Description
Production of magnetic stirrer. The reference flow is one unit of magnetic stirrer. It is a supporting equipment or consumable inventory for the laboratory waste-RAM recovery route.
Waste
Reference product magnetic stirrer GLO
Stable dataset identity
magnetic-stirrer-production
1.0.0Published inventory
Process description and catalog context. View scientific metadata
Production of magnetic stirrer. The reference flow is one unit of magnetic stirrer. It is a supporting equipment or consumable inventory for the laboratory waste-RAM recovery route.
Classification, keywords, bookmarks and download counts.
Classification path: Waste
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
https://doi.org/10.1016/j.jclepro.2025.147016; https://doi.org/10.5281/zenodo.17348137; LCI_equipment!A96; SHA-256 cda3a9b590afe2e570908048c1e2999f1a9ba098f0045f6312c7074344674c24
Inventory changes relative to source: Modified inventory
The published ecoinvent 3.8 APOS background is replaced by ecoinvent 3.12 cut-off. The compilation also makes the documented laboratory correction and alternative allocation views explicit; it is not a reproduction of the original APOS model.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-16 10:57 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
magnetic stirrer production
GLO
|
magnetic stirrer
|
1
|
unit | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
reinforcing steel production
RoW
|
reinforcing steel
|
1.12
|
kilogram |
0.00454108
mol H+-Eq / unit
2.8% of total
1.63918
kg CO2-Eq / unit
23.5% of total
4.3244
CTUe / unit
6.0% of total
0.000632438
kg P-Eq / unit
1.2% of total
0.00108838
kg N-Eq / unit
9.0% of total
0.0114252
mol N-Eq / unit
8.6% of total
4.8557e-09
CTUh / unit
7.6% of total
4.9628e-08
CTUh / unit
1.9% of total
0.394372
kBq U235-Eq / unit
21.1% of total
4.68134
dimensionless / unit
8.5% of total
1.9686e-08
kg CFC-11-Eq / unit
12.8% of total
1.0074e-07
disease incidence / unit
17.1% of total
0.0049536
kg NMVOC-Eq / unit
11.7% of total
16.2747
MJ, net calorific value / unit
12.3% of total
1.0932e-05
kg Sb-Eq / unit
1.7% of total
0.360738
m3 world Eq deprived / unit
2.4% of total
BAFU:2025
|
|
|
polyethylene production, high density, granulate
RoW
|
polyethylene, high density, granulate
|
0.98
|
kilogram |
0.00528823
mol H+-Eq / unit
3.3% of total
2.2246
kg CO2-Eq / unit
31.9% of total
13.2537
CTUe / unit
18.5% of total
0.000123763
kg P-Eq / unit
0.2% of total
0.00117833
kg N-Eq / unit
9.7% of total
0.0129079
mol N-Eq / unit
9.7% of total
3.1856e-10
CTUh / unit
0.5% of total
8.4252e-09
CTUh / unit
0.3% of total
0.0799967
kBq U235-Eq / unit
4.3% of total
0.920885
dimensionless / unit
1.7% of total
6.2409e-08
kg CFC-11-Eq / unit
40.5% of total
6.6532e-08
disease incidence / unit
11.3% of total
0.00564122
kg NMVOC-Eq / unit
13.3% of total
68.8158
MJ, net calorific value / unit
51.9% of total
3.3618e-06
kg Sb-Eq / unit
0.5% of total
12.9161
m3 world Eq deprived / unit
84.7% of total
BAFU:2025
|
|
|
steel production, electric, chromium steel 18/8
RoW
|
steel, chromium steel 18/8
|
0.42
|
kilogram |
0.0086494
mol H+-Eq / unit
5.3% of total
1.46073
kg CO2-Eq / unit
20.9% of total
5.61015
CTUe / unit
7.8% of total
0.000564163
kg P-Eq / unit
1.1% of total
0.00146908
kg N-Eq / unit
12.1% of total
0.0156508
mol N-Eq / unit
11.7% of total
3.0754e-08
CTUh / unit
48.4% of total
1.6117e-07
CTUh / unit
6.1% of total
0.364945
kBq U235-Eq / unit
19.5% of total
7.27546
dimensionless / unit
13.2% of total
2.1565e-08
kg CFC-11-Eq / unit
14.0% of total
1.1735e-07
disease incidence / unit
20.0% of total
0.00497459
kg NMVOC-Eq / unit
11.8% of total
19.3482
MJ, net calorific value / unit
14.6% of total
5.0951e-05
kg Sb-Eq / unit
7.9% of total
0.392095
m3 world Eq deprived / unit
2.6% of total
BAFU:2025
|
|
|
smelting of copper concentrate, sulfide ore
RoW
|
copper, anode
|
0.28
|
kilogram |
0.139624
mol H+-Eq / unit
86.2% of total
0.787505
kg CO2-Eq / unit
11.3% of total
44.4427
CTUe / unit
61.9% of total
0.0493094
kg P-Eq / unit
95.4% of total
0.00784263
kg N-Eq / unit
64.8% of total
0.0887432
mol N-Eq / unit
66.5% of total
2.5164e-08
CTUh / unit
39.6% of total
2.3777e-06
CTUh / unit
90.5% of total
0.230568
kBq U235-Eq / unit
12.3% of total
19.3939
dimensionless / unit
35.3% of total
1.8657e-08
kg CFC-11-Eq / unit
12.1% of total
2.6376e-07
disease incidence / unit
44.9% of total
0.0244447
kg NMVOC-Eq / unit
57.8% of total
10.566
MJ, net calorific value / unit
8.0% of total
0.000564307
kg Sb-Eq / unit
87.6% of total
0.843916
m3 world Eq deprived / unit
5.5% of total
BAFU:2025
|
|
|
hot rolling, steel
RoW
|
hot rolling, steel
|
1.12
|
kilogram |
0.000254454
mol H+-Eq / unit
0.2% of total
0.186572
kg CO2-Eq / unit
2.7% of total
0.839244
CTUe / unit
1.2% of total
3.1350e-05
kg P-Eq / unit
0.1% of total
9.4256e-05
kg N-Eq / unit
0.8% of total
0.000910266
mol N-Eq / unit
0.7% of total
2.2685e-10
CTUh / unit
0.4% of total
3.3914e-09
CTUh / unit
0.1% of total
0.136472
kBq U235-Eq / unit
7.3% of total
0.56351
dimensionless / unit
1.0% of total
7.1170e-09
kg CFC-11-Eq / unit
4.6% of total
8.7657e-09
disease incidence / unit
1.5% of total
0.000772549
kg NMVOC-Eq / unit
1.8% of total
4.07235
MJ, net calorific value / unit
3.1% of total
1.7693e-07
kg Sb-Eq / unit
0.0% of total
0.159042
m3 world Eq deprived / unit
1.0% of total
BAFU:2025
|
|
|
blow moulding
RoW
|
blow moulding
|
0.98
|
kilogram |
0.00229484
mol H+-Eq / unit
1.4% of total
0.632491
kg CO2-Eq / unit
9.1% of total
2.23635
CTUe / unit
3.1% of total
0.000437796
kg P-Eq / unit
0.8% of total
0.000500337
kg N-Eq / unit
4.1% of total
0.00448278
mol N-Eq / unit
3.4% of total
1.9202e-09
CTUh / unit
3.0% of total
5.1050e-09
CTUh / unit
0.2% of total
0.639903
kBq U235-Eq / unit
34.2% of total
22.484
dimensionless / unit
40.9% of total
2.0473e-08
kg CFC-11-Eq / unit
13.3% of total
2.7595e-08
disease incidence / unit
4.7% of total
0.00159085
kg NMVOC-Eq / unit
3.8% of total
14.0239
MJ, net calorific value / unit
10.6% of total
1.1600e-06
kg Sb-Eq / unit
0.2% of total
0.76784
m3 world Eq deprived / unit
5.0% of total
BAFU:2025
|
|
|
wire drawing, steel
RoW
|
wire drawing, steel
|
0.42
|
kilogram |
0.00026691
mol H+-Eq / unit
0.2% of total
0.164502
kg CO2-Eq / unit
2.4% of total
0.960312
CTUe / unit
1.3% of total
4.6154e-05
kg P-Eq / unit
0.1% of total
5.9894e-05
kg N-Eq / unit
0.5% of total
0.000584723
mol N-Eq / unit
0.4% of total
1.4740e-10
CTUh / unit
0.2% of total
2.5583e-09
CTUh / unit
0.1% of total
0.0322901
kBq U235-Eq / unit
1.7% of total
0.436534
dimensionless / unit
0.8% of total
8.2152e-09
kg CFC-11-Eq / unit
5.3% of total
4.3517e-09
disease incidence / unit
0.7% of total
0.000259871
kg NMVOC-Eq / unit
0.6% of total
1.13471
MJ, net calorific value / unit
0.9% of total
1.1846e-06
kg Sb-Eq / unit
0.2% of total
0.0233697
m3 world Eq deprived / unit
0.2% of total
BAFU:2025
|
|
|
wire drawing, copper
RoW
|
wire drawing, copper
|
0.28
|
kilogram |
0.00190855
mol H+-Eq / unit
1.2% of total
0.104555
kg CO2-Eq / unit
1.5% of total
0.756028
CTUe / unit
1.1% of total
0.000613921
kg P-Eq / unit
1.2% of total
0.000159795
kg N-Eq / unit
1.3% of total
0.00176405
mol N-Eq / unit
1.3% of total
2.9420e-10
CTUh / unit
0.5% of total
2.2222e-08
CTUh / unit
0.8% of total
0.0528523
kBq U235-Eq / unit
2.8% of total
0.644445
dimensionless / unit
1.2% of total
2.6159e-09
kg CFC-11-Eq / unit
1.7% of total
5.1036e-09
disease incidence / unit
0.9% of total
0.000771092
kg NMVOC-Eq / unit
1.8% of total
1.78409
MJ, net calorific value / unit
1.3% of total
1.2754e-05
kg Sb-Eq / unit
2.0% of total
0.044636
m3 world Eq deprived / unit
0.3% of total
BAFU:2025
|
|
|
transport, freight, lorry, 16-32 metric ton, diesel, EURO 6
RoW
|
transport, freight, lorry, 16-32 metric ton, diesel, EURO 6
|
0.28
|
ton kilometer |
0.000415971
mol H+-Eq / unit
0.3% of total
0.0782898
kg CO2-Eq / unit
1.1% of total
0.191179
CTUe / unit
0.3% of total
5.6988e-06
kg P-Eq / unit
0.0% of total
0.000182856
kg N-Eq / unit
1.5% of total
0.00198391
mol N-Eq / unit
1.5% of total
2.1120e-11
CTUh / unit
0.0% of total
4.8063e-10
CTUh / unit
0.0% of total
0.00898905
kBq U235-Eq / unit
0.5% of total
0.339073
dimensionless / unit
0.6% of total
4.1340e-09
kg CFC-11-Eq / unit
2.7% of total
2.0832e-09
disease incidence / unit
0.4% of total
0.00065023
kg NMVOC-Eq / unit
1.5% of total
1.13081
MJ, net calorific value / unit
0.9% of total
1.5107e-07
kg Sb-Eq / unit
0.0% of total
0.0706992
m3 world Eq deprived / unit
0.5% of total
BAFU:2025
|
|
|
market for used printed wiring boards
GLO
|
used printed wiring boards
|
-2.8
|
kilogram |
-0.00121509
mol H+-Eq / unit
-0.7% of total
-0.295674
kg CO2-Eq / unit
-4.2% of total
-0.843714
CTUe / unit
-1.2% of total
-5.2594e-05
kg P-Eq / unit
-0.1% of total
-0.000475798
kg N-Eq / unit
-3.9% of total
-0.00490861
mol N-Eq / unit
-3.7% of total
-1.2212e-10
CTUh / unit
-0.2% of total
-2.2912e-09
CTUh / unit
-0.1% of total
-0.0712267
kBq U235-Eq / unit
-3.8% of total
-1.80453
dimensionless / unit
-3.3% of total
-1.0609e-08
kg CFC-11-Eq / unit
-6.9% of total
-8.8181e-09
disease incidence / unit
-1.5% of total
-0.00174697
kg NMVOC-Eq / unit
-4.1% of total
-4.54355
MJ, net calorific value / unit
-3.4% of total
-6.6386e-07
kg Sb-Eq / unit
-0.1% of total
-0.326857
m3 world Eq deprived / unit
-2.1% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
6 CLIC nodes and 10 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Choose software and background database settings once you open the Basket page.
| File | Downloads | Action |
|---|---|---|
| ecoinvent_3_12_cutoff.xlsx Primary | 0 | Log in to download |
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.0 | 2026-11-16 | Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens already include the source 0.769 internal treatment allocation: do not repeat it. Background is 3.12 cut-off, not the source APOS system. Deterministic inventory; no probability distributions added. | Current view |
Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens already include the source 0.769 internal treatment allocation: do not repeat it. Background is 3.12 cut-off, not the source APOS system. Deterministic inventory; no probability distributions added.
Publication route
A curator validated the batch manifest and an editor authorized publication. This route does not imply that CLIC's current structured community-review checklist was completed.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content