Hydrogen via electrolysis

electrolyzer production, 1MWe, AEC, stack

Reference product electrolyzer, 1MWe, AEC, Stack RER

Published Version 1.0.1 Not assessed Latest published

Stable dataset identity electrolyzer-production-1mwe-aec-stack

Unit
unit
Reuse license
CC BY 4.0
Published
2026-11-03
Version
1.0.1
Technology maturity
See quality profile

Published inventory

Overview

Process description and catalog context. View scientific metadata

Description

Manufacturing reference for one stack of a nominal 1 MWe AEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Hydrogen via electrolysis (energy/hydrogen/electrolysis)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0

Classification path: Energy > Hydrogen > Hydrogen via electrolysis

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Scientific journal publication

Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759

Inventory changes relative to source: Not assessed

Equivalence to the original source inventory has not been established.

Background database
ecoinvent / 3.9
Background system model
cut-off
Biosphere database
ecoinvent / 3.9

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Mature commercial
Design capacity
1
Design capacity unit
MW
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
7 years
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 7 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change 104915 kg CO2-Eq / unit
Screening result

This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.

Show all 16 indicator totals
Acidification 5619.05 mol H+-Eq / unit
Climate change 104915 kg CO2-Eq / unit
Freshwater ecotoxicity 738709 CTUe / unit
Freshwater eutrophication 141.548 kg P-Eq / unit
Marine eutrophication 115.555 kg N-Eq / unit
Terrestrial eutrophication 1401.04 mol N-Eq / unit
Human toxicity, cancer 0.000229337 CTUh / unit
Human toxicity, non-cancer 0.00264904 CTUh / unit
Ionising radiation 32643.2 kBq U235-Eq / unit
Land use 508516 dimensionless / unit
Ozone depletion 0.00155372 kg CFC-11-Eq / unit
Particulate matter 0.0083316 disease incidence / unit
Photochemical ozone formation 683.679 kg NMVOC-Eq / unit
Resource use, fossils 1.4544e+06 MJ, net calorific value / unit
Resource use, minerals and metals 0.918635 kg Sb-Eq / unit
Water use 1.7308e+06 m3 world Eq deprived / unit
Calculation details

Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact 4e70d56a85b1 · calculated 2026-11-03 09:13 UTC. These screening results do not replace a reviewed comparative LCA.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
electrolyzer production, 1MWe, AEC, stack
RER
electrolyzer, 1MWe, AEC, Stack
1
unit - Reference flow

Inputs

Technosphere inputs 6 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
PTFE gasket, unfilled, engineering reference
144.2
kilogram
479.649 kg CO2-Eq / unit 0.5% of total
market for sheet rolling, chromium steel
GLO
sheet rolling, chromium steel
2.02e+04
kilogram
8675.28 kg CO2-Eq / unit 8.3% of total
BAFU:2025
market for steel, chromium steel 18/8, hot rolled
GLO
steel, chromium steel 18/8, hot rolled
2.02e+04
kilogram
8675.28 kg CO2-Eq / unit 8.3% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
2884.9
kilogram
28343 kg CO2-Eq / unit 27.0% of total
BAFU:2025
market group for electricity, low voltage
GLO
electricity, low voltage
9.56e+04
kilowatt hour
58217.3 kg CO2-Eq / unit 55.5% of total
BAFU:2025
diaphragm, alkaline electrolysis, zirconia-polysulfone with PPS mesh
121.8
kilogram -
524.665 kg CO2-Eq / unit 0.5% of total
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 2 versions · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  • Version 1.0.1 revises version 1.0.0.
  1. Version 1.0.0
    Published

    First published inventory; no earlier version is available for comparison.

    Superseded
  2. Version 1.0.1
    Published

    The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.

    Published · Viewing · Latest
Show full version history table (2 versions)
Version Published Reason for this version Link
Version 1.0.1 2026-11-03 The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams. Current view
Version 1.0.0 Superseded Published 2026-07-15 First published inventory; no earlier version is available for comparison. Open version
About this version

Why this version changed

The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.

Release notes

Dry loading, mesh geometry, solvent capture and recovery energy, separation and durability remain uncertain.

Source: https://doi.org/10.1016/j.est.2021.102759, https://doi.org/10.1016/j.est.2021.102759.

Declared foreground licence: CC-BY-4.0. Source publications and external supplier inventories retain their own terms.

Changes from version 1.0.0 Compare this version with its predecessor. Exchanges are grouped by type and change; biosphere labels include their environmental compartments. Open the base version. Show changes Hide changes

Why this version changed

The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.

Public revision record

This comparison is permanently visible with the published version so users can assess every detected change before reuse.

Modified exchanges
1
Added exchanges
2
Removed exchanges
3
Inventory metadata
0
Version metadata
15
Technosphere exchanges added 2
Technosphere exchanges added
Exchange / scope Field Previous value Revised value Reason
polytetrafluoroethylene gasket production, forming, resin supply proxy (technosphere / GLO / kilogram) Amount Not present 144.2 kilogram The PTFE gasket, unfilled, engineering reference entry supplies the material, process or treatment required by the revised reference. Diaphragm polymer, filler, reinforcement and process fluids belong to the chosen composite structure rather than an interchangeable membrane-material label. The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
diaphragm production, alkaline electrolysis, zirconia-polysulfone with polyphenylene sulfide mesh (technosphere / GLO / kilogram) Amount Not present 121.8 kilogram The diaphragm, alkaline electrolysis, zirconia-polysulfone with PPS mesh entry supplies the material, process or treatment required by the revised reference. Diaphragm polymer, filler, reinforcement and process fluids belong to the chosen composite structure rather than an interchangeable membrane-material label. The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
Technosphere exchanges removed 3
Technosphere exchanges removed
Exchange / scope Field Previous value Revised value Reason
market for tetrafluoroethylene (technosphere / GLO / kilogram) Amount 144.2 kilogram Not present The former tetrafluoroethylene entry is superseded by the revised product/component boundary. Diaphragm polymer, filler, reinforcement and process fluids belong to the chosen composite structure rather than an interchangeable membrane-material label. The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
market for polysulfone (technosphere / GLO / kilogram) Amount 48.8 kilogram Not present The former polysulfone entry is superseded by the revised product/component boundary. Diaphragm polymer, filler, reinforcement and process fluids belong to the chosen composite structure rather than an interchangeable membrane-material label. The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
market for zirconium oxide (technosphere / GLO / kilogram) Amount 73 kilogram Not present The former zirconium oxide entry is superseded by the revised product/component boundary. Diaphragm polymer, filler, reinforcement and process fluids belong to the chosen composite structure rather than an interchangeable membrane-material label. The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
Reference flows modified 1
Reference flows modified
Exchange / scope Field Previous value Revised value Reason
electrolyzer production, 1MWe, AEC, stack (production / RER / unit) Name electrolyzer production, 1MWe, AEC, Stack electrolyzer production, 1MWe, AEC, stack Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable.
Metadata changes 15
Metadata changes
Exchange / scope Field Previous value Revised value Reason
Version metadata Commercial maturity stage early_commercial mature_commercial No explanation was recorded for this change.
Version metadata Inventory evidence types Literature; Engineering estimate Literature; Proxy
Version metadata Geographical representativeness 2 3
Version metadata Methodology and allocation explanation The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Source model
Gerloff (2021) compares 1 MWe AEC, PEM and SOEC systems under German 2019, 2030, 2050 and renewable-electricity scenarios. The study uses ecoinvent 3.5 cutoff, European/German suppliers, Umberto+, ILCD 2.0 midpoint 2018 and IPCC 2013 GWP. CLIC uses separately declared 3.9 background/biosphere profiles and later material, lifetime and utility adaptations. Publication and scenario years do not date measured inputs.

Manufacturing basis
The reference is one manufactured stack, including 95553.31568 kWh assembly electricity. Processing services are separate from installed material mass. Stack assembly electricity is the source's three-stack total divided by three.

Lifetime accounting
The paper assumes 20 years at 8000 h/year and numerically counts three stacks, despite wording about three replacements. SM1 manufacturing-energy totals also include three stacks; the CLIC stack-manufacturing reference uses one third. Operating models separately purchase four PEM/AEC stacks or eight SOEC stacks with corresponding signed retirement. The retrieved IndWEDe document is the Kurzfassung, whereas the cited p. 178 belongs to an unrecovered full report. Selected lifetimes are not independently verified from that page.

Materials
Stack purchases include 144.2 kg PTFE gasket, 121.8 kg reinforced diaphragm, 20194.4 kg steel with forming service and 2884.9 kg nickel. The diaphragm represents an adapted dry composition and NMP/water scenario, rather than Gerloff's explicit 40% PSU/60% zirconia assumption.
Version metadata Plant lifetime Not set 7
Version metadata Contributors, publications, projects and supporting evidence Evidence: 1. Origin: source_import
Evidence: 1. Target field: data_origins
Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: source_import
Evidence: 2. Target field: data_origins
Evidence: 2. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 2. Source location: source
Evidence: 2. Source reference: Existing published CLIC inventory documentation
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: description
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: included_life_cycle_stages
Evidence: 4. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Evidence: 4. Source location: name
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: publications
Evidence: 5. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 5. Source location: source
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 6. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 6. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: publications
Evidence: 7. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
Evidence: 7. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers
Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: methodology_notes
Evidence: 8. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Evidence: 8. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Evidence: 8. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Publications: 1. Doi: 10.1016/j.est.2021.102759
Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Publications: 1. Scientific authors: 1. Name: Niklas Gerloff
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany
Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2021
Publications: 2. Doi: Not set
Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Publications: 2. Scientific authors: 1. Name: Tom Smolinka
Publications: 2. Scientific authors: 1. Orcid: Not set
Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 3. Name: Philip Sterchele
Publications: 2. Scientific authors: 3. Orcid: Not set
Publications: 2. Scientific authors: 4. Name: Andreas Palzer
Publications: 2. Scientific authors: 4. Orcid: Not set
Publications: 2. Scientific authors: 5. Name: Franz Lehner
Publications: 2. Scientific authors: 5. Orcid: Not set
Publications: 2. Scientific authors: 6. Name: Malte Jansen
Publications: 2. Scientific authors: 6. Orcid: Not set
Publications: 2. Scientific authors: 7. Name: Steffen Kiemel
Publications: 2. Scientific authors: 7. Orcid: Not set
Publications: 2. Scientific authors: 8. Name: Robert Miehe
Publications: 2. Scientific authors: 8. Orcid: Not set
Publications: 2. Scientific authors: 9. Name: Sylvia Wahren
Publications: 2. Scientific authors: 9. Orcid: Not set
Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann
Publications: 2. Scientific authors: 10. Orcid: Not set
Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Evidence: 1. Origin: source_import
Evidence: 1. Target field: data_origins
Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: source_import
Evidence: 2. Target field: data_origins
Evidence: 2. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 2. Source location: description
Evidence: 2. Source reference: Existing published CLIC inventory documentation
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: included_life_cycle_stages
Evidence: 4. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Evidence: 4. Source location: name
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: publications
Evidence: 5. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 5. Source location: source
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 6. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 6. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: publications
Evidence: 7. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
Evidence: 7. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers
Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: methodology_notes
Evidence: 8. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Evidence: 8. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Evidence: 8. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 9. Origin: editor_verification
Evidence: 9. Target field: technology_description
Evidence: 9. Qualification: Technical-characterisation review TC-2062. Design capacity: 1.000000. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 9. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 9. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 10. Origin: editor_verification
Evidence: 10. Target field: technology_description
Evidence: 10. Qualification: Technical-characterisation review TC-2062. Design capacity unit: MW. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 10. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 10. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 11. Origin: editor_verification
Evidence: 11. Target field: technology_description
Evidence: 11. Qualification: Technical-characterisation review TC-2062. Capacity factor (%): Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 11. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 11. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 12. Origin: editor_verification
Evidence: 12. Target field: technology_description
Evidence: 12. Qualification: Technical-characterisation review TC-2062. Annual production volume: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 12. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 12. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 13. Origin: editor_verification
Evidence: 13. Target field: technology_description
Evidence: 13. Qualification: Technical-characterisation review TC-2062. Annual production volume unit: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 13. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 13. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 14. Origin: editor_verification
Evidence: 14. Target field: technology_description
Evidence: 14. Qualification: Technical-characterisation review TC-2062. Annual production volume year: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 14. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 14. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 15. Origin: editor_verification
Evidence: 15. Target field: technology_description
Evidence: 15. Qualification: Technical-characterisation review TC-2062. Plant or represented-asset lifetime (years): 7. Basis: Literal compiler-selected service-life assumption for the represented AEC stack7 year s or SOEC balance-of-plant 20 year s, not the manufacturing factory lifespan. Current H2service allocations corroborate four stack cohorts over 27.5 year s or one BOP over 20 year s. Rounded stack-year assumption is not regenerated from annual hours or asserted as observed survival. Evidence classification: literal compiler asset life and current allocation check. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 15. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 15. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 16. Origin: editor_verification
Evidence: 16. Target field: technology_description
Evidence: 16. Qualification: Technical-characterisation review TC-2062. Commercial maturity stage: mature_commercial. Basis: Curator assessment of established alkaline/PEM manufacturing and hydrogen-production routes, corroborated by primary energy-agency context. Numeric9is not assigned by Gerloffto each exact CLIC object and does not validate the model material, pressure, water or lifetime assumptions. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 16. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 16. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 17. Origin: editor_verification
Evidence: 17. Target field: technology_description
Evidence: 17. Qualification: Technical-characterisation review TC-2062. Technology readiness level: 9. Basis: Curator assessment of established alkaline/PEM manufacturing and hydrogen-production routes, corroborated by primary energy-agency context. Numeric9is not assigned by Gerloffto each exact CLIC object and does not validate the model material, pressure, water or lifetime assumptions. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 17. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 17. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 18. Origin: editor_verification
Evidence: 18. Target field: technology_description
Evidence: 18. Qualification: Technical-characterisation review TC-2062. Technological representativeness: 4. Basis: Curator assessment of a hybrid literature/compiler model with selected updated membrane/alloy/PCS/drive and utility assumptions. Established route maturity does not make exact bill and performance representative measured production. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 18. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 18. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 19. Origin: editor_verification
Evidence: 19. Target field: technology_description
Evidence: 19. Qualification: Technical-characterisation review TC-2062. Geographical representativeness: 3. Basis: Curator assessment of generic regional supplier/material references and scenario electricity choices, not a matched or production-weighted factory population. Selected supply scenarios do not independently establish equipment manufacturing geography. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 19. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 19. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 20. Origin: editor_verification
Evidence: 20. Target field: technology_description
Evidence: 20. Qualification: Technical-characterisation review TC-2062. Temporal representativeness: 4. Basis: Curator assessment of mixed historical source materials, IndWEDe/manufacturer scenario assumptions and later compiler adaptations.2019/2030/2050electricity scenarios,2021publication and current equipment availability are not full-inventory observation periods. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 20. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 20. Source reference: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Doi: 10.1016/j.est.2021.102759
Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Publications: 1. Scientific authors: 1. Name: Niklas Gerloff
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany
Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2021
Publications: 2. Doi: Not set
Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Publications: 2. Scientific authors: 1. Name: Tom Smolinka
Publications: 2. Scientific authors: 1. Orcid: Not set
Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 3. Name: Philip Sterchele
Publications: 2. Scientific authors: 3. Orcid: Not set
Publications: 2. Scientific authors: 4. Name: Andreas Palzer
Publications: 2. Scientific authors: 4. Orcid: Not set
Publications: 2. Scientific authors: 5. Name: Franz Lehner
Publications: 2. Scientific authors: 5. Orcid: Not set
Publications: 2. Scientific authors: 6. Name: Malte Jansen
Publications: 2. Scientific authors: 6. Orcid: Not set
Publications: 2. Scientific authors: 7. Name: Steffen Kiemel
Publications: 2. Scientific authors: 7. Orcid: Not set
Publications: 2. Scientific authors: 8. Name: Robert Miehe
Publications: 2. Scientific authors: 8. Orcid: Not set
Publications: 2. Scientific authors: 9. Name: Sylvia Wahren
Publications: 2. Scientific authors: 9. Orcid: Not set
Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann
Publications: 2. Scientific authors: 10. Orcid: Not set
Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Version metadata System boundary Foreground reference: 1 unit of electrolyzer, 1MWe, AEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Material/component supply, recorded forming services and assembly electricity for one AEC stack. Hydrogen-production utilities, lifetime multiplication and the paired finished-equipment treatment are modelled separately.
Version metadata Technological representativeness 2 4
Version metadata Technology description Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack. AEC stack represented by material supply, forming/processing and component purchases. This unit represents one manufactured component, separately from the operating model's lifetime purchases. PTFE gasket and reinforced zirconia/polysulfone/PPS diaphragm are supplied as separate engineering components.
Version metadata Technology readiness level 8 9
Version metadata Temporal representativeness 2 4
Version metadata Limitations on use Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Source component quantities and estimated assembly energy do not establish a measured complete manufacturer bill of materials, actual industrial yield or equivalent supplier grades/performance. SM1 BoP energy totals follow approximately linear 1 MW scaling, despite the paragraph's 0.7 exponent; they are about 7.94 times a reconstruction using that exponent. Some component intensities may already be scaled. Original H2_generation and data_generation_material workbooks were not recovered, limiting exact reconstruction. Diaphragm dry loading, mesh geometry, solvent/water partition, recovery energy, emissions, separation performance and durability remain unverified. The PTFE resin/forming grade and generic reject treatment are proxies. Neither component's engineering assumptions establish measured commercial performance.
Version metadata Description Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack.

The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.

Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Manufacturing reference for one stack of a nominal 1 MWe AEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations. Describe the actual reference flow, process boundary, engineering assumptions and source limitations in reader-facing language. Remove operational review/release instructions and distinguish capacity/component services from operating-energy inputs; the inventory content and declared terms are preserved.
Version metadata Intended application Not set Provision of one AEC electrolyzer stack in compatible operating or equipment scenarios with separate lifetime and retirement accounting. Apply reviewed discovery metadata and change explanations from the curated release.
Version metadata Name electrolyzer production, 1MWe, AEC, Stack electrolyzer production, 1MWe, AEC, stack Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable.
Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content