Description
Manufacturing reference for one stack of a nominal 1 MWe PEM water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.
Hydrogen via electrolysis
Reference product electrolyzer, 1MWe, PEM, Stack RER
Stable dataset identity
electrolyzer-production-1mwe-pem-stack
1.0.1Published inventory
Process description and catalog context. View scientific metadata
Manufacturing reference for one stack of a nominal 1 MWe PEM water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.
Classification, keywords, bookmarks and download counts.
Classification path: Energy > Hydrogen > Hydrogen via electrolysis
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-03 09:12 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
electrolyzer production, 1MWe, PEM, stack
RER
|
electrolyzer, 1MWe, PEM, Stack
|
1
|
unit | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
market for aluminium, wrought alloy
GLO
|
aluminium, wrought alloy
|
27
|
kilogram |
0.651856
mol H+-Eq / unit
0.0% of total
134.302
kg CO2-Eq / unit
0.1% of total
396.215
CTUe / unit
0.1% of total
0.0354517
kg P-Eq / unit
0.0% of total
0.119102
kg N-Eq / unit
0.2% of total
0.967596
mol N-Eq / unit
0.2% of total
1.5194e-07
CTUh / unit
0.2% of total
2.5014e-06
CTUh / unit
0.1% of total
73.2084
kBq U235-Eq / unit
0.3% of total
251.92
dimensionless / unit
0.1% of total
2.3280e-06
kg CFC-11-Eq / unit
0.0% of total
7.3267e-06
disease incidence / unit
0.2% of total
0.356079
kg NMVOC-Eq / unit
0.1% of total
2066.57
MJ, net calorific value / unit
0.2% of total
0.000115272
kg Sb-Eq / unit
0.0% of total
922.65
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for sheet rolling, aluminium
GLO
|
sheet rolling, aluminium
|
27
|
kilogram |
0.0321641
mol H+-Eq / unit
0.0% of total
11.8707
kg CO2-Eq / unit
0.0% of total
36.9166
CTUe / unit
0.0% of total
0.00457629
kg P-Eq / unit
0.0% of total
0.00688766
kg N-Eq / unit
0.0% of total
0.0584797
mol N-Eq / unit
0.0% of total
8.3701e-09
CTUh / unit
0.0% of total
9.9413e-08
CTUh / unit
0.0% of total
7.17451
kBq U235-Eq / unit
0.0% of total
41.795
dimensionless / unit
0.0% of total
2.9693e-07
kg CFC-11-Eq / unit
0.0% of total
2.6693e-07
disease incidence / unit
0.0% of total
0.0366269
kg NMVOC-Eq / unit
0.0% of total
217.163
MJ, net calorific value / unit
0.0% of total
9.5915e-06
kg Sb-Eq / unit
0.0% of total
23.4551
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for titanium
GLO
|
titanium
|
528
|
kilogram |
12.9971
mol H+-Eq / unit
0.4% of total
2197.86
kg CO2-Eq / unit
2.2% of total
7441.67
CTUe / unit
1.6% of total
1.19307
kg P-Eq / unit
1.5% of total
2.40428
kg N-Eq / unit
4.5% of total
24.2427
mol N-Eq / unit
4.7% of total
7.6811e-07
CTUh / unit
0.8% of total
3.7286e-05
CTUh / unit
1.6% of total
827.249
kBq U235-Eq / unit
3.3% of total
5859.8
dimensionless / unit
1.6% of total
0.000550487
kg CFC-11-Eq / unit
1.2% of total
4.4523e-05
disease incidence / unit
1.1% of total
7.15793
kg NMVOC-Eq / unit
2.1% of total
45722.8
MJ, net calorific value / unit
3.4% of total
0.00840907
kg Sb-Eq / unit
0.4% of total
2.40062
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
PFSA membrane, EW1100, dry acid form, engineering reference
|
16
|
kilogram |
1.36681
mol H+-Eq / unit
0.0% of total
1608.75
kg CO2-Eq / unit
1.6% of total
2624.34
CTUe / unit
0.6% of total
0.0724521
kg P-Eq / unit
0.1% of total
0.162531
kg N-Eq / unit
0.3% of total
1.62323
mol N-Eq / unit
0.3% of total
2.4349e-06
CTUh / unit
2.6% of total
6.4405e-06
CTUh / unit
0.3% of total
80.4767
kBq U235-Eq / unit
0.3% of total
881.362
dimensionless / unit
0.2% of total
0.0437658
kg CFC-11-Eq / unit
96.5% of total
1.1905e-05
disease incidence / unit
0.3% of total
0.877931
kg NMVOC-Eq / unit
0.3% of total
6329.01
MJ, net calorific value / unit
0.5% of total
0.00180182
kg Sb-Eq / unit
0.1% of total
381.971
m3 world Eq deprived / unit
0.0% of total
|
||
|
market for carbon black
GLO
|
carbon black
|
4.5
|
kilogram |
0.0411523
mol H+-Eq / unit
0.0% of total
14.9268
kg CO2-Eq / unit
0.0% of total
105.96
CTUe / unit
0.0% of total
0.0005297
kg P-Eq / unit
0.0% of total
0.00487704
kg N-Eq / unit
0.0% of total
0.0477441
mol N-Eq / unit
0.0% of total
1.6409e-09
CTUh / unit
0.0% of total
5.6232e-08
CTUh / unit
0.0% of total
0.313905
kBq U235-Eq / unit
0.0% of total
40.233
dimensionless / unit
0.0% of total
4.6093e-08
kg CFC-11-Eq / unit
0.0% of total
1.3406e-06
disease incidence / unit
0.0% of total
0.0565841
kg NMVOC-Eq / unit
0.0% of total
409.693
MJ, net calorific value / unit
0.0% of total
1.8243e-05
kg Sb-Eq / unit
0.0% of total
6.15865
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
iridium
|
0.8
|
kilogram |
165.715
mol H+-Eq / unit
5.4% of total
24693.7
kg CO2-Eq / unit
24.7% of total
53178.3
CTUe / unit
11.4% of total
12.7134
kg P-Eq / unit
16.1% of total
13.5438
kg N-Eq / unit
25.2% of total
133.204
mol N-Eq / unit
26.1% of total
9.8803e-06
CTUh / unit
10.6% of total
7.7639e-05
CTUh / unit
3.4% of total
1829.38
kBq U235-Eq / unit
7.2% of total
38780.7
dimensionless / unit
10.8% of total
0.000110575
kg CFC-11-Eq / unit
0.2% of total
0.000475259
disease incidence / unit
11.3% of total
43.0135
kg NMVOC-Eq / unit
12.8% of total
251178
MJ, net calorific value / unit
18.8% of total
0.00581755
kg Sb-Eq / unit
0.3% of total
148675
m3 world Eq deprived / unit
7.4% of total
|
||
|
market for platinum
GLO
|
platinum
|
0.75
|
kilogram |
2731.89
mol H+-Eq / unit
88.9% of total
7745.38
kg CO2-Eq / unit
7.8% of total
204890
CTUe / unit
43.9% of total
41.8855
kg P-Eq / unit
52.9% of total
7.24206
kg N-Eq / unit
13.4% of total
55.1452
mol N-Eq / unit
10.8% of total
4.2630e-05
CTUh / unit
45.5% of total
0.00133443
CTUh / unit
57.7% of total
5351.45
kBq U235-Eq / unit
21.1% of total
59571.6
dimensionless / unit
16.6% of total
0.000266909
kg CFC-11-Eq / unit
0.6% of total
0.00224216
disease incidence / unit
53.4% of total
186.969
kg NMVOC-Eq / unit
55.7% of total
141456
MJ, net calorific value / unit
10.6% of total
1.77826
kg Sb-Eq / unit
93.2% of total
3083.26
m3 world Eq deprived / unit
0.2% of total
BAFU:2025
|
|
|
market for carbon black
GLO
|
carbon black
|
4.5
|
kilogram |
0.0411523
mol H+-Eq / unit
0.0% of total
14.9268
kg CO2-Eq / unit
0.0% of total
105.96
CTUe / unit
0.0% of total
0.0005297
kg P-Eq / unit
0.0% of total
0.00487704
kg N-Eq / unit
0.0% of total
0.0477441
mol N-Eq / unit
0.0% of total
1.6409e-09
CTUh / unit
0.0% of total
5.6232e-08
CTUh / unit
0.0% of total
0.313905
kBq U235-Eq / unit
0.0% of total
40.233
dimensionless / unit
0.0% of total
4.6093e-08
kg CFC-11-Eq / unit
0.0% of total
1.3406e-06
disease incidence / unit
0.0% of total
0.0565841
kg NMVOC-Eq / unit
0.0% of total
409.693
MJ, net calorific value / unit
0.0% of total
1.8243e-05
kg Sb-Eq / unit
0.0% of total
6.15865
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for copper, cathode
GLO
|
copper, cathode
|
4.5
|
kilogram |
4.08592
mol H+-Eq / unit
0.1% of total
38.2931
kg CO2-Eq / unit
0.0% of total
330.417
CTUe / unit
0.1% of total
0.0914918
kg P-Eq / unit
0.1% of total
0.0728043
kg N-Eq / unit
0.1% of total
0.740488
mol N-Eq / unit
0.1% of total
4.0395e-08
CTUh / unit
0.0% of total
1.5872e-06
CTUh / unit
0.1% of total
13.3456
kBq U235-Eq / unit
0.1% of total
301.472
dimensionless / unit
0.1% of total
8.2505e-07
kg CFC-11-Eq / unit
0.0% of total
4.8403e-06
disease incidence / unit
0.1% of total
0.428763
kg NMVOC-Eq / unit
0.1% of total
502.815
MJ, net calorific value / unit
0.0% of total
0.000391554
kg Sb-Eq / unit
0.0% of total
34.2091
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for sheet rolling, copper
GLO
|
sheet rolling, copper
|
4.5
|
kilogram |
0.0296601
mol H+-Eq / unit
0.0% of total
1.35966
kg CO2-Eq / unit
0.0% of total
11.1487
CTUe / unit
0.0% of total
0.00961647
kg P-Eq / unit
0.0% of total
0.00235988
kg N-Eq / unit
0.0% of total
0.0266927
mol N-Eq / unit
0.0% of total
4.4593e-09
CTUh / unit
0.0% of total
3.5478e-07
CTUh / unit
0.0% of total
0.481564
kBq U235-Eq / unit
0.0% of total
8.0794
dimensionless / unit
0.0% of total
3.3471e-08
kg CFC-11-Eq / unit
0.0% of total
7.6152e-08
disease incidence / unit
0.0% of total
0.0101226
kg NMVOC-Eq / unit
0.0% of total
21.3013
MJ, net calorific value / unit
0.0% of total
0.000204552
kg Sb-Eq / unit
0.0% of total
0.582284
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for sheet rolling, chromium steel
GLO
|
sheet rolling, chromium steel
|
100
|
kilogram |
0.216766
mol H+-Eq / unit
0.0% of total
42.9588
kg CO2-Eq / unit
0.0% of total
782.213
CTUe / unit
0.2% of total
0.0213915
kg P-Eq / unit
0.0% of total
0.0399306
kg N-Eq / unit
0.1% of total
0.424344
mol N-Eq / unit
0.1% of total
3.9091e-07
CTUh / unit
0.4% of total
1.2951e-06
CTUh / unit
0.1% of total
23.0286
kBq U235-Eq / unit
0.1% of total
234.154
dimensionless / unit
0.1% of total
8.3766e-07
kg CFC-11-Eq / unit
0.0% of total
2.4126e-06
disease incidence / unit
0.1% of total
0.155339
kg NMVOC-Eq / unit
0.0% of total
687.725
MJ, net calorific value / unit
0.1% of total
0.000668847
kg Sb-Eq / unit
0.0% of total
13.43
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for steel, chromium steel 18/8, hot rolled
GLO
|
steel, chromium steel 18/8, hot rolled
|
100
|
kilogram |
0.216766
mol H+-Eq / unit
0.0% of total
42.9588
kg CO2-Eq / unit
0.0% of total
782.213
CTUe / unit
0.2% of total
0.0213915
kg P-Eq / unit
0.0% of total
0.0399306
kg N-Eq / unit
0.1% of total
0.424344
mol N-Eq / unit
0.1% of total
3.9091e-07
CTUh / unit
0.4% of total
1.2951e-06
CTUh / unit
0.1% of total
23.0286
kBq U235-Eq / unit
0.1% of total
234.154
dimensionless / unit
0.1% of total
8.3766e-07
kg CFC-11-Eq / unit
0.0% of total
2.4126e-06
disease incidence / unit
0.1% of total
0.155339
kg NMVOC-Eq / unit
0.0% of total
687.725
MJ, net calorific value / unit
0.1% of total
0.000668847
kg Sb-Eq / unit
0.0% of total
13.43
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for synthetic rubber
GLO
|
synthetic rubber
|
4.8
|
kilogram |
0.0452796
mol H+-Eq / unit
0.0% of total
13.7582
kg CO2-Eq / unit
0.0% of total
83.6536
CTUe / unit
0.0% of total
0.00300888
kg P-Eq / unit
0.0% of total
0.00786375
kg N-Eq / unit
0.0% of total
0.079859
mol N-Eq / unit
0.0% of total
5.8623e-09
CTUh / unit
0.0% of total
1.7121e-07
CTUh / unit
0.0% of total
2.91692
kBq U235-Eq / unit
0.0% of total
66.4629
dimensionless / unit
0.0% of total
3.0305e-07
kg CFC-11-Eq / unit
0.0% of total
7.7342e-07
disease incidence / unit
0.0% of total
0.057319
kg NMVOC-Eq / unit
0.0% of total
390.573
MJ, net calorific value / unit
0.0% of total
9.6505e-05
kg Sb-Eq / unit
0.0% of total
21.1743
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market group for electricity, low voltage
GLO
|
electricity, low voltage
|
1.04e+05
|
kilowatt hour |
156.82
mol H+-Eq / unit
5.1% of total
63297
kg CO2-Eq / unit
63.4% of total
195507
CTUe / unit
41.9% of total
23.1295
kg P-Eq / unit
29.2% of total
30.1934
kg N-Eq / unit
56.1% of total
293.368
mol N-Eq / unit
57.5% of total
3.6914e-05
CTUh / unit
39.4% of total
0.000851115
CTUh / unit
36.8% of total
17120.1
kBq U235-Eq / unit
67.5% of total
252664
dimensionless / unit
70.4% of total
0.000649101
kg CFC-11-Eq / unit
1.4% of total
0.00140735
disease incidence / unit
33.5% of total
96.3719
kg NMVOC-Eq / unit
28.7% of total
886259
MJ, net calorific value / unit
66.3% of total
0.111821
kg Sb-Eq / unit
5.9% of total
1.8571e+06
m3 world Eq deprived / unit
92.4% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
11 CLIC nodes and 11 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
First published inventory; no earlier version is available for comparison.
SupersededRepresent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-11-03 | Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses. | Current view |
| Version 1.0.0 Superseded | Published 2026-07-15 | First published inventory; no earlier version is available for comparison. | Open version |
Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses.
The previous monomer and generic PGM inputs are replaced without changing the 16 kg membrane or 0.8 kg iridium quantities. Product identity and production boundary are corrected; no new catalyst-performance, membrane-lifetime or operating-efficiency improvement is assumed.
Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| perfluorosulfonic acid membrane production, ew1100, engineering reference (technosphere / GLO / kilogram) | Amount | Not present | 16 kilogram | Represent the stack’s 16 kg ion-exchange membrane as finished PFSA membrane rather than tetrafluoroethylene monomer. The shared dry, unreinforced EW1100 reference includes polymer/membrane manufacture while retaining the membrane quantity. It is an engineering grade proxy, not proof that every PEM stack uses an identical commercial membrane. |
| iridium production, economic allocation, proxy (technosphere / ZA / kilogram) | Amount | Not present | 0.8 kilogram | The iridium entry supplies the material, process or treatment required by the revised reference. Membrane-polymer manufacture belongs upstream of the cell or stack using the membrane, while assembly remains at the parent system. The membrane boundary now supplies finished perfluorosulfonic material rather than treating a fluorinated monomer as the finished membrane. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for tetrafluoroethylene (technosphere / GLO / kilogram) | Amount | 16 kilogram | Not present | Represent the stack’s 16 kg ion-exchange membrane as finished PFSA membrane rather than tetrafluoroethylene monomer. The shared dry, unreinforced EW1100 reference includes polymer/membrane manufacture while retaining the membrane quantity. It is an engineering grade proxy, not proof that every PEM stack uses an identical commercial membrane. |
| platinum group metal, extraction and refinery operations (technosphere / ZA / kilogram) | Amount | 0.8 kilogram | Not present | The former iridium entry is superseded by the revised product/component boundary. Membrane-polymer manufacture belongs upstream of the cell or stack using the membrane, while assembly remains at the parent system. The membrane boundary now supplies finished perfluorosulfonic material rather than treating a fluorinated monomer as the finished membrane. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| electrolyzer production, 1MWe, PEM, stack (production / RER / unit) | Name | electrolyzer production, 1MWe, PEM, Stack | electrolyzer production, 1MWe, PEM, stack | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Version metadata | Commercial maturity stage | early_commercial | mature_commercial | No explanation was recorded for this change. |
| Version metadata | Inventory evidence types | Literature; Engineering estimate | Literature; Engineering estimate; Proxy | |
| Version metadata | Geographical representativeness | 2 | 3 | |
| Version metadata | Methodology and allocation explanation | The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. | Source model Gerloff (2021) compares 1 MWe AEC, PEM and SOEC systems under German 2019, 2030, 2050 and renewable-electricity scenarios. The study uses ecoinvent 3.5 cutoff, European/German suppliers, Umberto+, ILCD 2.0 midpoint 2018 and IPCC 2013 GWP. CLIC uses separately declared 3.9 background/biosphere profiles and later material, lifetime and utility adaptations. Publication and scenario years do not date measured inputs. Manufacturing basis The reference is one manufactured stack, including 103890.7681 kWh assembly electricity. Processing services are separate from installed material mass. Stack assembly electricity is the source's three-stack total divided by three. Lifetime accounting The paper assumes 20 years at 8000 h/year and numerically counts three stacks, despite wording about three replacements. SM1 manufacturing-energy totals also include three stacks; the CLIC stack-manufacturing reference uses one third. Operating models separately purchase four PEM/AEC stacks or eight SOEC stacks with corresponding signed retirement. The retrieved IndWEDe document is the Kurzfassung, whereas the cited p. 178 belongs to an unrecovered full report. Selected lifetimes are not independently verified from that page. Materials The recipe includes 16 kg PFSA, 0.8 kg iridium and 0.75 kg platinum per stack. Iridium uses a separately modelled economic-allocation production proxy. |
|
| Version metadata | Plant lifetime | 20 | Not set | |
| Version metadata | Contributors, publications, projects and supporting evidence | Evidence: 1. Origin: source_import Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: data_origins Evidence: 2. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 2. Source location: source Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: source_import Evidence: 3. Target field: data_origins Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 3. Source location: description Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: source_import Evidence: 4. Target field: included_life_cycle_stages Evidence: 4. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage. Evidence: 4. Source location: name Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: source_import Evidence: 5. Target field: publications Evidence: 5. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 5. Source location: source Evidence: 5. Source reference: Existing published CLIC inventory documentation Evidence: 6. Origin: editor_verification Evidence: 6. Target field: publications Evidence: 6. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 6. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 6. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759 Evidence: 7. Origin: editor_verification Evidence: 7. Target field: publications Evidence: 7. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles. Evidence: 7. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Evidence: 8. Origin: editor_verification Evidence: 8. Target field: methodology_notes Evidence: 8. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Evidence: 8. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci Evidence: 8. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Publications: 1. Doi: 10.1016/j.est.2021.102759 Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production Publications: 1. Scientific authors: 1. Name: Niklas Gerloff Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2021 Publications: 2. Doi: Not set Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland Publications: 2. Scientific authors: 1. Name: Tom Smolinka Publications: 2. Scientific authors: 1. Orcid: Not set Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe Publications: 2. Scientific authors: 2. Orcid: Not set Publications: 2. Scientific authors: 3. Name: Philip Sterchele Publications: 2. Scientific authors: 3. Orcid: Not set Publications: 2. Scientific authors: 4. Name: Andreas Palzer Publications: 2. Scientific authors: 4. Orcid: Not set Publications: 2. Scientific authors: 5. Name: Franz Lehner Publications: 2. Scientific authors: 5. Orcid: Not set Publications: 2. Scientific authors: 6. Name: Malte Jansen Publications: 2. Scientific authors: 6. Orcid: Not set Publications: 2. Scientific authors: 7. Name: Steffen Kiemel Publications: 2. Scientific authors: 7. Orcid: Not set Publications: 2. Scientific authors: 8. Name: Robert Miehe Publications: 2. Scientific authors: 8. Orcid: Not set Publications: 2. Scientific authors: 9. Name: Sylvia Wahren Publications: 2. Scientific authors: 9. Orcid: Not set Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann Publications: 2. Scientific authors: 10. Orcid: Not set Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: technical_report Publications: 2. Publication year: 2018 |
Evidence: 1. Origin: source_import Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: data_origins Evidence: 2. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 2. Source location: description Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: source_import Evidence: 3. Target field: data_origins Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: source_import Evidence: 4. Target field: included_life_cycle_stages Evidence: 4. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage. Evidence: 4. Source location: name Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: source_import Evidence: 5. Target field: use_limitations Evidence: 5. Qualification: Copied version-specific scientific qualification; it remains applicable to this exact reconstruction and is not a claim about the source paper. Evidence: 5. Source location: description Evidence: 5. Source reference: Existing published CLIC inventory documentation Evidence: 6. Origin: source_import Evidence: 6. Target field: publications Evidence: 6. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 6. Source location: source Evidence: 6. Source reference: Existing published CLIC inventory documentation Evidence: 7. Origin: editor_verification Evidence: 7. Target field: publications Evidence: 7. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 7. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 7. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759 Evidence: 8. Origin: editor_verification Evidence: 8. Target field: publications Evidence: 8. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles. Evidence: 8. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers Evidence: 8. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Evidence: 9. Origin: editor_verification Evidence: 9. Target field: methodology_notes Evidence: 9. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Evidence: 9. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci Evidence: 9. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Evidence: 10. Origin: editor_verification Evidence: 10. Target field: technology_description Evidence: 10. Qualification: Technical-characterisation review TC-2057. Design capacity: 1.000000. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 10. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 10. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: technology_description Evidence: 11. Qualification: Technical-characterisation review TC-2057. Design capacity unit: MW. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 11. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 11. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 12. Origin: editor_verification Evidence: 12. Target field: technology_description Evidence: 12. Qualification: Technical-characterisation review TC-2057. Capacity factor (%): Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 12. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 12. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: technology_description Evidence: 13. Qualification: Technical-characterisation review TC-2057. Annual production volume: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 13. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 13. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-2057. Annual production volume unit: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 14. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-2057. Annual production volume year: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 15. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-2057. Plant or represented-asset lifetime (years): Unspecified. Basis: PEM stack is replaced within the 20 years ystem model. The selected compiler stack life is5.5 year s, not20 year s. The integer field cannot store5.5losslessly; clear the wrong system-life scalar and retain explicit fractional stack context. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 16. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-2057. Commercial maturity stage: mature_commercial. Basis: Curator assessment of established alkaline/PEM manufacturing and hydrogen-production routes, corroborated by primary energy-agency context. Numeric9is not assigned by Gerloffto each exact CLIC object and does not validate the model material, pressure, water or lifetime assumptions. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 17. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-2057. Technology readiness level: 9. Basis: Curator assessment of established alkaline/PEM manufacturing and hydrogen-production routes, corroborated by primary energy-agency context. Numeric9is not assigned by Gerloffto each exact CLIC object and does not validate the model material, pressure, water or lifetime assumptions. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 18. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 19. Origin: editor_verification Evidence: 19. Target field: technology_description Evidence: 19. Qualification: Technical-characterisation review TC-2057. Technological representativeness: 4. Basis: Curator assessment of a hybrid literature/compiler model with selected updated membrane/alloy/PCS/drive and utility assumptions. Established route maturity does not make exact bill and performance representative measured production. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 19. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 19. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 20. Origin: editor_verification Evidence: 20. Target field: technology_description Evidence: 20. Qualification: Technical-characterisation review TC-2057. Geographical representativeness: 3. Basis: Curator assessment of generic regional supplier/material references and scenario electricity choices, not a matched or production-weighted factory population. Selected supply scenarios do not independently establish equipment manufacturing geography. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 20. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 20. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 21. Origin: editor_verification Evidence: 21. Target field: technology_description Evidence: 21. Qualification: Technical-characterisation review TC-2057. Temporal representativeness: 4. Basis: Curator assessment of mixed historical source materials, IndWEDe/manufacturer scenario assumptions and later compiler adaptations.2019/2030/2050electricity scenarios,2021publication and current equipment availability are not full-inventory observation periods. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 21. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 21. Source reference: https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Doi: 10.1016/j.est.2021.102759 Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production Publications: 1. Scientific authors: 1. Name: Niklas Gerloff Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2021 Publications: 2. Doi: Not set Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland Publications: 2. Scientific authors: 1. Name: Tom Smolinka Publications: 2. Scientific authors: 1. Orcid: Not set Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe Publications: 2. Scientific authors: 2. Orcid: Not set Publications: 2. Scientific authors: 3. Name: Philip Sterchele Publications: 2. Scientific authors: 3. Orcid: Not set Publications: 2. Scientific authors: 4. Name: Andreas Palzer Publications: 2. Scientific authors: 4. Orcid: Not set Publications: 2. Scientific authors: 5. Name: Franz Lehner Publications: 2. Scientific authors: 5. Orcid: Not set Publications: 2. Scientific authors: 6. Name: Malte Jansen Publications: 2. Scientific authors: 6. Orcid: Not set Publications: 2. Scientific authors: 7. Name: Steffen Kiemel Publications: 2. Scientific authors: 7. Orcid: Not set Publications: 2. Scientific authors: 8. Name: Robert Miehe Publications: 2. Scientific authors: 8. Orcid: Not set Publications: 2. Scientific authors: 9. Name: Sylvia Wahren Publications: 2. Scientific authors: 9. Orcid: Not set Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann Publications: 2. Scientific authors: 10. Orcid: Not set Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: technical_report Publications: 2. Publication year: 2018 |
|
| Version metadata | System boundary | Foreground reference: 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. | Material/component supply, recorded forming services and assembly electricity for one PEM stack. Hydrogen-production utilities, lifetime multiplication and the paired finished-equipment treatment are modelled separately. | |
| Version metadata | Technological representativeness | 2 | 4 | |
| Version metadata | Technology description | Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. | PEM stack represented by material supply, forming/processing and component purchases. This unit represents one manufactured component, separately from the operating model's lifetime purchases. A selected PFSA EW1100 supply proxy represents the membrane. | |
| Version metadata | Technology readiness level | 8 | 9 | |
| Version metadata | Temporal representativeness | 2 | 4 | |
| Version metadata | Limitations on use | Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. | Source component quantities and estimated assembly energy do not establish a measured complete manufacturer bill of materials, actual industrial yield or equivalent supplier grades/performance. SM1 BoP energy totals follow approximately linear 1 MW scaling, despite the paragraph's 0.7 exponent; they are about 7.94 times a reconstruction using that exponent. Some component intensities may already be scaled. Original H2_generation and data_generation_material workbooks were not recovered, limiting exact reconstruction. SM1 figure image2 prints 0.075 kg Pt, while CLIC and the later compiler use 0.75 kg; the tenfold conflict remains unresolved. The matching 0.8 kg iridium entry does not resolve platinum. Membrane grade is a proxy; iridium allocation and missing trace/process information remain qualified. | |
| Version metadata | Description | Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. |
Manufacturing reference for one stack of a nominal 1 MWe PEM water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations. | Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses. The description states the resulting reference flow, process boundary and remaining source limitations. |
| Version metadata | Intended application | Not set | Provision of one PEM electrolyzer stack in compatible operating or equipment scenarios with separate lifetime and retirement accounting. | Apply reviewed discovery metadata and change explanations from the curated release. |
| Version metadata | Name | electrolyzer production, 1MWe, PEM, Stack | electrolyzer production, 1MWe, PEM, stack | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content