Simons A, Bauer C. Life cycle assessment of the Evolutionary Power Reactor (EPR) and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy. 2012;226(3):427-444. doi:10.1177/0957650912440549
Dataset details
Classification, keywords, bookmarks and download counts.
Classification
Nuclear electricity (energy/electricity/nuclear)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0
Classification path:
Energy >
Electricity >
Nuclear electricity
Keywords
electricity
nuclear electricity
Bookmarking is available only on the latest published dataset record.
Metadata & sourcesMethods, scope, reference years, publications, contributors, projects and funding.
Source
Source documentation, background profiles and references.
Scientific journal publication
Simons, A., & Bauer, C. Life cycle assessment of the Evolutionary Power Reactor (EPR) and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy. 2012;226(3):427-444. https://doi.org/10.1177/0957650912440549
Inventory changes relative to source:Not assessed
Equivalence to the original source inventory has not been established.
Background database
ecoinvent / 3.8
Background system model
cut-off
Biosphere database
ecoinvent / 3.8
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Reference years, modelling and allocation methods, contributors, publications, projects and funding.
Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
Source publication year
2012
Inventory reference year
Not specified
Foreground modelling approach
Not specified
Allocated product inventory
Not specified
Allocation or multifunctionality treatment
Not specified
Inventory contributions
Not specified
Methodology notes
The source is a 2012 prospective assessment of Swiss/French EPRs in 2030, using mixed-vintage fuel-cycle and infrastructure data. Table 4 distinguishes CH 1500 MWe from FR 1530 MWe; the common 1500-MWe description is not valid for the French scenario. The regional RER copy is not a separately tabulated source scenario. The paper's normal-operation boundaries exclude nuclear accidents. Equipment membership is traced only through unambiguous declared foreground links; underlying bills of materials and supplier/biosphere adaptations remain incompletely verified.
Intended application
Foreground modelling of the declared EPR hardware, fuel-cycle or electricity-production configuration.
Data origins
Literature
Other fields not yet completed (9)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type, System boundary, Included life cycle stages, Technology description, Use limitations
Publications (1)
Citation
Simons, A., Bauer, C. (2012). Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy 226(3), 427–444. https://doi.org/10.1177/0957650912440549
Title
Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Doi
10.1177/0957650912440549
Url
https://doi.org/10.1177/0957650912440549
Source type
Scientific journal
Publication year
2012
Relation
Primary source
Authors
Andrew Simons; Christian Bauer · 0000-0002-1083-9200
Projects (1)
Name
Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Url
https://doi.org/10.1177/0957650912440549
Relation
Source study
Funding (1)
Organization
Axpo Holding AG
Project
Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Evidence and qualifications (7)
Target field
data_origins
Origin
Editor verification
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Exact documented origins; no claim that every flow is measured.
Target field
intended_application
Origin
Editor verification
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Source-linked modelling context; no 2030 component year or measured manufacturer inventory is inferred.
DOI registration: title, publication dates and byline
Qualification
Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers.
Target field
publications
Origin
Editor verification
Source reference
https://api.ror.org/v2/organizations/03eh3y714
Source location
Organization identity and registered names
Qualification
Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope.
Target field
publications
Origin
Editor verification
Source reference
https://doi.org/10.1177/0957650912440549
Source location
Original paper/SI byline; pinned DOI registration and institutional identity evidence
Qualification
Canonical primary and legacy citations are aligned without changing freeform source, inventory source text or inventory contributors. Publication year is not a measurement/reference year. EPR underlying inventories are acknowledged to Roberto Dones and Roth et al. (2009); component quantities are not all printed in the 2012 article. Preserve each declared source role and historical affiliation.
Target field
methodology_notes
Origin
Editor verification
Source reference
https://doi.org/10.1177/0957650912440549
Source location
Table 4, source scope and acknowledgements; foreground equipment paths
Qualification
Distinguish electricity, dedicated plant equipment and fuel-cycle supply roles. Only CH/FR electricity nodes receive the explicit 2030 model year. No component measurement year, capacity factor, numeric TRL or accident-risk result is inferred.
Target field
funding
Origin
Editor verification
Source reference
https://doi.org/10.1177/0957650912440549
Source location
Source funding statement immediately before acknowledgements
Qualification
Axpo Holding AG funded the cited study. The project declaration is labelled by the paper title with relation source_study; no formal grant/acronym is invented and no funding of the CLIC adaptation is inferred.
Technology characterizationScale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Early commercial
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scaleHigher is more mature.9: routine commercial deployment8: commercial, but still niche or scaling7: first-commercial or advanced demonstration6: engineering-scale demonstration5: pilot or large prototype4: bench or lab validated3: research-stage conceptTechnology readiness level
123456789
earlymature
1 to 5 scaleLower is better.1: strong market- or operating-data basis2: commercially plausible, but still somewhat specific3: partly representative, with modelling or adaptation bias4: pilot, proxy-based, scaled-up, or prospective5: weak representation of the real technology stateTechnological representativeness
12345
strongweak
1 to 5 scaleLower is better.1: geography matches the claimed scope well2: regionally credible, but broader or less exact3: generic regional or global proxy4: weak proxy or clear geographic mismatch5: geography is effectively unsupportedGeographical representativeness
12345
strongweak
1 to 5 scaleLower is better.1: current for that technology class2: slightly dated, but still good3: dated enough to need caution4: stale, pilot-era, or prospective relative to current practice5: clearly not representative of the current stateTemporal representativeness
12345
strongweak
Missing exchange uncertainty generation:
Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Acidification54476.7
mol H+-Eq / unit
Climate change9.5805e+06
kg CO2-Eq / unit
Freshwater ecotoxicity3.7134e+07
CTUe / unit
Freshwater eutrophication3590.81
kg P-Eq / unit
Marine eutrophication9431.16
kg N-Eq / unit
Terrestrial eutrophication100215
mol N-Eq / unit
Human toxicity, cancer0.190968
CTUh / unit
Human toxicity, non-cancer1.00672
CTUh / unit
Ionising radiation2.5848e+06
kBq U235-Eq / unit
Land use4.6942e+07
dimensionless / unit
Ozone depletion0.154645
kg CFC-11-Eq / unit
Particulate matter0.749417
disease incidence / unit
Photochemical ozone formation32972.1
kg NMVOC-Eq / unit
Resource use, fossils1.3007e+08
MJ, net calorific value / unit
Resource use, minerals and metals316.441
kg Sb-Eq / unit
Water use2.8507e+06
m3 world Eq deprived / unit
Screening result
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Show all 16 indicator totals
Acidification54476.7
mol H+-Eq / unit
Climate change9.5805e+06
kg CO2-Eq / unit
Freshwater ecotoxicity3.7134e+07
CTUe / unit
Freshwater eutrophication3590.81
kg P-Eq / unit
Marine eutrophication9431.16
kg N-Eq / unit
Terrestrial eutrophication100215
mol N-Eq / unit
Human toxicity, cancer0.190968
CTUh / unit
Human toxicity, non-cancer1.00672
CTUh / unit
Ionising radiation2.5848e+06
kBq U235-Eq / unit
Land use4.6942e+07
dimensionless / unit
Ozone depletion0.154645
kg CFC-11-Eq / unit
Particulate matter0.749417
disease incidence / unit
Photochemical ozone formation32972.1
kg NMVOC-Eq / unit
Resource use, fossils1.3007e+08
MJ, net calorific value / unit
Resource use, minerals and metals316.441
kg Sb-Eq / unit
Water use2.8507e+06
m3 world Eq deprived / unit
Calculation details
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-23 19:09 UTC. These screening results do not replace a reviewed comparative LCA.
Dataset contents
Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.
Outputs
Reference flow1 rowReference production exchanges extracted from the uploaded inventory.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
Condenser EPR
RER
Condenser EPR
Axpo NH 5b / year technologies
1
unit
Metadata (1)
Allocation
100
Reference flow
Inputs
Technosphere inputs5 rowsLinked foreground or background product inputs used by this dataset.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
market for drawing of pipe, steel
GLO
drawing of pipe, steel
Materials/fuels
1.60e+05
kilogram
Metadata (4)
Loc
160000
Product
drawing of pipe, steel
Simapro name
Drawing of pipes, steel U
Uncertainty type
0
111.848mol H+-Eq / unit
0.2% of total
68934.1kg CO2-Eq / unit
0.7% of total
402417CTUe / unit
1.1% of total
19.3409kg P-Eq / unit
0.5% of total
25.0986kg N-Eq / unit
0.3% of total
245.027mol N-Eq / unit
0.2% of total
6.1769e-05CTUh / unit
0.0% of total
0.00107205CTUh / unit
0.1% of total
13531.1kBq U235-Eq / unit
0.5% of total
182929dimensionless / unit
0.4% of total
0.00344255kg CFC-11-Eq / unit
2.2% of total
0.00182358disease incidence / unit
0.2% of total
108.898kg NMVOC-Eq / unit
0.3% of total
475497MJ, net calorific value / unit
0.4% of total
0.496403kg Sb-Eq / unit
0.2% of total
9793.02m3 world Eq deprived / unit
0.3% of total
BAFU:2025
market for hot rolling, steel
GLO
hot rolling, steel
Materials/fuels
2.44e+06
kilogram
Metadata (4)
Loc
2440000
Product
hot rolling, steel
Simapro name
Hot rolling, steel U
Uncertainty type
0
552.831mol H+-Eq / unit
1.0% of total
405349kg CO2-Eq / unit
4.2% of total
1.8234e+06CTUe / unit
4.9% of total
68.1115kg P-Eq / unit
1.9% of total
204.781kg N-Eq / unit
2.2% of total
1977.66mol N-Eq / unit
2.0% of total
0.000492858CTUh / unit
0.3% of total
0.00736817CTUh / unit
0.7% of total
296502kBq U235-Eq / unit
11.5% of total
1.2243e+06dimensionless / unit
2.6% of total
0.0154625kg CFC-11-Eq / unit
10.0% of total
0.0190445disease incidence / unit
2.5% of total
1678.45kg NMVOC-Eq / unit
5.1% of total
8.8477e+06MJ, net calorific value / unit
6.8% of total
0.384391kg Sb-Eq / unit
0.1% of total
345537m3 world Eq deprived / unit
12.1% of total
BAFU:2025
market for steel, chromium steel 18/8
GLO
steel, chromium steel 18/8
Materials/fuels
2.60e+06
kilogram
Metadata (4)
Loc
2600000
Product
steel, chromium steel 18/8
Simapro name
Chromium steel 18/8, at plant U
Uncertainty type
0
53543.9mol H+-Eq / unit
98.3% of total
9.0426e+06kg CO2-Eq / unit
94.4% of total
3.4729e+07CTUe / unit
93.5% of total
3492.44kg P-Eq / unit
97.3% of total
9094.3kg N-Eq / unit
96.4% of total
96885.7mol N-Eq / unit
96.7% of total
0.190383CTUh / unit
99.7% of total
0.997739CTUh / unit
99.1% of total
2.2592e+06kBq U235-Eq / unit
87.4% of total
4.5039e+07dimensionless / unit
95.9% of total
0.133496kg CFC-11-Eq / unit
86.3% of total
0.726448disease incidence / unit
96.9% of total
30795.1kg NMVOC-Eq / unit
93.4% of total
1.1977e+08MJ, net calorific value / unit
92.1% of total
315.412kg Sb-Eq / unit
99.7% of total
2.4273e+06m3 world Eq deprived / unit
85.1% of total
BAFU:2025
market for transport, freight train
Europe without Switzerland
transport, freight train
Materials/fuels
5.72e+05
ton kilometer
Metadata (4)
Loc
572000
Product
transport, freight train
Simapro name
Transport, freight, rail U
Uncertainty type
0
41.8959mol H+-Eq / unit
0.1% of total
9569.6kg CO2-Eq / unit
0.1% of total
25203.5CTUe / unit
0.1% of total
5.77813kg P-Eq / unit
0.2% of total
13.9291kg N-Eq / unit
0.1% of total
139.573mol N-Eq / unit
0.1% of total
1.1523e-05CTUh / unit
0.0% of total
0.000121728CTUh / unit
0.0% of total
9380.58kBq U235-Eq / unit
0.4% of total
176927dimensionless / unit
0.4% of total
0.00023266kg CFC-11-Eq / unit
0.2% of total
0.000431161disease incidence / unit
0.1% of total
44.5126kg NMVOC-Eq / unit
0.1% of total
184985MJ, net calorific value / unit
0.1% of total
0.0214442kg Sb-Eq / unit
0.0% of total
5421.5m3 world Eq deprived / unit
0.2% of total
BAFU:2025
market for transport, freight, lorry, unspecified
RER
transport, freight, lorry, unspecified
Materials/fuels
2.86e+05
ton kilometer
Metadata (4)
Loc
286000
Product
transport, freight, lorry, unspecified
Simapro name
Transport, van <3.5t U
Uncertainty type
0
226.246mol H+-Eq / unit
0.4% of total
54035.5kg CO2-Eq / unit
0.6% of total
153740CTUe / unit
0.4% of total
5.14317kg P-Eq / unit
0.1% of total
93.0463kg N-Eq / unit
1.0% of total
966.902mol N-Eq / unit
1.0% of total
1.8978e-05CTUh / unit
0.0% of total
0.000419549CTUh / unit
0.0% of total
6241.25kBq U235-Eq / unit
0.2% of total
319334dimensionless / unit
0.7% of total
0.00201143kg CFC-11-Eq / unit
1.3% of total
0.0016698disease incidence / unit
0.2% of total
345.15kg NMVOC-Eq / unit
1.0% of total
783265MJ, net calorific value / unit
0.6% of total
0.126629kg Sb-Eq / unit
0.0% of total
62657.5m3 world Eq deprived / unit
2.2% of total
BAFU:2025
Parameters0 source definitions · values, formulas and uncertainty.
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Reuse and provenance
Downloads & files
This historical version remains available for citation and download, but a newer public version is now current.
Add to download basket
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Activity and product names for condenser EPR now use consistent catalogue spelling across the inventory and its supplier references. The physical recipe is unchanged.
Published · Latest
Show full version history table (2 versions)
Version
Published
Reason for this version
Link
Version 1.0.1
2026-11-03
Activity and product names for condenser EPR now use consistent catalogue spelling across the inventory and its supplier references. The physical recipe is unchanged.
First published inventory; no earlier version is available for comparison.
Review & discussionPublication provenance, scientific review and community discussion.
Public review record
Curator-led bulk import. Public evidence is shown without participant
accounts, assignments, recommendations, or private editor notes.
Show reviewHide review
Publication route
Curator-led bulk import
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.