Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack.
The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.
Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Dataset details
Classification, keywords, bookmarks and download counts.
Classification
Hydrogen via electrolysis (energy/hydrogen/electrolysis)
Bookmarks
0
Raw file downloads
0
Generated export downloads
1
Classification path:
Energy >
Hydrogen >
Hydrogen via electrolysis
Keywords
hydrogen
hydrogen via electrolysis
electrolysis
Bookmarking is available only on the latest published dataset record.
Metadata & sourcesMethods, scope, reference years, publications, contributors, projects and funding.
Source
Source documentation, background profiles and references.
Scientific journal publication
Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Inventory changes relative to source:Not assessed
Equivalence to the original source inventory has not been established.
Background database
ecoinvent / 3.9
Background system model
cut-off
Biosphere database
ecoinvent / 3.9
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Reference years, modelling and allocation methods, contributors, publications, projects and funding.
Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
Source publication year
2021
Inventory reference year
Not specified
Foreground modelling approach
Not specified
Allocated product inventory
Not specified
Allocation or multifunctionality treatment
Not specified
Inventory contributions
Not specified
Projects
Not specified
Funding
Not specified
Methodology notes
The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.
System boundary
Foreground reference: 1 unit of electrolyzer, 1MWe, AEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.
Included life cycle stages
Manufacturing
Technology description
Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack.
Use limitations
Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Data origins
Literature, Engineering estimate
Other fields not yet completed (6)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type, Intended application
Publications (2)
Citation
Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Title
Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Doi
10.1016/j.est.2021.102759
Url
https://doi.org/10.1016/j.est.2021.102759
Source type
Scientific journal
Publication year
2021
Relation
Primary source
Authors
Niklas Gerloff
Citation
Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Title
Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Tom Smolinka; Nikolai Wiebe; Philip Sterchele; Andreas Palzer; Franz Lehner; Malte Jansen; Steffen Kiemel; Robert Miehe; Sylvia Wahren; Fabian Zimmermann
Evidence and qualifications (8)
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
description
Qualification
Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Target field
included_life_cycle_stages
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
name
Qualification
Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Target field
publications
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Publisher-deposited registry /message/title, /message/published and /message/author
Qualification
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Qualification
Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, AEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Technology characterizationScale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Early commercial
Design capacity
1
Design capacity unit
MW
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scaleHigher is more mature.9: routine commercial deployment8: commercial, but still niche or scaling7: first-commercial or advanced demonstration6: engineering-scale demonstration5: pilot or large prototype4: bench or lab validated3: research-stage conceptTechnology readiness level
123456789
earlymature
1 to 5 scaleLower is better.1: strong market- or operating-data basis2: commercially plausible, but still somewhat specific3: partly representative, with modelling or adaptation bias4: pilot, proxy-based, scaled-up, or prospective5: weak representation of the real technology stateTechnological representativeness
12345
strongweak
1 to 5 scaleLower is better.1: geography matches the claimed scope well2: regionally credible, but broader or less exact3: generic regional or global proxy4: weak proxy or clear geographic mismatch5: geography is effectively unsupportedGeographical representativeness
12345
strongweak
1 to 5 scaleLower is better.1: current for that technology class2: slightly dated, but still good3: dated enough to need caution4: stale, pilot-era, or prospective relative to current practice5: clearly not representative of the current stateTemporal representativeness
12345
strongweak
Missing exchange uncertainty generation:
Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Acidification5619.82
mol H+-Eq / unit
Climate change117316
kg CO2-Eq / unit
Freshwater ecotoxicity738104
CTUe / unit
Freshwater eutrophication141.781
kg P-Eq / unit
Marine eutrophication114.191
kg N-Eq / unit
Terrestrial eutrophication1406.1
mol N-Eq / unit
Human toxicity, cancer0.000247988
CTUh / unit
Human toxicity, non-cancer0.0026806
CTUh / unit
Ionising radiation32921.4
kBq U235-Eq / unit
Land use511188
dimensionless / unit
Ozone depletion0.371281
kg CFC-11-Eq / unit
Particulate matter0.00832842
disease incidence / unit
Photochemical ozone formation686.744
kg NMVOC-Eq / unit
Resource use, fossils1.4826e+06
MJ, net calorific value / unit
Resource use, minerals and metals0.682084
kg Sb-Eq / unit
Water use1.7287e+06
m3 world Eq deprived / unit
Screening result
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Show all 16 indicator totals
Acidification5619.82
mol H+-Eq / unit
Climate change117316
kg CO2-Eq / unit
Freshwater ecotoxicity738104
CTUe / unit
Freshwater eutrophication141.781
kg P-Eq / unit
Marine eutrophication114.191
kg N-Eq / unit
Terrestrial eutrophication1406.1
mol N-Eq / unit
Human toxicity, cancer0.000247988
CTUh / unit
Human toxicity, non-cancer0.0026806
CTUh / unit
Ionising radiation32921.4
kBq U235-Eq / unit
Land use511188
dimensionless / unit
Ozone depletion0.371281
kg CFC-11-Eq / unit
Particulate matter0.00832842
disease incidence / unit
Photochemical ozone formation686.744
kg NMVOC-Eq / unit
Resource use, fossils1.4826e+06
MJ, net calorific value / unit
Resource use, minerals and metals0.682084
kg Sb-Eq / unit
Water use1.7287e+06
m3 world Eq deprived / unit
Calculation details
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-09-30 13:58 UTC. These screening results do not replace a reviewed comparative LCA.
Dataset contents
Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.
Outputs
Reference flow1 rowReference production exchanges extracted from the uploaded inventory.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
electrolyzer production, 1MWe, AEC, Stack
RER
electrolyzer, 1MWe, AEC, Stack
1
unit
-
Reference flow
Inputs
Technosphere inputs7 rowsLinked foreground or background product inputs used by this dataset.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
market for tetrafluoroethylene
GLO
tetrafluoroethylene
144.2
kilogram
Metadata (1)
Comment
gasket
10.7639mol H+-Eq / unit
0.2% of total
13030.7kg CO2-Eq / unit
11.1% of total
17040.8CTUe / unit
2.3% of total
0.548612kg P-Eq / unit
0.4% of total
1.22063kg N-Eq / unit
1.1% of total
11.8663mol N-Eq / unit
0.8% of total
2.0431e-05CTUh / unit
8.2% of total
5.0430e-05CTUh / unit
1.9% of total
599.295kBq U235-Eq / unit
1.8% of total
6530.95dimensionless / unit
1.3% of total
0.369787kg CFC-11-Eq / unit
99.6% of total
9.4920e-05disease incidence / unit
1.1% of total
6.54865kg NMVOC-Eq / unit
1.0% of total
43955.1MJ, net calorific value / unit
3.0% of total
0.0141893kg Sb-Eq / unit
2.1% of total
808.121m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for sheet rolling, chromium steel
GLO
sheet rolling, chromium steel
2.02e+04
kilogram
Metadata (1)
Comment
anode and cathode with frame
43.7745mol H+-Eq / unit
0.8% of total
8675.28kg CO2-Eq / unit
7.4% of total
157963CTUe / unit
21.4% of total
4.31988kg P-Eq / unit
3.0% of total
8.06375kg N-Eq / unit
7.1% of total
85.6937mol N-Eq / unit
6.1% of total
7.8942e-05CTUh / unit
31.8% of total
0.000261536CTUh / unit
9.8% of total
4650.49kBq U235-Eq / unit
14.1% of total
47285.9dimensionless / unit
9.3% of total
0.00016916kg CFC-11-Eq / unit
0.0% of total
0.000487215disease incidence / unit
5.9% of total
31.3698kg NMVOC-Eq / unit
4.6% of total
138882MJ, net calorific value / unit
9.4% of total
0.13507kg Sb-Eq / unit
19.8% of total
2712.12m3 world Eq deprived / unit
0.2% of total
BAFU:2025
market for steel, chromium steel 18/8, hot rolled
GLO
steel, chromium steel 18/8, hot rolled
2.02e+04
kilogram
Metadata (1)
Comment
anode and cathode with frame
43.7745mol H+-Eq / unit
0.8% of total
8675.28kg CO2-Eq / unit
7.4% of total
157963CTUe / unit
21.4% of total
4.31988kg P-Eq / unit
3.0% of total
8.06375kg N-Eq / unit
7.1% of total
85.6937mol N-Eq / unit
6.1% of total
7.8942e-05CTUh / unit
31.8% of total
0.000261536CTUh / unit
9.8% of total
4650.49kBq U235-Eq / unit
14.1% of total
47285.9dimensionless / unit
9.3% of total
0.00016916kg CFC-11-Eq / unit
0.0% of total
0.000487215disease incidence / unit
5.9% of total
31.3698kg NMVOC-Eq / unit
4.6% of total
138882MJ, net calorific value / unit
9.4% of total
0.13507kg Sb-Eq / unit
19.8% of total
2712.12m3 world Eq deprived / unit
0.2% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
2884.9
kilogram
Metadata (1)
Comment
anode and cathode with frame
5376mol H+-Eq / unit
95.7% of total
28343kg CO2-Eq / unit
24.2% of total
223898CTUe / unit
30.3% of total
111.172kg P-Eq / unit
78.4% of total
68.8087kg N-Eq / unit
60.3% of total
950.472mol N-Eq / unit
67.6% of total
3.5392e-05CTUh / unit
14.3% of total
0.00131375CTUh / unit
49.0% of total
7119.7kBq U235-Eq / unit
21.6% of total
175375dimensionless / unit
34.3% of total
0.000549398kg CFC-11-Eq / unit
0.1% of total
0.00595365disease incidence / unit
71.5% of total
527.756kg NMVOC-Eq / unit
76.8% of total
339160MJ, net calorific value / unit
22.9% of total
0.29164kg Sb-Eq / unit
42.8% of total
14299.8m3 world Eq deprived / unit
0.8% of total
BAFU:2025
market for polysulfone
GLO
polysulfone
48.8
kilogram
Metadata (1)
Comment
diaphragm, zirfon
0.360135mol H+-Eq / unit
0.0% of total
156.263kg CO2-Eq / unit
0.1% of total
537.815CTUe / unit
0.1% of total
0.0338053kg P-Eq / unit
0.0% of total
0.0769812kg N-Eq / unit
0.1% of total
0.759935mol N-Eq / unit
0.1% of total
1.1096e-07CTUh / unit
0.0% of total
8.2262e-07CTUh / unit
0.0% of total
35.9334kBq U235-Eq / unit
0.1% of total
340.704dimensionless / unit
0.1% of total
4.1616e-06kg CFC-11-Eq / unit
0.0% of total
3.0484e-06disease incidence / unit
0.0% of total
0.432298kg NMVOC-Eq / unit
0.1% of total
3055.41MJ, net calorific value / unit
0.2% of total
0.000351782kg Sb-Eq / unit
0.1% of total
48.6229m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for zirconium oxide
GLO
zirconium oxide
73
kilogram
Metadata (1)
Comment
diaphragm, zirfon
0.912496mol H+-Eq / unit
0.0% of total
218.164kg CO2-Eq / unit
0.2% of total
884.212CTUe / unit
0.1% of total
0.113196kg P-Eq / unit
0.1% of total
0.186911kg N-Eq / unit
0.2% of total
1.78751mol N-Eq / unit
0.1% of total
2.1876e-07CTUh / unit
0.1% of total
9.7131e-06CTUh / unit
0.4% of total
119.281kBq U235-Eq / unit
0.4% of total
1982.58dimensionless / unit
0.4% of total
5.3911e-06kg CFC-11-Eq / unit
0.0% of total
7.9617e-06disease incidence / unit
0.1% of total
0.629679kg NMVOC-Eq / unit
0.1% of total
3523.4MJ, net calorific value / unit
0.2% of total
0.00291688kg Sb-Eq / unit
0.4% of total
87.5379m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market group for electricity, low voltage
GLO
electricity, low voltage
9.56e+04
kilowatt hour
Metadata (1)
Comment
assembly energy
144.235mol H+-Eq / unit
2.6% of total
58217.3kg CO2-Eq / unit
49.6% of total
179817CTUe / unit
24.4% of total
21.2733kg P-Eq / unit
15.0% of total
27.7703kg N-Eq / unit
24.3% of total
269.824mol N-Eq / unit
19.2% of total
3.3952e-05CTUh / unit
13.7% of total
0.000782812CTUh / unit
29.2% of total
15746.2kBq U235-Eq / unit
47.8% of total
232387dimensionless / unit
45.5% of total
0.000597009kg CFC-11-Eq / unit
0.2% of total
0.0012944disease incidence / unit
15.5% of total
88.6379kg NMVOC-Eq / unit
12.9% of total
815134MJ, net calorific value / unit
55.0% of total
0.102847kg Sb-Eq / unit
15.1% of total
1.7081e+06m3 world Eq deprived / unit
98.8% of total
BAFU:2025
Parameters0 source definitions · values, formulas and uncertainty.
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Supply-chain graph
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
Current datasetTechnosphere inputsEnvironmental resource inputsEmissions
1 CLIC node
and 7 background boundary nodes shown.
Direct inputs appear to the left of the current dataset, while emissions appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Downloads & files
This historical version remains available for citation and download, but a newer public version is now current.
Add to download basket
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
Published · Latest
Show full version history table (2 versions)
Version
Published
Reason for this version
Link
Version 1.0.1
2026-11-03
The alkaline stack now represents a reinforced dry diaphragm and its solvent/water processing, with material-specific manufacturing and retirement streams.
First published inventory; no earlier version is available for comparison.
Review & discussionPublication provenance, scientific review and community discussion.
Public review record
Curator-led bulk import. Public evidence is shown without participant
accounts, assignments, recommendations, or private editor notes.
Show reviewHide review
Publication route
Curator-led bulk import
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.