Trucks and lorries

power electronics, for lorry

Reference product power electronics, for lorry RER

Published Version 1.0.1 Latest published

Stable dataset identity power-electronics-for-lorry

Unit
kilogram
Reuse license
CC BY 4.0
Published
2026-11-03
Version
1.0.1
Technology maturity
See quality profile

Published inventory

Overview

Process description and catalog context. View scientific metadata

Description

Production reference for 1 kg finished automotive inverter, reconstructed from the Nordelöf v1.01 model. It represents a 30 kW, 400 V DC-input, air-cooled design used here as a heavy-duty-vehicle electronics proxy.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Trucks and lorries (transport/road/trucks)
Bookmarks
0
Raw file downloads
0
Generated export downloads
1

Classification path: Transport > Road transport > Trucks and lorries

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Data repository record

Nordelöf, A. (2018). Scalable Power Electronic Inverter LCI model, version 1.01. Chalmers University of Technology; CPM LCA Database. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43

Background database
ecoinvent / 3.8
Background system model
cut-off
Biosphere database
ecoinvent / 3.8

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Mature commercial
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 67 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per kilogram, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change 12.4695 kg CO2-Eq / kilogram
Screening result

This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.

Show all 16 indicator totals
Acidification 0.148587 mol H+-Eq / kilogram
Climate change 12.4695 kg CO2-Eq / kilogram
Freshwater ecotoxicity 65.5038 CTUe / kilogram
Freshwater eutrophication 0.0218098 kg P-Eq / kilogram
Marine eutrophication 0.0127871 kg N-Eq / kilogram
Terrestrial eutrophication 0.118255 mol N-Eq / kilogram
Human toxicity, cancer 1.4511e-08 CTUh / kilogram
Human toxicity, non-cancer 5.4796e-07 CTUh / kilogram
Ionising radiation 5.25358 kBq U235-Eq / kilogram
Land use 57.4855 dimensionless / kilogram
Ozone depletion 6.1978e-07 kg CFC-11-Eq / kilogram
Particulate matter 5.2615e-07 disease incidence / kilogram
Photochemical ozone formation 0.0437731 kg NMVOC-Eq / kilogram
Resource use, fossils 191.211 MJ, net calorific value / kilogram
Resource use, minerals and metals 0.00230322 kg Sb-Eq / kilogram
Water use 96.2427 m3 world Eq deprived / kilogram
Calculation details

Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact 4e70d56a85b1 · calculated 2026-11-03 09:20 UTC. These screening results do not replace a reviewed comparative LCA.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
power electronics, for lorry
RER
power electronics, for lorry
1
kilogram - Reference flow

Inputs

Technosphere inputs 66 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
market for copper, cathode
GLO
copper, cathode
0.09
kilogram
0.752431 kg CO2-Eq / kilogram 6.0% of total
BAFU:2025
metal working, average for copper product manufacturing
RER
metal working, average for copper product manufacturing
0.07
kilogram
0.0996643 kg CO2-Eq / kilogram 0.8% of total
BAFU:2025
market for lubricating oil
RER
lubricating oil
0.02
kilogram
0.0211414 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for tap water
Europe without Switzerland
tap water
0.33
kilogram
4.4753e-05 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for sulfuric acid
RER
sulfuric acid
8.30e-04
kilogram
0.000127111 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for sodium hydroxide, without water, in 50% solution state
GLO
sodium hydroxide, without water, in 50% solution state
1.66e-03
kilogram
0.00102937 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
metal working, average for aluminium product manufacturing
RER
metal working, average for aluminium product manufacturing
0.83
kilogram
1.7916 kg CO2-Eq / kilogram 14.4% of total
BAFU:2025
market group for electricity, low voltage
ENTSO-E
electricity, low voltage
3.04
kilowatt hour
0.892657 kg CO2-Eq / kilogram 7.2% of total
BAFU:2025
market for aluminium, cast alloy
GLO
aluminium, cast alloy
0.83
kilogram
3.55362 kg CO2-Eq / kilogram 28.5% of total
BAFU:2025
market for aluminium, wrought alloy
GLO
aluminium, wrought alloy
5.93e-05
kilogram
0.000294962 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
1.19e-03
kilogram
0.0116527 kg CO2-Eq / kilogram 0.1% of total
BAFU:2025
market for glass fibre
GLO
glass fibre
3.58e-03
kilogram
0.00826236 kg CO2-Eq / kilogram 0.1% of total
BAFU:2025
market for aluminium oxide, metallurgical
IAI Area, EU27 & EFTA
aluminium oxide, metallurgical
9.49e-04
kilogram
0.00111824 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for water, deionised
Europe without Switzerland
water, deionised
3.83
kilogram
0.00193454 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for hydrochloric acid, without water, in 30% solution state
RER
hydrochloric acid, without water, in 30% solution state
2.86e-04
kilogram
0.000159082 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
heat and power co-generation, natural gas, 1MW electrical, lean burn
Europe without Switzerland
heat, district or industrial, natural gas
8.48
megajoule
1.55302 kg CO2-Eq / kilogram 12.5% of total
BAFU:2025
market for potassium hydroxide
GLO
potassium hydroxide
6.17e-04
kilogram
0.000911262 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for brass
CH
brass
0.06
kilogram
0.119511 kg CO2-Eq / kilogram 1.0% of total
BAFU:2025
market for silicone product
RER
silicone product
6.77e-03
kilogram
0.0189168 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
casting, brass
CH
casting, brass
0.06
kilogram
0.00353003 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for polyphenylene sulfide
GLO
polyphenylene sulfide
7.99e-03
kilogram
0.0356654 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
market for nylon 6-6, glass-filled
RER
nylon 6-6, glass-filled
7.13e-04
kilogram
0.00510691 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for solder, bar, Sn95.5Ag3.9Cu0.6, for electronics industry
GLO
solder, bar, Sn95.5Ag3.9Cu0.6, for electronics industry
3.68e-05
kilogram
0.000591052 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for solder, paste, Sn95.5Ag3.9Cu0.6, for electronics industry
GLO
solder, paste, Sn95.5Ag3.9Cu0.6, for electronics industry
2.65e-03
kilogram
0.056859 kg CO2-Eq / kilogram 0.5% of total
BAFU:2025
market for isopropanol
RER
isopropanol
7.10e-04
kilogram
0.00133221 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for water, ultrapure
RER
water, ultrapure
5.81e-04
kilogram
2.5363e-07 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for sheet rolling, copper
GLO
sheet rolling, copper
0.07
kilogram
0.0210757 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for polyurethane, rigid foam
RER
polyurethane, rigid foam
9.15e-03
kilogram
0.0398292 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
market for nitrogen, liquid
RER
nitrogen, liquid
0.33
kilogram
0.0747103 kg CO2-Eq / kilogram 0.6% of total
BAFU:2025
market for gold
GLO
gold
7.47e-06
kilogram
0.0997432 kg CO2-Eq / kilogram 0.8% of total
BAFU:2025
market for zinc
GLO
zinc
4.95e-03
kilogram
0.00209955 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for polyethylene terephthalate, granulate, amorphous
GLO
polyethylene terephthalate, granulate, amorphous
0.01
kilogram
0.0388522 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
laminating service, foil, with acrylic binder
RER
laminating service, foil, with acrylic binder
0.03
square meter
0.000245414 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for nitric acid, without water, in 50% solution state
RER w/o RU
nitric acid, without water, in 50% solution state
7.47e-04
kilogram
0.00224245 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for potassium carbonate
GLO
potassium carbonate
6.17e-04
kilogram
0.00115094 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for tin
GLO
tin
2.35e-03
kilogram
0.0287369 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for polycarbonate
GLO
polycarbonate
5.72e-04
kilogram
0.00463152 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
reinforcing steel production
Europe without Austria
reinforcing steel
0.02
kilogram
0.029135 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for polypropylene, granulate
GLO
polypropylene, granulate
0.02
kilogram
0.0390232 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
market for aluminium oxide, metallurgical
IAI Area, EU27 & EFTA
aluminium oxide, metallurgical
8.05e-04
kilogram
0.000949106 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for zinc oxide
GLO
zinc oxide
1.73e-04
kilogram
0.000536196 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for silicone product
RER
silicone product
1.73e-04
kilogram
0.000481939 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for naphtha
RER
naphtha
0.02
kilogram
0.0146366 kg CO2-Eq / kilogram 0.1% of total
BAFU:2025
market for 2-methylpentane
GLO
2-methylpentane
3.56e-04
kilogram
0.000464291 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for benzaldehyde
RER
benzaldehyde
3.56e-05
kilogram
0.000153686 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for butyl acetate
RER
butyl acetate
5.93e-05
kilogram
0.000216572 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for capacitor, electrolyte type, < 2cm height
GLO
capacitor, electrolyte type, < 2cm height
7.71e-04
kilogram
0.0330827 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
market for capacitor, for surface-mounting
GLO
capacitor, for surface-mounting
4.86e-04
kilogram
0.02447 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for capacitor, tantalum-, for through-hole mounting
GLO
capacitor, tantalum-, for through-hole mounting
2.61e-04
kilogram
0.0422427 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
market for electric connector, wire clamp
GLO
electric connector, wire clamp
2.70e-03
kilogram
0.018083 kg CO2-Eq / kilogram 0.1% of total
BAFU:2025
market for switch, toggle type
GLO
switch, toggle type
3.56e-05
kilogram
0.000426729 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for light emitting diode
GLO
light emitting diode
2.37e-06
kilogram
0.000445006 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for diode, glass-, for surface-mounting
GLO
diode, glass-, for surface-mounting
5.15e-04
kilogram
0.0967782 kg CO2-Eq / kilogram 0.8% of total
BAFU:2025
market for electric connector, peripheral component interconnect buss
GLO
electric connector, peripheral component interconnect buss
5.81e-03
kilogram
0.291213 kg CO2-Eq / kilogram 2.3% of total
BAFU:2025
market for inductor, miniature radio frequency chip
GLO
inductor, miniature radio frequency chip
4.57e-05
kilogram
0.00254839 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for inductor, low value multilayer chip
GLO
inductor, low value multilayer chip
2.13e-06
kilogram
0.000170306 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for inductor, ring core choke type
GLO
inductor, ring core choke type
6.76e-04
kilogram
0.0260277 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for integrated circuit, logic type
GLO
integrated circuit, logic type
1.21e-03
kilogram
0.728886 kg CO2-Eq / kilogram 5.8% of total
BAFU:2025
market for integrated circuit, memory type
GLO
integrated circuit, memory type
4.27e-06
kilogram
0.00148387 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
market for resistor, surface-mounted
GLO
resistor, surface-mounted
1.54e-04
kilogram
0.0243715 kg CO2-Eq / kilogram 0.2% of total
BAFU:2025
market for wafer, fabricated, for integrated circuit
GLO
wafer, fabricated, for integrated circuit
7.16e-05
square meter
1.28003 kg CO2-Eq / kilogram 10.3% of total
BAFU:2025
market for transformer, low voltage use
GLO
transformer, low voltage use
3.56e-03
kilogram
0.0105646 kg CO2-Eq / kilogram 0.1% of total
BAFU:2025
market for transistor, surface-mounted
GLO
transistor, surface-mounted
2.18e-04
kilogram
0.0330031 kg CO2-Eq / kilogram 0.3% of total
BAFU:2025
market for printed wiring board, for surface mounting, Pb free surface
GLO
printed wiring board, for surface mounting, Pb free surface
2.61e-03
square meter
0.523257 kg CO2-Eq / kilogram 4.2% of total
BAFU:2025
diantimony trioxide
4.68e-04
kilogram
0.00380506 kg CO2-Eq / kilogram 0.0% of total
treatment of wastewater from lorry production, capacity 4.7E10l/year
CH
wastewater from lorry production
-3.81e-03
cubic meter
-0.00149223 kg CO2-Eq / kilogram 0.0% of total
BAFU:2025
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 2 versions · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  • Version 1.0.1 revises version 1.0.0.
  1. Version 1.0.0
    Published

    First published inventory; no earlier version is available for comparison.

    Superseded
  2. Version 1.0.1
    Published

    Updates the vehicle inventory to the documented carculator_truck 0.5.2 recipe. Model inputs, emissions and associated documentation follow the adopted source model where they differ…

    Published · Viewing · Latest
Show full version history table (2 versions)
Version Published Reason for this version Link
Version 1.0.1 2026-11-03 Updates the vehicle inventory to the documented carculator_truck 0.5.2 recipe. Model inputs, emissions and associated documentation follow the adopted source model where they differ from the previous public version. Current view
Version 1.0.0 Superseded Published 2026-07-15 First published inventory; no earlier version is available for comparison. Open version
About this version

Why this version changed

Updates the vehicle inventory to the documented carculator_truck 0.5.2 recipe. Model inputs, emissions and associated documentation follow the adopted source model where they differ from the previous public version.

Release notes

Source reference: https://doi.org/10.3390/su12135396.

These are modelled vehicle inventories, not measurements of a particular vehicle. The inventory description and model provenance retain the source assumptions and limitations. The declared background and biosphere profiles remain as stored; export conversions do not redefine the authored source.

Declared licence: CC BY 4.0. Source documents and external supplier inventories retain their own terms.

Changes from version 1.0.0 Compare this version with its predecessor. Exchanges are grouped by type and change; biosphere labels include their environmental compartments. Open the base version. Show changes Hide changes

Why this version changed

Updates the vehicle inventory to the documented carculator_truck 0.5.2 recipe. Model inputs, emissions and associated documentation follow the adopted source model where they differ from the previous public version.

Public revision record

This comparison is permanently visible with the published version so users can assess every detected change before reuse.

Modified exchanges
37
Added exchanges
30
Removed exchanges
2
Inventory metadata
4
Version metadata
17
Technosphere exchanges modified 36
Technosphere exchanges modified
Exchange / scope Field Previous value Revised value Reason
market for copper, cathode (technosphere / GLO / kilogram) Amount 0.000413247 0.08842161712639854 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for copper, cathode input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.08842161712639854 kilogram/kg finished inverter = previous 0.07811869304850541 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.7454961784615386 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local copper-coefficient correction, 2026-10-17 (approved). Wolff et al. (2020), Sustainability 12, 5396, DOI 10.3390/su12135396, supplementary archive https://mdpi-res.com/d_attachment/sustainability/sustainability-12-05396/article_deploy/sustainability-12-05396-s001.zip; member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, sheet Tabelle1. Copper C12 = 0.7454961784615386 kg; existing gross-material normalization SUM(C4:C35) = 9.543121490763363 kg; copper input = C12/SUM(C4:C35) = 0.07811869304850541 kg per kg of the inventory reference product. The former 0.0004132470057811588 kg/kg coefficient matches normalized diantimony trioxide (C13), rather than copper, suggesting a copied-row error; its historical cause is unproven. Retains the existing supplier and normalization convention. The denominator includes coating thinner and is not a demonstrated retained-product mass. This is a copper-only source correction; missing compounds, material-grade proxies, manufacturing coefficients and the overall electrical-system boundary remain unresolved. It does not add antimony trioxide or represent a complete reconstruction or validation of the assembly.
Database lci-long_haul_trucks Not set
Tag energy storage Not set
metal working, average for copper product manufacturing (technosphere / RER / kilogram) Amount 0.188 0.06975323323481748 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's metal working, average for copper product manufacturing input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.06975323323481748 kilogram/kg finished inverter = previous 0.06162555711260215 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.5881001784615386 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Copper machining. Local copper-processing design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model, B23 = 30 kW, G23 = 400 V, O23 = Air; G149 copper sheet rolling = 0.5881001784615386 kg and G150 copper machining = 0.5881001784615386 kg per inverter. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design, but C42/C43 each contain 1.7975120842105266 kg processing service, matching a larger 100 kW configuration in the source-model reconstruction. They are inconsistent with the transferred 30 kW material recipe. Retain existing gross-material basis SUM(C4:C35) = 9.543121490763363 kg; each service input = original G149 or G150 / SUM(C4:C35) = 0.06162555711260215 kg per kg inventory reference product, replacing 0.1879999935626984 kg/kg. These are separate manufacturing services applied to the copper parts; service kg are not additional kg of delivered or retained copper. Existing suppliers provide upstream process inputs and manufacturing losses; no additional yield or metal input is added. Purchased cathode copper remains 0.07811869304850541 kg/kg. Other manufacturing coefficients and all direct material inputs remain unchanged. The gross denominator includes coating thinner and is not verified finished-inverter mass. Missing subcomponents, other mixed-design manufacturing flows, material-grade proxies and vehicle electrical-system scope remain unresolved. This targeted correction does not establish a complete coherent inverter inventory or a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for lubricating oil (technosphere / RER / kilogram) Amount 0.01257 0.015419006238440225 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for lubricating oil input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.015419006238440225 kilogram/kg finished inverter = previous 0.013622377135806659 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.13 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. lubricating oil: original M102 = 130 g per inverter = 0.13 kg; new aggregate input = 0.013622377135806659 kg/kg (formerly 0.01257000025361776 kg/kg). Existing RER supplier share = 1.0; row input = 0.013622377135806659 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for tap water (technosphere / Europe without Switzerland / kilogram) Amount 0.28 0.3321016728279433 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for tap water input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.3321016728279433 kilogram/kg finished inverter = previous 0.2934050460019896 * 9.543121490763363/8.431152954326238. The represented source batch remains 2.8 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
tap water: source M113 converted to signed inventory batch amount 2.8 kilogram; divide by 9.543121490763363 kg to obtain 0.2934050460019896 kilogram/kg electronics (formerly 0.2800000011920929). Local manufacturing-water design correction, 2026-10-17 (approved). Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: 30 kW, 400 V, air cooled (B23, G23, O23). M109 ultrapure water = 4.9 g = 0.0049 kg per inverter; M112 deionised water = 32.2639665 kg; M113 tap water = 2.8 kg; M137 explicit wastewater discharge = 32.14 dm3 = 0.03214 m3 per inverter. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . Retain gross-material normalization from Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, SUM(C4:C35) = 9.543121490763363 kg. Align the four quantities to the original 30 kW material design. Use the original explicit wastewater discharge, not the sum of incoming water supplies or a presumed 100% return rate. Retain RER ultrapure-water, Europe without Switzerland deionised/tap-water suppliers and CH lorry-production wastewater treatment. The latter is an existing geographic/process/pollutant-profile proxy, not a validated electronics effluent composition. Preserve the existing negative waste-technosphere sign and cubic-metre unit. These are manufacturing-water quantities per kg electronics, not final vehicle energy or operating-water demand. No additional dilution, density or concentration factor is introduced. Other materials, manufacturing energy, processing services, cutting fluid and all other outputs remain unchanged. The four source quantities do not establish a complete water/fluid balance: diluted waste-oil handling, other aqueous paths, retention and evaporation remain unresolved. No balancing flow or inferred water fate is added. Gross normalization includes coating thinner and is not verified finished-inverter mass; other component omissions, process/grade proxies and vehicle electrical-system scope remain open. This targeted source correction is not a full mass-balance reconstruction or system-metal result.
Database lci-long_haul_trucks Not set
Tag other Not set
market for sulfuric acid (technosphere / RER / kilogram) Amount 0.00146 0.0008302541820698583 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for sulfuric acid input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0008302541820698583 kilogram/kg finished inverter = previous 0.000733512615004974 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.007 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. sulfuric acid: original M111 = 7 g per inverter = 0.007 kg; new aggregate input = 0.000733512615004974 kg/kg (formerly 0.001460000057704747 kg/kg). Existing RER supplier share = 1.0; row input = 0.000733512615004974 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for sodium hydroxide, without water, in 50% solution state (technosphere / GLO / kilogram) Amount 0.0008383 0.0016605083641397164 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for sodium hydroxide, without water, in 50% solution state input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.001351316321418514 kilogram/kg finished inverter = previous 0.0011938603743632756 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.01139315459555697 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. sodium hydroxide, without water, in 50% solution state: original M94 = 14 g per inverter = 0.014 kg; new aggregate input = 0.001467025230009948 kg/kg (formerly 0.0008383000167668797 kg/kg). Existing RoW supplier share = 0.8137967568254978; row input = 0.0011938603743632756 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Product Not set sodium hydroxide, without water, in 50% solution state
Tag other Not set
metal working, average for aluminium product manufacturing (technosphere / RER / kilogram) Amount 0.7356 0.8326168622095349 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's metal working, average for aluminium product manufacturing input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.8326168622095349 kilogram/kg finished inverter = previous 0.7355999946594238 * 9.543121490763363/8.431152954326238. The represented source batch remains 7.019920117639763 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market group for electricity, low voltage (technosphere / ENTSO-E / kilowatt hour) Amount 2.829 3.0359310925400584 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the vehicle's recalculated energy demand and declared energy-carrier supply route. Quantity, supplier and any explicit proxy/fallback policy follow the source recipe together; a supplier-name correction alone does not explain the energy recalculation.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 3.0359310925400584 kilowatt hour/kg finished inverter = previous 2.6821831226579635 * 9.543121490763363/8.431152954326238. The represented source batch remains 25.5963994 kilowatt hour per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Manufacturing electricity. Local manufacturing-energy design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. SUM(M84:M88) = 25.5963994 kWh per inverter (assembly/building services 3.3259999999999996; casing production 19.279999999999998; electroplating 0.27; power-module production 1.7003994000000002; PCB assembly 1.02 kWh). M89 = 71.5 MJ natural-gas heat per inverter (source numeric text converted to number). Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design. C39 instead transfers 27 kWh and C40 transfers 64.7 MJ, differing from that design. Retain existing gross-material normalization SUM(C4:C35) = 9.543121490763363 kg. Electricity = SUM(M84:M88)/SUM(C4:C35) = 2.6821831226579635 kWh/kg, replacing 2.828999996185303 kWh/kg. Heat = M89/SUM(C4:C35) = 7.492307424693663 MJ/kg, replacing 6.778999805450439 MJ/kg. Retain the existing ENTSO-E low-voltage electricity market group and Europe without Switzerland natural-gas CHP heat supplier as existing geographic/process proxies; this correction aligns quantities, not plant technology or geographic representativeness. These are manufacturing-energy inputs per kg electronics, not vehicle operating-energy inputs or equipment allocation per MJ final energy. All material purchases, processing-service quantities and other inputs remain unchanged. No additional conversion efficiency, yield or future trajectory is introduced. The gross denominator includes coating thinner and is not verified finished-inverter mass. Missing components, other mixed-design manufacturing flows, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted source correction does not reconstruct a complete inverter inventory or establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag energy chain Not set
heat and power co-generation, natural gas, 1MW electrical, lean burn (technosphere / Europe without Switzerland / megajoule) Amount 6.779 8.480453431142124
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 8.480453431142124 megajoule/kg finished inverter = previous 7.492307424693663 * 9.543121490763363/8.431152954326238. The represented source batch remains 71.5 megajoule per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Manufacturing heat. Local manufacturing-energy design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. SUM(M84:M88) = 25.5963994 kWh per inverter (assembly/building services 3.3259999999999996; casing production 19.279999999999998; electroplating 0.27; power-module production 1.7003994000000002; PCB assembly 1.02 kWh). M89 = 71.5 MJ natural-gas heat per inverter (source numeric text converted to number). Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design. C39 instead transfers 27 kWh and C40 transfers 64.7 MJ, differing from that design. Retain existing gross-material normalization SUM(C4:C35) = 9.543121490763363 kg. Electricity = SUM(M84:M88)/SUM(C4:C35) = 2.6821831226579635 kWh/kg, replacing 2.828999996185303 kWh/kg. Heat = M89/SUM(C4:C35) = 7.492307424693663 MJ/kg, replacing 6.778999805450439 MJ/kg. Retain the existing ENTSO-E low-voltage electricity market group and Europe without Switzerland natural-gas CHP heat supplier as existing geographic/process proxies; this correction aligns quantities, not plant technology or geographic representativeness. These are manufacturing-energy inputs per kg electronics, not vehicle operating-energy inputs or equipment allocation per MJ final energy. All material purchases, processing-service quantities and other inputs remain unchanged. No additional conversion efficiency, yield or future trajectory is introduced. The gross denominator includes coating thinner and is not verified finished-inverter mass. Missing components, other mixed-design manufacturing flows, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted source correction does not reconstruct a complete inverter inventory or establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for nickel, class 1 (technosphere / GLO / kilogram) Amount 0.001047875 0.0011860772551308921 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for nickel, class 1 input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0011860772551308921 kilogram/kg finished inverter = previous 0.001047875033691525 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.009999998753655976 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for glass fibre (technosphere / GLO / kilogram) Amount 0.003162601 0.003579710394605525 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for glass fibre input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.003579710394605525 kilogram/kg finished inverter = previous 0.00316260103136301 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.030181085869110717 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag energy storage Not set
market for aluminium oxide, metallurgical (technosphere / IAI Area, EU27 & EFTA / kilogram) Amount 0.0008383 0.0009488617513970682 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for aluminium oxide, metallurgical input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0009488617513970682 kilogram/kg finished inverter = previous 0.0008382999803870916 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.00799999855853856 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Product Not set aluminium oxide, metallurgical
Tag other Not set
market for water, deionised (technosphere / Europe without Switzerland / kilogram) Amount 1.92 3.8267561595409725 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for water, deionised input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 3.8267561595409725 kilogram/kg finished inverter = previous 3.380860919692554 * 9.543121490763363/8.431152954326238. The represented source batch remains 32.2639665 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
water, deionised: source M112 converted to signed inventory batch amount 32.2639665 kilogram; divide by 9.543121490763363 kg to obtain 3.380860919692554 kilogram/kg electronics (formerly 1.919999957084656). Local manufacturing-water design correction, 2026-10-17 (approved). Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: 30 kW, 400 V, air cooled (B23, G23, O23). M109 ultrapure water = 4.9 g = 0.0049 kg per inverter; M112 deionised water = 32.2639665 kg; M113 tap water = 2.8 kg; M137 explicit wastewater discharge = 32.14 dm3 = 0.03214 m3 per inverter. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . Retain gross-material normalization from Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, SUM(C4:C35) = 9.543121490763363 kg. Align the four quantities to the original 30 kW material design. Use the original explicit wastewater discharge, not the sum of incoming water supplies or a presumed 100% return rate. Retain RER ultrapure-water, Europe without Switzerland deionised/tap-water suppliers and CH lorry-production wastewater treatment. The latter is an existing geographic/process/pollutant-profile proxy, not a validated electronics effluent composition. Preserve the existing negative waste-technosphere sign and cubic-metre unit. These are manufacturing-water quantities per kg electronics, not final vehicle energy or operating-water demand. No additional dilution, density or concentration factor is introduced. Other materials, manufacturing energy, processing services, cutting fluid and all other outputs remain unchanged. The four source quantities do not establish a complete water/fluid balance: diluted waste-oil handling, other aqueous paths, retention and evaporation remain unresolved. No balancing flow or inferred water fate is added. Gross normalization includes coating thinner and is not verified finished-inverter mass; other component omissions, process/grade proxies and vehicle electrical-system scope remain open. This targeted source correction is not a full mass-balance reconstruction or system-metal result.
Database lci-long_haul_trucks Not set
Tag other Not set
market for hydrochloric acid, without water, in 30% solution state (technosphere / RER / kilogram) Amount 0.000549497 0.0002861767557854506 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for hydrochloric acid, without water, in 30% solution state input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0002861767557854506 kilogram/kg finished inverter = previous 0.00025283131964057157 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.0024127999999999997 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. hydrochloric acid, without water, in 30% solution state: original M100 = 2.4128 g per inverter = 0.0024127999999999997 kg; new aggregate input = 0.00025283131964057157 kg/kg (formerly 0.0005494970246218145 kg/kg). Existing RER supplier share = 1.0; row input = 0.00025283131964057157 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for potassium hydroxide (technosphere / GLO / kilogram) Amount 0.001194 0.0006167602495376089 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for potassium hydroxide input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0006167602495376089 kilogram/kg finished inverter = previous 0.0005448950854322663 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.0052 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. potassium hydroxide: original M108 = 5.2 g per inverter = 0.0052 kg; new aggregate input = 0.0005448950854322663 kg/kg (formerly 0.001194000011309981 kg/kg). Existing GLO supplier share = 1.0; row input = 0.0005448950854322663 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for brass (technosphere / CH / kilogram) Amount 0.049470228 0.05599476026761035 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for brass input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.05599476026761035 kilogram/kg finished inverter = previous 0.04947022721171379 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.47210038845705243 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for silicone product (technosphere / RER / kilogram) Amount 0.000598 0.00677379903464648 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for silicone product input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.00677379903464648 kilogram/kg finished inverter = previous 0.005984513117458335 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.05711093574297189 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local silicone-coefficient correction, 2026-10-17 (approved). Wolff et al. (2020), Sustainability 12, 5396, DOI 10.3390/su12135396, supplementary archive https://mdpi-res.com/d_attachment/sustainability/sustainability-12-05396/article_deploy/sustainability-12-05396-s001.zip; member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, sheet Tabelle1. C26 silicone adhesive = 0.0012269999999999998 kg; C27 silicone granulates = 0.01598393574297189 kg; C28 silicone potting gel = 0.0399 kg. Total = 0.05711093574297189 kg per source batch; existing gross-material normalization SUM(C4:C35) = 9.543121490763363 kg. Input = SUM(C26:C28)/SUM(C4:C35) = 0.005984513117458335 kg per kg of inventory reference product, replacing 0.000598000013269484 kg/kg (about tenfold too low). The historical cause of the discrepancy is unproven. Retain the existing RER silicone-product market as a generic proxy for these three silicone forms; their separate formulations and elemental silicon fractions are not established. These are silicone-product purchases, not elemental-silicon content or a validated finished-product composition. Source C33 TIM silicone oil is separate and is not included in this three-material correction. The existing denominator includes coating thinner and gross manufacturing allowances; it is not verified retained assembly mass. No additional yield, density, renormalization or future trajectory is introduced. Missing ingredients/components, manufacturing coefficients, other grade proxies and the vehicle electrical-system boundary remain unresolved. This is a targeted source-coefficient correction, not a complete assembly reconstruction or system-metal result.
Database lci-long_haul_trucks Not set
Tag other Not set
casting, brass (technosphere / CH / kilogram) Amount 0.07349 0.0557407038569799 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's casting, brass input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0557407038569799 kilogram/kg finished inverter = previous 0.04924577356107908 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.4699584 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Brass casting. Local brass-casting and busbar-lamination design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. G151 brass-parts casting = 0.4699584 kg per inverter; G162 lamination of bus bar with PET foil = 0.26671956164383565 m2 per inverter. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design. However, C44 casting = 0.7013952 kg and C45 lamination = 0.531138960579244 m2 match the reconstructed larger 100 kW configuration and are inconsistent with the transferred material design. Retain existing gross-material normalization SUM(C4:C35) = 9.543121490763363 kg. Casting input = G151/SUM(C4:C35) = 0.04924577356107908 kg/kg, replacing 0.07349000126123428 kg/kg. Lamination input = G162/SUM(C4:C35) = 0.027948880447764318 m2/kg, replacing 0.05565673485398293 m2/kg. Retain existing CH brass-casting and RER acrylic-binder foil-lamination service suppliers. The latter remains a process proxy for the original PET busbar lamination; matching area does not establish the precise binder formulation. Service quantities are manufacturing operations, not additional retained brass, foil or binder mass. All material purchases, other processing and energy inputs and supplier manufacturing losses remain unchanged; no additional yield or normalization is introduced. The gross denominator includes coating thinner and is not verified finished-inverter mass. Missing components, other mixed-design manufacturing flows, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted correction is not a complete inverter reconstruction or a corrected whole-system metal result.
Database lci-long_haul_trucks Not set
Tag other Not set
market for polyphenylene sulfide (technosphere / GLO / kilogram) Amount 0.007063142 0.007994686231706467 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for polyphenylene sulfide input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.007994686231706467 kilogram/kg finished inverter = previous 0.007063142023980618 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.06740442244136328 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for nylon 6-6, glass-filled (technosphere / RER / kilogram) Amount 0.000629988 0.0007130758766717518 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for nylon 6-6, glass-filled input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0007130758766717518 kilogram/kg finished inverter = previous 0.0006299879751168191 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.006012051784259812 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag energy storage Not set
market for isopropanol (technosphere / RER / kilogram) Amount 0.001330261 0.0007099859334100245 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for isopropanol input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0007099859334100245 kilogram/kg finished inverter = previous 0.000627258073345682 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.005986 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. isopropanol: original M101 = 5.986 g per inverter = 0.005986 kg; new aggregate input = 0.000627258073345682 kg/kg (formerly 0.001330261002294719 kg/kg). Existing RER supplier share = 1.0; row input = 0.000627258073345682 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for water, ultrapure (technosphere / RER / kilogram) Amount 0.00115 0.0005811779274489007 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for water, ultrapure input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0005811779274489007 kilogram/kg finished inverter = previous 0.0005134588305034817 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.004899999999999999 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
water, ultrapure: source M109 converted to signed inventory batch amount 0.0049 kilogram; divide by 9.543121490763363 kg to obtain 0.0005134588305034817 kilogram/kg electronics (formerly 0.001150000025518239). Local manufacturing-water design correction, 2026-10-17 (approved). Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: 30 kW, 400 V, air cooled (B23, G23, O23). M109 ultrapure water = 4.9 g = 0.0049 kg per inverter; M112 deionised water = 32.2639665 kg; M113 tap water = 2.8 kg; M137 explicit wastewater discharge = 32.14 dm3 = 0.03214 m3 per inverter. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . Retain gross-material normalization from Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, SUM(C4:C35) = 9.543121490763363 kg. Align the four quantities to the original 30 kW material design. Use the original explicit wastewater discharge, not the sum of incoming water supplies or a presumed 100% return rate. Retain RER ultrapure-water, Europe without Switzerland deionised/tap-water suppliers and CH lorry-production wastewater treatment. The latter is an existing geographic/process/pollutant-profile proxy, not a validated electronics effluent composition. Preserve the existing negative waste-technosphere sign and cubic-metre unit. These are manufacturing-water quantities per kg electronics, not final vehicle energy or operating-water demand. No additional dilution, density or concentration factor is introduced. Other materials, manufacturing energy, processing services, cutting fluid and all other outputs remain unchanged. The four source quantities do not establish a complete water/fluid balance: diluted waste-oil handling, other aqueous paths, retention and evaporation remain unresolved. No balancing flow or inferred water fate is added. Gross normalization includes coating thinner and is not verified finished-inverter mass; other component omissions, process/grade proxies and vehicle electrical-system scope remain open. This targeted source correction is not a full mass-balance reconstruction or system-metal result.
Database lci-long_haul_trucks Not set
Tag other Not set
market for sheet rolling, copper (technosphere / GLO / kilogram) Amount 0.188 0.06975323323481748 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for sheet rolling, copper input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.06975323323481748 kilogram/kg finished inverter = previous 0.06162555711260215 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.5881001784615386 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Copper sheet rolling. Local copper-processing design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model, B23 = 30 kW, G23 = 400 V, O23 = Air; G149 copper sheet rolling = 0.5881001784615386 kg and G150 copper machining = 0.5881001784615386 kg per inverter. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design, but C42/C43 each contain 1.7975120842105266 kg processing service, matching a larger 100 kW configuration in the source-model reconstruction. They are inconsistent with the transferred 30 kW material recipe. Retain existing gross-material basis SUM(C4:C35) = 9.543121490763363 kg; each service input = original G149 or G150 / SUM(C4:C35) = 0.06162555711260215 kg per kg inventory reference product, replacing 0.1879999935626984 kg/kg. These are separate manufacturing services applied to the copper parts; service kg are not additional kg of delivered or retained copper. Existing suppliers provide upstream process inputs and manufacturing losses; no additional yield or metal input is added. Purchased cathode copper remains 0.07811869304850541 kg/kg. Other manufacturing coefficients and all direct material inputs remain unchanged. The gross denominator includes coating thinner and is not verified finished-inverter mass. Missing subcomponents, other mixed-design manufacturing flows, material-grade proxies and vehicle electrical-system scope remain unresolved. This targeted correction does not establish a complete coherent inverter inventory or a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for polyurethane, rigid foam (technosphere / RER / kilogram) Amount 0.00808 0.00914565571456649 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for polyurethane, rigid foam input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.00914565571456649 kilogram/kg finished inverter = previous 0.008080000057816505 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.07710842219711792 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for nitrogen, liquid (technosphere / RER / kilogram) Amount 0.452 0.3338807889323787 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for nitrogen, liquid input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.3338807889323787 kilogram/kg finished inverter = previous 0.2949768587484288 * 9.543121490763363/8.431152954326238. The represented source batch remains 2.8150000000000004 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. nitrogen, liquid: original M104 = 2.815 kg per inverter = 2.815 kg; new aggregate input = 0.2949768587484288 kg/kg (formerly 0.4519999921321869 kg/kg). Existing RER supplier share = 1.0; row input = 0.2949768587484288 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for gold (technosphere / GLO / kilogram) Amount 6.6e-06 7.470461047065837e-06 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for gold input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 7.470461047065837e-06 kilogram/kg finished inverter = previous 6.599999778700294e-06 * 9.543121490763363/8.431152954326238. The represented source batch remains 6.298459972714822e-05 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for zinc (technosphere / GLO / kilogram) Amount 0.004371788 0.004948374577490781 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for zinc input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.004948374577490781 kilogram/kg finished inverter = previous 0.004371787887066603 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.04172050293812425 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for polyethylene terephthalate, granulate, amorphous (technosphere / GLO / kilogram) Amount 0.012259 0.013875815894644187 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for polyethylene terephthalate, granulate, amorphous input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.013875815894644187 kilogram/kg finished inverter = previous 0.01225899998098612 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.11698912617381631 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
laminating service, foil, with acrylic binder (technosphere / RER / square meter) Amount 0.055656733 0.03163500449923341 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's laminating service, foil, with acrylic binder input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.03163500449923341 square meter/kg finished inverter = previous 0.027948880447764318 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.26671956164383565 square meter per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Busbar foil lamination. Local brass-casting and busbar-lamination design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. G151 brass-parts casting = 0.4699584 kg per inverter; G162 lamination of bus bar with PET foil = 0.26671956164383565 m2 per inverter. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design. However, C44 casting = 0.7013952 kg and C45 lamination = 0.531138960579244 m2 match the reconstructed larger 100 kW configuration and are inconsistent with the transferred material design. Retain existing gross-material normalization SUM(C4:C35) = 9.543121490763363 kg. Casting input = G151/SUM(C4:C35) = 0.04924577356107908 kg/kg, replacing 0.07349000126123428 kg/kg. Lamination input = G162/SUM(C4:C35) = 0.027948880447764318 m2/kg, replacing 0.05565673485398293 m2/kg. Retain existing CH brass-casting and RER acrylic-binder foil-lamination service suppliers. The latter remains a process proxy for the original PET busbar lamination; matching area does not establish the precise binder formulation. Service quantities are manufacturing operations, not additional retained brass, foil or binder mass. All material purchases, other processing and energy inputs and supplier manufacturing losses remain unchanged; no additional yield or normalization is introduced. The gross denominator includes coating thinner and is not verified finished-inverter mass. Missing components, other mixed-design manufacturing flows, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted correction is not a complete inverter reconstruction or a corrected whole-system metal result.
Database lci-long_haul_trucks Not set
Tag other Not set
market for nitric acid, without water, in 50% solution state (technosphere / RER w/o RU / kilogram) Amount 0.001268 0.0007472287638628725 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for nitric acid, without water, in 50% solution state input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0007472287638628725 kilogram/kg finished inverter = previous 0.0006601613535044766 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.006300000000000001 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. nitric acid, without water, in 50% solution state: original M103 = 6.3 g per inverter = 0.0063 kg; new aggregate input = 0.0006601613535044766 kg/kg (formerly 0.001267999992705882 kg/kg). Existing RER w/o RU supplier share = 1.0; row input = 0.0006601613535044766 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for potassium carbonate (technosphere / GLO / kilogram) Amount 0.00119 0.0006167602495376089 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for potassium carbonate input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0006167602495376089 kilogram/kg finished inverter = previous 0.0005448950854322663 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.0052 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
Local manufacturing-chemical design correction, 2026-10-17 (approved). Original Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: B23 = 30 kW, G23 = 400 V, O23 = Air. Model/report: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . The bulk-material transfer in Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, corresponds to that 30 kW design but uses different-design manufacturing-chemical quantities. Align nine existing chemical groups to original model rows M94, M100:M104, M107:M108 and M111. Retain existing gross-material denominator SUM(C4:C35) = 9.543121490763363 kg. Convert source g to kg by division by 1000; source nitrogen is already in kg. potassium carbonate: original M107 = 5.2 g per inverter = 0.0052 kg; new aggregate input = 0.0005448950854322663 kg/kg (formerly 0.001189999980852008 kg/kg). Existing GLO supplier share = 1.0; row input = 0.0005448950854322663 kg/kg. Retain existing supplier identities, geographic/process proxies and regional shares, including all three sodium-hydroxide regions. The selected acid/alkali products retain their existing without-water mass conventions in the stated solution state; no additional dilution or concentration multiplier is introduced. Liquid nitrogen remains the source-recommended process proxy. Lubricating oil is separate from the still-missing source cutting fluid, which is not added. Other material inputs, manufacturing energy, processing services, water and waste outputs remain unchanged. No new yield, normalization or future trajectory. The gross denominator includes coating thinner and is not verified finished inverter mass; missing components, other manufacturing-flow inconsistencies, grade/process proxies and vehicle electrical-system scope remain unresolved. This targeted quantity correction does not validate full chemical stoichiometry, manufacturing balances or the complete inverter inventory and does not establish a corrected whole-system metal total.
Database lci-long_haul_trucks Not set
Tag other Not set
market for tin (technosphere / GLO / kilogram) Amount 0.002076207 0.0023500339019227605 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for tin input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0023500339019227605 kilogram/kg finished inverter = previous 0.002076206961646676 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.0198134952749629 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for polycarbonate (technosphere / GLO / kilogram) Amount 0.000505023 0.0005716295065605329 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for polycarbonate input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.0004896640112459139 kilogram/kg finished inverter = previous 0.0004326081543695182 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.004128432175043224 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Product Not set polycarbonate
Tag other Not set
reinforcing steel production (technosphere / Europe without Austria / kilogram) Amount 0.017635739 0.019961682082880492 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's reinforcing steel production input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.019961682082880492 kilogram/kg finished inverter = previous 0.01763573847711086 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.168299994866399 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Tag other Not set
market for polypropylene, granulate (technosphere / GLO / kilogram) Amount 0.016385205 0.018546218056535065 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for polypropylene, granulate input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): 0.006609288952500422 kilogram/kg finished inverter = previous 0.005839171819388866 * 9.543121490763363/8.431152954326238. The represented source batch remains 0.055723926077869704 kilogram per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
Database lci-long_haul_trucks Not set
Product Not set polypropylene, granulate
Tag other Not set
treatment of wastewater from lorry production, capacity 4.7E10l/year (technosphere / CH / cubic meter) Amount -0.00220115 -0.0038120527731036065 Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Allocate the corresponding vehicle production/retirement reference over the documented transport lifetime and service basis. This keeps the production dose and operating model consistent.
Inventory comment Not set CURRENT OUTPUT NORMALIZATION (approved): -0.0038120527731036065 cubic meter/kg finished inverter = previous -0.0033678707780371232 * 9.543121490763363/8.431152954326238. The represented source batch remains -0.03214 cubic meter per 8.431152954326238-kg inverter. Source: Nordelof v1.01, 1. Mass configuration L15:L88/L89 and Summary Q23. This supersedes any older per-kg coefficients quoted below; supplier, sign and original batch quantity are unchanged. See dataset comment for method and remaining coverage/balance/proxy gaps.
HISTORICAL NOTES:
wastewater from lorry production: source M137 converted to signed inventory batch amount -0.03214 cubic meter; divide by 9.543121490763363 kg to obtain -0.0033678707780371232 cubic meter/kg electronics (formerly -0.002201149938628078). Local manufacturing-water design correction, 2026-10-17 (approved). Nordelof automotive inverter LCI model v1.01, Summary of LCI Model: 30 kW, 400 V, air cooled (B23, G23, O23). M109 ultrapure water = 4.9 g = 0.0049 kg per inverter; M112 deionised water = 32.2639665 kg; M113 tap water = 2.8 kg; M137 explicit wastewater discharge = 32.14 dm3 = 0.03214 m3 per inverter. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43 . Retain gross-material normalization from Wolff et al. (2020), DOI 10.3390/su12135396, supplementary member SI_Scalable_Life_Cycle _Inventory/Production/Components/Power-el..xlsx, Tabelle1, SUM(C4:C35) = 9.543121490763363 kg. Align the four quantities to the original 30 kW material design. Use the original explicit wastewater discharge, not the sum of incoming water supplies or a presumed 100% return rate. Retain RER ultrapure-water, Europe without Switzerland deionised/tap-water suppliers and CH lorry-production wastewater treatment. The latter is an existing geographic/process/pollutant-profile proxy, not a validated electronics effluent composition. Preserve the existing negative waste-technosphere sign and cubic-metre unit. These are manufacturing-water quantities per kg electronics, not final vehicle energy or operating-water demand. No additional dilution, density or concentration factor is introduced. Other materials, manufacturing energy, processing services, cutting fluid and all other outputs remain unchanged. The four source quantities do not establish a complete water/fluid balance: diluted waste-oil handling, other aqueous paths, retention and evaporation remain unresolved. No balancing flow or inferred water fate is added. Gross normalization includes coating thinner and is not verified finished-inverter mass; other component omissions, process/grade proxies and vehicle electrical-system scope remain open. This targeted source correction is not a full mass-balance reconstruction or system-metal result.
Database lci-long_haul_trucks Not set
Product Not set wastewater from lorry production
Tag other Not set
Technosphere exchanges added 30
Technosphere exchanges added
Exchange / scope Field Previous value Revised value Reason
market for aluminium, cast alloy (technosphere / GLO / kilogram) Amount Not present 0.8325575632377944 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for aluminium, cast alloy input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for aluminium, wrought alloy (technosphere / GLO / kilogram) Amount Not present 5.929897174058365e-05 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for aluminium, wrought alloy input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for solder, bar, Sn95.5Ag3.9Cu0.6, for electronics industry (technosphere / GLO / kilogram) Amount Not present 3.6768399491665156e-05 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for solder, bar, Sn95.5Ag3.9Cu0.6, for electronics industry input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for solder, paste, Sn95.5Ag3.9Cu0.6, for electronics industry (technosphere / GLO / kilogram) Amount Not present 0.002653848189116153 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for solder, paste, Sn95.5Ag3.9Cu0.6, for electronics industry input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for aluminium oxide, metallurgical (technosphere / IAI Area, EU27 & EFTA / kilogram) Amount Not present 0.0008053465566077626 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for aluminium oxide, metallurgical input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for zinc oxide (technosphere / GLO / kilogram) Amount Not present 0.0001725742621302348 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for zinc oxide input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for silicone product (technosphere / RER / kilogram) Amount Not present 0.0001725742621302348 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for silicone product input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for naphtha (technosphere / RER / kilogram) Amount Not present 0.018146984265241188 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for naphtha input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for 2-methylpentane (technosphere / GLO / kilogram) Amount Not present 0.00035582322088708213 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for 2-methylpentane input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for benzaldehyde (technosphere / RER / kilogram) Amount Not present 3.558232208870821e-05 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for benzaldehyde input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for butyl acetate (technosphere / RER / kilogram) Amount Not present 5.9303870147847024e-05 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for butyl acetate input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for capacitor, electrolyte type, < 2cm height (technosphere / GLO / kilogram) Amount Not present 0.0007709503119220113 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for capacitor, electrolyte type, < 2cm height input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for capacitor, for surface-mounting (technosphere / GLO / kilogram) Amount Not present 0.00048629173521234545 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for capacitor, for surface-mounting input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for capacitor, tantalum-, for through-hole mounting (technosphere / GLO / kilogram) Amount Not present 0.00026093702865052687 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for capacitor, tantalum-, for through-hole mounting input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for electric connector, wire clamp (technosphere / GLO / kilogram) Amount Not present 0.002704256478741824 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for electric connector, wire clamp input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for switch, toggle type (technosphere / GLO / kilogram) Amount Not present 3.558232208870821e-05 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for switch, toggle type input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for light emitting diode (technosphere / GLO / kilogram) Amount Not present 2.3721548059138806e-06 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for light emitting diode input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for diode, glass-, for surface-mounting (technosphere / GLO / kilogram) Amount Not present 0.0005147575928833121 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for diode, glass-, for surface-mounting input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for electric connector, peripheral component interconnect buss (technosphere / GLO / kilogram) Amount Not present 0.005811779274489008 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for electric connector, peripheral component interconnect buss input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for inductor, miniature radio frequency chip (technosphere / GLO / kilogram) Amount Not present 4.56639800138422e-05 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for inductor, miniature radio frequency chip input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for inductor, low value multilayer chip (technosphere / GLO / kilogram) Amount Not present 2.134939325322493e-06 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for inductor, low value multilayer chip input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for inductor, ring core choke type (technosphere / GLO / kilogram) Amount Not present 0.000676064119685456 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for inductor, ring core choke type input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for integrated circuit, logic type (technosphere / GLO / kilogram) Amount Not present 0.001209798951016079 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for integrated circuit, logic type input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for integrated circuit, memory type (technosphere / GLO / kilogram) Amount Not present 4.269878650644986e-06 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for integrated circuit, memory type input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for resistor, surface-mounted (technosphere / GLO / kilogram) Amount Not present 0.00015419006238440226 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for resistor, surface-mounted input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for wafer, fabricated, for integrated circuit (technosphere / GLO / square meter) Amount Not present 7.162009790015189e-05 square meter Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for wafer, fabricated, for integrated circuit input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for transformer, low voltage use (technosphere / GLO / kilogram) Amount Not present 0.003558232208870821 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for transformer, low voltage use input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for transistor, surface-mounted (technosphere / GLO / kilogram) Amount Not present 0.00021823824214407703 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for transistor, surface-mounted input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for printed wiring board, for surface mounting, Pb free surface (technosphere / GLO / square meter) Amount Not present 0.002609370286505269 square meter Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for printed wiring board, for surface mounting, Pb free surface input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for diantimony trioxide (technosphere / RER / kilogram) Amount Not present 0.0004677488349689342 kilogram Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for diantimony trioxide input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Technosphere exchanges removed 2
Technosphere exchanges removed
Exchange / scope Field Previous value Revised value Reason
market for soft solder, Sn97Cu3 (technosphere / RER / kilogram) Amount 0.002377 kilogram Not present Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for soft solder, Sn97Cu3 input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
market for aluminium alloy, AlLi (technosphere / GLO / kilogram) Amount 0.7356 kilogram Not present Adopt the carculator_truck 0.5.2 recipe for the 2020 Regional delivery reference, replacing the earlier vehicle-model inventory consistently. Use the source recipe's market for aluminium alloy, AlLi input for this vehicle service, retaining its declared quantity, unit and supplier contract as part of the complete approved model rather than recalibrating one input independently.
Reference flows modified 1
Reference flows modified
Exchange / scope Field Previous value Revised value Reason
power electronics, for lorry (production / RER / kilogram) Database lci-long_haul_trucks Not set Retain the declared transport service/reference output while aligning its label and identifiers with the adopted vehicle recipe.
Linked database record lci-trucks / 0dc63d0a6da628a280e6c94f42116920 Not set
Tag powertrain Not set
Metadata changes 21
Metadata changes
Exchange / scope Field Previous value Revised value Reason
Inventory file Model Not set carculator_truck Documents the refreshed vehicle model, its publication, generation provenance and modelling assumptions. Historical model notes remain as inactive provenance.
Inventory file Model publication Not set Sacchi, R., Bauer, C., Cox, B. L. (2021). Does Size Matter? The Influence of Size, Load Factor, Range Autonomy, and Application Type on the Life Cycle Assessment of Current and Future Medium- and Heavy-Duty Vehicles. Environmental Science & Technology 55(8), 5224-5235. https://doi.org/10.1021/acs.est.0c07773
Inventory file Model version Not set 0.5.2
Inventory file Vehicle inventory provenance Not set {"schema version": 1, "family": "truck", "original model": "carculator_truck", "model publication": "Sacchi, R., Bauer, C., Cox, B. L. (2021). Does Size Matter? The Influence of Size, Load Factor, Range Autonomy, and Application Type on the Life Cycle Assessment of Current and Future Medium- and Heavy-Duty Vehicles. Environmental Science & Technology 55(8), 5224-5235. https://doi.org/10.1021/acs.est.0c07773", "model generation date": "2026-10-14", "libraries": {"carculator_truck": {"version": "0.5.2", "recorded git revision": "4d28ac63a31057dec6879c863370eacae52b1c18"}, "carculator_utils": {"version": "1.3.7", "recorded git revision": "d5479554cbb27ee0be6d11858c9d80697f55a4d6"}}, "source revision boundary": "Recorded repository HEADs; file hashes identify the actual generation sources, including any uncommitted changes.", "source file sha256": {"carculator_truck/carculator_truck/model.py": "9f9d40b6041f5c2673d9beaac509b3efb78a3d52b8474d15ec07e2b42f2d8f72", "carculator_truck/carculator_truck/hybrid_battery.py": "fa91dbc33b1e4374324e5c8166aef11694802ab80e14092518562b5d4e309239", "carculator_truck/carculator_truck/fuel_cell_battery.py": "a2ea3530efd9aba26e6ff84f82e017a3a31f0fc02f47ce5da585b479c21feefa", "carculator_truck/carculator_truck/inventory.py": "071259a94158ae2af32c2690fd8be5182a0256e5cf4edeb3b9e68bbb60fc1d25", "carculator_truck/carculator_truck/data/extra_parameters.json": "466e5826240594c527b1b3e5123b9f4edc1a730fa1f7aef42b26423f16e641ac", "carculator_truck/carculator_truck/data/default_parameters.json": "a1da127f70f6c8eeed62e0c284356a04148e1a24f858b7af3aaba6cf698fbc4e", "carculator_truck/carculator_truck/data/payloads.yaml": "3e08a544e63a48f1a7af2d00b48d44136cbc5b94297344ab9db1bd80ce37b5bb", "carculator_utils/carculator_utils/hot_emissions.py": "f6c0ad5b23ecadbbd70b7680c462fa5ae689456852bc34e377bd192f7fc57e0f", "carculator_utils/carculator_utils/model.py": "105b6465c7008de25994b04945049e1f91f00cf0a49495d82de5362670300b48", "carculator_utils/carculator_utils/energy_consumption.py": "92f955dfcd14d5a8733500d92c8477e1b60e59e0d244ec16409d79f417fab19f", "carculator_utils/dev/regenerate_premise_trucks.py": "f20d31702e910521538a01ca9182e47a1830065ac539ebd10cae080a8592baa9", "carculator_utils/dev/premise_vehicle_battery_metadata.py": "dffd9125283ebfad536aef53520ad25cd5a50465a355d3144f32cf055e5e515b"}, "artifacts": {"raw.json": {"sha256": "34246b8a7b0e5d8a585278299be05e73b3e59da511b93cf57b6026ce13685e18"}, "model_parameters.json": {"sha256": "13462ca8a318f8c9ada1effd66f0695f3aeae1b5548b28d2c6f088c7c2090333"}, "vehicle_parameters.csv": {"sha256": "4edc35daff2c0c2609d6bdac5311a88238350e3dd0a00138a1730d4821e1206f"}, "noise_audit.csv": {"sha256": "2d0d601d9d6902e6cfc399c8651e31ff28ce54f7f55719b53c0172ec3691a050"}}, "baseline year": 2020, "climate": "CH; Swiss annual-average thermal-demand assumptions", "driving cycle": "Regional delivery", "noise boundary": "Direct noise flows omitted from Premise imports; retained in noise_audit.csv identified by SHA-256.", "FCEV battery profile": {"profile": {"nominal_kwh": 25.0, "pack_kg": 238.0, "charge_kw": 36.0, "discharge_kw": 50.0, "discharge_10s_kw": 150.0, "cell_mass_share": 0.7}, "source": "AKASOL AKASYSTEM 15 OEM 37 PRC, May 2021 manufacturer specification, explicit proxy for 2020 FCEV trucks: 25 kWh, 238 kg, 36 kW continuous charge, 50 kW continuous RMS discharge, 150 kW discharge for 10 s. https://www.act-news.com/wp-content/uploads/2020/11/210525_LowRes_AK_Datenblatt_AKASystem_15-OEM-37-PRC_2021_2159x2794mm_EN.pdf", "power_boundary": "Continuous charging cap after direct auxiliary use; instantaneous cycle discharge bounded by the continuous RMS rating, without repeated pulse assumptions. Rated motor buffer also bounded by the 10-second discharge rating.", "sizing": "Maximum of inherited 20 kWh + 6% H2 energy floor, cycle continuous-discharge requirement and rated short-pulse requirement. Explicit capacity retained and validated.", "mass_boundary": "Complete pack 238 kg per 25 kWh; 70% cell allocation and NMC-622 manufacture are retained proxies, not measured AKASOL cell specifications.", "limits": "Conditioned-pack proxy; no electrothermal, ageing, SOC-window or fuel-cell ramp validation. Generic chemistry costs and replacement assumptions retained.", "lca_proxy": "MIX capacity market per nominal kWh including replacements; physical mass mismatch documented without mass-equivalence correction.", "future_hardware": "Premise retains the regenerated 2020 FCEV hardware; no runtime cycle simulation.", "approved_on": "2026-10-14"}, "role": "bundled component", "metadata updated": "2026-10-14", "baseline identity": {"name": "power electronics, for lorry, carculator regional truck 2020", "reference product": "power electronics, for lorry", "location": "RER", "unit": "kilogram"}, "component source boundary": "Bundled component recipe exported with the model; model year and climate do not date or parameterize this component. Its literature source is recorded separately.", "activity source": "Wolff et al. 2020, Sustainability, DOI: 10.3390/su12135396"}
Version metadata Commercial maturity stage early_commercial mature_commercial No explanation was recorded for this change.
Version metadata Inventory evidence types Literature Literature; Engineering estimate
Version metadata Geographical representativeness 2 3
Version metadata Methodology and allocation explanation Wolff2020 supplies scalable European heavy-duty tractor component-production inventories from material manufacture through final assembly; vehicle use, fuel supply and end-of-life are excluded. Source software/background are GaBi with ecoinvent3.3/thinkstep6.115(2017), not a replacement for CLIC's profiles. Secondary data, mass models and expert interviews are used;2020 publication does not date every input. This node has reference1kilogram of power electronics, for lorry; retain source component normalization, CLIC supplier/process proxies and later corrections separately. Model provenance
The primary Chalmers model/report release is from 2018; 2016:5 is a report identifier rather than a measurement year. Associated papers were online in 2018 and issued in 2019. Wolff is an antecedent transfer rather than primary author of the reconstruction. Current copper, machining/rolling and output-normalization corrections retain the v1.01 basis and declared 3.8 profile. Chalmers Energy support belongs to the source study, not automatically Wolff/TUM or CLIC.
Version metadata Publication / citation Wolff, S., Seidenfus, M., Gordon, K., Álvarez, S., Kalt, S., Lienkamp, M. (2020). Scalable Life-Cycle Inventory for Heavy-Duty Vehicle Production. Sustainability12(13),5396. https://doi.org/10.3390/su12135396 Nordelöf, A. (2018). Scalable Power Electronic Inverter LCI model, version 1.01. Chalmers University of Technology; CPM LCA Database. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Version metadata Publication DOI 10.3390/su12135396 Not set
Version metadata Source Wolff, S., Seidenfus, M., Gordon, K., Álvarez, S., Kalt, S., Lienkamp, M. (2020). Scalable Life-Cycle Inventory for Heavy-Duty Vehicle Production. Sustainability12(13),5396. https://doi.org/10.3390/su12135396 Nordelöf, A. (2018). Scalable Power Electronic Inverter LCI model, version 1.01. Chalmers University of Technology; CPM LCA Database. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Version metadata Source type scientific_journal data_repository
Version metadata Contributors, publications, projects and supporting evidence Funding: 1. Project: Url: https://doi.org/10.3390/su12135396
Funding: 1. Project: Name: Wolff et al.(2020) scalable heavy-duty vehicle production source study
Funding: 1. Project: Acronym: Not set
Funding: 1. Project: Relation: source_study
Funding: 1. Project: Grant identifier: Not set
Funding: 1. Organization: Ror: https://ror.org/02kkvpp62
Funding: 1. Organization: Url: https://www.tum.de/
Funding: 1. Organization: Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Funding: 1. Award identifier: Not set
Evidence: 1. Origin: source_import
Evidence: 1. Target field: publications
Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: editor_verification
Evidence: 2. Target field: publications
Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 2. Source reference: https://api.crossref.org/works/10.3390%2Fsu12135396
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: technology_description
Evidence: 4. Qualification: Only this supplied activity is described; whole-paper life-cycle boundaries not copied onto components.
Evidence: 4. Source location: description
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: editor_verification
Evidence: 5. Target field: publications
Evidence: 5. Qualification: Six2020authors at TUM. Paper defines truck component inventories, not regional rail operation. Historical affiliations and inventory contributors remain separate.
Evidence: 5. Source location: Publisher XML/PDF byline, affiliations and ORCIDs; explicit source-role review
Evidence: 5. Source reference: https://doi.org/10.3390/su12135396
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: methodology_notes
Evidence: 6. Qualification: Wolff2020 supplies scalable European heavy-duty tractor component-production inventories from material manufacture through final assembly; vehicle use, fuel supply and end-of-life are excluded. Source software/background are GaBi with ecoinvent3.3/thinkstep6.115(2017), not a replacement for CLIC's profiles. Secondary data, mass models and expert interviews are used;2020 publication does not date every input. This node has reference1kilogram of power electronics, for lorry; retain source component normalization, CLIC supplier/process proxies and later corrections separately. Partial source comparison. Dry engine SI mass1140kg differs from printed Table4 total1206kg; native/paper definitions are retained, not blindly renormalized. Cab heat total labelledkWh adds MJ subtotals and printed TableA2 saysMJ; other heatkWh/MJ labels require ancestor verification before any3.6rescaling. Tyre acetylene differs by10between SI and printed table. Natural-gas mass/volume conversion requires reference conditions. Source power-electronics sheet has detailed materials/processing but no declared total normalization; do not sum process solvents into a finished-device mass without justification. No formal Wolff erratum found in scoped checks. Publisher HTML/PDF update dates alone do not establish inventory corrections. Hawkins2013 corrigendum changes EV motor/inverter/charger and additional battery packaging; applicability must be traced to each reused component, not applied across every glider or rail process.
Evidence: 6. Source location: Published main/SI member/cell quantities and exact CLIC references
Evidence: 6. Source reference: https://doi.org/10.3390/su12135396
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: funding
Evidence: 7. Qualification: TUM Institute of Automotive Technology basic research support of Wolff source study; no grant/industry sponsor or CLIC regional-rail/inventory-development funding inferred.
Evidence: 7. Source location: Published funding statement
Evidence: 7. Source reference: https://doi.org/10.3390/su12135396
Projects: 1. Url: https://doi.org/10.3390/su12135396
Projects: 1. Name: Wolff et al.(2020) scalable heavy-duty vehicle production source study
Projects: 1. Acronym: Not set
Projects: 1. Relation: source_study
Projects: 1. Grant identifier: Not set
Publications: 1. Doi: 10.3390/su12135396
Publications: 1. Url: https://doi.org/10.3390/su12135396
Publications: 1. Title: Scalable Life-Cycle Inventory for Heavy-Duty Vehicle Production
Publications: 1. Scientific authors: 1. Name: Sebastian Wolff
Publications: 1. Scientific authors: 1. Orcid: 0000-0001-6937-3313
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.tum.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 1. Scientific authors: 2. Name: Moritz Seidenfus
Publications: 1. Scientific authors: 2. Orcid: Not set
Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.tum.de/
Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 1. Scientific authors: 3. Name: Karim Gordon
Publications: 1. Scientific authors: 3. Orcid: Not set
Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 1. Scientific authors: 3. Affiliations: 1. Url: https://www.tum.de/
Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 1. Scientific authors: 4. Name: Sergio Álvarez
Publications: 1. Scientific authors: 4. Orcid: Not set
Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.tum.de/
Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 1. Scientific authors: 5. Name: Svenja Kalt
Publications: 1. Scientific authors: 5. Orcid: 0000-0002-4261-8517
Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.tum.de/
Publications: 1. Scientific authors: 5. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 1. Scientific authors: 6. Name: Markus Lienkamp
Publications: 1. Scientific authors: 6. Orcid: Not set
Publications: 1. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 1. Scientific authors: 6. Affiliations: 1. Url: https://www.tum.de/
Publications: 1. Scientific authors: 6. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 1. Citation: Wolff, S., Seidenfus, M., Gordon, K., Álvarez, S., Kalt, S., Lienkamp, M. (2020). Scalable Life-Cycle Inventory for Heavy-Duty Vehicle Production. Sustainability12(13),5396. https://doi.org/10.3390/su12135396
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2020
Funding: 1. Project: Url: https://doi.org/10.3390/su12135396
Funding: 1. Project: Name: Wolff et al.(2020) scalable heavy-duty vehicle production source study
Funding: 1. Project: Acronym: Not set
Funding: 1. Project: Relation: source_study
Funding: 1. Project: Grant identifier: Not set
Funding: 1. Organization: Ror: https://ror.org/02kkvpp62
Funding: 1. Organization: Url: https://www.tum.de/
Funding: 1. Organization: Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Funding: 1. Award identifier: Not set
Funding: 2. Project: Url: https://doi.org/10.1007/s11367-018-1503-3
Funding: 2. Project: Name: Scalable automotive inverter LCI model source study
Funding: 2. Project: Acronym: Not set
Funding: 2. Project: Relation: source_study
Funding: 2. Project: Grant identifier: Not set
Funding: 2. Organization: Ror: https://ror.org/040wg7k59
Funding: 2. Organization: Url: https://www.chalmers.se/
Funding: 2. Organization: Name: Area of Advance Energy, Chalmers University of Technology
Funding: 2. Award identifier: Not set
Evidence: 1. Origin: source_import
Evidence: 1. Target field: publications
Evidence: 1. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: editor_verification
Evidence: 2. Target field: publications
Evidence: 2. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 2. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 2. Source reference: https://api.crossref.org/works/10.3390%2Fsu12135396
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: data_origins
Evidence: 4. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 4. Source location: description
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: technology_description
Evidence: 5. Qualification: Only this supplied activity is described; whole-paper life-cycle boundaries not copied onto components.
Evidence: 5. Source location: description
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Six2020authors at TUM. Paper defines truck component inventories, not regional rail operation. Historical affiliations and inventory contributors remain separate.
Evidence: 6. Source location: Publisher XML/PDF byline, affiliations and ORCIDs; explicit source-role review
Evidence: 6. Source reference: https://doi.org/10.3390/su12135396
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: methodology_notes
Evidence: 7. Qualification: Wolff2020 supplies scalable European heavy-duty tractor component-production inventories from material manufacture through final assembly; vehicle use, fuel supply and end-of-life are excluded. Source software/background are GaBi with ecoinvent3.3/thinkstep6.115(2017), not a replacement for CLIC's profiles. Secondary data, mass models and expert interviews are used;2020 publication does not date every input. This node has reference1kilogram of power electronics, for lorry; retain source component normalization, CLIC supplier/process proxies and later corrections separately. Partial source comparison. Dry engine SI mass1140kg differs from printed Table4 total1206kg; native/paper definitions are retained, not blindly renormalized. Cab heat total labelledkWh adds MJ subtotals and printed TableA2 saysMJ; other heatkWh/MJ labels require ancestor verification before any3.6rescaling. Tyre acetylene differs by10between SI and printed table. Natural-gas mass/volume conversion requires reference conditions. Source power-electronics sheet has detailed materials/processing but no declared total normalization; do not sum process solvents into a finished-device mass without justification. No formal Wolff erratum found in scoped checks. Publisher HTML/PDF update dates alone do not establish inventory corrections. Hawkins2013 corrigendum changes EV motor/inverter/charger and additional battery packaging; applicability must be traced to each reused component, not applied across every glider or rail process.
Evidence: 7. Source location: Published main/SI member/cell quantities and exact CLIC references
Evidence: 7. Source reference: https://doi.org/10.3390/su12135396
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: funding
Evidence: 8. Qualification: TUM Institute of Automotive Technology basic research support of Wolff source study; no grant/industry sponsor or CLIC regional-rail/inventory-development funding inferred.
Evidence: 8. Source location: Published funding statement
Evidence: 8. Source reference: https://doi.org/10.3390/su12135396
Evidence: 9. Origin: editor_verification
Evidence: 9. Target field: publications
Evidence: 9. Qualification: Current version 5527 adopts the30 kW/400 V/air-cooled Nordelöf v1.01 model normalized by 8.431152954326238kg finished output. Wolff (2020) is an antecedent transfer, not the primary author of the reconstructed recipe. Chalmers model/report release year 2018 is not an inventory measurement period; 2016:5 is a report identifier. Preserve the native 3.8 profile and declared material, processing, oxide and supplier proxies. Wolff-study institutional support does not establish funding of the Nordelöf model or CLIC. Report v1.01 records revisions to chapters 4/5 and added Appendix C; three checked coefficients match this release, not a complete 1.0-to-1.01 change audit.
Evidence: 9. Source location: Model v1.01 Summary B23/G23/O23/Q23/M58/G149/G150 and mass configuration L89; report cover and revision history p.iv
Evidence: 9. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 10. Origin: editor_verification
Evidence: 10. Target field: publications
Evidence: 10. Qualification: Associated inverter journal papers were online in2018 and issued in2019; the primary model and technical report remain2018. Nordelöf's ORCID is publisher-confirmed. Both papers acknowledge Chalmers Area of Advance Energy support for that source study. Preserve the funding unit under the canonical Chalmers parent, separate from antecedent Wolff/TUM support and CLIC contributors. No grant number or CLIC funding is inferred. Exact Crossmark records currently report Document is current; this scoped journal check does not supersede the model report's positive v1.01 revision history or prove absence of all amendments.
Evidence: 10. Source location: Both publisher bylines, affiliations, acknowledgements, citation dates and exact Crossmark records checked2026-11-06
Evidence: 10. Source reference: https://doi.org/10.1007/s11367-018-1503-3
Evidence: 11. Origin: editor_verification
Evidence: 11. Target field: technology_description
Evidence: 11. Qualification: Technical-characterisation review TC-2977. Design capacity: Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 11. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 11. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 12. Origin: editor_verification
Evidence: 12. Target field: technology_description
Evidence: 12. Qualification: Technical-characterisation review TC-2977. Design capacity unit: Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 12. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 12. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 13. Origin: editor_verification
Evidence: 13. Target field: technology_description
Evidence: 13. Qualification: Technical-characterisation review TC-2977. Capacity factor (%): Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 13. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 13. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 14. Origin: editor_verification
Evidence: 14. Target field: technology_description
Evidence: 14. Qualification: Technical-characterisation review TC-2977. Annual production volume: Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 14. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 14. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 15. Origin: editor_verification
Evidence: 15. Target field: technology_description
Evidence: 15. Qualification: Technical-characterisation review TC-2977. Annual production volume unit: Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 15. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 15. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 16. Origin: editor_verification
Evidence: 16. Target field: technology_description
Evidence: 16. Qualification: Technical-characterisation review TC-2977. Annual production volume year: Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 16. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 16. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 17. Origin: editor_verification
Evidence: 17. Target field: technology_description
Evidence: 17. Qualification: Technical-characterisation review TC-2977. Plant or represented-asset lifetime (years): Unspecified. Basis: Own1 kg component-production reference has no configured manufacturing plant/output schedule. Source device ratings, mass/scaling laws, vehicle payload/life and embedded parent FCEV battery profile are not own production capacity, annual output, utilization or equipment life. Keep all own numeric fields unspecified. Reference inverter is 30 kW AC output, 400 V DC input, air cooled, finished mass 8.431152954326238 kg; these device properties are not capacity of the one-kg manufacturing reference. Public scalability 20–200 kW and 250–700 V does not demonstrate every truck installation. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 17. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 17. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 18. Origin: editor_verification
Evidence: 18. Target field: technology_description
Evidence: 18. Qualification: Technical-characterisation review TC-2977. Commercial maturity stage: mature_commercial. Basis: Use mature-commercial/9 as curator assessments of established IGBT inverter manufacturing class, not a source-assigned numerical TRL or certification of this adapted lorry recipe. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 18. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 18. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 19. Origin: editor_verification
Evidence: 19. Target field: technology_description
Evidence: 19. Qualification: Technical-characterisation review TC-2977. Technology readiness level: 9. Basis: Use mature-commercial/9 as curator assessments of established IGBT inverter manufacturing class, not a source-assigned numerical TRL or certification of this adapted lorry recipe. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 19. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 19. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 20. Origin: editor_verification
Evidence: 20. Target field: technology_description
Evidence: 20. Qualification: Technical-characterisation review TC-2977. Technological representativeness: 4. Basis: Curator technology/geography/time 4/3/4 for adapted vehicle scaling, supplier proxies and historical general model. No operating life or factory observation date recovered. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 20. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 20. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 21. Origin: editor_verification
Evidence: 21. Target field: technology_description
Evidence: 21. Qualification: Technical-characterisation review TC-2977. Geographical representativeness: 3. Basis: Curator technology/geography/time 4/3/4 for adapted vehicle scaling, supplier proxies and historical general model. No operating life or factory observation date recovered. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 21. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 21. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Evidence: 22. Origin: editor_verification
Evidence: 22. Target field: technology_description
Evidence: 22. Qualification: Technical-characterisation review TC-2977. Temporal representativeness: 4. Basis: Curator technology/geography/time 4/3/4 for adapted vehicle scaling, supplier proxies and historical general model. No operating life or factory observation date recovered. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 22. Source location: Nordelof model v1.01 Summary B23/G23/O23/Q23 and Mass configuration L89; public CPM technical-system and boundary description
Evidence: 22. Source reference: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Projects: 1. Url: https://doi.org/10.3390/su12135396
Projects: 1. Name: Wolff et al.(2020) scalable heavy-duty vehicle production source study
Projects: 1. Acronym: Not set
Projects: 1. Relation: source_study
Projects: 1. Grant identifier: Not set
Projects: 2. Url: https://doi.org/10.1007/s11367-018-1503-3
Projects: 2. Name: Scalable automotive inverter LCI model source study
Projects: 2. Acronym: Not set
Projects: 2. Relation: source_study
Projects: 2. Grant identifier: Not set
Publications: 1. Doi: Not set
Publications: 1. Url: https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Publications: 1. Title: Scalable Power Electronic Inverter LCI model, version 1.01
Publications: 1. Scientific authors: 1. Name: Anders Nordelöf
Publications: 1. Scientific authors: 1. Orcid: 0000-0002-7455-7341
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Division of Environmental Systems Analysis, Chalmers University of Technology, Gothenburg, Sweden
Publications: 1. Citation: Nordelöf, A. (2018). Scalable Power Electronic Inverter LCI model, version 1.01. Chalmers University of Technology; CPM LCA Database. https://cpmdatabase.cpm.chalmers.se/Scripts/sheet.asp?ActId=JT-2017-06-26-43
Publications: 1. Relation: primary_source
Publications: 1. Source type: data_repository
Publications: 1. Publication year: 2018
Publications: 2. Doi: Not set
Publications: 2. Url: https://cpmdatabase.cpm.chalmers.se/DataReferences/LCI%20model%20report%20inverter%20unit%20v1.01_Final.pdf
Publications: 2. Title: A Scalable Life Cycle Inventory of an Automotive Power Electronic Inverter Unit: Technical and Methodological Description, version 1.01
Publications: 2. Scientific authors: 1. Name: Anders Nordelöf
Publications: 2. Scientific authors: 1. Orcid: 0000-0002-7455-7341
Publications: 2. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 2. Scientific authors: 1. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 2. Scientific authors: 1. Affiliations: 1. Name: Division of Environmental Systems Analysis, Chalmers University of Technology, Gothenburg, Sweden
Publications: 2. Scientific authors: 2. Name: Mikael Alatalo
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 2. Scientific authors: 2. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 2. Scientific authors: 2. Affiliations: 1. Name: Division of Electric Power Engineering, Chalmers University of Technology, Gothenburg, Sweden
Publications: 2. Citation: Nordelöf, A., Alatalo, M. (2018). A Scalable Life Cycle Inventory of an Automotive Power Electronic Inverter Unit. Technical and Methodological Description, version 1.01. ESA report 2016:5(1.01), Chalmers University of Technology. https://cpmdatabase.cpm.chalmers.se/DataReferences/LCI%20model%20report%20inverter%20unit%20v1.01_Final.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Publications: 3. Doi: 10.3390/su12135396
Publications: 3. Url: https://doi.org/10.3390/su12135396
Publications: 3. Title: Scalable Life-Cycle Inventory for Heavy-Duty Vehicle Production
Publications: 3. Scientific authors: 1. Name: Sebastian Wolff
Publications: 3. Scientific authors: 1. Orcid: 0000-0001-6937-3313
Publications: 3. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 3. Scientific authors: 1. Affiliations: 1. Url: https://www.tum.de/
Publications: 3. Scientific authors: 1. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 3. Scientific authors: 2. Name: Moritz Seidenfus
Publications: 3. Scientific authors: 2. Orcid: Not set
Publications: 3. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 3. Scientific authors: 2. Affiliations: 1. Url: https://www.tum.de/
Publications: 3. Scientific authors: 2. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 3. Scientific authors: 3. Name: Karim Gordon
Publications: 3. Scientific authors: 3. Orcid: Not set
Publications: 3. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 3. Scientific authors: 3. Affiliations: 1. Url: https://www.tum.de/
Publications: 3. Scientific authors: 3. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 3. Scientific authors: 4. Name: Sergio Álvarez
Publications: 3. Scientific authors: 4. Orcid: Not set
Publications: 3. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 3. Scientific authors: 4. Affiliations: 1. Url: https://www.tum.de/
Publications: 3. Scientific authors: 4. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 3. Scientific authors: 5. Name: Svenja Kalt
Publications: 3. Scientific authors: 5. Orcid: 0000-0002-4261-8517
Publications: 3. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 3. Scientific authors: 5. Affiliations: 1. Url: https://www.tum.de/
Publications: 3. Scientific authors: 5. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 3. Scientific authors: 6. Name: Markus Lienkamp
Publications: 3. Scientific authors: 6. Orcid: Not set
Publications: 3. Scientific authors: 6. Affiliations: 1. Ror: https://ror.org/02kkvpp62
Publications: 3. Scientific authors: 6. Affiliations: 1. Url: https://www.tum.de/
Publications: 3. Scientific authors: 6. Affiliations: 1. Name: Institute of Automotive Technology, Technical University of Munich, Boltzmannstraße15,85748Munich,Germany
Publications: 3. Citation: Wolff, S., Seidenfus, M., Gordon, K., Álvarez, S., Kalt, S., Lienkamp, M. (2020). Scalable Life-Cycle Inventory for Heavy-Duty Vehicle Production. Sustainability12(13),5396. https://doi.org/10.3390/su12135396
Publications: 3. Relation: supporting_source
Publications: 3. Source type: scientific_journal
Publications: 3. Publication year: 2020
Publications: 4. Doi: 10.1007/s11367-018-1503-3
Publications: 4. Url: https://doi.org/10.1007/s11367-018-1503-3
Publications: 4. Title: A scalable life cycle inventory of an automotive power electronic inverter unit—part I: design and composition
Publications: 4. Scientific authors: 1. Name: Anders Nordelöf
Publications: 4. Scientific authors: 1. Orcid: 0000-0002-7455-7341
Publications: 4. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 4. Scientific authors: 1. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 4. Scientific authors: 1. Affiliations: 1. Name: Division of Environmental Systems Analysis, Chalmers University of Technology, Gothenburg, Sweden
Publications: 4. Scientific authors: 2. Name: Mikael Alatalo
Publications: 4. Scientific authors: 2. Orcid: Not set
Publications: 4. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 4. Scientific authors: 2. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 4. Scientific authors: 2. Affiliations: 1. Name: Division of Electric Power Engineering, Chalmers University of Technology, Gothenburg, Sweden
Publications: 4. Scientific authors: 3. Name: Maria Ljunggren Söderman
Publications: 4. Scientific authors: 3. Orcid: Not set
Publications: 4. Scientific authors: 3. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 4. Scientific authors: 3. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 4. Scientific authors: 3. Affiliations: 1. Name: Division of Environmental Systems Analysis, Chalmers University of Technology, Gothenburg, Sweden
Publications: 4. Citation: Nordelöf, A., Alatalo, M., Ljunggren Söderman, M. (2019). A scalable life cycle inventory of an automotive power electronic inverter unit—part I: design and composition. The International Journal of Life Cycle Assessment24, 78-92. https://doi.org/10.1007/s11367-018-1503-3
Publications: 4. Relation: supporting_source
Publications: 4. Source type: scientific_journal
Publications: 4. Publication year: 2019
Publications: 5. Doi: 10.1007/s11367-018-1491-3
Publications: 5. Url: https://doi.org/10.1007/s11367-018-1491-3
Publications: 5. Title: A scalable life cycle inventory of an automotive power electronic inverter unit—part II: manufacturing processes
Publications: 5. Scientific authors: 1. Name: Anders Nordelöf
Publications: 5. Scientific authors: 1. Orcid: 0000-0002-7455-7341
Publications: 5. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/040wg7k59
Publications: 5. Scientific authors: 1. Affiliations: 1. Url: https://www.chalmers.se/
Publications: 5. Scientific authors: 1. Affiliations: 1. Name: Division of Environmental Systems Analysis, Chalmers University of Technology, Gothenburg, Sweden
Publications: 5. Citation: Nordelöf, A. (2019). A scalable life cycle inventory of an automotive power electronic inverter unit—part II: manufacturing processes. The International Journal of Life Cycle Assessment24, 694-711. https://doi.org/10.1007/s11367-018-1491-3
Publications: 5. Relation: supporting_source
Publications: 5. Source type: scientific_journal
Publications: 5. Publication year: 2019
Version metadata System boundary Component-production reference, derived from the truck study's cradle-to-gate inventory. Linked supplier manufacturing, direct emissions and disposal/replacement overlap require separate reconciliation. The recorded finished-inverter materials/components and manufacturing services per kilogram. Use and vehicle end-of-life are outside the manufacturing node.
Version metadata Technological representativeness 2 4
Version metadata Technology description Wolff2020 supplies scalable European heavy-duty tractor component-production inventories from material manufacture through final assembly; vehicle use, fuel supply and end-of-life are excluded. Source software/background are GaBi with ecoinvent3.3/thinkstep6.115(2017), not a replacement for CLIC's profiles. Secondary data, mass models and expert interviews are used;2020 publication does not date every input. This node has reference1kilogram of power electronics, for lorry; retain source component normalization, CLIC supplier/process proxies and later corrections separately. IGBT inverter manufacture normalized by 8.431152954326238 kg finished device output, including material/components and production services.
Version metadata Technology readiness level 8 9
Version metadata Temporal representativeness 2 4
Version metadata Limitations on use Partial source comparison. Dry engine SI mass1140kg differs from printed Table4 total1206kg; native/paper definitions are retained, not blindly renormalized. Cab heat total labelledkWh adds MJ subtotals and printed TableA2 saysMJ; other heatkWh/MJ labels require ancestor verification before any3.6rescaling. Tyre acetylene differs by10between SI and printed table. Natural-gas mass/volume conversion requires reference conditions. Source power-electronics sheet has detailed materials/processing but no declared total normalization; do not sum process solvents into a finished-device mass without justification. No formal Wolff erratum found in scoped checks. Publisher HTML/PDF update dates alone do not establish inventory corrections. Hawkins2013 corrigendum changes EV motor/inverter/charger and additional battery packaging; applicability must be traced to each reused component, not applied across every glider or rail process. Design and transfer limits
Three corrected copper/processing quantities independently match v1.01; this does not validate all flows, native supplier crosswalks, oxide proxies, mass/waste closure or truck electrical fit. The report has a revision history; complete source-version and journal-amendment applicability remain unproven.
Version metadata Description This dataset represents the power electronics, for lorry used in the scalable, component-based heavy-duty vehicle inventory of Wolff et al. (2020). That study combines primary and secondary data to compare life-cycle impacts of internal-combustion, hybrid, battery-electric, and fuel-cell trucks. This activity should therefore be interpreted as a foreground vehicle-production subassembly within truck manufacture rather than as a generic standalone market dataset.

Source review: Wolff2020 supplies scalable European heavy-duty tractor component-production inventories from material manufacture through final assembly; vehicle use, fuel supply and end-of-life are excluded. Source software/background are GaBi with ecoinvent3.3/thinkstep6.115(2017), not a replacement for CLIC's profiles. Secondary data, mass models and expert interviews are used;2020 publication does not date every input. This node has reference1kilogram of power electronics, for lorry; retain source component normalization, CLIC supplier/process proxies and later corrections separately.
Production reference for 1 kg finished automotive inverter, reconstructed from the Nordelöf v1.01 model. It represents a 30 kW, 400 V DC-input, air-cooled design used here as a heavy-duty-vehicle electronics proxy. Describe the actual reference flow, process boundary, engineering assumptions and source limitations in reader-facing language. Remove operational review/release instructions and distinguish capacity/component services from operating-energy inputs; the inventory content and declared terms are preserved.
Version metadata Intended application Not set A per-mass inverter manufacturing proxy where power rating, voltage, cooling and caller boundary are checked explicitly. Apply reviewed discovery metadata and change explanations from the curated release.
Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content