Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
- Source publication year
- 2012
- Inventory reference year
- Not specified
- Foreground modelling approach
- Not specified
- Allocated product inventory
- Not specified
- Allocation or multifunctionality treatment
- Not specified
- Inventory contributions
- Not specified
- Methodology notes
- The source is a 2012 prospective assessment of Swiss/French EPRs in 2030, using mixed-vintage fuel-cycle and infrastructure data. Table 4 distinguishes CH 1500 MWe from FR 1530 MWe; the common 1500-MWe description is not valid for the French scenario. The regional RER copy is not a separately tabulated source scenario. The paper's normal-operation boundaries exclude nuclear accidents. Equipment membership is traced only through unambiguous declared foreground links; underlying bills of materials and supplier/biosphere adaptations remain incompletely verified.
- Intended application
- Foreground modelling of the declared EPR hardware, fuel-cycle or electricity-production configuration.
- Data origins
- Literature
Other fields not yet completed (9)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type, System boundary, Included life cycle stages, Technology description, Use limitations
Publications (1)
- Citation
- Simons, A., Bauer, C. (2012). Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy 226(3), 427–444. https://doi.org/10.1177/0957650912440549
- Title
- Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
- Doi
- 10.1177/0957650912440549
- Url
- https://doi.org/10.1177/0957650912440549
- Source type
- Scientific journal
- Publication year
- 2012
- Relation
- Primary source
- Authors
- Andrew Simons; Christian Bauer · 0000-0002-1083-9200
Projects (1)
- Name
- Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
- Url
- https://doi.org/10.1177/0957650912440549
- Relation
- Source study
Funding (1)
- Organization
- Axpo Holding AG
- Project
- Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Evidence and qualifications (7)
- Target field
- data_origins
- Origin
- Editor verification
- Source reference
- Existing published CLIC inventory documentation
- Source location
- source
- Qualification
- Exact documented origins; no claim that every flow is measured.
- Target field
- intended_application
- Origin
- Editor verification
- Source reference
- Existing published CLIC inventory documentation
- Source location
- source
- Qualification
- Source-linked modelling context; no 2030 component year or measured manufacturer inventory is inferred.
- Target field
- publications
- Origin
- Editor verification
- Source reference
- https://api.crossref.org/works/10.1177%2F0957650912440549
- Source location
- DOI registration: title, publication dates and byline
- Qualification
- Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers.
- Target field
- publications
- Origin
- Editor verification
- Source reference
- https://api.ror.org/v2/organizations/03eh3y714
- Source location
- Organization identity and registered names
- Qualification
- Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope.
- Target field
- publications
- Origin
- Editor verification
- Source reference
- https://doi.org/10.1177/0957650912440549
- Source location
- Original paper/SI byline; pinned DOI registration and institutional identity evidence
- Qualification
- Canonical primary and legacy citations are aligned without changing freeform source, inventory source text or inventory contributors. Publication year is not a measurement/reference year. EPR underlying inventories are acknowledged to Roberto Dones and Roth et al. (2009); component quantities are not all printed in the 2012 article. Preserve each declared source role and historical affiliation.
- Target field
- methodology_notes
- Origin
- Editor verification
- Source reference
- https://doi.org/10.1177/0957650912440549
- Source location
- Table 4, source scope and acknowledgements; foreground equipment paths
- Qualification
- Distinguish electricity, dedicated plant equipment and fuel-cycle supply roles. Only CH/FR electricity nodes receive the explicit 2030 model year. No component measurement year, capacity factor, numeric TRL or accident-risk result is inferred.
- Target field
- funding
- Origin
- Editor verification
- Source reference
- https://doi.org/10.1177/0957650912440549
- Source location
- Source funding statement immediately before acknowledgements
- Qualification
- Axpo Holding AG funded the cited study. The project declaration is labelled by the paper title with relation source_study; no formal grant/acronym is invented and no funding of the CLIC adaptation is inferred.