One charging-stand component with73kg steel,11kg copper,1kg aluminium and8.25kg grouped electronics, processing and36.05tkm freight. Historical stand also buys a whole laptop and17inch monitor; current published successor replaces these with industrial interface/controller equipment. Material grade, electronic function and transport basis remain qualified.
Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Current charger/stand retain generic-wrought aluminium50/1kg instead of AlLi, and the stand replaces one laptop/17inch screen with an industrial interface/controller. Five current predecessor/rationale hashes are verified. Do not reverse these corrections or infer that8.25kg grouped stand electronics includes the replaced computer/display. Historical recipes and later native zero-laptop entries remain distinct evidence. Charger freight120tkm is consistent with600kg×200km. Stand36.05tkm would imply180.25kg at200km versus the earlier100kg total, or360.5km if100kg is retained. This is an unresolved source/functional mass-distance convention; no isolated numerical candidate is proposed. Preserved HMI/PLC changes and stationary-battery chemistry further complicate direct rescaling.
Dataset details
Classification, keywords, bookmarks and download counts.
Classification
Trucks and lorries (transport/road/trucks)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0
Classification path:
Transport >
Road transport >
Trucks and lorries
Keywords
road transport
trucks and lorries
Bookmarking is available only on the latest published dataset record.
Metadata & sourcesMethods, scope, reference years, publications, contributors, projects and funding.
Source
Source documentation, background profiles and references.
Scientific journal publication
Supporting sources: Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0; Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf
Background database
ecoinvent / 3.8
Background system model
cut-off
Biosphere database
ecoinvent / 3.8
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Reference years, modelling and allocation methods, contributors, publications, projects and funding.
Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
Source publication year
Not specified
Inventory reference year
Not specified
Foreground modelling approach
Not specified
Allocated product inventory
Not specified
Allocation or multifunctionality treatment
Not specified
Inventory contributions
Not specified
Projects
Not specified
Funding
Not specified
Methodology notes
Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Current charger/stand retain generic-wrought aluminium50/1kg instead of AlLi, and the stand replaces one laptop/17inch screen with an industrial interface/controller. Five current predecessor/rationale hashes are verified. Do not reverse these corrections or infer that8.25kg grouped stand electronics includes the replaced computer/display. Historical recipes and later native zero-laptop entries remain distinct evidence. Charger freight120tkm is consistent with600kg×200km. Stand36.05tkm would imply180.25kg at200km versus the earlier100kg total, or360.5km if100kg is retained. This is an unresolved source/functional mass-distance convention; no isolated numerical candidate is proposed. Preserved HMI/PLC changes and stationary-battery chemistry further complicate direct rescaling.
Process type
Unit process: black box
System boundary
One charging-stand component with73kg steel,11kg copper,1kg aluminium and8.25kg grouped electronics, processing and36.05tkm freight. Historical stand also buys a whole laptop and17inch monitor; current published successor replaces these with industrial interface/controller equipment. Material grade, electronic function and transport basis remain qualified. Component/reference-unit manufacturing or aggregate installation only, as specified above. Vehicle operation, grid electricity delivery, efficiency, utilization and pervehicle allocation require separate service models.
Technology description
One charging-stand component with73kg steel,11kg copper,1kg aluminium and8.25kg grouped electronics, processing and36.05tkm freight. Historical stand also buys a whole laptop and17inch monitor; current published successor replaces these with industrial interface/controller equipment. Material grade, electronic function and transport basis remain qualified.
Intended application
Charging-infrastructure equipment reference for LCA, preserving the exact hardware/capacity/installation basis; not a direct delivered-electricity or vehicle-kilometre inventory.
Use limitations
Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Historical200kW charger uses4.3 equivalents of the600kg component, consistent with2×1290/600. ABB's1290kg row is rated100kW, while PSI2023 Table70 calls it200kW; the retained coefficient therefore includes an additional factor2 relative to the report's literal mass wording. Historical450kW scaling is(3×1340+500)/600=7.533333333. Manufacturer masses do not establish linear electrical-power scaling or the2000 electronics fraction in modern hardware. Current4675 replaces the legacy charger/stand/buffer assembly with1.2 integrated200kW hardware equivalents, one foundation and negative retirement/packaging demands. Current4676 buys the separate450kW station and WEEE demand; it no longer buys the old stand or buffer battery. Preserve these documented equipment-only replacements, including absence of dedicated stationary storage; do not restore Nansai's battery or treat the vehicle-model2020 climate/cycle as this component's measurement year. Recovered ABB Terra184 PEP ABBG-00284-V01.01-EN was issuedJuly2023, with395kg180kW hardware,25kg packaging,458kg foundation and10year reference life. Its functional unit is1kWh supplied in the defined operating scenario, whereas CLIC hardware outputs one equipment unit. Do not import EPD use-phase electricity, headline impacts or lifetime denominator into component manufacture. Current200kW hardware scales Terra184 material masses by200/180, giving438.888889kg total,430kg assigned classes and8.888889kg unassigned miscellaneous material. Keep that gap visible instead of normalizing it away. Source steel197kg×200/180 is split between ordinary steel and a grade430 shell within the same budget. Shell geometry/grade, material providers, wood500kg/m3 density and backgrounds are compiler assumptions, not a manufacturer200kW BOM. Source percentages use the full878kg station reference; do not treat them as percentages of395kg hardware. Current200kW installation retains12/10=1.2 expected hardware equivalents: the hardware's10years is sourced, installation12years is an inherited assumption. Foundation450kg concrete plus8kg steel is purchased/retired once, with2400kg/m3 concrete. WEEE−526.666667kg excludes packaging; wood−29.333333kg and PE−4kg cover all deliveries once. Preserve negative waste-service signs, paired background profiles and absence of double-counted foundation steel. No discrete replacement timetable or recycling credit is inferred. ABB PantoUP RevB January2021 confirms450kW from three1340kg150kW cabinets,7inch service HMI, and a separate pole/interface specification. It lists45kg contact dome and500kg control-box/pole rows; whether500kg includes the dome is not established here. Current station's500kg support recipe,10m cable, one shared2kg industrial HMI/PLC and aggregate4613.576kg retirement are engineering assumptions, not a certified full station BOM. Do not add a second onboard pantograph to offboard infrastructure without checking callers. Current charger/stand retain generic-wrought aluminium50/1kg instead of AlLi, and the stand replaces one laptop/17inch screen with an industrial interface/controller. Five current predecessor/rationale hashes are verified. Do not reverse these corrections or infer that8.25kg grouped stand electronics includes the replaced computer/display. Historical recipes and later native zero-laptop entries remain distinct evidence. Storage is currently800kWh nominal LFP manufacturing-capacity demand, not800kWh delivered electricity and not a source4000kg lead-acid inventory. Historical CONT market is a different technology basket. Chemistry, mass/capacity transfer, service life, cycling and current supplier boundary need original stationary-battery evidence before changes. Freight800tkm would imply200km at the earlier4tonne mass; that does not certify the LFP system mass. Charger freight120tkm is consistent with600kg×200km. Stand36.05tkm would imply180.25kg at200km versus the earlier100kg total, or360.5km if100kg is retained. This is an unresolved source/functional mass-distance convention; no isolated numerical candidate is proposed. Preserved HMI/PLC changes and stationary-battery chemistry further complicate direct rescaling. Historical2001 affiliations are supported by NIES annual bibliography: Nansai/Moriguchi at NIES, Tohno/Kasahara at Kyoto University, Kono at Toshiba International Fuel Cells. Nansai's primary ORCID is0000-0002-2449-1874; other unverified identifiers remain blank. Kyoto University (02kpeqv85) is not its museum; NIES (02hw5fp67) is not the Environment Ministry. Toshiba International Fuel Cells is not automatically the parent Toshiba corporation. ABB E-mobility and generic ABB publisher roles remain separate and no unrelated ABB-acronym ROR is assigned. Primary2001 publisher acknowledgment identifies JSPS Research for the Future project Distributed Autonomous Urban Energy System for Mitigating Environmental Impact,JSPS-RFTF97P01002; recovered2000 paper independently prints the same award. Canonical JSPS (00hhkn466) differs from its London office (02m7axw05). NIES's B-55 research-topic classification is not an interchangeable grant number or proof of funding of later CLIC/ABB adaptations. No funding/project declarations are propagated to these adapters. Crossmark explicitly reports no available data for the2001 DOI, rather than current status. Scoped DOI/title/erratum/supplement searches locate no authoritative correction, amended supplement or retraction; full2001 text and any historic supplementary inventory remain unavailable locally. Earlier2000 original and2021/2023 manufacturer documents are different sources, not published corrections of2001. ABB PEP issue/revision and PantoUP revision are pinned; later product revisions do not automatically amend this frozen equipment model.
Data origins
Literature
Other fields not yet completed (5)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Included life cycle stages
Publications (2)
Citation
Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0
Title
Life-cycle analysis of charging infrastructure for electric vehicles
Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf
Title
Life Cycle Analysis of Charging Infrastructure for Electric Vehicles
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Publisher-deposited registry /message/title, /message/published and /message/author
Qualification
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
NIES2003 annual bibliography, printed106; byline and historical external affiliations
Qualification
Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Historical2001 affiliations are supported by NIES annual bibliography: Nansai/Moriguchi at NIES, Tohno/Kasahara at Kyoto University, Kono at Toshiba International Fuel Cells. Nansai's primary ORCID is0000-0002-2449-1874; other unverified identifiers remain blank. Kyoto University (02kpeqv85) is not its museum; NIES (02hw5fp67) is not the Environment Ministry. Toshiba International Fuel Cells is not automatically the parent Toshiba corporation. ABB E-mobility and generic ABB publisher roles remain separate and no unrelated ABB-acronym ROR is assigned.
Original source tables and frozen revision rationale
Qualification
Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Current charger/stand retain generic-wrought aluminium50/1kg instead of AlLi, and the stand replaces one laptop/17inch screen with an industrial interface/controller. Five current predecessor/rationale hashes are verified. Do not reverse these corrections or infer that8.25kg grouped stand electronics includes the replaced computer/display. Historical recipes and later native zero-laptop entries remain distinct evidence. Charger freight120tkm is consistent with600kg×200km. Stand36.05tkm would imply180.25kg at200km versus the earlier100kg total, or360.5km if100kg is retained. This is an unresolved source/functional mass-distance convention; no isolated numerical candidate is proposed. Preserved HMI/PLC changes and stationary-battery chemistry further complicate direct rescaling.
Primary2001 publisher acknowledgment identifies JSPS Research for the Future project Distributed Autonomous Urban Energy System for Mitigating Environmental Impact,JSPS-RFTF97P01002; recovered2000 paper independently prints the same award. Canonical JSPS (00hhkn466) differs from its London office (02m7axw05). NIES's B-55 research-topic classification is not an interchangeable grant number or proof of funding of later CLIC/ABB adaptations. No funding/project declarations are propagated to these adapters.
Technology characterizationScale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Early commercial
Design capacity
100
Design capacity unit
kW
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
24 years
TRL scaleHigher is more mature.9: routine commercial deployment8: commercial, but still niche or scaling7: first-commercial or advanced demonstration6: engineering-scale demonstration5: pilot or large prototype4: bench or lab validated3: research-stage conceptTechnology readiness level
123456789
earlymature
1 to 5 scaleLower is better.1: strong market- or operating-data basis2: commercially plausible, but still somewhat specific3: partly representative, with modelling or adaptation bias4: pilot, proxy-based, scaled-up, or prospective5: weak representation of the real technology stateTechnological representativeness
12345
strongweak
1 to 5 scaleLower is better.1: geography matches the claimed scope well2: regionally credible, but broader or less exact3: generic regional or global proxy4: weak proxy or clear geographic mismatch5: geography is effectively unsupportedGeographical representativeness
12345
strongweak
1 to 5 scaleLower is better.1: current for that technology class2: slightly dated, but still good3: dated enough to need caution4: stale, pilot-era, or prospective relative to current practice5: clearly not representative of the current stateTemporal representativeness
12345
strongweak
Missing exchange uncertainty generation:
Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Acidification16.9156
mol H+-Eq / unit
Climate change1071.76
kg CO2-Eq / unit
Freshwater ecotoxicity6583.7
CTUe / unit
Freshwater eutrophication2.25297
kg P-Eq / unit
Marine eutrophication1.29253
kg N-Eq / unit
Terrestrial eutrophication12.2861
mol N-Eq / unit
Human toxicity, cancer7.7204e-06
CTUh / unit
Human toxicity, non-cancer7.2736e-05
CTUh / unit
Ionising radiation264.334
kBq U235-Eq / unit
Land use6228.62
dimensionless / unit
Ozone depletion4.5039e-05
kg CFC-11-Eq / unit
Particulate matter6.3231e-05
disease incidence / unit
Photochemical ozone formation4.53068
kg NMVOC-Eq / unit
Resource use, fossils14002
MJ, net calorific value / unit
Resource use, minerals and metals0.243136
kg Sb-Eq / unit
Water use8192.55
m3 world Eq deprived / unit
Screening result
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Show all 16 indicator totals
Acidification16.9156
mol H+-Eq / unit
Climate change1071.76
kg CO2-Eq / unit
Freshwater ecotoxicity6583.7
CTUe / unit
Freshwater eutrophication2.25297
kg P-Eq / unit
Marine eutrophication1.29253
kg N-Eq / unit
Terrestrial eutrophication12.2861
mol N-Eq / unit
Human toxicity, cancer7.7204e-06
CTUh / unit
Human toxicity, non-cancer7.2736e-05
CTUh / unit
Ionising radiation264.334
kBq U235-Eq / unit
Land use6228.62
dimensionless / unit
Ozone depletion4.5039e-05
kg CFC-11-Eq / unit
Particulate matter6.3231e-05
disease incidence / unit
Photochemical ozone formation4.53068
kg NMVOC-Eq / unit
Resource use, fossils14002
MJ, net calorific value / unit
Resource use, minerals and metals0.243136
kg Sb-Eq / unit
Water use8192.55
m3 world Eq deprived / unit
Calculation details
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-09-30 14:14 UTC. These screening results do not replace a reviewed comparative LCA.
Dataset contents
Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.
Outputs
Reference flow1 rowReference production exchanges extracted from the uploaded inventory.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
Charging stand
RER
Charging stand
1
unit
Metadata (1)
Tag
other
Reference flow
Inputs
Technosphere inputs10 rowsLinked foreground or background product inputs used by this dataset.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
market for copper, cathode
GLO
copper, cathode
11
kilogram
Metadata (1)
Tag
energy storage
9.98779mol H+-Eq / unit
59.0% of total
93.6054kg CO2-Eq / unit
8.7% of total
807.686CTUe / unit
12.3% of total
0.223647kg P-Eq / unit
9.9% of total
0.177966kg N-Eq / unit
13.8% of total
1.81008mol N-Eq / unit
14.7% of total
9.8743e-08CTUh / unit
1.3% of total
3.8798e-06CTUh / unit
5.3% of total
32.6226kBq U235-Eq / unit
12.3% of total
736.93dimensionless / unit
11.8% of total
2.0168e-06kg CFC-11-Eq / unit
4.5% of total
1.1832e-05disease incidence / unit
18.7% of total
1.04809kg NMVOC-Eq / unit
23.1% of total
1229.1MJ, net calorific value / unit
8.8% of total
0.000957132kg Sb-Eq / unit
0.4% of total
83.6223m3 world Eq deprived / unit
1.0% of total
BAFU:2025
metal working, average for aluminium product manufacturing
RER
metal working, average for aluminium product manufacturing
1
kilogram
Metadata (1)
Tag
other
0.0075851mol H+-Eq / unit
0.0% of total
2.15177kg CO2-Eq / unit
0.2% of total
7.62179CTUe / unit
0.1% of total
0.000698272kg P-Eq / unit
0.0% of total
0.00169456kg N-Eq / unit
0.1% of total
0.0131692mol N-Eq / unit
0.1% of total
1.7415e-09CTUh / unit
0.0% of total
2.7676e-08CTUh / unit
0.0% of total
1.10499kBq U235-Eq / unit
0.4% of total
10.4209dimensionless / unit
0.2% of total
5.9345e-08kg CFC-11-Eq / unit
0.1% of total
7.4856e-08disease incidence / unit
0.1% of total
0.00497465kg NMVOC-Eq / unit
0.1% of total
33.5883MJ, net calorific value / unit
0.2% of total
3.0876e-06kg Sb-Eq / unit
0.0% of total
56.3516m3 world Eq deprived / unit
0.7% of total
BAFU:2025
metal working, average for copper product manufacturing
RER
metal working, average for copper product manufacturing
11
kilogram
Metadata (1)
Tag
other
0.415208mol H+-Eq / unit
2.5% of total
15.7169kg CO2-Eq / unit
1.5% of total
162.365CTUe / unit
2.5% of total
0.135179kg P-Eq / unit
6.0% of total
0.0344981kg N-Eq / unit
2.7% of total
0.37247mol N-Eq / unit
3.0% of total
5.8790e-08CTUh / unit
0.8% of total
4.9772e-06CTUh / unit
6.8% of total
6.88479kBq U235-Eq / unit
2.6% of total
153.682dimensionless / unit
2.5% of total
5.3447e-07kg CFC-11-Eq / unit
1.2% of total
1.0616e-06disease incidence / unit
1.7% of total
0.105438kg NMVOC-Eq / unit
2.3% of total
240.245MJ, net calorific value / unit
1.7% of total
0.00287746kg Sb-Eq / unit
1.2% of total
540.813m3 world Eq deprived / unit
6.6% of total
BAFU:2025
metal working, average for chromium steel product manufacturing
RER
metal working, average for chromium steel product manufacturing
73
kilogram
Metadata (1)
Tag
other
0.542681mol H+-Eq / unit
3.2% of total
150.875kg CO2-Eq / unit
14.1% of total
566.938CTUe / unit
8.6% of total
0.0573474kg P-Eq / unit
2.5% of total
0.119132kg N-Eq / unit
9.2% of total
1.09304mol N-Eq / unit
8.9% of total
1.2182e-06CTUh / unit
15.8% of total
4.1357e-06CTUh / unit
5.7% of total
52.971kBq U235-Eq / unit
20.0% of total
908.027dimensionless / unit
14.6% of total
3.8925e-06kg CFC-11-Eq / unit
8.6% of total
6.4748e-06disease incidence / unit
10.2% of total
0.395385kg NMVOC-Eq / unit
8.7% of total
2089.46MJ, net calorific value / unit
14.9% of total
0.00216694kg Sb-Eq / unit
0.9% of total
3584.72m3 world Eq deprived / unit
43.8% of total
BAFU:2025
display production, liquid crystal, 17 inches
GLO
display, liquid crystal, 17 inches
1
unit
Metadata (1)
Tag
other
1.73729mol H+-Eq / unit
10.3% of total
197.041kg CO2-Eq / unit
18.4% of total
1542.45CTUe / unit
23.4% of total
0.547445kg P-Eq / unit
24.3% of total
0.204462kg N-Eq / unit
15.8% of total
2.18593mol N-Eq / unit
17.8% of total
6.2312e-07CTUh / unit
8.1% of total
1.3575e-05CTUh / unit
18.7% of total
40.6852kBq U235-Eq / unit
15.4% of total
1183.47dimensionless / unit
19.0% of total
1.2213e-05kg CFC-11-Eq / unit
27.1% of total
8.9805e-06disease incidence / unit
14.2% of total
0.748673kg NMVOC-Eq / unit
16.5% of total
2781.13MJ, net calorific value / unit
19.9% of total
0.0702122kg Sb-Eq / unit
28.9% of total
1647.61m3 world Eq deprived / unit
20.1% of total
BAFU:2025
electronics production, for control units
RER
electronics, for control units
8.25
kilogram
Metadata (1)
Tag
energy storage
1.47956mol H+-Eq / unit
8.7% of total
152.918kg CO2-Eq / unit
14.3% of total
1230.2CTUe / unit
18.7% of total
0.669794kg P-Eq / unit
29.7% of total
0.191667kg N-Eq / unit
14.8% of total
1.9715mol N-Eq / unit
16.0% of total
3.0846e-07CTUh / unit
4.0% of total
1.5464e-05CTUh / unit
21.3% of total
32.0968kBq U235-Eq / unit
12.1% of total
1087.18dimensionless / unit
17.5% of total
1.2828e-05kg CFC-11-Eq / unit
28.5% of total
6.5388e-06disease incidence / unit
10.3% of total
0.648177kg NMVOC-Eq / unit
14.3% of total
2090.69MJ, net calorific value / unit
14.9% of total
0.0880468kg Sb-Eq / unit
36.2% of total
1162.94m3 world Eq deprived / unit
14.2% of total
BAFU:2025
market for steel, chromium steel 18/8
GLO
steel, chromium steel 18/8
73
kilogram
Metadata (1)
Tag
other
1.63816mol H+-Eq / unit
9.7% of total
322.696kg CO2-Eq / unit
30.1% of total
1080.32CTUe / unit
16.4% of total
0.120317kg P-Eq / unit
5.3% of total
0.288806kg N-Eq / unit
22.3% of total
3.08469mol N-Eq / unit
25.1% of total
5.1998e-06CTUh / unit
67.4% of total
1.5805e-05CTUh / unit
21.7% of total
67.3424kBq U235-Eq / unit
25.5% of total
1317.2dimensionless / unit
21.1% of total
4.1332e-06kg CFC-11-Eq / unit
9.2% of total
2.3457e-05disease incidence / unit
37.1% of total
1.06485kg NMVOC-Eq / unit
23.5% of total
3770.84MJ, net calorific value / unit
26.9% of total
0.00886183kg Sb-Eq / unit
3.6% of total
70.6856m3 world Eq deprived / unit
0.9% of total
BAFU:2025
market for aluminium alloy, AlLi
GLO
aluminium alloy, AlLi
1
kilogram
Metadata (1)
Tag
other
0.0210305mol H+-Eq / unit
0.1% of total
7.02411kg CO2-Eq / unit
0.7% of total
14.6167CTUe / unit
0.2% of total
0.00133328kg P-Eq / unit
0.1% of total
0.00411287kg N-Eq / unit
0.3% of total
0.0325705mol N-Eq / unit
0.3% of total
5.3866e-09CTUh / unit
0.1% of total
8.4704e-08CTUh / unit
0.1% of total
2.83482kBq U235-Eq / unit
1.1% of total
16.7794dimensionless / unit
0.3% of total
8.6481e-08kg CFC-11-Eq / unit
0.2% of total
2.3415e-07disease incidence / unit
0.4% of total
0.0119431kg NMVOC-Eq / unit
0.3% of total
75.9561MJ, net calorific value / unit
0.5% of total
8.7664e-06kg Sb-Eq / unit
0.0% of total
28.373m3 world Eq deprived / unit
0.3% of total
BAFU:2025
market for transport, freight, lorry >32 metric ton, EURO6
RER
transport, freight, lorry >32 metric ton, EURO6
36.05
ton kilometer
Metadata (1)
Tag
other
0.0217366mol H+-Eq / unit
0.1% of total
6.214kg CO2-Eq / unit
0.6% of total
16.1095CTUe / unit
0.2% of total
0.000608811kg P-Eq / unit
0.0% of total
0.00814462kg N-Eq / unit
0.6% of total
0.0873385mol N-Eq / unit
0.7% of total
2.2281e-09CTUh / unit
0.0% of total
4.9091e-08CTUh / unit
0.1% of total
0.726632kBq U235-Eq / unit
0.3% of total
27.2849dimensionless / unit
0.4% of total
2.1249e-07kg CFC-11-Eq / unit
0.5% of total
1.8909e-07disease incidence / unit
0.3% of total
0.0349125kg NMVOC-Eq / unit
0.8% of total
91.0113MJ, net calorific value / unit
0.6% of total
1.5779e-05kg Sb-Eq / unit
0.0% of total
7.92472m3 world Eq deprived / unit
0.1% of total
BAFU:2025
computer production, laptop
GLO
computer, laptop
1
unit
Metadata (1)
Tag
other
1.06451mol H+-Eq / unit
6.3% of total
123.515kg CO2-Eq / unit
11.5% of total
1155.39CTUe / unit
17.5% of total
0.4966kg P-Eq / unit
22.0% of total
0.262045kg N-Eq / unit
20.3% of total
1.63526mol N-Eq / unit
13.3% of total
2.0383e-07CTUh / unit
2.6% of total
1.4738e-05CTUh / unit
20.3% of total
27.0649kBq U235-Eq / unit
10.2% of total
787.654dimensionless / unit
12.6% of total
9.0631e-06kg CFC-11-Eq / unit
20.1% of total
4.3880e-06disease incidence / unit
6.9% of total
0.468233kg NMVOC-Eq / unit
10.3% of total
1600.01MJ, net calorific value / unit
11.4% of total
0.0699862kg Sb-Eq / unit
28.8% of total
1009.51m3 world Eq deprived / unit
12.3% of total
BAFU:2025
Parameters0 source definitions · values, formulas and uncertainty.
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Supply-chain graph
Direct technosphere and natural-resource inputs appear on the left; emissions appear on the right.
Current datasetTechnosphere inputsEnvironmental resource inputsEmissions
1 CLIC node
and 10 background boundary nodes shown.
Direct inputs appear to the left of the current dataset, while emissions appear to the right. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Downloads & files
This historical version remains available for citation and download, but a newer public version is now current.
Add to download basket
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Updates the vehicle inventory to the documented carculator_truck 0.5.2 recipe. Model inputs, emissions and associated documentation follow the adopted source model where they differ…
Published · Latest
Show full version history table (2 versions)
Version
Published
Reason for this version
Link
Version 1.0.1
2026-11-03
Updates the vehicle inventory to the documented carculator_truck 0.5.2 recipe. Model inputs, emissions and associated documentation follow the adopted source model where they differ from the previous public version.
First published inventory; no earlier version is available for comparison.
Review & discussionPublication provenance, scientific review and community discussion.
Public review record
Curator-led bulk import. Public evidence is shown without participant
accounts, assignments, recommendations, or private editor notes.
Show reviewHide review
Publication route
Curator-led bulk import
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.