Description
Supply of 1 kg of copper from oxide copper ore (hydrometallurgy) for battery electrode or cell material production. Solvent extraction and electrowinning au.
Lithium-ion batteries
Reference product copper from oxide copper ore (hydrometallurgy) AU
Stable dataset identity
solvent-extraction-and-electrowinning
1.0.0Published inventory
Process description and catalog context. View scientific metadata
Supply of 1 kg of copper from oxide copper ore (hydrometallurgy) for battery electrode or cell material production. Solvent extraction and electrowinning au.
Classification, keywords, bookmarks and download counts.
Classification path: Materials > Batteries > Lithium-ion batteries
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
https://doi.org/10.1016/j.jclepro.2024.144645; dataset https://doi.org/10.5281/zenodo.12724732; 0.Cu!A203; SHA-256 bfa2b1212a458252e788da69dfaf569853af8954ba5574f2e403fc93919a4475
Inventory changes relative to source: Modified inventory
The source ecoinvent 3.9.1 suppliers are replaced by ecoinvent 3.12 cut-off suppliers, including documented proxies. The published foreground quantities are retained.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per kilogram, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-16 10:56 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
solvent extraction and electrowinning
AU
|
copper from oxide copper ore (hydrometallurgy)
|
1
|
kilogram | Reference flow |
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
Heat, waste
|
air
|
30.9
|
megajoule |
0
mol H+-Eq / kilogram
0.0% of total
0
kg CO2-Eq / kilogram
0.0% of total
0
CTUe / kilogram
0.0% of total
0
kg P-Eq / kilogram
0.0% of total
0
kg N-Eq / kilogram
0.0% of total
0
mol N-Eq / kilogram
0.0% of total
0
CTUh / kilogram
0.0% of total
0
CTUh / kilogram
0.0% of total
0
kBq U235-Eq / kilogram
0.0% of total
0
dimensionless / kilogram
0.0% of total
0
kg CFC-11-Eq / kilogram
0.0% of total
0
disease incidence / kilogram
0.0% of total
0
kg NMVOC-Eq / kilogram
0.0% of total
0
MJ, net calorific value / kilogram
0.0% of total
0
kg Sb-Eq / kilogram
0.0% of total
0
m3 world Eq deprived / kilogram
0.0% of total
EF biosphere factor
|
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
electricity production, hydro, run-of-river
AU
|
electricity, high voltage
|
1.37
|
kilowatt hour |
2.2524e-05
mol H+-Eq / kilogram
0.0% of total
0.00984251
kg CO2-Eq / kilogram
0.2% of total
0.0133335
CTUe / kilogram
0.0% of total
3.5422e-06
kg P-Eq / kilogram
0.0% of total
5.2604e-06
kg N-Eq / kilogram
0.0% of total
5.6388e-05
mol N-Eq / kilogram
0.0% of total
1.0667e-11
CTUh / kilogram
0.1% of total
1.6246e-10
CTUh / kilogram
0.1% of total
0.00183899
kBq U235-Eq / kilogram
0.3% of total
0.109312
dimensionless / kilogram
0.0% of total
7.9782e-11
kg CFC-11-Eq / kilogram
0.1% of total
5.4120e-10
disease incidence / kilogram
0.0% of total
1.9513e-05
kg NMVOC-Eq / kilogram
0.0% of total
0.0584509
MJ, net calorific value / kilogram
0.1% of total
8.2167e-08
kg Sb-Eq / kilogram
0.0% of total
2.55106
m3 world Eq deprived / kilogram
15.4% of total
BAFU:2025
|
|
|
market for electricity, high voltage
AU
|
electricity, high voltage
|
0.91
|
kilowatt hour |
0.000862079
mol H+-Eq / kilogram
0.6% of total
0.603067
kg CO2-Eq / kilogram
10.4% of total
2.74546
CTUe / kilogram
3.6% of total
0.000627577
kg P-Eq / kilogram
-0.2% of total
0.000336562
kg N-Eq / kilogram
1.4% of total
0.00239197
mol N-Eq / kilogram
0.4% of total
3.4604e-10
CTUh / kilogram
2.0% of total
6.4251e-09
CTUh / kilogram
5.8% of total
0.0117574
kBq U235-Eq / kilogram
1.8% of total
1.42027
dimensionless / kilogram
-0.3% of total
4.3899e-09
kg CFC-11-Eq / kilogram
4.8% of total
4.8893e-09
disease incidence / kilogram
0.4% of total
0.000685332
kg NMVOC-Eq / kilogram
0.5% of total
7.49007
MJ, net calorific value / kilogram
9.9% of total
4.0424e-07
kg Sb-Eq / kilogram
0.0% of total
0.107458
m3 world Eq deprived / kilogram
0.6% of total
BAFU:2025
|
|
|
leached copper concentrate from oxide copper ore (hydrometallurgy)
|
1
|
kilogram |
0.152431
mol H+-Eq / kilogram
99.4% of total
5.18077
kg CO2-Eq / kilogram
89.4% of total
72.5056
CTUe / kilogram
96.3% of total
-0.409432
kg P-Eq / kilogram
100.2% of total
0.0231188
kg N-Eq / kilogram
98.5% of total
0.666367
mol N-Eq / kilogram
99.6% of total
1.6628e-08
CTUh / kilogram
97.9% of total
1.0405e-07
CTUh / kilogram
94.0% of total
0.627783
kBq U235-Eq / kilogram
97.9% of total
-508.467
dimensionless / kilogram
100.3% of total
8.7740e-08
kg CFC-11-Eq / kilogram
95.2% of total
1.1415e-06
disease incidence / kilogram
99.5% of total
0.127814
kg NMVOC-Eq / kilogram
99.5% of total
67.8817
MJ, net calorific value / kilogram
90.0% of total
0.000944682
kg Sb-Eq / kilogram
99.9% of total
13.9604
m3 world Eq deprived / kilogram
84.0% of total
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
3 CLIC nodes and 3 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Choose software and background database settings once you open the Basket page.
| File | Downloads | Action |
|---|---|---|
| ecoinvent_3_12_cutoff.xlsx Primary | 0 | Log in to download |
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
Initial CLIC BAT4EVER adaptation. Retain source-specific recipe, functional unit, scenario and geography. Current ecoinvent 3.12 cut-off background; deterministic source inventory; no exact reproduction claim…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.0 | 2026-11-16 | Initial CLIC BAT4EVER adaptation. Retain source-specific recipe, functional unit, scenario and geography. Current ecoinvent 3.12 cut-off background; deterministic source inventory; no exact reproduction claim beyond the recorded combined base-case climate comparison. | Current view |
Initial CLIC BAT4EVER adaptation. Retain source-specific recipe, functional unit, scenario and geography. Current ecoinvent 3.12 cut-off background; deterministic source inventory; no exact reproduction claim beyond the recorded combined base-case climate comparison.
Publication route
A curator validated the batch manifest and an editor authorized publication. This route does not imply that CLIC's current structured community-review checklist was completed.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content