Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack.
The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.
Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Dataset details
Classification, keywords, bookmarks and download counts.
Classification
Hydrogen via electrolysis (energy/hydrogen/electrolysis)
Bookmarks
0
Raw file downloads
0
Generated export downloads
2
Classification path:
Energy >
Hydrogen >
Hydrogen via electrolysis
Keywords
hydrogen
hydrogen via electrolysis
electrolysis
Bookmarking is available only on the latest published dataset record.
Metadata & sourcesMethods, scope, reference years, publications, contributors, projects and funding.
Source
Source documentation, background profiles and references.
Scientific journal publication
Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Inventory changes relative to source:Not assessed
Equivalence to the original source inventory has not been established.
Background database
ecoinvent / 3.9
Background system model
cut-off
Biosphere database
ecoinvent / 3.9
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Reference years, modelling and allocation methods, contributors, publications, projects and funding.
Declarations describe this version's foreground inventory. Missing information is not evidence of a particular allocation method or data origin.
Source publication year
2021
Inventory reference year
Not specified
Foreground modelling approach
Not specified
Allocated product inventory
Not specified
Allocation or multifunctionality treatment
Not specified
Inventory contributions
Not specified
Projects
Not specified
Funding
Not specified
Methodology notes
The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.
System boundary
Foreground reference: 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.
Included life cycle stages
Manufacturing
Technology description
Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack.
Use limitations
Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Data origins
Literature
Other fields not yet completed (6)
Data period start year, Data period end year, Valid until year, Multifunctionality applicable, Process type, Intended application
Publications (2)
Citation
Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Title
Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Doi
10.1016/j.est.2021.102759
Url
https://doi.org/10.1016/j.est.2021.102759
Source type
Scientific journal
Publication year
2021
Relation
Primary source
Authors
Niklas Gerloff
Citation
Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Title
Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Tom Smolinka; Nikolai Wiebe; Philip Sterchele; Andreas Palzer; Franz Lehner; Malte Jansen; Steffen Kiemel; Robert Miehe; Sylvia Wahren; Fabian Zimmermann
Evidence and qualifications (6)
Target field
data_origins
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Target field
included_life_cycle_stages
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
name
Qualification
Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Target field
publications
Origin
Source import
Source reference
Existing published CLIC inventory documentation
Source location
source
Qualification
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Publisher-deposited registry /message/title, /message/published and /message/author
Qualification
Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Qualification
Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Technology characterizationScale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Early commercial
Design capacity
1
Design capacity unit
MW
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scaleHigher is more mature.9: routine commercial deployment8: commercial, but still niche or scaling7: first-commercial or advanced demonstration6: engineering-scale demonstration5: pilot or large prototype4: bench or lab validated3: research-stage conceptTechnology readiness level
123456789
earlymature
1 to 5 scaleLower is better.1: strong market- or operating-data basis2: commercially plausible, but still somewhat specific3: partly representative, with modelling or adaptation bias4: pilot, proxy-based, scaled-up, or prospective5: weak representation of the real technology stateTechnological representativeness
12345
strongweak
1 to 5 scaleLower is better.1: geography matches the claimed scope well2: regionally credible, but broader or less exact3: generic regional or global proxy4: weak proxy or clear geographic mismatch5: geography is effectively unsupportedGeographical representativeness
12345
strongweak
1 to 5 scaleLower is better.1: current for that technology class2: slightly dated, but still good3: dated enough to need caution4: stale, pilot-era, or prospective relative to current practice5: clearly not representative of the current stateTemporal representativeness
12345
strongweak
Missing exchange uncertainty generation:
Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
Acidification505.084
mol H+-Eq / unit
Climate change87589.6
kg CO2-Eq / unit
Freshwater ecotoxicity407996
CTUe / unit
Freshwater eutrophication37.9526
kg P-Eq / unit
Marine eutrophication48.4798
kg N-Eq / unit
Terrestrial eutrophication492.027
mol N-Eq / unit
Human toxicity, cancer0.000118999
CTUh / unit
Human toxicity, non-cancer0.00137232
CTUh / unit
Ionising radiation25384.3
kBq U235-Eq / unit
Land use361752
dimensionless / unit
Ozone depletion0.0012832
kg CFC-11-Eq / unit
Particulate matter0.00250281
disease incidence / unit
Photochemical ozone formation178.771
kg NMVOC-Eq / unit
Resource use, fossils1.2517e+06
MJ, net calorific value / unit
Resource use, minerals and metals0.339764
kg Sb-Eq / unit
Water use2.1892e+06
m3 world Eq deprived / unit
Screening result
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Show all 16 indicator totals
Acidification505.084
mol H+-Eq / unit
Climate change87589.6
kg CO2-Eq / unit
Freshwater ecotoxicity407996
CTUe / unit
Freshwater eutrophication37.9526
kg P-Eq / unit
Marine eutrophication48.4798
kg N-Eq / unit
Terrestrial eutrophication492.027
mol N-Eq / unit
Human toxicity, cancer0.000118999
CTUh / unit
Human toxicity, non-cancer0.00137232
CTUh / unit
Ionising radiation25384.3
kBq U235-Eq / unit
Land use361752
dimensionless / unit
Ozone depletion0.0012832
kg CFC-11-Eq / unit
Particulate matter0.00250281
disease incidence / unit
Photochemical ozone formation178.771
kg NMVOC-Eq / unit
Resource use, fossils1.2517e+06
MJ, net calorific value / unit
Resource use, minerals and metals0.339764
kg Sb-Eq / unit
Water use2.1892e+06
m3 world Eq deprived / unit
Calculation details
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-09-30 13:58 UTC. These screening results do not replace a reviewed comparative LCA.
Dataset contents
Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.
Outputs
Reference flow1 rowReference production exchanges extracted from the uploaded inventory.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
electrolyzer production, 1MWe, SOEC, Stack
RER
electrolyzer, 1MWe, SOEC, Stack
1
unit
-
Reference flow
Inputs
Technosphere inputs16 rowsLinked foreground or background product inputs used by this dataset.
Exchange
Reference / categories
Amount
Unit
Metadata
Climate change contribution
market for sheet rolling, chromium steel
GLO
sheet rolling, chromium steel
8976.1
kilogram
Metadata (1)
Comment
air electrode
19.4571mol H+-Eq / unit
3.9% of total
3856.03kg CO2-Eq / unit
4.4% of total
70212.2CTUe / unit
17.2% of total
1.92012kg P-Eq / unit
5.1% of total
3.58421kg N-Eq / unit
7.4% of total
38.0895mol N-Eq / unit
7.7% of total
3.5088e-05CTUh / unit
29.5% of total
0.000116249CTUh / unit
8.5% of total
2067.07kBq U235-Eq / unit
8.1% of total
21017.9dimensionless / unit
5.8% of total
7.5189e-05kg CFC-11-Eq / unit
5.9% of total
0.00021656disease incidence / unit
8.7% of total
13.9434kg NMVOC-Eq / unit
7.8% of total
61730.9MJ, net calorific value / unit
4.9% of total
0.0600364kg Sb-Eq / unit
17.7% of total
1205.49m3 world Eq deprived / unit
0.1% of total
BAFU:2025
market for steel, chromium steel 18/8, hot rolled
GLO
steel, chromium steel 18/8, hot rolled
8976.1
kilogram
Metadata (1)
Comment
air electrode
19.4571mol H+-Eq / unit
3.9% of total
3856.03kg CO2-Eq / unit
4.4% of total
70212.2CTUe / unit
17.2% of total
1.92012kg P-Eq / unit
5.1% of total
3.58421kg N-Eq / unit
7.4% of total
38.0895mol N-Eq / unit
7.7% of total
3.5088e-05CTUh / unit
29.5% of total
0.000116249CTUh / unit
8.5% of total
2067.07kBq U235-Eq / unit
8.1% of total
21017.9dimensionless / unit
5.8% of total
7.5189e-05kg CFC-11-Eq / unit
5.9% of total
0.00021656disease incidence / unit
8.7% of total
13.9434kg NMVOC-Eq / unit
7.8% of total
61730.9MJ, net calorific value / unit
4.9% of total
0.0600364kg Sb-Eq / unit
17.7% of total
1205.49m3 world Eq deprived / unit
0.1% of total
BAFU:2025
market for praseodymium oxide
GLO
praseodymium oxide
9
kilogram
Metadata (1)
Comment
screen printing
1.08835mol H+-Eq / unit
0.2% of total
369.558kg CO2-Eq / unit
0.4% of total
2378.65CTUe / unit
0.6% of total
0.112295kg P-Eq / unit
0.3% of total
0.178079kg N-Eq / unit
0.4% of total
1.80992mol N-Eq / unit
0.4% of total
2.5556e-07CTUh / unit
0.2% of total
4.9747e-06CTUh / unit
0.4% of total
47.1069kBq U235-Eq / unit
0.2% of total
842.835dimensionless / unit
0.2% of total
2.8401e-05kg CFC-11-Eq / unit
2.2% of total
9.1137e-06disease incidence / unit
0.4% of total
1.01002kg NMVOC-Eq / unit
0.6% of total
6473.44MJ, net calorific value / unit
0.5% of total
0.00272647kg Sb-Eq / unit
0.8% of total
100.166m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
7.5
kilogram
Metadata (1)
Comment
screen printing
13.9762mol H+-Eq / unit
2.8% of total
73.6845kg CO2-Eq / unit
0.1% of total
582.077CTUe / unit
0.1% of total
0.289018kg P-Eq / unit
0.8% of total
0.178885kg N-Eq / unit
0.4% of total
2.47098mol N-Eq / unit
0.5% of total
9.2010e-08CTUh / unit
0.1% of total
3.4154e-06CTUh / unit
0.2% of total
18.5094kBq U235-Eq / unit
0.1% of total
455.93dimensionless / unit
0.1% of total
1.4283e-06kg CFC-11-Eq / unit
0.1% of total
1.5478e-05disease incidence / unit
0.6% of total
1.37203kg NMVOC-Eq / unit
0.8% of total
881.728MJ, net calorific value / unit
0.1% of total
0.000758189kg Sb-Eq / unit
0.2% of total
37.1757m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for zirconium oxide
GLO
zirconium oxide
170.7
kilogram
Metadata (1)
Comment
blocking layer
2.13374mol H+-Eq / unit
0.4% of total
510.145kg CO2-Eq / unit
0.6% of total
2067.6CTUe / unit
0.5% of total
0.264692kg P-Eq / unit
0.7% of total
0.437065kg N-Eq / unit
0.9% of total
4.17985mol N-Eq / unit
0.8% of total
5.1153e-07CTUh / unit
0.4% of total
2.2713e-05CTUh / unit
1.7% of total
278.92kBq U235-Eq / unit
1.1% of total
4635.97dimensionless / unit
1.3% of total
1.2606e-05kg CFC-11-Eq / unit
1.0% of total
1.8617e-05disease incidence / unit
0.7% of total
1.47241kg NMVOC-Eq / unit
0.8% of total
8238.97MJ, net calorific value / unit
0.7% of total
0.0068207kg Sb-Eq / unit
2.0% of total
204.695m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for samarium-europium-gadolinium oxide
GLO
samarium-europium-gadolinium oxide
14.8
kilogram
Metadata (1)
Comment
blocking layer
2.39679mol H+-Eq / unit
0.5% of total
817.832kg CO2-Eq / unit
0.9% of total
5248.43CTUe / unit
1.3% of total
0.248685kg P-Eq / unit
0.7% of total
0.389438kg N-Eq / unit
0.8% of total
3.95873mol N-Eq / unit
0.8% of total
5.2106e-07CTUh / unit
0.4% of total
1.0880e-05CTUh / unit
0.8% of total
102.608kBq U235-Eq / unit
0.4% of total
1812.64dimensionless / unit
0.5% of total
5.9195e-05kg CFC-11-Eq / unit
4.6% of total
1.9993e-05disease incidence / unit
0.8% of total
2.2329kg NMVOC-Eq / unit
1.2% of total
14346MJ, net calorific value / unit
1.1% of total
0.00597962kg Sb-Eq / unit
1.8% of total
220.767m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for cerium oxide
GLO
cerium oxide
91.5
kilogram
Metadata (1)
Comment
screen printing
2.32116mol H+-Eq / unit
0.5% of total
730.846kg CO2-Eq / unit
0.8% of total
4927.55CTUe / unit
1.2% of total
0.219537kg P-Eq / unit
0.6% of total
0.419155kg N-Eq / unit
0.9% of total
4.25071mol N-Eq / unit
0.9% of total
1.1462e-06CTUh / unit
1.0% of total
1.1702e-05CTUh / unit
0.9% of total
116.774kBq U235-Eq / unit
0.5% of total
2423.73dimensionless / unit
0.7% of total
0.000108838kg CFC-11-Eq / unit
8.5% of total
2.0551e-05disease incidence / unit
0.8% of total
2.03007kg NMVOC-Eq / unit
1.1% of total
12510.4MJ, net calorific value / unit
1.0% of total
0.00617057kg Sb-Eq / unit
1.8% of total
211.055m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for samarium-europium-gadolinium oxide
GLO
samarium-europium-gadolinium oxide
22.9
kilogram
Metadata (1)
Comment
screen printing
3.70855mol H+-Eq / unit
0.7% of total
1265.43kg CO2-Eq / unit
1.4% of total
8120.88CTUe / unit
2.0% of total
0.384789kg P-Eq / unit
1.0% of total
0.602576kg N-Eq / unit
1.2% of total
6.12533mol N-Eq / unit
1.2% of total
8.0624e-07CTUh / unit
0.7% of total
1.6834e-05CTUh / unit
1.2% of total
158.765kBq U235-Eq / unit
0.6% of total
2804.69dimensionless / unit
0.8% of total
9.1592e-05kg CFC-11-Eq / unit
7.1% of total
3.0935e-05disease incidence / unit
1.2% of total
3.45496kg NMVOC-Eq / unit
1.9% of total
22197.5MJ, net calorific value / unit
1.8% of total
0.00925225kg Sb-Eq / unit
2.7% of total
341.593m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for lanthanum oxide
GLO
lanthanum oxide
21
kilogram
Metadata (1)
Comment
electrolyte - to check
0.595033mol H+-Eq / unit
0.1% of total
189.301kg CO2-Eq / unit
0.2% of total
1268.13CTUe / unit
0.3% of total
0.0569566kg P-Eq / unit
0.2% of total
0.106114kg N-Eq / unit
0.2% of total
1.07641mol N-Eq / unit
0.2% of total
2.7340e-07CTUh / unit
0.2% of total
2.9627e-06CTUh / unit
0.2% of total
29.3813kBq U235-Eq / unit
0.1% of total
600.056dimensionless / unit
0.2% of total
2.6261e-05kg CFC-11-Eq / unit
2.0% of total
5.2304e-06disease incidence / unit
0.2% of total
0.524627kg NMVOC-Eq / unit
0.3% of total
3251.08MJ, net calorific value / unit
0.3% of total
0.00156975kg Sb-Eq / unit
0.5% of total
54.1917m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for strontium carbonate
GLO
strontium carbonate
21
kilogram
Metadata (1)
Comment
electrolyte - to check
0.484295mol H+-Eq / unit
0.1% of total
66.2298kg CO2-Eq / unit
0.1% of total
2064.98CTUe / unit
0.5% of total
0.0476807kg P-Eq / unit
0.1% of total
0.172971kg N-Eq / unit
0.4% of total
1.33274mol N-Eq / unit
0.3% of total
6.5161e-08CTUh / unit
0.1% of total
2.0241e-06CTUh / unit
0.1% of total
8.86465kBq U235-Eq / unit
0.0% of total
366.729dimensionless / unit
0.1% of total
3.1439e-06kg CFC-11-Eq / unit
0.2% of total
4.1211e-06disease incidence / unit
0.2% of total
0.222124kg NMVOC-Eq / unit
0.1% of total
775.119MJ, net calorific value / unit
0.1% of total
0.00116906kg Sb-Eq / unit
0.3% of total
40.7387m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for aluminium oxide, metallurgical
IAI Area, EU27 & EFTA
aluminium oxide, metallurgical
6.4
kilogram
Metadata (1)
Comment
electrolyte + H2 electrode
0.0762742mol H+-Eq / unit
0.0% of total
7.54244kg CO2-Eq / unit
0.0% of total
25.7193CTUe / unit
0.0% of total
0.00233636kg P-Eq / unit
0.0% of total
0.0113558kg N-Eq / unit
0.0% of total
0.116948mol N-Eq / unit
0.0% of total
2.6434e-08CTUh / unit
0.0% of total
4.3626e-07CTUh / unit
0.0% of total
1.1726kBq U235-Eq / unit
0.0% of total
17.8807dimensionless / unit
0.0% of total
1.8360e-07kg CFC-11-Eq / unit
0.0% of total
5.3612e-07disease incidence / unit
0.0% of total
0.0403545kg NMVOC-Eq / unit
0.0% of total
106.723MJ, net calorific value / unit
0.0% of total
1.4935e-05kg Sb-Eq / unit
0.0% of total
1.97694m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for boric oxide
GLO
boric oxide
6.4
kilogram
Metadata (1)
Comment
electrolyte + H2 electrode
0.13949mol H+-Eq / unit
0.0% of total
10.0255kg CO2-Eq / unit
0.0% of total
40.2165CTUe / unit
0.0% of total
0.00406995kg P-Eq / unit
0.0% of total
0.0110655kg N-Eq / unit
0.0% of total
0.118815mol N-Eq / unit
0.0% of total
7.8578e-09CTUh / unit
0.0% of total
1.1101e-07CTUh / unit
0.0% of total
3.7046kBq U235-Eq / unit
0.0% of total
68.3024dimensionless / unit
0.0% of total
3.4951e-07kg CFC-11-Eq / unit
0.0% of total
3.3610e-06disease incidence / unit
0.1% of total
0.05229kg NMVOC-Eq / unit
0.0% of total
213.252MJ, net calorific value / unit
0.0% of total
0.0198976kg Sb-Eq / unit
5.9% of total
5.45531m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for barium oxide
GLO
barium oxide
6.4
kilogram
Metadata (1)
Comment
electrolyte + H2 electrode
0.13949mol H+-Eq / unit
0.0% of total
10.0255kg CO2-Eq / unit
0.0% of total
40.2165CTUe / unit
0.0% of total
0.00406995kg P-Eq / unit
0.0% of total
0.0110655kg N-Eq / unit
0.0% of total
0.118815mol N-Eq / unit
0.0% of total
7.8578e-09CTUh / unit
0.0% of total
1.1101e-07CTUh / unit
0.0% of total
3.7046kBq U235-Eq / unit
0.0% of total
68.3024dimensionless / unit
0.0% of total
3.4951e-07kg CFC-11-Eq / unit
0.0% of total
3.3610e-06disease incidence / unit
0.1% of total
0.05229kg NMVOC-Eq / unit
0.0% of total
213.252MJ, net calorific value / unit
0.0% of total
0.0198976kg Sb-Eq / unit
5.9% of total
5.45531m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for silicone product
RER
silicone product
6.4
kilogram
Metadata (1)
Comment
electrolyte + H2 electrode
0.0631314mol H+-Eq / unit
0.0% of total
17.8729kg CO2-Eq / unit
0.0% of total
197.862CTUe / unit
0.0% of total
0.00298666kg P-Eq / unit
0.0% of total
0.013842kg N-Eq / unit
0.0% of total
0.145524mol N-Eq / unit
0.0% of total
5.3426e-09CTUh / unit
0.0% of total
1.3961e-07CTUh / unit
0.0% of total
2.17068kBq U235-Eq / unit
0.0% of total
63.5771dimensionless / unit
0.0% of total
1.0812e-05kg CFC-11-Eq / unit
0.8% of total
7.8630e-07disease incidence / unit
0.0% of total
0.0520325kg NMVOC-Eq / unit
0.0% of total
316.782MJ, net calorific value / unit
0.0% of total
7.1098e-05kg Sb-Eq / unit
0.0% of total
4.19709m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
136.6
kilogram
Metadata (1)
Comment
firing of cell
254.554mol H+-Eq / unit
50.4% of total
1342.04kg CO2-Eq / unit
1.5% of total
10601.6CTUe / unit
2.6% of total
5.26399kg P-Eq / unit
13.9% of total
3.25809kg N-Eq / unit
6.7% of total
45.0048mol N-Eq / unit
9.1% of total
1.6758e-06CTUh / unit
1.4% of total
6.2206e-05CTUh / unit
4.5% of total
337.118kBq U235-Eq / unit
1.3% of total
8304.01dimensionless / unit
2.3% of total
2.6014e-05kg CFC-11-Eq / unit
2.0% of total
0.000281905disease incidence / unit
11.3% of total
24.9892kg NMVOC-Eq / unit
14.0% of total
16059.2MJ, net calorific value / unit
1.3% of total
0.0138091kg Sb-Eq / unit
4.1% of total
677.094m3 world Eq deprived / unit
0.0% of total
BAFU:2025
market group for electricity, low voltage
GLO
electricity, low voltage
1.22e+05
kilowatt hour
Metadata (1)
Comment
assembly energy
184.494mol H+-Eq / unit
36.5% of total
74467kg CO2-Eq / unit
85.0% of total
230008CTUe / unit
56.4% of total
27.2112kg P-Eq / unit
71.7% of total
35.5216kg N-Eq / unit
73.3% of total
345.139mol N-Eq / unit
70.1% of total
4.3428e-05CTUh / unit
36.5% of total
0.00100131CTUh / unit
73.0% of total
20141.3kBq U235-Eq / unit
79.3% of total
297252dimensionless / unit
82.2% of total
0.000763648kg CFC-11-Eq / unit
59.5% of total
0.0016557disease incidence / unit
66.2% of total
113.379kg NMVOC-Eq / unit
63.4% of total
1.0427e+06MJ, net calorific value / unit
83.3% of total
0.131554kg Sb-Eq / unit
38.7% of total
2.1848e+06m3 world Eq deprived / unit
99.8% of total
BAFU:2025
Parameters0 source definitions · values, formulas and uncertainty.
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Supply-chain graph
Direct technosphere and natural-resource inputs appear on the left; emissions and any direct consuming datasets appear on the right.
Current datasetTechnosphere inputsEnvironmental resource inputsEmissions
1 CLIC node
and 14 background boundary nodes shown.
Direct inputs appear to the left of the current dataset, while emissions appear to the right. Only direct consumers among the latest published CLIC inventories are shown. Consumer arrows show the input amount per reference flow of the consuming dataset. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Downloads & files
This historical version remains available for citation and download, but a newer public version is now current.
Add to download basket
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders…
Published · Latest
Show full version history table (2 versions)
Version
Published
Reason for this version
Link
Version 1.0.1
2026-11-03
Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries.
First published inventory; no earlier version is available for comparison.
Review & discussionPublication provenance, scientific review and community discussion.
Public review record
Curator-led bulk import. Public evidence is shown without participant
accounts, assignments, recommendations, or private editor notes.
Show reviewHide review
Publication route
Curator-led bulk import
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.