Description
Manufacturing reference for one stack of a nominal 1 MWe SOEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.
Hydrogen via electrolysis
Reference product electrolyzer, 1MWe, SOEC, Stack RER
Stable dataset identity
electrolyzer-production-1mwe-soec-stack
1.0.1Published inventory
Process description and catalog context. View scientific metadata
Manufacturing reference for one stack of a nominal 1 MWe SOEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.
Classification, keywords, bookmarks and download counts.
Classification path: Energy > Hydrogen > Hydrogen via electrolysis
Log in to bookmarkSource documentation, background profiles and references.
Scientific journal publication
Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Inventory changes relative to source: Not assessed
Equivalence to the original source inventory has not been established.
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-03 09:13 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
electrolyzer production, 1MWe, SOEC, stack
RER
|
electrolyzer, 1MWe, SOEC, Stack
|
1
|
unit | - | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
market for sheet rolling, chromium steel
GLO
|
sheet rolling, chromium steel
|
8976.1
|
kilogram |
19.4571
mol H+-Eq / unit
3.0% of total
3856.03
kg CO2-Eq / unit
2.7% of total
70212.2
CTUe / unit
13.0% of total
1.92012
kg P-Eq / unit
3.5% of total
3.58421
kg N-Eq / unit
4.4% of total
38.0895
mol N-Eq / unit
4.7% of total
3.5088e-05
CTUh / unit
7.3% of total
0.000116249
CTUh / unit
6.0% of total
2067.07
kBq U235-Eq / unit
4.3% of total
21017.9
dimensionless / unit
4.0% of total
7.5189e-05
kg CFC-11-Eq / unit
3.4% of total
0.00021656
disease incidence / unit
4.7% of total
13.9434
kg NMVOC-Eq / unit
4.6% of total
61730.9
MJ, net calorific value / unit
3.0% of total
0.0600364
kg Sb-Eq / unit
3.8% of total
1205.49
m3 world Eq deprived / unit
0.1% of total
BAFU:2025
|
|
|
market for praseodymium oxide
GLO
|
praseodymium oxide
|
9
|
kilogram |
1.08835
mol H+-Eq / unit
0.2% of total
369.558
kg CO2-Eq / unit
0.3% of total
2378.65
CTUe / unit
0.4% of total
0.112295
kg P-Eq / unit
0.2% of total
0.178079
kg N-Eq / unit
0.2% of total
1.80992
mol N-Eq / unit
0.2% of total
2.5556e-07
CTUh / unit
0.1% of total
4.9747e-06
CTUh / unit
0.3% of total
47.1069
kBq U235-Eq / unit
0.1% of total
842.835
dimensionless / unit
0.2% of total
2.8401e-05
kg CFC-11-Eq / unit
1.3% of total
9.1137e-06
disease incidence / unit
0.2% of total
1.01002
kg NMVOC-Eq / unit
0.3% of total
6473.44
MJ, net calorific value / unit
0.3% of total
0.00272647
kg Sb-Eq / unit
0.2% of total
100.166
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for nickel, class 1
GLO
|
nickel, class 1
|
7.5
|
kilogram |
13.9762
mol H+-Eq / unit
2.1% of total
73.6845
kg CO2-Eq / unit
0.1% of total
582.077
CTUe / unit
0.1% of total
0.289018
kg P-Eq / unit
0.5% of total
0.178885
kg N-Eq / unit
0.2% of total
2.47098
mol N-Eq / unit
0.3% of total
9.2010e-08
CTUh / unit
0.0% of total
3.4154e-06
CTUh / unit
0.2% of total
18.5094
kBq U235-Eq / unit
0.0% of total
455.93
dimensionless / unit
0.1% of total
1.4283e-06
kg CFC-11-Eq / unit
0.1% of total
1.5478e-05
disease incidence / unit
0.3% of total
1.37203
kg NMVOC-Eq / unit
0.4% of total
881.728
MJ, net calorific value / unit
0.0% of total
0.000758189
kg Sb-Eq / unit
0.0% of total
37.1757
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for zirconium oxide
GLO
|
zirconium oxide
|
160.02
|
kilogram |
2.00024
mol H+-Eq / unit
0.3% of total
478.227
kg CO2-Eq / unit
0.3% of total
1938.24
CTUe / unit
0.4% of total
0.248131
kg P-Eq / unit
0.5% of total
0.40972
kg N-Eq / unit
0.5% of total
3.91833
mol N-Eq / unit
0.5% of total
4.7952e-07
CTUh / unit
0.1% of total
2.1292e-05
CTUh / unit
1.1% of total
261.469
kBq U235-Eq / unit
0.5% of total
4345.92
dimensionless / unit
0.8% of total
1.1818e-05
kg CFC-11-Eq / unit
0.5% of total
1.7453e-05
disease incidence / unit
0.4% of total
1.38029
kg NMVOC-Eq / unit
0.5% of total
7723.49
MJ, net calorific value / unit
0.4% of total
0.00639395
kg Sb-Eq / unit
0.4% of total
191.888
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for yttrium oxide
GLO
|
yttrium oxide
|
25.5
|
kilogram |
0.285228
mol H+-Eq / unit
0.0% of total
106.846
kg CO2-Eq / unit
0.1% of total
779.402
CTUe / unit
0.1% of total
0.0409621
kg P-Eq / unit
0.1% of total
0.0870745
kg N-Eq / unit
0.1% of total
0.7545
mol N-Eq / unit
0.1% of total
5.8291e-08
CTUh / unit
0.0% of total
9.9188e-07
CTUh / unit
0.1% of total
39.7425
kBq U235-Eq / unit
0.1% of total
508.072
dimensionless / unit
0.1% of total
2.9220e-06
kg CFC-11-Eq / unit
0.1% of total
2.1167e-06
disease incidence / unit
0.0% of total
0.214153
kg NMVOC-Eq / unit
0.1% of total
1540.64
MJ, net calorific value / unit
0.1% of total
0.000603256
kg Sb-Eq / unit
0.0% of total
3762.89
m3 world Eq deprived / unit
0.2% of total
BAFU:2025
|
|
|
market for cerium oxide
GLO
|
cerium oxide
|
98.25
|
kilogram |
2.49249
mol H+-Eq / unit
0.4% of total
784.792
kg CO2-Eq / unit
0.5% of total
5291.27
CTUe / unit
1.0% of total
0.235742
kg P-Eq / unit
0.4% of total
0.450094
kg N-Eq / unit
0.6% of total
4.56447
mol N-Eq / unit
0.6% of total
1.2308e-06
CTUh / unit
0.3% of total
1.2566e-05
CTUh / unit
0.7% of total
125.394
kBq U235-Eq / unit
0.3% of total
2602.63
dimensionless / unit
0.5% of total
0.000116872
kg CFC-11-Eq / unit
5.2% of total
2.2068e-05
disease incidence / unit
0.5% of total
2.17992
kg NMVOC-Eq / unit
0.7% of total
13433.8
MJ, net calorific value / unit
0.7% of total
0.00662603
kg Sb-Eq / unit
0.4% of total
226.634
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market for yttrium oxide
GLO
|
yttrium oxide
|
16.11
|
kilogram |
0.180239
mol H+-Eq / unit
0.0% of total
67.5173
kg CO2-Eq / unit
0.0% of total
492.513
CTUe / unit
0.1% of total
0.0258844
kg P-Eq / unit
0.0% of total
0.0550233
kg N-Eq / unit
0.1% of total
0.476776
mol N-Eq / unit
0.1% of total
3.6835e-08
CTUh / unit
0.0% of total
6.2678e-07
CTUh / unit
0.0% of total
25.1137
kBq U235-Eq / unit
0.1% of total
321.056
dimensionless / unit
0.1% of total
1.8464e-06
kg CFC-11-Eq / unit
0.1% of total
1.3375e-06
disease incidence / unit
0.0% of total
0.135325
kg NMVOC-Eq / unit
0.0% of total
973.545
MJ, net calorific value / unit
0.0% of total
0.000381203
kg Sb-Eq / unit
0.0% of total
2377.81
m3 world Eq deprived / unit
0.1% of total
BAFU:2025
|
|
|
market for nickel, class 1
GLO
|
nickel, class 1
|
136.6
|
kilogram |
254.554
mol H+-Eq / unit
38.9% of total
1342.04
kg CO2-Eq / unit
0.9% of total
10601.6
CTUe / unit
2.0% of total
5.26399
kg P-Eq / unit
9.7% of total
3.25809
kg N-Eq / unit
4.0% of total
45.0048
mol N-Eq / unit
5.5% of total
1.6758e-06
CTUh / unit
0.3% of total
6.2206e-05
CTUh / unit
3.2% of total
337.118
kBq U235-Eq / unit
0.7% of total
8304.01
dimensionless / unit
1.6% of total
2.6014e-05
kg CFC-11-Eq / unit
1.2% of total
0.000281905
disease incidence / unit
6.2% of total
24.9892
kg NMVOC-Eq / unit
8.2% of total
16059.2
MJ, net calorific value / unit
0.8% of total
0.0138091
kg Sb-Eq / unit
0.9% of total
677.094
m3 world Eq deprived / unit
0.0% of total
BAFU:2025
|
|
|
market group for electricity, low voltage
GLO
|
electricity, low voltage
|
1.22e+05
|
kilowatt hour |
184.494
mol H+-Eq / unit
28.2% of total
74467
kg CO2-Eq / unit
51.7% of total
230008
CTUe / unit
42.6% of total
27.2112
kg P-Eq / unit
50.0% of total
35.5216
kg N-Eq / unit
43.5% of total
345.139
mol N-Eq / unit
42.2% of total
4.3428e-05
CTUh / unit
9.0% of total
0.00100131
CTUh / unit
52.0% of total
20141.3
kBq U235-Eq / unit
42.3% of total
297252
dimensionless / unit
57.1% of total
0.000763648
kg CFC-11-Eq / unit
34.1% of total
0.0016557
disease incidence / unit
36.1% of total
113.379
kg NMVOC-Eq / unit
37.1% of total
1.0427e+06
MJ, net calorific value / unit
51.2% of total
0.131554
kg Sb-Eq / unit
8.3% of total
2.1848e+06
m3 world Eq deprived / unit
93.1% of total
BAFU:2025
|
|
|
glass seal, SOEC, barium alumino-borosilicate
|
25.6
|
kilogram |
0.488642
mol H+-Eq / unit
0.1% of total
60.7944
kg CO2-Eq / unit
0.0% of total
218.836
CTUe / unit
0.0% of total
0.0183278
kg P-Eq / unit
0.0% of total
0.0466642
kg N-Eq / unit
0.1% of total
0.489343
mol N-Eq / unit
0.1% of total
3.9344e-08
CTUh / unit
0.0% of total
6.3420e-07
CTUh / unit
0.0% of total
16.7174
kBq U235-Eq / unit
0.0% of total
279.87
dimensionless / unit
0.1% of total
1.6844e-06
kg CFC-11-Eq / unit
0.1% of total
1.0826e-05
disease incidence / unit
0.2% of total
0.210103
kg NMVOC-Eq / unit
0.1% of total
1111.83
MJ, net calorific value / unit
0.1% of total
0.0613402
kg Sb-Eq / unit
3.9% of total
453.902
m3 world Eq deprived / unit
0.0% of total
|
||
|
contact ceramic, lanthanum strontium manganite, La0.8Sr0.2MnO3
|
2.1
|
kilogram |
0.0545681
mol H+-Eq / unit
0.0% of total
18.0016
kg CO2-Eq / unit
0.0% of total
135.554
CTUe / unit
0.0% of total
0.00578388
kg P-Eq / unit
0.0% of total
0.0122852
kg N-Eq / unit
0.0% of total
0.114389
mol N-Eq / unit
0.0% of total
1.9790e-08
CTUh / unit
0.0% of total
2.5181e-07
CTUh / unit
0.0% of total
3.56889
kBq U235-Eq / unit
0.0% of total
62.7714
dimensionless / unit
0.0% of total
1.7396e-06
kg CFC-11-Eq / unit
0.1% of total
4.6477e-07
disease incidence / unit
0.0% of total
0.0443907
kg NMVOC-Eq / unit
0.0% of total
288.612
MJ, net calorific value / unit
0.0% of total
0.000129264
kg Sb-Eq / unit
0.0% of total
162.04
m3 world Eq deprived / unit
0.0% of total
|
||
|
ferritic steel, electrolysis interconnect, Crofer 22 APU type
|
8976.1
|
kilogram | - |
174.732
mol H+-Eq / unit
26.7% of total
62482.1
kg CO2-Eq / unit
43.4% of total
217030
CTUe / unit
40.2% of total
19.071
kg P-Eq / unit
35.0% of total
37.9453
kg N-Eq / unit
46.4% of total
375.943
mol N-Eq / unit
45.9% of total
0.000397671
CTUh / unit
82.8% of total
0.000699526
CTUh / unit
36.4% of total
24489.9
kBq U235-Eq / unit
51.5% of total
184197
dimensionless / unit
35.4% of total
0.00120578
kg CFC-11-Eq / unit
53.9% of total
0.00235025
disease incidence / unit
51.3% of total
146.602
kg NMVOC-Eq / unit
48.0% of total
882096
MJ, net calorific value / unit
43.3% of total
1.29337
kg Sb-Eq / unit
82.0% of total
152308
m3 world Eq deprived / unit
6.5% of total
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
6 CLIC nodes and 7 background boundary nodes shown. Direct inputs appear to the left of the current dataset, while emissions and direct consumers appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
First published inventory; no earlier version is available for comparison.
SupersededUse material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-11-03 | Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries. | Current view |
| Version 1.0.0 Superseded | Published 2026-07-15 | First published inventory; no earlier version is available for comparison. | Open version |
Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries.
The ferritic alloy replaces the 18/8 steel placeholder at unchanged plate mass. Matched yttrium-containing oxide purchases replace mixed Sm/Eu/Gd oxide impact proxies. Finished LSM and glass references own their precursor and manufacturing inputs, replacing the old separate placeholders; their source-specific loading and process limitations remain explicit.
Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for zirconium oxide (technosphere / GLO / kilogram) | Amount | 170.7 | 160.01991086063632 | The quantity of zirconium oxide follows the selected material or process reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for cerium oxide (technosphere / GLO / kilogram) | Amount | 91.5 | 98.25386326929127 | The quantity of cerium oxide follows the selected material or process reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for yttrium oxide (technosphere / GLO / kilogram) | Amount | Not present | 25.49931784143422 kilogram | The yttrium oxide entry supplies the material, process or treatment required by the revised reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for yttrium oxide (technosphere / GLO / kilogram) | Amount | Not present | 16.113284777632217 kilogram | |
| glass seal production, SOEC, barium alumino-borosilicate (technosphere / GLO / kilogram) | Amount | Not present | 25.6 kilogram | The glass seal, SOEC, barium alumino-borosilicate entry supplies the material, process or treatment required by the revised reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| contact ceramic production, lanthanum strontium manganite, la0.8sr0.2mno3 (technosphere / GLO / kilogram) | Amount | Not present | 2.1 kilogram | The contact ceramic, lanthanum strontium manganite, La0.8Sr0.2MnO3 entry supplies the material, process or treatment required by the revised reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| ferritic steel production, electrolysis interconnect, crofer 22 apu type (technosphere / GLO / kilogram) | Amount | Not present | 8976.1 kilogram | Use the ferritic Crofer22APU-type interconnect material reference for the high-temperature SOEC function instead of generic austenitic 18/8 chromium steel. The 8976.1 kg plate mass and separate rolling service are retained. Alloy composition and manufacturing remain qualified engineering assumptions rather than a verified full-scale stack bill of materials. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for steel, chromium steel 18/8, hot rolled (technosphere / GLO / kilogram) | Amount | 8976.1 kilogram | Not present | Use the ferritic Crofer22APU-type interconnect material reference for the high-temperature SOEC function instead of generic austenitic 18/8 chromium steel. The 8976.1 kg plate mass and separate rolling service are retained. Alloy composition and manufacturing remain qualified engineering assumptions rather than a verified full-scale stack bill of materials. |
| market for samarium-europium-gadolinium oxide (technosphere / GLO / kilogram) | Amount | 14.8 kilogram | Not present | The former samarium-europium-gadolinium oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for samarium-europium-gadolinium oxide (technosphere / GLO / kilogram) | Amount | 22.9 kilogram | Not present | |
| market for lanthanum oxide (technosphere / GLO / kilogram) | Amount | 21 kilogram | Not present | The former lanthanum oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for strontium carbonate (technosphere / GLO / kilogram) | Amount | 21 kilogram | Not present | Purchase the finished La0.8Sr0.2MnO3 contact ceramic at the author-model 2.1 kg stack loading instead of the two separate 21 kg lanthanum-oxide/strontium-carbonate placeholders. Precursor chemistry and calcination are included inside the ceramic reference. The new loading is a selected author-model basis, not a claim that the old 21 kg entries were decimal errors. |
| market for aluminium oxide, metallurgical (technosphere / IAI Area, EU27 & EFTA / kilogram) | Amount | 6.4 kilogram | Not present | The former aluminium oxide, metallurgical entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for boric oxide (technosphere / GLO / kilogram) | Amount | 6.4 kilogram | Not present | The former boric oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for barium oxide (technosphere / GLO / kilogram) | Amount | 6.4 kilogram | Not present | The former barium oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component. |
| market for silicone product (technosphere / RER / kilogram) | Amount | 6.4 kilogram | Not present | Replace the silicone-polymer proxy and the other three 6.4 kg placeholder materials with a finished barium alumino-borosilicate glass-seal reference. Its 25.6 kg loading retains their combined nominal mass and includes the selected glass composition and manufacture. Loading, composition transfer, utilities and manufacturing losses remain engineering assumptions. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| electrolyzer production, 1MWe, SOEC, stack (production / RER / unit) | Name | electrolyzer production, 1MWe, SOEC, Stack | electrolyzer production, 1MWe, SOEC, stack | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Version metadata | Inventory evidence types | Literature | Literature; Engineering estimate | No explanation was recorded for this change. |
| Version metadata | Geographical representativeness | 2 | 3 | |
| Version metadata | Methodology and allocation explanation | The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. | Source model Gerloff (2021) compares 1 MWe AEC, PEM and SOEC systems under German 2019, 2030, 2050 and renewable-electricity scenarios. The study uses ecoinvent 3.5 cutoff, European/German suppliers, Umberto+, ILCD 2.0 midpoint 2018 and IPCC 2013 GWP. CLIC uses separately declared 3.9 background/biosphere profiles and later material, lifetime and utility adaptations. Publication and scenario years do not date measured inputs. Manufacturing basis The reference is one manufactured stack, including 122224.433 kWh assembly electricity. Processing services are separate from installed material mass. Stack assembly electricity is the source's three-stack total divided by three. Lifetime accounting The paper assumes 20 years at 8000 h/year and numerically counts three stacks, despite wording about three replacements. SM1 manufacturing-energy totals also include three stacks; the CLIC stack-manufacturing reference uses one third. Operating models separately purchase four PEM/AEC stacks or eight SOEC stacks with corresponding signed retirement. The retrieved IndWEDe document is the Kurzfassung, whereas the cited p. 178 belongs to an unrecovered full report. Selected lifetimes are not independently verified from that page. Materials The 8976.1 kg interconnect purchase retains its matching steel-rolling service; an older air-electrode label does not establish that function. YSZ uses 8 mol% Y2O3-stabilized zirconia and YDC uses Ce0.8Y0.2O1.9, reconstructed from 0.425 and 0.262 kg/kW source references with the 0.88 scale exponent. Ceramic incorporation assumes 100% retention with unquantified purchase-boundary loss. Glass-seal loading is a combined 25.6 kg placeholder rather than measured seal geometry. Finished LSM loading is 2.1 kg/MW from an author-model reference. |
|
| Version metadata | Contributors, publications, projects and supporting evidence | Evidence: 1. Origin: source_import Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: included_life_cycle_stages Evidence: 2. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage. Evidence: 2. Source location: name Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: source_import Evidence: 3. Target field: publications Evidence: 3. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship. Evidence: 4. Source location: Publisher-deposited registry /message/title, /message/published and /message/author Evidence: 4. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759 Evidence: 5. Origin: editor_verification Evidence: 5. Target field: publications Evidence: 5. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles. Evidence: 5. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers Evidence: 5. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Evidence: 6. Origin: editor_verification Evidence: 6. Target field: methodology_notes Evidence: 6. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Evidence: 6. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci Evidence: 6. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Publications: 1. Doi: 10.1016/j.est.2021.102759 Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production Publications: 1. Scientific authors: 1. Name: Niklas Gerloff Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2021 Publications: 2. Doi: Not set Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland Publications: 2. Scientific authors: 1. Name: Tom Smolinka Publications: 2. Scientific authors: 1. Orcid: Not set Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe Publications: 2. Scientific authors: 2. Orcid: Not set Publications: 2. Scientific authors: 3. Name: Philip Sterchele Publications: 2. Scientific authors: 3. Orcid: Not set Publications: 2. Scientific authors: 4. Name: Andreas Palzer Publications: 2. Scientific authors: 4. Orcid: Not set Publications: 2. Scientific authors: 5. Name: Franz Lehner Publications: 2. Scientific authors: 5. Orcid: Not set Publications: 2. Scientific authors: 6. Name: Malte Jansen Publications: 2. Scientific authors: 6. Orcid: Not set Publications: 2. Scientific authors: 7. Name: Steffen Kiemel Publications: 2. Scientific authors: 7. Orcid: Not set Publications: 2. Scientific authors: 8. Name: Robert Miehe Publications: 2. Scientific authors: 8. Orcid: Not set Publications: 2. Scientific authors: 9. Name: Sylvia Wahren Publications: 2. Scientific authors: 9. Orcid: Not set Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann Publications: 2. Scientific authors: 10. Orcid: Not set Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: technical_report Publications: 2. Publication year: 2018 |
Evidence: 1. Origin: source_import Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: source_import Evidence: 2. Target field: included_life_cycle_stages Evidence: 2. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage. Evidence: 2. Source location: name Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: source_import Evidence: 3. Target field: use_limitations Evidence: 3. Qualification: Copied version-specific scientific qualification; it remains applicable to this exact reconstruction and is not a claim about the source paper. Evidence: 3. Source location: description Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers. Evidence: 4. Source location: DOI registration: title, publication dates and byline Evidence: 4. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759 Evidence: 5. Origin: editor_verification Evidence: 5. Target field: publications Evidence: 5. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles. Evidence: 5. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers Evidence: 5. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Evidence: 6. Origin: editor_verification Evidence: 6. Target field: methodology_notes Evidence: 6. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Evidence: 6. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci Evidence: 6. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx Evidence: 7. Origin: editor_verification Evidence: 7. Target field: technology_description Evidence: 7. Qualification: Technical-characterisation review TC-2068. Design capacity: 1.000000. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 7. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 7. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 8. Origin: editor_verification Evidence: 8. Target field: technology_description Evidence: 8. Qualification: Technical-characterisation review TC-2068. Design capacity unit: MW. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 8. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 8. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 9. Origin: editor_verification Evidence: 9. Target field: technology_description Evidence: 9. Qualification: Technical-characterisation review TC-2068. Capacity factor (%): Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 9. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 9. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 10. Origin: editor_verification Evidence: 10. Target field: technology_description Evidence: 10. Qualification: Technical-characterisation review TC-2068. Annual production volume: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 10. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 10. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: technology_description Evidence: 11. Qualification: Technical-characterisation review TC-2068. Annual production volume unit: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 11. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 11. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 12. Origin: editor_verification Evidence: 12. Target field: technology_description Evidence: 12. Qualification: Technical-characterisation review TC-2068. Annual production volume year: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 12. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 12. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: technology_description Evidence: 13. Qualification: Technical-characterisation review TC-2068. Plant or represented-asset lifetime (years): Unspecified. Basis: Single-component manufacture and whole-system operating life are different scopes. Existing source/current lifetime wording must be reconciled before transferring a consumer system or stack lifetime to this record. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 13. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json Evidence: 13. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-2068. Commercial maturity stage: early_commercial. Basis: Retain early-commercial/TRL8as a qualified curator route estimate for SOEC, supported by contemporary industrial demonstration context. This is not a manufacturer/source-assigned numeric TRL for the exact1 MW model or validation of steam/pressure interfaces and durability. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 14. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-2068. Technology readiness level: 8. Basis: Retain early-commercial/TRL8as a qualified curator route estimate for SOEC, supported by contemporary industrial demonstration context. This is not a manufacturer/source-assigned numeric TRL for the exact1 MW model or validation of steam/pressure interfaces and durability. Evidence classification: current source scope and curator route or proxy assessment. Confidence: explicit unresolved route vs exact model classification. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 15. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-2068. Technological representativeness: 4. Basis: Curator assessment of a hybrid literature/compiler model with selected updated membrane/alloy/PCS/drive and utility assumptions. Established route maturity does not make exact bill and performance representative measured production. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 16. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-2068. Geographical representativeness: 3. Basis: Curator assessment of generic regional supplier/material references and scenario electricity choices, not a matched or production-weighted factory population. Selected supply scenarios do not independently establish equipment manufacturing geography. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 17. Source reference: https://doi.org/10.1016/j.est.2021.102759 Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-2068. Temporal representativeness: 4. Basis: Curator assessment of mixed historical source materials, IndWEDe/manufacturer scenario assumptions and later compiler adaptations.2019/2030/2050electricity scenarios,2021publication and current equipment availability are not full-inventory observation periods. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json Evidence: 18. Source reference: https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Doi: 10.1016/j.est.2021.102759 Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production Publications: 1. Scientific authors: 1. Name: Niklas Gerloff Publications: 1. Scientific authors: 1. Orcid: Not set Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759 Publications: 1. Relation: primary_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2021 Publications: 2. Doi: Not set Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland Publications: 2. Scientific authors: 1. Name: Tom Smolinka Publications: 2. Scientific authors: 1. Orcid: Not set Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe Publications: 2. Scientific authors: 2. Orcid: Not set Publications: 2. Scientific authors: 3. Name: Philip Sterchele Publications: 2. Scientific authors: 3. Orcid: Not set Publications: 2. Scientific authors: 4. Name: Andreas Palzer Publications: 2. Scientific authors: 4. Orcid: Not set Publications: 2. Scientific authors: 5. Name: Franz Lehner Publications: 2. Scientific authors: 5. Orcid: Not set Publications: 2. Scientific authors: 6. Name: Malte Jansen Publications: 2. Scientific authors: 6. Orcid: Not set Publications: 2. Scientific authors: 7. Name: Steffen Kiemel Publications: 2. Scientific authors: 7. Orcid: Not set Publications: 2. Scientific authors: 8. Name: Robert Miehe Publications: 2. Scientific authors: 8. Orcid: Not set Publications: 2. Scientific authors: 9. Name: Sylvia Wahren Publications: 2. Scientific authors: 9. Orcid: Not set Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann Publications: 2. Scientific authors: 10. Orcid: Not set Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: technical_report Publications: 2. Publication year: 2018 |
|
| Version metadata | System boundary | Foreground reference: 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. | Material/component supply, recorded forming services and assembly electricity for one SOEC stack. Hydrogen-production utilities, lifetime multiplication and the paired finished-equipment treatment are modelled separately. | |
| Version metadata | Technological representativeness | 2 | 4 | |
| Version metadata | Technology description | Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. | SOEC stack represented by material supply, forming/processing and component purchases. This unit represents one manufactured component, separately from the operating model's lifetime purchases. Crofer-type interconnect, composition-specific YSZ/YDC oxides, nominal glass seal and LSM contact ceramic are supplied through separate engineering references. | |
| Version metadata | Temporal representativeness | 2 | 4 | |
| Version metadata | Limitations on use | Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. | Source component quantities and estimated assembly energy do not establish a measured complete manufacturer bill of materials, actual industrial yield or equivalent supplier grades/performance. SM1 BoP energy totals follow approximately linear 1 MW scaling, despite the paragraph's 0.7 exponent; they are about 7.94 times a reconstruction using that exponent. Some component intensities may already be scaled. Original H2_generation and data_generation_material workbooks were not recovered, limiting exact reconstruction. Source La/Sr quantities are deferred to an unrecovered material-generation sheet; the 2.1 kg LSM reference does not prove older 21 kg precursor entries were decimal errors. Alloy, ceramic and glass manufacture are not a validated complete industrial stack BOM. Lanthanum-reject fate and fluoride/PFC/bath coverage remain unresolved, and native uncertain rolling makeup remains upstream. | |
| Version metadata | Description | Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. |
Manufacturing reference for one stack of a nominal 1 MWe SOEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations. | Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries. The description states the resulting reference flow, process boundary and remaining source limitations. |
| Version metadata | Intended application | Not set | Provision of one SOEC electrolyzer stack in compatible operating or equipment scenarios with separate lifetime and retirement accounting. | Apply reviewed discovery metadata and change explanations from the curated release. |
| Version metadata | Name | electrolyzer production, 1MWe, SOEC, Stack | electrolyzer production, 1MWe, SOEC, stack | Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content