Description
Production of recirculating chiller. The reference flow is one unit of recirculating chiller. It is a supporting equipment or consumable inventory for the laboratory waste-RAM recovery route.
Waste
Reference product recirculating chiller GLO
Stable dataset identity
recirculating-chiller-production
1.0.0Published inventory
Process description and catalog context. View scientific metadata
Production of recirculating chiller. The reference flow is one unit of recirculating chiller. It is a supporting equipment or consumable inventory for the laboratory waste-RAM recovery route.
Classification, keywords, bookmarks and download counts.
Classification path: Waste
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
https://doi.org/10.1016/j.jclepro.2025.147016; https://doi.org/10.5281/zenodo.17348137; LCI_equipment!A151; SHA-256 cda3a9b590afe2e570908048c1e2999f1a9ba098f0045f6312c7074344674c24
Inventory changes relative to source: Modified inventory
The published ecoinvent 3.8 APOS background is replaced by ecoinvent 3.12 cut-off. The compilation also makes the documented laboratory correction and alternative allocation views explicit; it is not a reproduction of the original APOS model.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-16 10:58 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
recirculating chiller production
GLO
|
recirculating chiller
|
1
|
unit | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
steel production, electric, chromium steel 18/8
RER
|
steel, chromium steel 18/8
|
8.4
|
kilogram |
0.172988
mol H+-Eq / unit
4.4% of total
29.2145
kg CO2-Eq / unit
20.2% of total
112.203
CTUe / unit
7.7% of total
0.0112833
kg P-Eq / unit
1.1% of total
0.0293816
kg N-Eq / unit
11.2% of total
0.313015
mol N-Eq / unit
11.2% of total
6.1508e-07
CTUh / unit
47.8% of total
3.2235e-06
CTUh / unit
5.6% of total
7.29889
kBq U235-Eq / unit
15.4% of total
145.509
dimensionless / unit
17.3% of total
4.3130e-07
kg CFC-11-Eq / unit
7.8% of total
2.3470e-06
disease incidence / unit
18.8% of total
0.0994918
kg NMVOC-Eq / unit
11.1% of total
386.965
MJ, net calorific value / unit
15.7% of total
0.00101902
kg Sb-Eq / unit
8.0% of total
7.84189
m3 world Eq deprived / unit
1.8% of total
BAFU:2025
|
|
|
treatment of aluminium scrap, new, at refiner
RER
|
aluminium, cast alloy
|
7
|
kilogram |
0.000656292
mol H+-Eq / unit
0.0% of total
0.155677
kg CO2-Eq / unit
0.1% of total
0.437973
CTUe / unit
0.0% of total
2.6730e-05
kg P-Eq / unit
0.0% of total
0.000261828
kg N-Eq / unit
0.1% of total
0.00270816
mol N-Eq / unit
0.1% of total
7.4653e-11
CTUh / unit
0.0% of total
1.3248e-09
CTUh / unit
0.0% of total
0.0382352
kBq U235-Eq / unit
0.1% of total
1.21462
dimensionless / unit
0.1% of total
5.4925e-09
kg CFC-11-Eq / unit
0.1% of total
5.1422e-09
disease incidence / unit
0.0% of total
0.00095372
kg NMVOC-Eq / unit
0.1% of total
2.36984
MJ, net calorific value / unit
0.1% of total
3.6242e-07
kg Sb-Eq / unit
0.0% of total
0.166627
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
polyethylene production, high density, granulate
RER
|
polyethylene, high density, granulate
|
5.6
|
kilogram |
0.0302184
mol H+-Eq / unit
0.8% of total
12.712
kg CO2-Eq / unit
8.8% of total
75.7357
CTUe / unit
5.2% of total
0.00070722
kg P-Eq / unit
0.1% of total
0.0067333
kg N-Eq / unit
2.6% of total
0.0737592
mol N-Eq / unit
2.6% of total
1.8203e-09
CTUh / unit
0.1% of total
4.8144e-08
CTUh / unit
0.1% of total
0.457124
kBq U235-Eq / unit
1.0% of total
5.2622
dimensionless / unit
0.6% of total
3.5662e-07
kg CFC-11-Eq / unit
6.5% of total
3.8019e-07
disease incidence / unit
3.0% of total
0.0322355
kg NMVOC-Eq / unit
3.6% of total
393.233
MJ, net calorific value / unit
16.0% of total
1.9210e-05
kg Sb-Eq / unit
0.2% of total
73.8064
m3 world Eq deprived / unit
17.2% of total
BAFU:2025
|
|
|
electrorefining of copper, anode
GLO
|
copper, cathode
|
2.8
|
kilogram |
1.71492
mol H+-Eq / unit
43.3% of total
7.52689
kg CO2-Eq / unit
5.2% of total
477.654
CTUe / unit
32.7% of total
0.491625
kg P-Eq / unit
47.9% of total
0.0788806
kg N-Eq / unit
30.2% of total
0.897778
mol N-Eq / unit
32.2% of total
2.7514e-07
CTUh / unit
21.4% of total
2.6228e-05
CTUh / unit
45.8% of total
2.40768
kBq U235-Eq / unit
5.1% of total
194.48
dimensionless / unit
23.1% of total
1.9037e-07
kg CFC-11-Eq / unit
3.4% of total
2.9283e-06
disease incidence / unit
23.4% of total
0.264677
kg NMVOC-Eq / unit
29.5% of total
103.69
MJ, net calorific value / unit
4.2% of total
0.00567205
kg Sb-Eq / unit
44.4% of total
8.14149
m3 world Eq deprived / unit
1.9% of total
BAFU:2025
|
|
|
electronics production, for control units
RER
|
electronics, for control units
|
4.2
|
kilogram |
0.753229
mol H+-Eq / unit
19.0% of total
77.8491
kg CO2-Eq / unit
53.7% of total
626.282
CTUe / unit
42.9% of total
0.340986
kg P-Eq / unit
33.2% of total
0.0975759
kg N-Eq / unit
37.3% of total
1.00367
mol N-Eq / unit
36.1% of total
1.5703e-07
CTUh / unit
12.2% of total
7.8726e-06
CTUh / unit
13.8% of total
16.3402
kBq U235-Eq / unit
34.5% of total
553.472
dimensionless / unit
65.8% of total
6.5305e-06
kg CFC-11-Eq / unit
118.1% of total
3.3289e-06
disease incidence / unit
26.6% of total
0.329981
kg NMVOC-Eq / unit
36.8% of total
1064.35
MJ, net calorific value / unit
43.2% of total
0.0448238
kg Sb-Eq / unit
351.2% of total
592.041
m3 world Eq deprived / unit
137.8% of total
BAFU:2025
|
|
|
impact extrusion of steel, cold, 3 strokes
RER
|
impact extrusion of steel, cold, 3 strokes
|
8.4
|
kilogram |
0.0146452
mol H+-Eq / unit
0.4% of total
7.5233
kg CO2-Eq / unit
5.2% of total
34.2268
CTUe / unit
2.3% of total
0.00231946
kg P-Eq / unit
0.2% of total
0.00523227
kg N-Eq / unit
2.0% of total
0.0373377
mol N-Eq / unit
1.3% of total
3.2272e-09
CTUh / unit
0.3% of total
5.1253e-08
CTUh / unit
0.1% of total
2.76546
kBq U235-Eq / unit
5.8% of total
60.9844
dimensionless / unit
7.3% of total
1.7691e-07
kg CFC-11-Eq / unit
3.2% of total
1.0420e-07
disease incidence / unit
0.8% of total
0.0143173
kg NMVOC-Eq / unit
1.6% of total
112.47
MJ, net calorific value / unit
4.6% of total
1.3374e-05
kg Sb-Eq / unit
0.1% of total
6.11313
m3 world Eq deprived / unit
1.4% of total
BAFU:2025
|
|
|
impact extrusion of aluminium, 3 strokes
RER
|
impact extrusion of aluminium, 3 strokes
|
7
|
kilogram |
0.0195581
mol H+-Eq / unit
0.5% of total
7.21257
kg CO2-Eq / unit
5.0% of total
32.7046
CTUe / unit
2.2% of total
0.0043083
kg P-Eq / unit
0.4% of total
0.00557395
kg N-Eq / unit
2.1% of total
0.0399003
mol N-Eq / unit
1.4% of total
5.0060e-09
CTUh / unit
0.4% of total
6.5857e-08
CTUh / unit
0.1% of total
5.57038
kBq U235-Eq / unit
11.7% of total
67.7873
dimensionless / unit
8.1% of total
1.7298e-07
kg CFC-11-Eq / unit
3.1% of total
1.2814e-07
disease incidence / unit
1.0% of total
0.0131032
kg NMVOC-Eq / unit
1.5% of total
130.051
MJ, net calorific value / unit
5.3% of total
2.0794e-05
kg Sb-Eq / unit
0.2% of total
5.94297
m3 world Eq deprived / unit
1.4% of total
BAFU:2025
|
|
|
injection moulding
RER
|
injection moulding
|
5.6
|
kilogram |
0.014977
mol H+-Eq / unit
0.4% of total
5.7032
kg CO2-Eq / unit
3.9% of total
19.4257
CTUe / unit
1.3% of total
0.00223017
kg P-Eq / unit
0.2% of total
0.0031716
kg N-Eq / unit
1.2% of total
0.0300986
mol N-Eq / unit
1.1% of total
3.9822e-09
CTUh / unit
0.3% of total
3.1759e-08
CTUh / unit
0.1% of total
3.20143
kBq U235-Eq / unit
6.8% of total
47.911
dimensionless / unit
5.7% of total
2.8027e-06
kg CFC-11-Eq / unit
50.7% of total
1.1871e-07
disease incidence / unit
0.9% of total
0.0125064
kg NMVOC-Eq / unit
1.4% of total
113.469
MJ, net calorific value / unit
4.6% of total
8.1566e-06
kg Sb-Eq / unit
0.1% of total
2.47623
m3 world Eq deprived / unit
0.6% of total
BAFU:2025
|
|
|
wire drawing, copper
RER
|
wire drawing, copper
|
2.8
|
kilogram |
0.0190855
mol H+-Eq / unit
0.5% of total
1.04555
kg CO2-Eq / unit
0.7% of total
7.56028
CTUe / unit
0.5% of total
0.00613921
kg P-Eq / unit
0.6% of total
0.00159795
kg N-Eq / unit
0.6% of total
0.0176405
mol N-Eq / unit
0.6% of total
2.9420e-09
CTUh / unit
0.2% of total
2.2222e-07
CTUh / unit
0.4% of total
0.528523
kBq U235-Eq / unit
1.1% of total
6.44445
dimensionless / unit
0.8% of total
2.6159e-08
kg CFC-11-Eq / unit
0.5% of total
5.1036e-08
disease incidence / unit
0.4% of total
0.00771092
kg NMVOC-Eq / unit
0.9% of total
17.8409
MJ, net calorific value / unit
0.7% of total
0.000127536
kg Sb-Eq / unit
1.0% of total
0.44636
m3 world Eq deprived / unit
0.1% of total
BAFU:2025
|
|
|
transport, freight, lorry, 16-32 metric ton, diesel, EURO 6
RoW
|
transport, freight, lorry, 16-32 metric ton, diesel, EURO 6
|
2.8
|
ton kilometer |
0.00415511
mol H+-Eq / unit
0.1% of total
0.782032
kg CO2-Eq / unit
0.5% of total
1.90967
CTUe / unit
0.1% of total
5.6925e-05
kg P-Eq / unit
0.0% of total
0.00182654
kg N-Eq / unit
0.7% of total
0.0198172
mol N-Eq / unit
0.7% of total
2.1097e-10
CTUh / unit
0.0% of total
4.8010e-09
CTUh / unit
0.0% of total
0.0897911
kBq U235-Eq / unit
0.2% of total
3.38698
dimensionless / unit
0.4% of total
4.1295e-08
kg CFC-11-Eq / unit
0.7% of total
2.0808e-08
disease incidence / unit
0.2% of total
0.00649511
kg NMVOC-Eq / unit
0.7% of total
11.2956
MJ, net calorific value / unit
0.5% of total
1.5091e-06
kg Sb-Eq / unit
0.0% of total
0.70621
m3 world Eq deprived / unit
0.2% of total
BAFU:2025
|
|
|
steel production, converter, low-alloyed
RER
|
steel, low-alloyed
|
8.4
|
kilogram |
0.05244
mol H+-Eq / unit
1.3% of total
17.9521
kg CO2-Eq / unit
12.4% of total
42.3523
CTUe / unit
2.9% of total
0.00700022
kg P-Eq / unit
0.7% of total
0.0121238
kg N-Eq / unit
4.6% of total
0.129373
mol N-Eq / unit
4.6% of total
6.2527e-08
CTUh / unit
4.9% of total
4.2849e-07
CTUh / unit
0.7% of total
3.21447
kBq U235-Eq / unit
6.8% of total
42.923
dimensionless / unit
5.1% of total
1.7327e-07
kg CFC-11-Eq / unit
3.1% of total
1.2229e-06
disease incidence / unit
9.8% of total
0.0552506
kg NMVOC-Eq / unit
6.2% of total
157.572
MJ, net calorific value / unit
6.4% of total
0.000158545
kg Sb-Eq / unit
1.2% of total
2.93589
m3 world Eq deprived / unit
0.7% of total
BAFU:2025
|
|
|
polyethylene, pellets, recycled to generic markets for LDPE and HDPE
RER
|
polyethylene, high density, granulate
|
5.6
|
kilogram |
0.0302184
mol H+-Eq / unit
0.8% of total
12.712
kg CO2-Eq / unit
8.8% of total
75.7357
CTUe / unit
5.2% of total
0.00070722
kg P-Eq / unit
0.1% of total
0.0067333
kg N-Eq / unit
2.6% of total
0.0737592
mol N-Eq / unit
2.6% of total
1.8203e-09
CTUh / unit
0.1% of total
4.8144e-08
CTUh / unit
0.1% of total
0.457124
kBq U235-Eq / unit
1.0% of total
5.2622
dimensionless / unit
0.6% of total
3.5662e-07
kg CFC-11-Eq / unit
6.5% of total
3.8019e-07
disease incidence / unit
3.0% of total
0.0322355
kg NMVOC-Eq / unit
3.6% of total
393.233
MJ, net calorific value / unit
16.0% of total
1.9210e-05
kg Sb-Eq / unit
0.2% of total
73.8064
m3 world Eq deprived / unit
17.2% of total
BAFU:2025
|
|
|
market for aluminium, wrought alloy
GLO
|
aluminium, wrought alloy
|
7
|
kilogram |
0.169
mol H+-Eq / unit
4.3% of total
34.819
kg CO2-Eq / unit
24.0% of total
102.722
CTUe / unit
7.0% of total
0.00919118
kg P-Eq / unit
0.9% of total
0.0308783
kg N-Eq / unit
11.8% of total
0.250858
mol N-Eq / unit
9.0% of total
3.9393e-08
CTUh / unit
3.1% of total
6.4852e-07
CTUh / unit
1.1% of total
18.9799
kBq U235-Eq / unit
40.0% of total
65.3126
dimensionless / unit
7.8% of total
6.0357e-07
kg CFC-11-Eq / unit
10.9% of total
1.8995e-06
disease incidence / unit
15.2% of total
0.0923168
kg NMVOC-Eq / unit
10.3% of total
535.777
MJ, net calorific value / unit
21.8% of total
2.9885e-05
kg Sb-Eq / unit
0.2% of total
239.206
m3 world Eq deprived / unit
55.7% of total
BAFU:2025
|
|
|
cobalt production
GLO
|
copper, cathode
|
2.8
|
kilogram |
1.71492
mol H+-Eq / unit
43.3% of total
7.52689
kg CO2-Eq / unit
5.2% of total
477.654
CTUe / unit
32.7% of total
0.491625
kg P-Eq / unit
47.9% of total
0.0788806
kg N-Eq / unit
30.2% of total
0.897778
mol N-Eq / unit
32.2% of total
2.7514e-07
CTUh / unit
21.4% of total
2.6228e-05
CTUh / unit
45.8% of total
2.40768
kBq U235-Eq / unit
5.1% of total
194.48
dimensionless / unit
23.1% of total
1.9037e-07
kg CFC-11-Eq / unit
3.4% of total
2.9283e-06
disease incidence / unit
23.4% of total
0.264677
kg NMVOC-Eq / unit
29.5% of total
103.69
MJ, net calorific value / unit
4.2% of total
0.00567205
kg Sb-Eq / unit
44.4% of total
8.14149
m3 world Eq deprived / unit
1.9% of total
BAFU:2025
|
|
|
treatment of electronics scrap from control units
RER
|
electronics scrap from control units
|
-4.2
|
kilogram |
-0.753229
mol H+-Eq / unit
-19.0% of total
-77.8491
kg CO2-Eq / unit
-53.7% of total
-626.282
CTUe / unit
-42.9% of total
-0.340986
kg P-Eq / unit
-33.2% of total
-0.0975759
kg N-Eq / unit
-37.3% of total
-1.00367
mol N-Eq / unit
-36.1% of total
-1.5703e-07
CTUh / unit
-12.2% of total
-7.8726e-06
CTUh / unit
-13.8% of total
-16.3402
kBq U235-Eq / unit
-34.5% of total
-553.472
dimensionless / unit
-65.8% of total
-6.5305e-06
kg CFC-11-Eq / unit
-118.1% of total
-3.3289e-06
disease incidence / unit
-26.6% of total
-0.329981
kg NMVOC-Eq / unit
-36.8% of total
-1064.35
MJ, net calorific value / unit
-43.2% of total
-0.0448238
kg Sb-Eq / unit
-351.2% of total
-592.041
m3 world Eq deprived / unit
-137.8% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
2 CLIC nodes and 15 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Choose software and background database settings once you open the Basket page.
| File | Downloads | Action |
|---|---|---|
| ecoinvent_3_12_cutoff.xlsx Primary | 0 | Log in to download |
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.0 | 2026-11-16 | Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens already include the source 0.769 internal treatment allocation: do not repeat it. Background is 3.12 cut-off, not the source APOS system. Deterministic inventory; no probability distributions added. | Current view |
Initial CLIC laboratory waste-RAM recovery adaptation. No industrial scale-up claim. Main chain and mass/economic wrappers are alternative accounting views, not additive demands. A20 burdens already include the source 0.769 internal treatment allocation: do not repeat it. Background is 3.12 cut-off, not the source APOS system. Deterministic inventory; no probability distributions added.
Publication route
A curator validated the batch manifest and an editor authorized publication. This route does not imply that CLIC's current structured community-review checklist was completed.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content