Amount | 0.361 megajoule | Not present | The former heat, district or industrial, other than natural gas entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| heat production, natural gas, at industrial furnace >100kW (technosphere / Europe without Switzerland / megajoule) | Amount | 5.72 megajoule | Not present | The former heat, district or industrial, natural gas entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| inductor production, miniature radio frequency chip (technosphere / GLO / kilogram) | Amount | 0.00177 kilogram | Not present | The former inductor, miniature radio frequency chip entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| inductor production, ring core choke type (technosphere / GLO / kilogram) | Amount | 0.209 kilogram | Not present | The former inductor, ring core choke type entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| integrated circuit production, logic type (technosphere / GLO / kilogram) | Amount | 0.106 kilogram | Not present | The former integrated circuit, logic type entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for integrated circuit, logic type (technosphere / GLO / kilogram) | Amount | 0.249 kilogram | Not present | |
| integrated circuit production, memory type (technosphere / GLO / kilogram) | Amount | 0.003 kilogram | Not present | The former integrated circuit, memory type entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| light emitting diode production (technosphere / GLO / kilogram) | Amount | 2.31e-05 kilogram | Not present | The former light emitting diode entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for capacitor, tantalum-, for through-hole mounting (technosphere / GLO / kilogram) | Amount | 0.00214 kilogram | Not present | The former capacitor, tantalum-, for through-hole mounting entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for heat, for reuse in municipal waste incineration only (technosphere / CH / megajoule) | Amount | 14.7 megajoule | Not present | The former heat, for reuse in municipal waste incineration only entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for printed wiring board, for through-hole mounting, Pb containing surface (technosphere / GLO / square meter) | Amount | 0 square meter | Not present | The former printed wiring board, for through-hole mounting, Pb containing surface entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for printed wiring board, for through-hole mounting, Pb free surface (technosphere / GLO / square meter) | Amount | 0.162 square meter | Not present | The former printed wiring board, for through-hole mounting, Pb free surface entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for steel, low-alloyed, hot rolled (technosphere / GLO / kilogram) | Amount | 1.45 kilogram | Not present | The former steel, low-alloyed, hot rolled entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for styrene-acrylonitrile copolymer (technosphere / GLO / kilogram) | Amount | 0.01 kilogram | Not present | The former styrene-acrylonitrile copolymer entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for tap water (technosphere / Europe without Switzerland / kilogram) | Amount | 31.8 kilogram | Not present | The former tap water entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for transistor, auxilliaries and energy use (technosphere / GLO / kilogram) | Amount | 0.0307 kilogram | Not present | The former transistor, auxilliaries and energy use entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market for used printed wiring boards (technosphere / GLO / kilogram) | Amount | -1.96 kilogram | Not present | The former used printed wiring boards entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market group for electricity, medium voltage (technosphere / RER / kilowatt hour) | Amount | 16.9 kilowatt hour | Not present | The former electricity, medium voltage entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| market group for waste polyethylene (technosphere / RER / kilogram) | Amount | -0.0184 kilogram | Not present | The former waste polyethylene entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| metal working factory construction (technosphere / RER / unit) | Amount | 1.76e-08 unit | Not present | The former metal working factory entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| metal working, average for steel product manufacturing (technosphere / RER / kilogram) | Amount | 0.0308 kilogram | Not present | The former metal working, average for steel product manufacturing entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| packaging film production, low density polyethylene (technosphere / RER / kilogram) | Amount | 0.0184 kilogram | Not present | The former packaging film, low density polyethylene entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| plug production, inlet and outlet, for network cable (technosphere / GLO / unit) | Amount | 5.58 unit | Not present | The former plug, inlet and outlet, for network cable entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| plug production, inlet and outlet, for network cable (technosphere / GLO / unit) | Amount | 0.447 unit | Not present | |
| polycarbonate production (technosphere / RER / kilogram) | Amount | 0.324 kilogram | Not present | The former polycarbonate entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| polypropylene production, granulate (technosphere / RER / kilogram) | Amount | 1.41 kilogram | Not present | The former polypropylene, granulate entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| resistor production, surface-mounted (technosphere / GLO / kilogram) | Amount | 0.00733 kilogram | Not present | The former resistor, surface-mounted entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| resistor production, wirewound, through-hole mounting (technosphere / GLO / kilogram) | Amount | 0.00179 kilogram | Not present | The former resistor, wirewound, through-hole mounting entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| tin production (technosphere / RoW / kilogram) | Amount | 0.0154 kilogram | Not present | The former tin entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| transformer production, low voltage use (technosphere / GLO / kilogram) | Amount | 0.0643 kilogram | Not present | The former transformer, low voltage use entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| transistor production, surface-mounted (technosphere / GLO / kilogram) | Amount | 0.0669 kilogram | Not present | The former transistor, surface-mounted entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| treatment of hazardous waste, hazardous waste incineration (technosphere / Europe without Switzerland / kilogram) | Amount | -0.0206 kilogram | Not present | The former hazardous waste, for incineration entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| treatment of municipal solid waste, incineration (technosphere / CH / kilogram) | Amount | -0.389 kilogram | Not present | The former municipal solid waste entry is superseded by the revised product/component boundary. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. The flow-battery converter now represents a bidirectional low-voltage DC stage feeding an AC conversion stage, replacing the solar-inverter proxy. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Heat, waste (biosphere / air / megajoule) | Amount | 60.9 megajoule | Not present | Remove the old solar-inverter waste heat allowance when replacing its manufacturing inventory with the two-stage bidirectional flow-battery converter reference. The adopted model retains explicit assembly energy and component supply burdens; these old device-specific direct flows have no established coefficient for the new topology. This is a boundary choice, not a measured absence of waste heat. |
| Water, unspecified natural origin (biosphere / natural resource / in water / cubic meter) | Amount | 0.0606 cubic meter | Not present | Remove the old solar-inverter direct water extraction allowance when replacing its manufacturing inventory with the two-stage bidirectional flow-battery converter reference. The adopted model retains explicit assembly energy and component supply burdens; these old device-specific direct flows have no established coefficient for the new topology. This is a boundary choice, not a measured absence of direct water extraction. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| inverter production, 5kw (production / RER / unit) | Database | vanadium-organic-and-hybrid-redox-flow-battery | Not set | The supplier’s current product, location and database profile identify the input, replacing an import-specific link identifier. |
| Linked database record | vanadium-organic-and-hybrid-redox-flow-battery / 1b7fc06b9f09d64abb52e590241c817b | Not set | ||
| inverter production, 5kw (production / RER / unit) | Name | inverter production, 5kW | inverter production, 5kw | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Inventory file | Activity type | process | Not set | The metadata now states the characteristics of the supplied product and reference basis. The low-voltage battery needs a conversion topology and component count appropriate to bidirectional power flow, not a proportional reduction of an unrelated inverter. |
| Inventory file | Exchange type | process | processwithreferenceproduct | |
| Inventory file | Code | 1b7fc06b9f09d64abb52e590241c817b | Not set | The technical source identifier now agrees with the inventory’s supplied product and source namespace. |
| Inventory file | Database | vanadium-organic-and-hybrid-redox-flow-battery | Not set | |
| Version metadata | Commercial maturity stage | pilot | Not set | No explanation was recorded for this change. |
| Version metadata | Geographical representativeness | 2 | 3 | |
| Version metadata | Methodology and allocation explanation | Source review: Zhang et al. (2025) compares prospective OFB/HFB and commercial VFB systems sized at 5 kW/40 kWh. The study uses 1 kWh theoretical capacity (cradle-to-gate) and 1 kWh lifetime delivered electricity (cradle-to-use), excluding end-of-life. It describes then-current OFB/HFB TRL about 4 and a modeled industrial target near TRL9 around 2030–2035; these are scenario assumptions, not measured deployment or a reference year for every precursor. The source uses Brightway, ecoinvent3.9 cut-off and EF3.1. E22 design equations are confidential; the main article and printed tables were retrieved, while publisher ESI downloads returned 403/404 in this session. This exact node declares unit of inverter, 5kW. Preserve its precursor/component/service boundary and recorded supplier mappings; the source's whole-battery functional unit and performance are not automatically inherited by this node. Corrected salt counterions, tank ownership, converter/pump assumptions and finished installed-mass denominators are separate CLIC adaptations. | Architecture and rating The current reference is an adapted two-stage bidirectional converter rated in the model at 5 kW AC, separate from the historical 18 kg solar-inverter proxy. Eighteen 300 W DC module equivalents provide a nominal 5.4 kW architecture. Low-voltage ports are parallel; high-voltage ports form nine strings of two 400 V ports to match the assumed 800 V link. A full nominal 10 kW AC reference board is retained at 5 kW operation; physical switch counts are not halved. Voltage/current assumptions OFB uses 13 cells at 1 V; HFB uses 11 at 1.25 V, giving 13 V and 13.75 V. The TI DC guide specifies 200–400 V high-voltage, 9–13.5 V low-voltage and 300 W bidirectional operation. HFB is 1.85% above that low-voltage range; extension toward 14 V is a CLIC control assumption. At 5 kW total, each low-voltage port carries about 278 W and 21.37 A at 13 V. The retained 300 W/12 V = 25 A comparison is a nominal arithmetic check, distinct from the guide's stated 33 A low-voltage rating. The assumed 400 V three-phase AC current is 7.22 A rms. Isolation, common-mode control, flux, loop stability, current sharing, layout and thermal margins are unverified. Component and material ownership The DC counts are 126 TO-220 packages (72 high-voltage and 54 low-voltage), 72 dual drivers and 18 controllers; the AC stage adds 12 SiC switches, 12 isolated drivers and one controller. The TI 100 V CSD19536KCS package is a material analogue, not a voltage-compatible substitute for the 650 V IPP60R199CP; its use for the 60 V FDP device likewise does not validate die geometry. UCC27524A-family, TMS320F28035PNT, SiC and UCC21710 package references retain their manufacturer-analogue roles. Only the first assembly variant is used. The 42.368368 mg proprietary metal-hydroxide fraction per CSD package and the small controller proprietary fraction remain unresolved, with no invented composition. Retained budgets Bare PCB area is 18 × 0.025 + 0.10 = 0.55 m² at an assumed 3.08 kg/m². Per DC module, assumed magnetics are 0.08 kg transformer copper, 0.02 kg inductor copper and 0.12 kg ferrite. Their 1.8 kg copper is inside the existing 3.06 kg total, leaving 1.26 kg for AC filters, wiring and busbars. Aluminium 7.64 kg, steel 1.45 kg and PP 1.41 kg are retained mechanical budgets. Package and bare-board metals are assumed additional to those bulk budgets; ownership remains uncertain. The 0.412 kg electrolytic and 0.267 kg film-capacitor budgets already contain the small DC capacitors. The 0.01 kg each of resistor, diode and connector are allowances, not a complete recovered BOM. No extra complete mounted-board IC proxy is added. Manufacture and retirement The nominal finished ledger is 18.491259364830004 kg, paired with whole-device WEEE treatment once. Device helpers have no separate retirement purchase. Paperboard 2.91 kg and PE packaging 0.0184 kg have matching waste once. Unit assembly allowances remain 16.9 kWh electricity, 5.72 MJ gas heat and 0.361 MJ other heat. The source-model round-trip factors already include conversion and pumps, so no second operating-loss multiplier is added. Twenty-year periphery life is an adopted model assumption; the inverter life remains unvalidated, with 10–20-year sensitivity distinct from a second purchase. Winding fabrication, gate-pulse transformers, EMC, sensors, communications, cooling and proprietary fractions remain coverage limits. Additional architecture references Texas Instruments. TIDRHT0 bill of materials for TIDM-BIDIR-400-12, https://www.ti.com/tool/TIDM-BIDIR-400-12 . Texas Instruments. TIDA01606 AC reference schematic, https://www.ti.com/lit/df/tidrvs4g/tidrvs4g.pdf . |
|
| Version metadata | Publication / citation | Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G | Not set | |
| Version metadata | Publication DOI | 10.1039/D4EB00027G | Not set | |
| Version metadata | Plant lifetime | Not set | 20 | |
| Version metadata | Source type | scientific_journal | other | |
| Version metadata | Contributors, publications, projects and supporting evidence | Funding: 1. Project: Url: https://cordis.europa.eu/project/id/860403 Funding: 1. Project: Name: European Training Network in Innovative Polymers for Next-Generation Electrochemical Energy Storage Funding: 1. Project: Acronym: POLYSTORAGE Funding: 1. Project: Relation: source_study Funding: 1. Project: Grant identifier: 860403 Funding: 1. Organization: Ror: https://ror.org/019w4f821 Funding: 1. Organization: Url: https://european-union.europa.eu/ Funding: 1. Organization: Name: European Union Funding: 1. Award identifier: 860403 Funding: 2. Project: Url: https://doi.org/10.1039/d4eb00027g Funding: 2. Project: Name: Zhang et al. (2025) flow-battery source study: Arvidsson support Funding: 2. Project: Acronym: Not set Funding: 2. Project: Relation: source_study Funding: 2. Project: Grant identifier: P2019-90221 Funding: 2. Organization: Ror: https://ror.org/0359z7n90 Funding: 2. Organization: Url: https://www.energimyndigheten.se/ Funding: 2. Organization: Name: Swedish Energy Agency Funding: 2. Award identifier: P2019-90221 Evidence: 1. Origin: source_import Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: included_life_cycle_stages Evidence: 2. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage. Evidence: 2. Source location: name Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: editor_verification Evidence: 3. Target field: publications Evidence: 3. Qualification: Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers. Evidence: 3. Source location: DOI registration: title, publication dates and byline Evidence: 3. Source reference: https://api.crossref.org/works/10.1039%2FD4EB00027G Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Preserve paper publication years 2025/2018, not DOI submission year 2024 or archive creation year 2024. Historical HIU/KIT and SLU affiliations remain distinct from later repository affiliations or email domains. Article authors are not assigned as inventory contributors. HIPOLE polymer institute remains distinct from the GSI physics institute and has no verified ROR in this review. Evidence: 4. Source location: Original paper byline and historical affiliations; DOI deposits; source-study institutional identity records Evidence: 4. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 5. Origin: editor_verification Evidence: 5. Target field: methodology_notes Evidence: 5. Qualification: Source review: Zhang et al. (2025) compares prospective OFB/HFB and commercial VFB systems sized at 5 kW/40 kWh. The study uses 1 kWh theoretical capacity (cradle-to-gate) and 1 kWh lifetime delivered electricity (cradle-to-use), excluding end-of-life. It describes then-current OFB/HFB TRL about 4 and a modeled industrial target near TRL9 around 2030–2035; these are scenario assumptions, not measured deployment or a reference year for every precursor. The source uses Brightway, ecoinvent3.9 cut-off and EF3.1. E22 design equations are confidential; the main article and printed tables were retrieved, while publisher ESI downloads returned 403/404 in this session. This exact node declares unit of inverter, 5kW. Preserve its precursor/component/service boundary and recorded supplier mappings; the source's whole-battery functional unit and performance are not automatically inherited by this node. Corrected salt counterions, tank ownership, converter/pump assumptions and finished installed-mass denominators are separate CLIC adaptations. Evidence: 5. Source location: Main paper sections2.1–2.3, Tables1–5; ESI availability statement Evidence: 5. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 6. Origin: editor_verification Evidence: 6. Target field: methodology_notes Evidence: 6. Qualification: This superseded recipe remains distinct from its successor. Later CLIC engineering arithmetic does not certify or silently replace the earlier version's exchanges. Evidence: 6. Source location: Archived version status and source-specific comparison Evidence: 6. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 7. Origin: editor_verification Evidence: 7. Target field: funding Evidence: 7. Qualification: POLYSTORAGE860403 is source support acknowledged by Ramanujam/Michieletto/Schubert; Arvidsson acknowledges Swedish Energy Agency P2019-90221. Shan Zhang acknowledges SLU/STandUp support. E22 provides design insights, not an inferred grant. All links concern source_study, not CLIC funding or universal support of every author/provider. Evidence: 7. Source location: Source acknowledgments; CORDIS860403 and verified funder identities Evidence: 7. Source reference: https://doi.org/10.1039/d4eb00027g Projects: 1. Url: https://cordis.europa.eu/project/id/860403 Projects: 1. Name: European Training Network in Innovative Polymers for Next-Generation Electrochemical Energy Storage Projects: 1. Acronym: POLYSTORAGE Projects: 1. Relation: source_study Projects: 1. Grant identifier: 860403 Projects: 2. Url: https://doi.org/10.1039/d4eb00027g Projects: 2. Name: Zhang et al. (2025) flow-battery source study: Arvidsson support Projects: 2. Acronym: Not set Projects: 2. Relation: source_study Projects: 2. Grant identifier: P2019-90221 Publications: 1. Doi: 10.1039/d4eb00027g Publications: 1. Url: https://doi.org/10.1039/D4EB00027G Publications: 1. Title: Prospective life cycle assessment of organic redox flow batteries Publications: 1. Scientific authors: 1. Name: Shan Zhang Publications: 1. Scientific authors: 1. Orcid: 0000-0002-7666-1222 Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02yy8x990 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.slu.se/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Department of Energy and Technology, Swedish University of Agricultural Sciences, P.O Box 7032, SE-75007 Uppsala, Sweden Publications: 1. Scientific authors: 2. Name: Athul Seshadri Ramanujam Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/002tzev63 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://energia.imdea.org/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Electrochemical Processes Unit, IMDEA Energy, Avda. Ramón de la Sagra 3, 28935 Móstoles, Spain Publications: 1. Scientific authors: 2. Affiliations: 2. Ror: Not set Publications: 1. Scientific authors: 2. Affiliations: 2. Url: Not set Publications: 1. Scientific authors: 2. Affiliations: 2. Name: Energy Storage Solutions E22, Avenida de Barajas 32, Parque Empresarial Omega Edificio A, 28108 Alcobendas, Spain Publications: 1. Scientific authors: 2. Affiliations: 3. Ror: https://ror.org/000xsnr85 Publications: 1. Scientific authors: 2. Affiliations: 3. Url: https://www.ehu.eus/ Publications: 1. Scientific authors: 2. Affiliations: 3. Name: Department of Applied Chemistry, Faculty of Chemistry, University of the Basque Country UPV/EHU, Avda. Manuel de Lardizabal 3, 20018 Donostia-San Sebastián, Spain Publications: 1. Scientific authors: 3. Name: Rickard Arvidsson Publications: 1. Scientific authors: 3. Orcid: 0000-0002-9258-0641 Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/040wg7k59 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.chalmers.se/ Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Division of Environmental Systems Analysis, Department of Technology Management and Economics, Chalmers University of Technology, Gothenburg 41296, Sweden Publications: 1. Scientific authors: 4. Name: Alessandro Michieletto Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Laboratory of Organic and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Humboldtstraße 10, 07743 Jena, Germany Publications: 1. Scientific authors: 4. Affiliations: 2. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 4. Affiliations: 2. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 4. Affiliations: 2. Name: Center for Energy and Environmental Chemistry Jena (CEEC Jena), Friedrich Schiller University Jena, Philosophenweg 7a, Jena 07743, Germany Publications: 1. Scientific authors: 5. Name: Ulrich S. Schubert Publications: 1. Scientific authors: 5. Orcid: 0000-0003-4978-4670 Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Laboratory of Organic and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Humboldtstraße 10, 07743 Jena, Germany Publications: 1. Scientific authors: 5. Affiliations: 2. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 5. Affiliations: 2. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 5. Affiliations: 2. Name: Center for Energy and Environmental Chemistry Jena (CEEC Jena), Friedrich Schiller University Jena, Philosophenweg 7a, Jena 07743, Germany Publications: 1. Scientific authors: 5. Affiliations: 3. Ror: Not set Publications: 1. Scientific authors: 5. Affiliations: 3. Url: https://www.hipole-jena.de/ Publications: 1. Scientific authors: 5. Affiliations: 3. Name: Helmholtz Institute for Polymers in Energy Applications Jena (HIPOLE Jena), Lessingstrasse 12-14, Jena 07743, Germany Publications: 1. Citation: Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2025 |
Funding: 1. Project: Url: https://cordis.europa.eu/project/id/860403 Funding: 1. Project: Name: European Training Network in Innovative Polymers for Next-Generation Electrochemical Energy Storage Funding: 1. Project: Acronym: POLYSTORAGE Funding: 1. Project: Relation: source_study Funding: 1. Project: Grant identifier: 860403 Funding: 1. Organization: Ror: https://ror.org/019w4f821 Funding: 1. Organization: Url: https://european-union.europa.eu/ Funding: 1. Organization: Name: European Union Funding: 1. Award identifier: 860403 Funding: 2. Project: Url: https://doi.org/10.1039/d4eb00027g Funding: 2. Project: Name: Zhang et al. (2025) flow-battery source study: Arvidsson support Funding: 2. Project: Acronym: Not set Funding: 2. Project: Relation: source_study Funding: 2. Project: Grant identifier: P2019-90221 Funding: 2. Organization: Ror: https://ror.org/0359z7n90 Funding: 2. Organization: Url: https://www.energimyndigheten.se/ Funding: 2. Organization: Name: Swedish Energy Agency Funding: 2. Award identifier: P2019-90221 Evidence: 1. Origin: source_import Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: included_life_cycle_stages Evidence: 2. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage. Evidence: 2. Source location: name Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: editor_verification Evidence: 3. Target field: publications Evidence: 3. Qualification: Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers. Evidence: 3. Source location: DOI registration: title, publication dates and byline Evidence: 3. Source reference: https://api.crossref.org/works/10.1039%2FD4EB00027G Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Preserve paper publication years 2025/2018, not DOI submission year 2024 or archive creation year 2024. Historical HIU/KIT and SLU affiliations remain distinct from later repository affiliations or email domains. Article authors are not assigned as inventory contributors. HIPOLE polymer institute remains distinct from the GSI physics institute and has no verified ROR in this review. Evidence: 4. Source location: Original paper byline and historical affiliations; DOI deposits; source-study institutional identity records Evidence: 4. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 5. Origin: editor_verification Evidence: 5. Target field: methodology_notes Evidence: 5. Qualification: Source review: Zhang et al. (2025) compares prospective OFB/HFB and commercial VFB systems sized at 5 kW/40 kWh. The study uses 1 kWh theoretical capacity (cradle-to-gate) and 1 kWh lifetime delivered electricity (cradle-to-use), excluding end-of-life. It describes then-current OFB/HFB TRL about 4 and a modeled industrial target near TRL9 around 2030–2035; these are scenario assumptions, not measured deployment or a reference year for every precursor. The source uses Brightway, ecoinvent3.9 cut-off and EF3.1. E22 design equations are confidential; the main article and printed tables were retrieved, while publisher ESI downloads returned 403/404 in this session. This exact node declares unit of inverter, 5kW. Preserve its precursor/component/service boundary and recorded supplier mappings; the source's whole-battery functional unit and performance are not automatically inherited by this node. Corrected salt counterions, tank ownership, converter/pump assumptions and finished installed-mass denominators are separate CLIC adaptations. Evidence: 5. Source location: Main paper sections2.1–2.3, Tables1–5; ESI availability statement Evidence: 5. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 6. Origin: editor_verification Evidence: 6. Target field: funding Evidence: 6. Qualification: POLYSTORAGE860403 is source support acknowledged by Ramanujam/Michieletto/Schubert; Arvidsson acknowledges Swedish Energy Agency P2019-90221. Shan Zhang acknowledges SLU/STandUp support. E22 provides design insights, not an inferred grant. All links concern source_study, not CLIC funding or universal support of every author/provider. Evidence: 6. Source location: Source acknowledgments; CORDIS860403 and verified funder identities Evidence: 6. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 7. Origin: editor_verification Evidence: 7. Target field: methodology_notes Evidence: 7. Qualification: Current exact compiler comparison is partial source evidence. Historical quantities and configurations remain separate: seven later helpers have no exact block in the pinned older workbook. Original RSC ESI was not recovered through the recorded403/404 attempts; these are access/path limitations, not proof that no supplement exists. The paper's5kW/40kWh model, hypothetical industrial performance, confidential E22 design equations and cradle-to-gate/use boundaries do not define a measured chemical/device inventory for every node. Evidence: 7. Source location: Original source model, pinned current/historical compiler comparison and scoped limitations Evidence: 7. Source reference: https://doi.org/10.1039/d4eb00027g Evidence: 8. Origin: editor_verification Evidence: 8. Target field: technology_description Evidence: 8. Qualification: Technical-characterisation review TC-1370. Design capacity: 5.000000. Basis: No new value established on this exact chemical/component/market reference; existing power/storage context retained with its explicit boundary. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 8. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 8. Source reference: https://zenodo.org/records/23935622 Evidence: 9. Origin: editor_verification Evidence: 9. Target field: technology_description Evidence: 9. Qualification: Technical-characterisation review TC-1370. Design capacity unit: kW. Basis: No new value established on this exact chemical/component/market reference; existing power/storage context retained with its explicit boundary. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 9. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 9. Source reference: https://zenodo.org/records/23935622 Evidence: 10. Origin: editor_verification Evidence: 10. Target field: technology_description Evidence: 10. Qualification: Technical-characterisation review TC-1370. Capacity factor (%): Unspecified. Basis: No new value established on this exact chemical/component/market reference; existing power/storage context retained with its explicit boundary. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 10. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 10. Source reference: https://zenodo.org/records/23935622 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: technology_description Evidence: 11. Qualification: Technical-characterisation review TC-1370. Annual production volume: Unspecified. Basis: No new value established on this exact chemical/component/market reference; existing power/storage context retained with its explicit boundary. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 11. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 11. Source reference: https://zenodo.org/records/23935622 Evidence: 12. Origin: editor_verification Evidence: 12. Target field: technology_description Evidence: 12. Qualification: Technical-characterisation review TC-1370. Annual production volume unit: Unspecified. Basis: No new value established on this exact chemical/component/market reference; existing power/storage context retained with its explicit boundary. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 12. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 12. Source reference: https://zenodo.org/records/23935622 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: technology_description Evidence: 13. Qualification: Technical-characterisation review TC-1370. Annual production volume year: Unspecified. Basis: No new value established on this exact chemical/component/market reference; existing power/storage context retained with its explicit boundary. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 13. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 13. Source reference: https://zenodo.org/records/23935622 Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-1370. Plant or represented-asset lifetime (years): 20. Basis: Source-model 20-year equipment duration and archive-allocated operating output. These are assumptions/derived averages, not measured survival or annual survey data. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 14. Source reference: https://zenodo.org/records/23935622 Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-1370. Commercial maturity stage: Unspecified. Basis: Clear exact numerical readiness for this adapted model. Clear pilot maturity because the independently assembled architecture is not established as a tested pilot. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 15. Source reference: https://zenodo.org/records/23935622 Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-1370. Technology readiness level: Unspecified. Basis: Clear exact numerical readiness for this adapted model. Clear pilot maturity because the independently assembled architecture is not established as a tested pilot. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 16. Source reference: https://zenodo.org/records/23935622 Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-1370. Technological representativeness: 5. Basis: Curator technology/geography/time 5/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 17. Source reference: https://zenodo.org/records/23935622 Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-1370. Geographical representativeness: 3. Basis: Curator technology/geography/time 5/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 18. Source reference: https://zenodo.org/records/23935622 Evidence: 19. Origin: editor_verification Evidence: 19. Target field: technology_description Evidence: 19. Qualification: Technical-characterisation review TC-1370. Temporal representativeness: 4. Basis: Curator technology/geography/time 5/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 19. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 19. Source reference: https://zenodo.org/records/23935622 Projects: 1. Url: https://cordis.europa.eu/project/id/860403 Projects: 1. Name: European Training Network in Innovative Polymers for Next-Generation Electrochemical Energy Storage Projects: 1. Acronym: POLYSTORAGE Projects: 1. Relation: source_study Projects: 1. Grant identifier: 860403 Projects: 2. Url: https://doi.org/10.1039/d4eb00027g Projects: 2. Name: Zhang et al. (2025) flow-battery source study: Arvidsson support Projects: 2. Acronym: Not set Projects: 2. Relation: source_study Projects: 2. Grant identifier: P2019-90221 Publications: 1. Doi: 10.1039/d4eb00027g Publications: 1. Url: https://doi.org/10.1039/D4EB00027G Publications: 1. Title: Prospective life cycle assessment of organic redox flow batteries Publications: 1. Scientific authors: 1. Name: Shan Zhang Publications: 1. Scientific authors: 1. Orcid: 0000-0002-7666-1222 Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02yy8x990 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.slu.se/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Department of Energy and Technology, Swedish University of Agricultural Sciences, P.O Box 7032, SE-75007 Uppsala, Sweden Publications: 1. Scientific authors: 2. Name: Athul Seshadri Ramanujam Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/002tzev63 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://energia.imdea.org/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Electrochemical Processes Unit, IMDEA Energy, Avda. Ramón de la Sagra 3, 28935 Móstoles, Spain Publications: 1. Scientific authors: 2. Affiliations: 2. Ror: Not set Publications: 1. Scientific authors: 2. Affiliations: 2. Url: Not set Publications: 1. Scientific authors: 2. Affiliations: 2. Name: Energy Storage Solutions E22, Avenida de Barajas 32, Parque Empresarial Omega Edificio A, 28108 Alcobendas, Spain Publications: 1. Scientific authors: 2. Affiliations: 3. Ror: https://ror.org/000xsnr85 Publications: 1. Scientific authors: 2. Affiliations: 3. Url: https://www.ehu.eus/ Publications: 1. Scientific authors: 2. Affiliations: 3. Name: Department of Applied Chemistry, Faculty of Chemistry, University of the Basque Country UPV/EHU, Avda. Manuel de Lardizabal 3, 20018 Donostia-San Sebastián, Spain Publications: 1. Scientific authors: 3. Name: Rickard Arvidsson Publications: 1. Scientific authors: 3. Orcid: 0000-0002-9258-0641 Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/040wg7k59 Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.chalmers.se/ Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Division of Environmental Systems Analysis, Department of Technology Management and Economics, Chalmers University of Technology, Gothenburg 41296, Sweden Publications: 1. Scientific authors: 4. Name: Alessandro Michieletto Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Laboratory of Organic and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Humboldtstraße 10, 07743 Jena, Germany Publications: 1. Scientific authors: 4. Affiliations: 2. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 4. Affiliations: 2. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 4. Affiliations: 2. Name: Center for Energy and Environmental Chemistry Jena (CEEC Jena), Friedrich Schiller University Jena, Philosophenweg 7a, Jena 07743, Germany Publications: 1. Scientific authors: 5. Name: Ulrich S. Schubert Publications: 1. Scientific authors: 5. Orcid: 0000-0003-4978-4670 Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Laboratory of Organic and Macromolecular Chemistry (IOMC), Friedrich Schiller University Jena, Humboldtstraße 10, 07743 Jena, Germany Publications: 1. Scientific authors: 5. Affiliations: 2. Ror: https://ror.org/05qpz1x62 Publications: 1. Scientific authors: 5. Affiliations: 2. Url: https://www.uni-jena.de/ Publications: 1. Scientific authors: 5. Affiliations: 2. Name: Center for Energy and Environmental Chemistry Jena (CEEC Jena), Friedrich Schiller University Jena, Philosophenweg 7a, Jena 07743, Germany Publications: 1. Scientific authors: 5. Affiliations: 3. Ror: Not set Publications: 1. Scientific authors: 5. Affiliations: 3. Url: https://www.hipole-jena.de/ Publications: 1. Scientific authors: 5. Affiliations: 3. Name: Helmholtz Institute for Polymers in Energy Applications Jena (HIPOLE Jena), Lessingstrasse 12-14, Jena 07743, Germany Publications: 1. Citation: Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G Publications: 1. Relation: supporting_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2025 Publications: 2. Doi: Not set Publications: 2. Url: https://www.ti.com/lit/ug/tiduai7/tiduai7.pdf Publications: 2. Title: Bidirectional DC-DC Converter Publications: 2. Citation: Texas Instruments (2015). Bidirectional DC-DC Converter. Design guide TIDUAI7, September 2015. https://www.ti.com/lit/ug/tiduai7/tiduai7.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: industry_documentation Publications: 2. Publication year: 2015 |
|
| Version metadata | Technological representativeness | 4 | 5 | |
| Version metadata | Technology readiness level | 5 | Not set | |
| Version metadata | Description | total weight: 18 kg. Data is from report: Life cycle assessment of low power solar inverters (2.5 to 20 kW) authors: Laura Tschümperlin, Philippe Stolz, Rolf Frischknecht. Data directly collected from producer. The original inventory is presented in: "Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G" Source review: Zhang et al. (2025) compares prospective OFB/HFB and commercial VFB systems sized at 5 kW/40 kWh. The study uses 1 kWh theoretical capacity (cradle-to-gate) and 1 kWh lifetime delivered electricity (cradle-to-use), excluding end-of-life. It describes then-current OFB/HFB TRL about 4 and a modeled industrial target near TRL9 around 2030–2035; these are scenario assumptions, not measured deployment or a reference year for every precursor. The source uses Brightway, ecoinvent3.9 cut-off and EF3.1. E22 design equations are confidential; the main article and printed tables were retrieved, while publisher ESI downloads returned 403/404 in this session. This exact node declares unit of inverter, 5kW. Preserve its precursor/component/service boundary and recorded supplier mappings; the source's whole-battery functional unit and performance are not automatically inherited by this node. Corrected salt counterions, tank ownership, converter/pump assumptions and finished installed-mass denominators are separate CLIC adaptations. |
Adapted bidirectional redox-flow battery converter, with declared output 1 unit. | Describe the actual reference flow, process boundary, engineering assumptions and source limitations in reader-facing language. Remove operational review/release instructions and distinguish capacity/component services from operating-energy inputs; the inventory content and declared terms are preserved. |
| Version metadata | Intended application | Not set | Reuse with the matching chemistry, process boundary, declared batch/reference output and current model configuration; retain the distinct source scenario and CLIC engineering assumptions. | Apply reviewed discovery metadata and change explanations from the curated release. |
| Version metadata | System boundary | Not set | The declared 1 unit output and its recorded suppliers/services. Chemical batches, initial equipment, storage energy, lifetime electricity and explicit component retirement retain separate denominators. | |
| Version metadata | Technology description | Not set | Independent two-stage conversion reference for nominal 5 kW AC operation, combining eighteen DC module equivalents with a full AC reference board. It replaces the historical generic solar-inverter representation. | |
| Version metadata | Limitations on use | Not set | This architecture and material budget are engineering assumptions, not a qualified TI system or a literal converter recipe published by Zhang et al. Control extension, series/parallel isolation, package analogues and incomplete factory/BOM coverage require separate hardware and manufacturing evidence. Source battery efficiency already includes conversion; no new operating loss or automatic life doubling is implied. | |
| Version metadata | Name | inverter production, 5kW | inverter production, 5kw | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
| Version metadata | Source | Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G | Supporting sources: Zhang, S., Ramanujam, A. S., Arvidsson, R., Michieletto, A., & Schubert, U. S. (2025). Prospective life cycle assessment of organic redox flow batteries. EES Batteries. doi: https://doi.org/10.1039/D4EB00027G Texas Instruments (2015). Bidirectional DC-DC Converter. Design guide TIDUAI7, September 2015. https://www.ti.com/lit/ug/tiduai7/tiduai7.pdf |
The source attribution now identifies the publication or inventory underlying this reference (https://doi.org/10.1039/D4EB00027G) and distinguishes its evidence from the model’s engineering assumptions. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content