Overview

Process description and catalog context. View scientific metadata

Description

Manufacturing reference for one stack of a nominal 1 MWe PEM water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Hydrogen via electrolysis (energy/hydrogen/electrolysis)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0

Classification path: Energy > Hydrogen > Hydrogen via electrolysis

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Scientific journal publication

Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759

Inventory changes relative to source: Not assessed

Equivalence to the original source inventory has not been established.

Background database
ecoinvent / 3.9
Background system model
cut-off
Biosphere database
ecoinvent / 3.9

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Mature commercial
Design capacity
1
Design capacity unit
MW
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 15 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change 99858.1 kg CO2-Eq / unit
Screening result

This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.

Show all 16 indicator totals
Acidification 3074.15 mol H+-Eq / unit
Climate change 99858.1 kg CO2-Eq / unit
Freshwater ecotoxicity 466276 CTUe / unit
Freshwater eutrophication 79.1819 kg P-Eq / unit
Marine eutrophication 53.8447 kg N-Eq / unit
Terrestrial eutrophication 510.401 mol N-Eq / unit
Human toxicity, cancer 9.3624e-05 CTUh / unit
Human toxicity, non-cancer 0.00231433 CTUh / unit
Ionising radiation 25352.5 kBq U235-Eq / unit
Land use 358976 dimensionless / unit
Ozone depletion 0.0453485 kg CFC-11-Eq / unit
Particulate matter 0.00420199 disease incidence / unit
Photochemical ozone formation 335.703 kg NMVOC-Eq / unit
Resource use, fossils 1.3363e+06 MJ, net calorific value / unit
Resource use, minerals and metals 1.9083 kg Sb-Eq / unit
Water use 2.0103e+06 m3 world Eq deprived / unit
Calculation details

Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact 4e70d56a85b1 · calculated 2026-11-03 09:12 UTC. These screening results do not replace a reviewed comparative LCA.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
electrolyzer production, 1MWe, PEM, stack
RER
electrolyzer, 1MWe, PEM, Stack
1
unit Reference flow

Inputs

Technosphere inputs 14 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
market for aluminium, wrought alloy
GLO
aluminium, wrought alloy
27
kilogram
134.302 kg CO2-Eq / unit 0.1% of total
BAFU:2025
market for sheet rolling, aluminium
GLO
sheet rolling, aluminium
27
kilogram
11.8707 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for titanium
GLO
titanium
528
kilogram
2197.86 kg CO2-Eq / unit 2.2% of total
BAFU:2025
PFSA membrane, EW1100, dry acid form, engineering reference
16
kilogram
1608.75 kg CO2-Eq / unit 1.6% of total
market for carbon black
GLO
carbon black
4.5
kilogram
14.9268 kg CO2-Eq / unit 0.0% of total
BAFU:2025
iridium
0.8
kilogram
24693.7 kg CO2-Eq / unit 24.7% of total
market for platinum
GLO
platinum
0.75
kilogram
7745.38 kg CO2-Eq / unit 7.8% of total
BAFU:2025
market for carbon black
GLO
carbon black
4.5
kilogram
14.9268 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for copper, cathode
GLO
copper, cathode
4.5
kilogram
38.2931 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for sheet rolling, copper
GLO
sheet rolling, copper
4.5
kilogram
1.35966 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for sheet rolling, chromium steel
GLO
sheet rolling, chromium steel
100
kilogram
42.9588 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for steel, chromium steel 18/8, hot rolled
GLO
steel, chromium steel 18/8, hot rolled
100
kilogram
42.9588 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for synthetic rubber
GLO
synthetic rubber
4.8
kilogram
13.7582 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market group for electricity, low voltage
GLO
electricity, low voltage
1.04e+05
kilowatt hour
63297 kg CO2-Eq / unit 63.4% of total
BAFU:2025
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 2 versions · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  • Version 1.0.1 revises version 1.0.0.
  1. Version 1.0.0
    Published

    First published inventory; no earlier version is available for comparison.

    Superseded
  2. Version 1.0.1
    Published

    Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material…

    Published · Viewing · Latest
Show full version history table (2 versions)
Version Published Reason for this version Link
Version 1.0.1 2026-11-03 Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses. Current view
Version 1.0.0 Superseded Published 2026-07-15 First published inventory; no earlier version is available for comparison. Open version
About this version

Why this version changed

Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses.

Release notes

The previous monomer and generic PGM inputs are replaced without changing the 16 kg membrane or 0.8 kg iridium quantities. Product identity and production boundary are corrected; no new catalyst-performance, membrane-lifetime or operating-efficiency improvement is assumed.

Changes from version 1.0.0 Compare this version with its predecessor. Exchanges are grouped by type and change; biosphere labels include their environmental compartments. Open the base version. Show changes Hide changes

Why this version changed

Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses.

Public revision record

This comparison is permanently visible with the published version so users can assess every detected change before reuse.

Modified exchanges
1
Added exchanges
2
Removed exchanges
2
Inventory metadata
0
Version metadata
15
Technosphere exchanges added 2
Technosphere exchanges added
Exchange / scope Field Previous value Revised value Reason
perfluorosulfonic acid membrane production, ew1100, engineering reference (technosphere / GLO / kilogram) Amount Not present 16 kilogram Represent the stack’s 16 kg ion-exchange membrane as finished PFSA membrane rather than tetrafluoroethylene monomer. The shared dry, unreinforced EW1100 reference includes polymer/membrane manufacture while retaining the membrane quantity. It is an engineering grade proxy, not proof that every PEM stack uses an identical commercial membrane.
iridium production, economic allocation, proxy (technosphere / ZA / kilogram) Amount Not present 0.8 kilogram The iridium entry supplies the material, process or treatment required by the revised reference. Membrane-polymer manufacture belongs upstream of the cell or stack using the membrane, while assembly remains at the parent system. The membrane boundary now supplies finished perfluorosulfonic material rather than treating a fluorinated monomer as the finished membrane.
Technosphere exchanges removed 2
Technosphere exchanges removed
Exchange / scope Field Previous value Revised value Reason
market for tetrafluoroethylene (technosphere / GLO / kilogram) Amount 16 kilogram Not present Represent the stack’s 16 kg ion-exchange membrane as finished PFSA membrane rather than tetrafluoroethylene monomer. The shared dry, unreinforced EW1100 reference includes polymer/membrane manufacture while retaining the membrane quantity. It is an engineering grade proxy, not proof that every PEM stack uses an identical commercial membrane.
platinum group metal, extraction and refinery operations (technosphere / ZA / kilogram) Amount 0.8 kilogram Not present The former iridium entry is superseded by the revised product/component boundary. Membrane-polymer manufacture belongs upstream of the cell or stack using the membrane, while assembly remains at the parent system. The membrane boundary now supplies finished perfluorosulfonic material rather than treating a fluorinated monomer as the finished membrane.
Reference flows modified 1
Reference flows modified
Exchange / scope Field Previous value Revised value Reason
electrolyzer production, 1MWe, PEM, stack (production / RER / unit) Name electrolyzer production, 1MWe, PEM, Stack electrolyzer production, 1MWe, PEM, stack Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable.
Metadata changes 15
Metadata changes
Exchange / scope Field Previous value Revised value Reason
Version metadata Commercial maturity stage early_commercial mature_commercial No explanation was recorded for this change.
Version metadata Inventory evidence types Literature; Engineering estimate Literature; Engineering estimate; Proxy
Version metadata Geographical representativeness 2 3
Version metadata Methodology and allocation explanation The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Source model
Gerloff (2021) compares 1 MWe AEC, PEM and SOEC systems under German 2019, 2030, 2050 and renewable-electricity scenarios. The study uses ecoinvent 3.5 cutoff, European/German suppliers, Umberto+, ILCD 2.0 midpoint 2018 and IPCC 2013 GWP. CLIC uses separately declared 3.9 background/biosphere profiles and later material, lifetime and utility adaptations. Publication and scenario years do not date measured inputs.

Manufacturing basis
The reference is one manufactured stack, including 103890.7681 kWh assembly electricity. Processing services are separate from installed material mass. Stack assembly electricity is the source's three-stack total divided by three.

Lifetime accounting
The paper assumes 20 years at 8000 h/year and numerically counts three stacks, despite wording about three replacements. SM1 manufacturing-energy totals also include three stacks; the CLIC stack-manufacturing reference uses one third. Operating models separately purchase four PEM/AEC stacks or eight SOEC stacks with corresponding signed retirement. The retrieved IndWEDe document is the Kurzfassung, whereas the cited p. 178 belongs to an unrecovered full report. Selected lifetimes are not independently verified from that page.

Materials
The recipe includes 16 kg PFSA, 0.8 kg iridium and 0.75 kg platinum per stack. Iridium uses a separately modelled economic-allocation production proxy.
Version metadata Plant lifetime 20 Not set
Version metadata Contributors, publications, projects and supporting evidence Evidence: 1. Origin: source_import
Evidence: 1. Target field: data_origins
Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: source_import
Evidence: 2. Target field: data_origins
Evidence: 2. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 2. Source location: source
Evidence: 2. Source reference: Existing published CLIC inventory documentation
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: description
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: included_life_cycle_stages
Evidence: 4. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Evidence: 4. Source location: name
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: publications
Evidence: 5. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 5. Source location: source
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 6. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 6. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: publications
Evidence: 7. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
Evidence: 7. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers
Evidence: 7. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: methodology_notes
Evidence: 8. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Evidence: 8. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Evidence: 8. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Publications: 1. Doi: 10.1016/j.est.2021.102759
Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Publications: 1. Scientific authors: 1. Name: Niklas Gerloff
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany
Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2021
Publications: 2. Doi: Not set
Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Publications: 2. Scientific authors: 1. Name: Tom Smolinka
Publications: 2. Scientific authors: 1. Orcid: Not set
Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 3. Name: Philip Sterchele
Publications: 2. Scientific authors: 3. Orcid: Not set
Publications: 2. Scientific authors: 4. Name: Andreas Palzer
Publications: 2. Scientific authors: 4. Orcid: Not set
Publications: 2. Scientific authors: 5. Name: Franz Lehner
Publications: 2. Scientific authors: 5. Orcid: Not set
Publications: 2. Scientific authors: 6. Name: Malte Jansen
Publications: 2. Scientific authors: 6. Orcid: Not set
Publications: 2. Scientific authors: 7. Name: Steffen Kiemel
Publications: 2. Scientific authors: 7. Orcid: Not set
Publications: 2. Scientific authors: 8. Name: Robert Miehe
Publications: 2. Scientific authors: 8. Orcid: Not set
Publications: 2. Scientific authors: 9. Name: Sylvia Wahren
Publications: 2. Scientific authors: 9. Orcid: Not set
Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann
Publications: 2. Scientific authors: 10. Orcid: Not set
Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Evidence: 1. Origin: source_import
Evidence: 1. Target field: data_origins
Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: source_import
Evidence: 2. Target field: data_origins
Evidence: 2. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 2. Source location: description
Evidence: 2. Source reference: Existing published CLIC inventory documentation
Evidence: 3. Origin: source_import
Evidence: 3. Target field: data_origins
Evidence: 3. Qualification: Documented inputs to this compilation/model, not newly measured data. Omitted tags remain unspecified. Literature denotes cited inventory sources.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: source_import
Evidence: 4. Target field: included_life_cycle_stages
Evidence: 4. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Evidence: 4. Source location: name
Evidence: 4. Source reference: Existing published CLIC inventory documentation
Evidence: 5. Origin: source_import
Evidence: 5. Target field: use_limitations
Evidence: 5. Qualification: Copied version-specific scientific qualification; it remains applicable to this exact reconstruction and is not a claim about the source paper.
Evidence: 5. Source location: description
Evidence: 5. Source reference: Existing published CLIC inventory documentation
Evidence: 6. Origin: source_import
Evidence: 6. Target field: publications
Evidence: 6. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 6. Source location: source
Evidence: 6. Source reference: Existing published CLIC inventory documentation
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: publications
Evidence: 7. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 7. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 7. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: publications
Evidence: 8. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
Evidence: 8. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers
Evidence: 8. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 9. Origin: editor_verification
Evidence: 9. Target field: methodology_notes
Evidence: 9. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Evidence: 9. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Evidence: 9. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 10. Origin: editor_verification
Evidence: 10. Target field: technology_description
Evidence: 10. Qualification: Technical-characterisation review TC-2057. Design capacity: 1.000000. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 10. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 10. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 11. Origin: editor_verification
Evidence: 11. Target field: technology_description
Evidence: 11. Qualification: Technical-characterisation review TC-2057. Design capacity unit: MW. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 11. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 11. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 12. Origin: editor_verification
Evidence: 12. Target field: technology_description
Evidence: 12. Qualification: Technical-characterisation review TC-2057. Capacity factor (%): Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 12. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 12. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 13. Origin: editor_verification
Evidence: 13. Target field: technology_description
Evidence: 13. Qualification: Technical-characterisation review TC-2057. Annual production volume: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 13. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 13. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 14. Origin: editor_verification
Evidence: 14. Target field: technology_description
Evidence: 14. Qualification: Technical-characterisation review TC-2057. Annual production volume unit: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 14. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 14. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 15. Origin: editor_verification
Evidence: 15. Target field: technology_description
Evidence: 15. Qualification: Technical-characterisation review TC-2057. Annual production volume year: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 15. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 15. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 16. Origin: editor_verification
Evidence: 16. Target field: technology_description
Evidence: 16. Qualification: Technical-characterisation review TC-2057. Plant or represented-asset lifetime (years): Unspecified. Basis: PEM stack is replaced within the 20 years ystem model. The selected compiler stack life is5.5 year s, not20 year s. The integer field cannot store5.5losslessly; clear the wrong system-life scalar and retain explicit fractional stack context. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 16. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 16. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 17. Origin: editor_verification
Evidence: 17. Target field: technology_description
Evidence: 17. Qualification: Technical-characterisation review TC-2057. Commercial maturity stage: mature_commercial. Basis: Curator assessment of established alkaline/PEM manufacturing and hydrogen-production routes, corroborated by primary energy-agency context. Numeric9is not assigned by Gerloffto each exact CLIC object and does not validate the model material, pressure, water or lifetime assumptions. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 17. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 17. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 18. Origin: editor_verification
Evidence: 18. Target field: technology_description
Evidence: 18. Qualification: Technical-characterisation review TC-2057. Technology readiness level: 9. Basis: Curator assessment of established alkaline/PEM manufacturing and hydrogen-production routes, corroborated by primary energy-agency context. Numeric9is not assigned by Gerloffto each exact CLIC object and does not validate the model material, pressure, water or lifetime assumptions. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 18. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 18. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 19. Origin: editor_verification
Evidence: 19. Target field: technology_description
Evidence: 19. Qualification: Technical-characterisation review TC-2057. Technological representativeness: 4. Basis: Curator assessment of a hybrid literature/compiler model with selected updated membrane/alloy/PCS/drive and utility assumptions. Established route maturity does not make exact bill and performance representative measured production. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 19. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 19. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 20. Origin: editor_verification
Evidence: 20. Target field: technology_description
Evidence: 20. Qualification: Technical-characterisation review TC-2057. Geographical representativeness: 3. Basis: Curator assessment of generic regional supplier/material references and scenario electricity choices, not a matched or production-weighted factory population. Selected supply scenarios do not independently establish equipment manufacturing geography. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 20. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 20. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 21. Origin: editor_verification
Evidence: 21. Target field: technology_description
Evidence: 21. Qualification: Technical-characterisation review TC-2057. Temporal representativeness: 4. Basis: Curator assessment of mixed historical source materials, IndWEDe/manufacturer scenario assumptions and later compiler adaptations.2019/2030/2050electricity scenarios,2021publication and current equipment availability are not full-inventory observation periods. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 21. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 21. Source reference: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Doi: 10.1016/j.est.2021.102759
Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Publications: 1. Scientific authors: 1. Name: Niklas Gerloff
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany
Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2021
Publications: 2. Doi: Not set
Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Publications: 2. Scientific authors: 1. Name: Tom Smolinka
Publications: 2. Scientific authors: 1. Orcid: Not set
Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 3. Name: Philip Sterchele
Publications: 2. Scientific authors: 3. Orcid: Not set
Publications: 2. Scientific authors: 4. Name: Andreas Palzer
Publications: 2. Scientific authors: 4. Orcid: Not set
Publications: 2. Scientific authors: 5. Name: Franz Lehner
Publications: 2. Scientific authors: 5. Orcid: Not set
Publications: 2. Scientific authors: 6. Name: Malte Jansen
Publications: 2. Scientific authors: 6. Orcid: Not set
Publications: 2. Scientific authors: 7. Name: Steffen Kiemel
Publications: 2. Scientific authors: 7. Orcid: Not set
Publications: 2. Scientific authors: 8. Name: Robert Miehe
Publications: 2. Scientific authors: 8. Orcid: Not set
Publications: 2. Scientific authors: 9. Name: Sylvia Wahren
Publications: 2. Scientific authors: 9. Orcid: Not set
Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann
Publications: 2. Scientific authors: 10. Orcid: Not set
Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Version metadata System boundary Foreground reference: 1 unit of electrolyzer, 1MWe, PEM, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Material/component supply, recorded forming services and assembly electricity for one PEM stack. Hydrogen-production utilities, lifetime multiplication and the paired finished-equipment treatment are modelled separately.
Version metadata Technological representativeness 2 4
Version metadata Technology description Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack. PEM stack represented by material supply, forming/processing and component purchases. This unit represents one manufactured component, separately from the operating model's lifetime purchases. A selected PFSA EW1100 supply proxy represents the membrane.
Version metadata Technology readiness level 8 9
Version metadata Temporal representativeness 2 4
Version metadata Limitations on use Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Source component quantities and estimated assembly energy do not establish a measured complete manufacturer bill of materials, actual industrial yield or equivalent supplier grades/performance. SM1 BoP energy totals follow approximately linear 1 MW scaling, despite the paragraph's 0.7 exponent; they are about 7.94 times a reconstruction using that exponent. Some component intensities may already be scaled. Original H2_generation and data_generation_material workbooks were not recovered, limiting exact reconstruction. SM1 figure image2 prints 0.075 kg Pt, while CLIC and the later compiler use 0.75 kg; the tenfold conflict remains unresolved. The matching 0.8 kg iridium entry does not resolve platinum. Membrane grade is a proxy; iridium allocation and missing trace/process information remain qualified.
Version metadata Description Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, PEM, Stack.

The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.

Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SM1 PEM figure image2.emf prints0.075kgPt, whereas CLIC2057/4856and pinned later compiler use0.75kg. Iridium0.8kg matches. Resolve tenfold Pt source conflict; no arbitrary decimal correction or numeric revision proposed. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Manufacturing reference for one stack of a nominal 1 MWe PEM water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations. Represent the PEM stack membrane as a finished PFSA membrane and the catalyst metal as an iridium-specific, economically allocated production reference, keeping their material doses. The description states the resulting reference flow, process boundary and remaining source limitations.
Version metadata Intended application Not set Provision of one PEM electrolyzer stack in compatible operating or equipment scenarios with separate lifetime and retirement accounting. Apply reviewed discovery metadata and change explanations from the curated release.
Version metadata Name electrolyzer production, 1MWe, PEM, Stack electrolyzer production, 1MWe, PEM, stack Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable.
Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content