Simons A, Bauer C. Life cycle assessment of the Evolutionary Power Reactor (EPR) and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy. 2012;226(3):427-444. doi:10.1177/0957650912440549
Dataset details
Classification, keywords, bookmarks and download counts.
Classification
Nuclear electricity (energy/electricity/nuclear)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0
Classification path:
Energy >
Electricity >
Nuclear electricity
Keywords
electricity
nuclear electricity
Bookmarking is available only on the latest published dataset record.
Metadata & sourcesMethods, scope, reference years, publications, contributors, projects and funding.
Source
Source documentation, background profiles and references.
Scientific journal publication
Simons, A., & Bauer, C. Life cycle assessment of the Evolutionary Power Reactor (EPR) and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy. 2012;226(3):427-444. https://doi.org/10.1177/0957650912440549
Background database
ecoinvent / 3.8
Background system model
cut-off
Biosphere database
ecoinvent / 3.8
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Reference years, modelling and allocation methods, contributors, publications, projects and funding.
Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
Source publication year
2012
Inventory reference year
Not specified
Foreground modelling approach
Not specified
Allocated product inventory
Not specified
Allocation or multifunctionality treatment
Not specified
Inventory contributions
Not specified
Methodology notes
The source is a 2012 prospective assessment of Swiss/French EPRs in 2030, using mixed-vintage fuel-cycle and infrastructure data. Table 4 distinguishes CH 1500 MWe from FR 1530 MWe; the common 1500-MWe description is not valid for the French scenario. The regional RER copy is not a separately tabulated source scenario. The paper's normal-operation boundaries exclude nuclear accidents. Equipment membership is traced only through unambiguous declared foreground links; underlying bills of materials and supplier/biosphere adaptations remain incompletely verified.
Intended application
Foreground modelling of the declared EPR hardware, fuel-cycle or electricity-production configuration.
Data origins
Literature
Other fields not yet completed (9)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type, System boundary, Included life cycle stages, Technology description, Use limitations
Publications (1)
Citation
Simons, A., Bauer, C. (2012). Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy 226(3), 427–444. https://doi.org/10.1177/0957650912440549
Title
Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Doi
10.1177/0957650912440549
Url
https://doi.org/10.1177/0957650912440549
Source type
Scientific journal
Publication year
2012
Relation
Primary source
Authors
Andrew Simons; Christian Bauer · 0000-0002-1083-9200
Projects (1)
Name
Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Url
https://doi.org/10.1177/0957650912440549
Relation
Source study
Funding (1)
Organization
Axpo Holding AG
Project
Life cycle assessment of the European pressurized reactor and the influence of different fuel cycle strategies
Evidence and qualifications (7)
Target field
data_origins
Origin
Editor verification
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Exact documented origins; no claim that every flow is measured.
Target field
intended_application
Origin
Editor verification
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Source-linked modelling context; no 2030 component year or measured manufacturer inventory is inferred.
DOI registration: title, publication dates and byline
Qualification
Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers.
Target field
publications
Origin
Editor verification
Source reference
https://api.ror.org/v2/organizations/03eh3y714
Source location
Organization identity and registered names
Qualification
Canonical institutional identity only. Preserve historical declared spelling, departments, attribution and funding relationships; identity verification alone does not verify an award or its scope.
Target field
publications
Origin
Editor verification
Source reference
https://doi.org/10.1177/0957650912440549
Source location
Original paper/SI byline; pinned DOI registration and institutional identity evidence
Qualification
Canonical primary and legacy citations are aligned without changing freeform source, inventory source text or inventory contributors. Publication year is not a measurement/reference year. EPR underlying inventories are acknowledged to Roberto Dones and Roth et al. (2009); component quantities are not all printed in the 2012 article. Preserve each declared source role and historical affiliation.
Target field
methodology_notes
Origin
Editor verification
Source reference
https://doi.org/10.1177/0957650912440549
Source location
Table 4, source scope and acknowledgements; foreground equipment paths
Qualification
Distinguish electricity, dedicated plant equipment and fuel-cycle supply roles. Only CH/FR electricity nodes receive the explicit 2030 model year. No component measurement year, capacity factor, numeric TRL or accident-risk result is inferred.
Target field
funding
Origin
Editor verification
Source reference
https://doi.org/10.1177/0957650912440549
Source location
Source funding statement immediately before acknowledgements
Qualification
Axpo Holding AG funded the cited study. The project declaration is labelled by the paper title with relation source_study; no formal grant/acronym is invented and no funding of the CLIC adaptation is inferred.
Technology characterizationScale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Early commercial
Design capacity
Not provided
Design capacity unit
Not provided
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scaleHigher is more mature.9: routine commercial deployment8: commercial, but still niche or scaling7: first-commercial or advanced demonstration6: engineering-scale demonstration5: pilot or large prototype4: bench or lab validated3: research-stage conceptTechnology readiness level
123456789
earlymature
1 to 5 scaleLower is better.1: strong market- or operating-data basis2: commercially plausible, but still somewhat specific3: partly representative, with modelling or adaptation bias4: pilot, proxy-based, scaled-up, or prospective5: weak representation of the real technology stateTechnological representativeness
12345
strongweak
1 to 5 scaleLower is better.1: geography matches the claimed scope well2: regionally credible, but broader or less exact3: generic regional or global proxy4: weak proxy or clear geographic mismatch5: geography is effectively unsupportedGeographical representativeness
12345
strongweak
1 to 5 scaleLower is better.1: current for that technology class2: slightly dated, but still good3: dated enough to need caution4: stale, pilot-era, or prospective relative to current practice5: clearly not representative of the current stateTemporal representativeness
12345
strongweak
Missing exchange uncertainty generation:
Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Acidification733.262
mol H+-Eq / unit
Climate change16681.2
kg CO2-Eq / unit
Freshwater ecotoxicity85167.2
CTUe / unit
Freshwater eutrophication20.9645
kg P-Eq / unit
Marine eutrophication19.644
kg N-Eq / unit
Terrestrial eutrophication199.983
mol N-Eq / unit
Human toxicity, cancer3.1759e-05
CTUh / unit
Human toxicity, non-cancer0.000511806
CTUh / unit
Ionising radiation10869.7
kBq U235-Eq / unit
Land use109671
dimensionless / unit
Ozone depletion0.00040607
kg CFC-11-Eq / unit
Particulate matter0.00139893
disease incidence / unit
Photochemical ozone formation104.356
kg NMVOC-Eq / unit
Resource use, fossils253273
MJ, net calorific value / unit
Resource use, minerals and metals0.163486
kg Sb-Eq / unit
Water use13990.2
m3 world Eq deprived / unit
Screening result
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Show all 16 indicator totals
Acidification733.262
mol H+-Eq / unit
Climate change16681.2
kg CO2-Eq / unit
Freshwater ecotoxicity85167.2
CTUe / unit
Freshwater eutrophication20.9645
kg P-Eq / unit
Marine eutrophication19.644
kg N-Eq / unit
Terrestrial eutrophication199.983
mol N-Eq / unit
Human toxicity, cancer3.1759e-05
CTUh / unit
Human toxicity, non-cancer0.000511806
CTUh / unit
Ionising radiation10869.7
kBq U235-Eq / unit
Land use109671
dimensionless / unit
Ozone depletion0.00040607
kg CFC-11-Eq / unit
Particulate matter0.00139893
disease incidence / unit
Photochemical ozone formation104.356
kg NMVOC-Eq / unit
Resource use, fossils253273
MJ, net calorific value / unit
Resource use, minerals and metals0.163486
kg Sb-Eq / unit
Water use13990.2
m3 world Eq deprived / unit
Calculation details
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-09-30 14:01 UTC. These screening results do not replace a reviewed comparative LCA.
Dataset contents
Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.
Outputs
Reference flow1 rowReference production exchanges extracted from the uploaded inventory.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
Transformer 12kV
CH
Transformer 12kV
Axpo NH 5b / year technologies
1
unit
Metadata (1)
Allocation
100
Reference flow
Inputs
Technosphere inputs11 rowsLinked foreground or background product inputs used by this dataset.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
heat production, natural gas, at industrial furnace low-NOx >100kW
Europe without Switzerland
heat, district or industrial, natural gas
Electricity/heat
1.44e+04
megajoule
Metadata (4)
Loc
14400
Product
heat, district or industrial, natural gas
Simapro name
Heat, natural gas, at industrial furnace low-NOx >100kW U
Uncertainty type
0
0.880044mol H+-Eq / unit
0.1% of total
1218.81kg CO2-Eq / unit
7.3% of total
3967.86CTUe / unit
4.7% of total
0.0370189kg P-Eq / unit
0.2% of total
0.380047kg N-Eq / unit
1.9% of total
3.81267mol N-Eq / unit
1.9% of total
1.3869e-07CTUh / unit
0.4% of total
2.4418e-06CTUh / unit
0.5% of total
44.6327kBq U235-Eq / unit
0.4% of total
976.527dimensionless / unit
0.9% of total
3.6612e-05kg CFC-11-Eq / unit
9.0% of total
4.4996e-06disease incidence / unit
0.3% of total
1.89013kg NMVOC-Eq / unit
1.8% of total
19625.6MJ, net calorific value / unit
7.7% of total
0.000364421kg Sb-Eq / unit
0.2% of total
241.757m3 world Eq deprived / unit
1.7% of total
BAFU:2025
market for copper, cathode
GLO
copper, cathode
Materials/fuels
774
kilogram
Metadata (4)
Loc
774
Product
copper, cathode
Simapro name
Copper, at regional storage U
Uncertainty type
0
702.777mol H+-Eq / unit
95.8% of total
6586.42kg CO2-Eq / unit
39.5% of total
56831.7CTUe / unit
66.7% of total
15.7366kg P-Eq / unit
75.1% of total
12.5223kg N-Eq / unit
63.7% of total
127.364mol N-Eq / unit
63.7% of total
6.9479e-06CTUh / unit
21.9% of total
0.000272993CTUh / unit
53.3% of total
2295.44kBq U235-Eq / unit
21.1% of total
51853.1dimensionless / unit
47.3% of total
0.000141909kg CFC-11-Eq / unit
34.9% of total
0.000832533disease incidence / unit
59.5% of total
73.7472kg NMVOC-Eq / unit
70.7% of total
86484.2MJ, net calorific value / unit
34.1% of total
0.0673473kg Sb-Eq / unit
41.2% of total
5883.97m3 world Eq deprived / unit
42.1% of total
BAFU:2025
market for electricity, medium voltage
CH
electricity, medium voltage
Electricity/heat
9980
kilowatt hour
Metadata (4)
Loc
9980
Product
electricity, medium voltage
Simapro name
Electricity, medium voltage, at grid U
Uncertainty type
0
1.76478mol H+-Eq / unit
0.2% of total
894.024kg CO2-Eq / unit
5.4% of total
2713.04CTUe / unit
3.2% of total
0.703415kg P-Eq / unit
3.4% of total
0.718598kg N-Eq / unit
3.7% of total
5.21903mol N-Eq / unit
2.6% of total
6.4554e-07CTUh / unit
2.0% of total
6.9224e-06CTUh / unit
1.4% of total
6782.68kBq U235-Eq / unit
62.4% of total
11042.2dimensionless / unit
10.1% of total
0.000104967kg CFC-11-Eq / unit
25.8% of total
4.1413e-05disease incidence / unit
3.0% of total
1.68418kg NMVOC-Eq / unit
1.6% of total
67149.7MJ, net calorific value / unit
26.5% of total
0.0026853kg Sb-Eq / unit
1.6% of total
5762.98m3 world Eq deprived / unit
41.2% of total
BAFU:2025
market for hot rolling, steel
GLO
hot rolling, steel
Materials/fuels
1040
kilogram
Metadata (4)
Loc
1040
Product
hot rolling, steel
Simapro name
Hot rolling, steel U
Uncertainty type
0
0.235633mol H+-Eq / unit
0.0% of total
172.771kg CO2-Eq / unit
1.0% of total
777.168CTUe / unit
0.9% of total
0.0290311kg P-Eq / unit
0.1% of total
0.0872837kg N-Eq / unit
0.4% of total
0.842936mol N-Eq / unit
0.4% of total
2.1007e-07CTUh / unit
0.7% of total
3.1405e-06CTUh / unit
0.6% of total
126.378kBq U235-Eq / unit
1.2% of total
521.829dimensionless / unit
0.5% of total
6.5906e-06kg CFC-11-Eq / unit
1.6% of total
8.1173e-06disease incidence / unit
0.6% of total
0.715406kg NMVOC-Eq / unit
0.7% of total
3771.14MJ, net calorific value / unit
1.5% of total
0.000163839kg Sb-Eq / unit
0.1% of total
147.278m3 world Eq deprived / unit
1.1% of total
BAFU:2025
market for kraft paper
RER
kraft paper
Materials/fuels
126
kilogram
Metadata (4)
Loc
126
Product
kraft paper
Simapro name
Kraft paper, unbleached, at plant U
Uncertainty type
0
0.843058mol H+-Eq / unit
0.1% of total
191.872kg CO2-Eq / unit
1.2% of total
1018.36CTUe / unit
1.2% of total
0.0513843kg P-Eq / unit
0.2% of total
0.277776kg N-Eq / unit
1.4% of total
2.56692mol N-Eq / unit
1.3% of total
1.2885e-07CTUh / unit
0.4% of total
1.5114e-06CTUh / unit
0.3% of total
64.532kBq U235-Eq / unit
0.6% of total
23901.5dimensionless / unit
21.8% of total
5.9279e-06kg CFC-11-Eq / unit
1.5% of total
1.9105e-05disease incidence / unit
1.4% of total
0.87152kg NMVOC-Eq / unit
0.8% of total
3159.44MJ, net calorific value / unit
1.2% of total
0.000458262kg Sb-Eq / unit
0.3% of total
96.9796m3 world Eq deprived / unit
0.7% of total
BAFU:2025
market for steel, low-alloyed
GLO
steel, low-alloyed
Materials/fuels
1040
kilogram
Metadata (4)
Loc
1040
Product
steel, low-alloyed
Simapro name
Steel, low-alloyed, at plant U
Uncertainty type
0
6.49257mol H+-Eq / unit
0.9% of total
2222.65kg CO2-Eq / unit
13.3% of total
5243.61CTUe / unit
6.2% of total
0.866694kg P-Eq / unit
4.1% of total
1.50105kg N-Eq / unit
7.6% of total
16.0176mol N-Eq / unit
8.0% of total
7.7415e-06CTUh / unit
24.4% of total
5.3052e-05CTUh / unit
10.4% of total
397.982kBq U235-Eq / unit
3.7% of total
5314.28dimensionless / unit
4.8% of total
2.1452e-05kg CFC-11-Eq / unit
5.3% of total
0.000151407disease incidence / unit
10.8% of total
6.84056kg NMVOC-Eq / unit
6.6% of total
19508.9MJ, net calorific value / unit
7.7% of total
0.0196294kg Sb-Eq / unit
12.0% of total
363.491m3 world Eq deprived / unit
2.6% of total
BAFU:2025
market for transport, freight train
CH
transport, freight train
Materials/fuels
2270
ton kilometer
Metadata (4)
Loc
2270
Product
transport, freight train
Simapro name
Transport, freight, rail U
Uncertainty type
0
0.0732055mol H+-Eq / unit
0.0% of total
7.90704kg CO2-Eq / unit
0.0% of total
60.7273CTUe / unit
0.1% of total
0.000631508kg P-Eq / unit
0.0% of total
0.0353536kg N-Eq / unit
0.2% of total
0.3847mol N-Eq / unit
0.2% of total
2.0895e-09CTUh / unit
0.0% of total
3.2573e-08CTUh / unit
0.0% of total
14.8411kBq U235-Eq / unit
0.1% of total
30.714dimensionless / unit
0.0% of total
5.8723e-07kg CFC-11-Eq / unit
0.1% of total
1.3964e-06disease incidence / unit
0.1% of total
0.111391kg NMVOC-Eq / unit
0.1% of total
210.206MJ, net calorific value / unit
0.1% of total
1.3460e-05kg Sb-Eq / unit
0.0% of total
261.52m3 world Eq deprived / unit
1.9% of total
BAFU:2025
market for transport, freight, lorry, unspecified
RER
transport, freight, lorry, unspecified
Materials/fuels
194
ton kilometer
Metadata (4)
Loc
194
Product
transport, freight, lorry, unspecified
Simapro name
Transport, van <3.5t U
Uncertainty type
0
1.03519mol H+-Eq / unit
0.1% of total
241.911kg CO2-Eq / unit
1.5% of total
680.383CTUe / unit
0.8% of total
0.0227486kg P-Eq / unit
0.1% of total
0.427421kg N-Eq / unit
2.2% of total
4.43005mol N-Eq / unit
2.2% of total
8.1213e-08CTUh / unit
0.3% of total
1.8381e-06CTUh / unit
0.4% of total
46.4881kBq U235-Eq / unit
0.4% of total
2215dimensionless / unit
2.0% of total
2.8356e-05kg CFC-11-Eq / unit
7.0% of total
7.6729e-06disease incidence / unit
0.5% of total
1.49383kg NMVOC-Eq / unit
1.4% of total
3487.2MJ, net calorific value / unit
1.4% of total
0.000576469kg Sb-Eq / unit
0.4% of total
280.367m3 world Eq deprived / unit
2.0% of total
BAFU:2025
sheet rolling, steel
RER
sheet rolling, steel
Materials/fuels
1930
kilogram
Metadata (3)
Loc
1930
Simapro name
Sheet rolling, steel U
Uncertainty type
0
1.8359mol H+-Eq / unit
0.3% of total
731.11kg CO2-Eq / unit
4.4% of total
2053.54CTUe / unit
2.4% of total
0.21155kg P-Eq / unit
1.0% of total
0.466803kg N-Eq / unit
2.4% of total
4.74345mol N-Eq / unit
2.4% of total
6.8373e-07CTUh / unit
2.2% of total
9.9950e-06CTUh / unit
2.0% of total
212.11kBq U235-Eq / unit
2.0% of total
2172.74dimensionless / unit
2.0% of total
1.2627e-05kg CFC-11-Eq / unit
3.1% of total
3.7700e-05disease incidence / unit
2.7% of total
2.17536kg NMVOC-Eq / unit
2.1% of total
8741.01MJ, net calorific value / unit
3.5% of total
0.000564928kg Sb-Eq / unit
0.3% of total
153.915m3 world Eq deprived / unit
1.1% of total
BAFU:2025
steel production, electric, low-alloyed
Europe without Switzerland and Austria
steel, low-alloyed
Materials/fuels
1930
kilogram
Metadata (4)
Loc
1930
Product
steel, low-alloyed
Simapro name
Steel, electric, un- and low-alloyed, at plant U
Uncertainty type
0
12.0487mol H+-Eq / unit
1.6% of total
4124.72kg CO2-Eq / unit
24.7% of total
9730.94CTUe / unit
11.4% of total
1.60838kg P-Eq / unit
7.7% of total
2.78559kg N-Eq / unit
14.2% of total
29.725mol N-Eq / unit
14.9% of total
1.4366e-05CTUh / unit
45.2% of total
9.8452e-05CTUh / unit
19.2% of total
738.562kBq U235-Eq / unit
6.8% of total
9862.08dimensionless / unit
9.0% of total
3.9810e-05kg CFC-11-Eq / unit
9.8% of total
0.000280976disease incidence / unit
20.1% of total
12.6945kg NMVOC-Eq / unit
12.2% of total
36203.9MJ, net calorific value / unit
14.3% of total
0.0364277kg Sb-Eq / unit
22.3% of total
674.555m3 world Eq deprived / unit
4.8% of total
BAFU:2025
wire drawing, copper
RER
wire drawing, copper
Materials/fuels
774
kilogram
Metadata (3)
Loc
774
Simapro name
Wire drawing, copper U
Uncertainty type
0
5.27576mol H+-Eq / unit
0.7% of total
289.019kg CO2-Eq / unit
1.7% of total
2089.88CTUe / unit
2.5% of total
1.69705kg P-Eq / unit
8.1% of total
0.44172kg N-Eq / unit
2.2% of total
4.87633mol N-Eq / unit
2.4% of total
8.1325e-07CTUh / unit
2.6% of total
6.1428e-05CTUh / unit
12.0% of total
146.099kBq U235-Eq / unit
1.3% of total
1781.43dimensionless / unit
1.6% of total
7.2310e-06kg CFC-11-Eq / unit
1.8% of total
1.4108e-05disease incidence / unit
1.0% of total
2.13152kg NMVOC-Eq / unit
2.0% of total
4931.74MJ, net calorific value / unit
1.9% of total
0.0352546kg Sb-Eq / unit
21.6% of total
123.387m3 world Eq deprived / unit
0.9% of total
BAFU:2025
Parameters0 source definitions · values, formulas and uncertainty.
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Supply-chain graph
Direct technosphere and natural-resource inputs appear on the left; emissions appear on the right.
Current datasetTechnosphere inputsEnvironmental resource inputsEmissions
1 CLIC node
and 11 background boundary nodes shown.
Direct inputs appear to the left of the current dataset, while emissions appear to the right. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Downloads & files
This historical version remains available for citation and download, but a newer public version is now current.
Add to download basket
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Activity and product names for transformer 12kV now use consistent catalogue spelling across the inventory and its supplier references. The physical recipe is unchanged.
Published · Latest
Show full version history table (2 versions)
Version
Published
Reason for this version
Link
Version 1.0.1
2026-11-03
Activity and product names for transformer 12kV now use consistent catalogue spelling across the inventory and its supplier references. The physical recipe is unchanged.
First published inventory; no earlier version is available for comparison.
Review & discussionPublication provenance, scientific review and community discussion.
Public review record
Curator-led bulk import. Public evidence is shown without participant
accounts, assignments, recommendations, or private editor notes.
Show reviewHide review
Publication route
Curator-led bulk import
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.