Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
- Source publication year
- Not specified
- Inventory reference year
- Not specified
- Foreground modelling approach
- Not specified
- Allocated product inventory
- Not specified
- Allocation or multifunctionality treatment
- Not specified
- Methodology notes
- Source basis
ESU's 2021 extraction inventories target the 2019 production update while retaining older process/infrastructure data. Later 2025 reports use a separate 2023 model basis. The May 2021 external validation covers its specifically listed versions and does not certify every later file or CLIC adaptation.
Regional and temporal context
Source geography: Global average.
Data vintage: Time of estimation.
Production/throughput context: Not known.
Data basis: Literature.
Extrapolation: From single data to global situation.
Source applicability interval: 2000–2020; it is not a uniform measurement period.
Uncertainty
The native source process has 7 exchanges labelled lognormal. No source uncertainty adjustment does not mean absence of exchange uncertainty. Export standardDeviation95 conversion and the importer convention are distinct from scientific validation of distributions and correlations. - System boundary
- Recorded emissions from venting under the declared gas reference. Other production, capture, treatment and combustion stages remain separately owned.
- Technology description
- Global venting model extrapolated from individual data. It is a direct-emission reference, not a saleable gas supply or an independently characterized field release.
- Intended application
- Reuse of this exact allocated production, infrastructure or emissions reference within the documented historical oil/gas model and its declared physical unit.
- Use limitations
- Mixed vintages, generic geographic transfers, supplier/biosphere adaptations and completeness of separately owned stages remain qualified. Average composition, global extrapolation, gas reference conditions and separately owned pollutant/utility burdens remain qualified.
- Data origins
- Literature, Engineering estimate
Other fields not yet completed (6)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type, Included life cycle stages
Inventory contributions (1)
- Name
- ESU-services Ltd.
- Kind
- Organization
- Roles
- Data provider
- Ror
- https://ror.org/024s10v78
Publications (1)
- Citation
- Christoph Meili; Niels Jungbluth; Maresa Bussa (2021). Life cycle inventories of crude oil and natural gas extraction. ESU-services Ltd., Schaffhausen. https://doi.org/10.13140/rg.2.2.29142.78409
- Title
- Life cycle inventories of crude oil and natural gas extraction
- Doi
- 10.13140/rg.2.2.29142.78409
- Url
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source type
- Technical report
- Publication year
- 2021
- Relation
- Supporting source
- Authors
- Christoph Meili; Niels Jungbluth; Maresa Bussa
Projects (1)
- Name
- Update of life cycle inventory data for natural gas and crude oil supply to Switzerland and Europe with the reference year 2019
- Url
- https://esu-services.ch/fileadmin/download/publicLCI/ifeu-2021-validation-statement-LCIoilgas.pdf
- Relation
- Source study
Funding (2)
- Organization
- Federal Office for the Environment (FOEN) · https://ror.org/04t48sm91
- Project
- Update of life cycle inventory data for natural gas and crude oil supply to Switzerland and Europe with the reference year 2019
- Organization
- Verband der Schweizerischen Gasindustrie (VSG)
- Project
- Update of life cycle inventory data for natural gas and crude oil supply to Switzerland and Europe with the reference year 2019
Evidence and qualifications (30)
- Target field
- publications
- Origin
- Source import
- Source reference
- Existing published CLIC inventory documentation
- Source location
- source
- Qualification
- Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
- Target field
- publications
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source location
- Printed p.1, Introduction
- Qualification
- Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
- Target field
- publications
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source location
- Imprint, Citation/Financing/Contractor
- Qualification
- Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
- Target field
- publications
- Origin
- Source import
- Source reference
- Existing published CLIC inventory documentation
- Source location
- inventory_snapshot/filename
- Qualification
- Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
- Target field
- data_origins
- Origin
- Source import
- Source reference
- Existing published CLIC inventory documentation
- Source location
- description
- Qualification
- Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
- Target field
- projects
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source location
- Imprint, Citation/Financing/Contractor
- Qualification
- Original ESU source-study update; not CLIC curation or a new funder claim.
- Target field
- projects
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source location
- Printed p.1, Introduction
- Qualification
- Original ESU source-study update; not CLIC curation or a new funder claim.
- Target field
- projects
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/bussa-2021-LCI%20for%20the%20gas%20distribution.pdf
- Source location
- Printed p.1, Introduction
- Qualification
- Original ESU source-study update; not CLIC curation or a new funder claim.
- Target field
- projects
- Origin
- Source import
- Source reference
- Existing published CLIC inventory documentation
- Source location
- source
- Qualification
- Original ESU source-study update; not CLIC curation or a new funder claim.
- Target field
- projects
- Origin
- Source import
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/ifeu-2021-validation-statement-LCIoilgas.pdf
- Source location
- Official source-study/programme identity
- Qualification
- Verified source-study identity; matching project URI and declarations permit consistent catalogue filtering.
- Target field
- funding
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source location
- Imprint, Citation/Financing/Contractor
- Qualification
- Explicit source-study Financing statement; no award number invented.
- Target field
- funding
- Origin
- Source import
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/ifeu-2021-validation-statement-LCIoilgas.pdf
- Source location
- Official source-study/programme identity
- Qualification
- Verified source-study identity; matching project URI and declarations permit consistent catalogue filtering.
- Target field
- contributions
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/meili-2021-LCI%20for%20the%20oil%20and%20gas%20extraction.pdf
- Source location
- Imprint, Citation/Financing/Contractor
- Qualification
- Verified source-study contractor supplying the cited inventory modules. No journal-paper author promoted to inventory_author.
- Target field
- contributions
- Origin
- Source import
- Source reference
- Existing published CLIC inventory documentation
- Source location
- source
- Qualification
- Verified source-study contractor supplying the cited inventory modules. No journal-paper author promoted to inventory_author.
- Target field
- contributions
- Origin
- Editor verification
- Source reference
- https://api.ror.org/v2/organizations/024s10v78
- Source location
- Organization identity and registered names
- Qualification
- Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope.
- Target field
- funding
- Origin
- Editor verification
- Source reference
- https://api.ror.org/v2/organizations/04t48sm91
- Source location
- Organization identity and registered names
- Qualification
- Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope.
- Target field
- publications
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/data/public-lci-reports/
- Source location
- Original 2021 report title/imprint, ESU public source index and source-specific native reference
- Qualification
- Verify full report bylines and ESU historical affiliation from the original 2021 report. Preserve existing supporting-source roles, inventory-contributor declarations and licensing. Gas-report author order in embedded XML is inconsistent with the published imprint; report byline takes precedence. Later report dates/author order must not overwrite the 2021 source.
- Target field
- methodology_notes
- Origin
- Editor verification
- Source reference
- https://esu-services.ch/fileadmin/download/publicLCI/ESU-2021-XML-LCIoilandgas.zip
- Source location
- ESU-2021-XML-LCIoilandgas/EcoSpold-crude-gas exploration and extraction-2020-v3.0._X-Venting.xml, dataset 1; native metadata and exchange numbers in comparison artifact
- Qualification
- Quantity and importer-uncertainty screens require exact provider/flow identity. Unmatched exchanges, source Nm3 reference conditions, source allocation and pedigree/correlation assumptions remain explicit limits. Source 'uncertaintyAdjustments=none' is distinct from absent exchange uncertainty. Reference-year enrichments identify the explicit 2019 source model context, not measurement of every input. No measurement periods, exact plant lifetime, software of CLIC creation or numeric TRL are guessed.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/design_capacity; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Design capacity: Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/design_capacity_unit; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Design capacity unit: Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/capacity_factor_percent; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Capacity factor (%): Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/annual_production_volume; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Annual production volume: Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/annual_production_volume_unit; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Annual production volume unit: Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/annual_production_volume_year; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Annual production volume year: Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- fields/plant_lifetime_years; source_context_review and source native EcoSpold record
- Qualification
- Technical-characterisation review TC-274. Plant or represented-asset lifetime (years): Unspecified. Basis: Preserve source-qualified regional annual quantities, three design lives and the nominal generator rating. Other field/stock/drilled-length or pollutant-intensity context does not establish additional facility output, lifetime or utilization. Evidence classification: exact guarded source scope and parameter review. Confidence: high for retained source scope not current facility measurement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- Exact source_context_review/facts/Time period and source native applicability fields; 2021 report introduction, process chapters and unit-process appendix
- Qualification
- Technical-characterisation review TC-274. Commercial maturity stage: mature_commercial. Basis: Retain the established commercial oil/gas extraction, combustion, infrastructure, transport or supply-chain route assessment. For emission/discharge helper references this characterizes the underlying industrial context, not a separately marketed treatment technology or an endorsement of environmental performance. Evidence classification: source specific archetype and retained vintage assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- Exact source_context_review/facts/Time period and source native applicability fields; 2021 report introduction, process chapters and unit-process appendix
- Qualification
- Technical-characterisation review TC-274. Technology readiness level: 9. Basis: Retain the existing curator assessment for the established underlying industrial route, separately from the accuracy of its regional archetype or emission helper. Native source agreement and a mature technology do not validate this exact generic process bill. Evidence classification: source specific archetype and retained vintage assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- Exact source_context_review/facts/Time period and source native applicability fields; 2021 report introduction, process chapters and unit-process appendix
- Qualification
- Technical-characterisation review TC-274. Technological representativeness: 3. Basis: Retain the partly representative archetype judgement. The exact source combines country statistics, generic onshore/offshore assumptions, qualified estimates and older infrastructure; it is not a newly measured plant survey for every geography. Evidence classification: source specific archetype and retained vintage assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- Exact source_context_review/facts/Time period and source native applicability fields; 2021 report introduction, process chapters and unit-process appendix
- Qualification
- Technical-characterisation review TC-274. Geographical representativeness: 4. Basis: Retain the source-qualified regional/proxy judgement and its exact declared geography. Regional outputs, trade routes, offshore/onshore assumptions, global storage and selected-country emission factors remain distinct; the name alone does not establish geographically representative measurements. Evidence classification: source specific archetype and retained vintage assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
- Target field
- technology_description
- Origin
- Editor verification
- Source reference
- https://zenodo.org/records/23935622
- Source location
- Exact source_context_review/facts/Time period and source native applicability fields; 2021 report introduction, process chapters and unit-process appendix
- Qualification
- Technical-characterisation review TC-274. Temporal representativeness: 3. Basis: The explicit ESU update models 2019 supply/trade conditions while retaining older process/infrastructure evidence. At the November2026 review date this is dated and needs cautious reuse (minimum category3). The exact infrastructure, drilling, produced-water, turbine or transport subgroups explicitly retain 1990s, 2001/2006, 2007, 2011 or 2015 evidence and are stale (minimum category4). Existing more conservative scores remain. The source's actual context is recorded below; publication/validity dates are not promoted to measurement years. Evidence classification: source specific archetype and retained vintage assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.