Hydrogen via electrolysis

electrolyzer production, 1MWe, SOEC, stack

Reference product electrolyzer, 1MWe, SOEC, Stack RER

Published Version 1.0.1 Not assessed Latest published

Stable dataset identity electrolyzer-production-1mwe-soec-stack

Unit
unit
Reuse license
CC BY 4.0
Published
2026-11-03
Version
1.0.1
Technology maturity
See quality profile

Published inventory

Overview

Process description and catalog context. View scientific metadata

Description

Manufacturing reference for one stack of a nominal 1 MWe SOEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations.

Dataset details

Classification, keywords, bookmarks and download counts.

Classification
Hydrogen via electrolysis (energy/hydrogen/electrolysis)
Bookmarks
0
Raw file downloads
0
Generated export downloads
0

Classification path: Energy > Hydrogen > Hydrogen via electrolysis

Log in to bookmark
Metadata & sources Methods, scope, reference years, publications, contributors, projects and funding.

Source

Source documentation, background profiles and references.

Scientific journal publication

Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759

Inventory changes relative to source: Not assessed

Equivalence to the original source inventory has not been established.

Background database
ecoinvent / 3.9
Background system model
cut-off
Biosphere database
ecoinvent / 3.9

These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.

Technology characterization Scale, utilization, production, lifetime, technology readiness and representativeness.
Commercial maturity stage
Early commercial
Design capacity
1
Design capacity unit
MW
Capacity factor
Not provided
Annual production volume
Not provided
Annual production volume unit
Not provided
Annual production volume year
Not provided
Plant lifetime
Not provided
TRL scale Higher is more mature. 9: routine commercial deployment 8: commercial, but still niche or scaling 7: first-commercial or advanced demonstration 6: engineering-scale demonstration 5: pilot or large prototype 4: bench or lab validated 3: research-stage concept Technology readiness level
1 to 5 scale Lower is better. 1: strong market- or operating-data basis 2: commercially plausible, but still somewhat specific 3: partly representative, with modelling or adaptation bias 4: pilot, proxy-based, scaled-up, or prospective 5: weak representation of the real technology state Technological representativeness
1 to 5 scale Lower is better. 1: geography matches the claimed scope well 2: regionally credible, but broader or less exact 3: generic regional or global proxy 4: weak proxy or clear geographic mismatch 5: geography is effectively unsupported Geographical representativeness
1 to 5 scale Lower is better. 1: current for that technology class 2: slightly dated, but still good 3: dated enough to need caution 4: stale, pilot-era, or prospective relative to current practice 5: clearly not representative of the current state Temporal representativeness

Missing exchange uncertainty generation: Not requested

Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.

Inventory & impacts 13 exchanges · exchange table, supply-chain graph and environmental screening.

Precalculated screening profile

Environmental impacts

Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.

Climate change 144107 kg CO2-Eq / unit
Screening result

This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.

Show all 16 indicator totals
Acidification 653.803 mol H+-Eq / unit
Climate change 144107 kg CO2-Eq / unit
Freshwater ecotoxicity 539668 CTUe / unit
Freshwater eutrophication 54.4424 kg P-Eq / unit
Marine eutrophication 81.7271 kg N-Eq / unit
Terrestrial eutrophication 818.775 mol N-Eq / unit
Human toxicity, cancer 0.000480075 CTUh / unit
Human toxicity, non-cancer 0.00192404 CTUh / unit
Ionising radiation 47573 kBq U235-Eq / unit
Land use 520190 dimensionless / unit
Ozone depletion 0.00223735 kg CFC-11-Eq / unit
Particulate matter 0.00458328 disease incidence / unit
Photochemical ozone formation 305.46 kg NMVOC-Eq / unit
Resource use, fossils 2.0350e+06 MJ, net calorific value / unit
Resource use, minerals and metals 1.57772 kg Sb-Eq / unit
Water use 2.3463e+06 m3 world Eq deprived / unit
Calculation details

Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact 4e70d56a85b1 · calculated 2026-11-03 09:13 UTC. These screening results do not replace a reviewed comparative LCA.

Dataset contents

Reference flows, emissions, technosphere inputs, and natural resources in this published snapshot.

Outputs

Reference flow 1 row Reference production exchanges extracted from the uploaded inventory.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
electrolyzer production, 1MWe, SOEC, stack
RER
electrolyzer, 1MWe, SOEC, Stack
1
unit - Reference flow

Inputs

Technosphere inputs 12 rows Linked foreground or background product inputs used by this dataset.
Exchange Reference / categories Amount Unit Metadata Climate change contribution
market for sheet rolling, chromium steel
GLO
sheet rolling, chromium steel
8976.1
kilogram
3856.03 kg CO2-Eq / unit 2.7% of total
BAFU:2025
market for praseodymium oxide
GLO
praseodymium oxide
9
kilogram
369.558 kg CO2-Eq / unit 0.3% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
7.5
kilogram
73.6845 kg CO2-Eq / unit 0.1% of total
BAFU:2025
market for zirconium oxide
GLO
zirconium oxide
160.02
kilogram
478.227 kg CO2-Eq / unit 0.3% of total
BAFU:2025
market for yttrium oxide
GLO
yttrium oxide
25.5
kilogram
106.846 kg CO2-Eq / unit 0.1% of total
BAFU:2025
market for cerium oxide
GLO
cerium oxide
98.25
kilogram
784.792 kg CO2-Eq / unit 0.5% of total
BAFU:2025
market for yttrium oxide
GLO
yttrium oxide
16.11
kilogram
67.5173 kg CO2-Eq / unit 0.0% of total
BAFU:2025
market for nickel, class 1
GLO
nickel, class 1
136.6
kilogram
1342.04 kg CO2-Eq / unit 0.9% of total
BAFU:2025
market group for electricity, low voltage
GLO
electricity, low voltage
1.22e+05
kilowatt hour
74467 kg CO2-Eq / unit 51.7% of total
BAFU:2025
glass seal, SOEC, barium alumino-borosilicate
25.6
kilogram
60.7944 kg CO2-Eq / unit 0.0% of total
contact ceramic, lanthanum strontium manganite, La0.8Sr0.2MnO3
2.1
kilogram
18.0016 kg CO2-Eq / unit 0.0% of total
ferritic steel, electrolysis interconnect, Crofer 22 APU type
8976.1
kilogram -
62482.1 kg CO2-Eq / unit 43.4% of total
Parameters 0 source definitions · values, formulas and uncertainty.

Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.

No parameter definitions were supplied with this inventory snapshot.

Reuse and provenance

Downloads & files

Add this version to your basket, inspect original uploads, or reuse it in your LCA software.

Add to download basket

Original source files are currently unavailable, but you can still add this version to your basket for generated package export.

Log in to add to basket
Raw uploaded files 0 files preserved with this version.
Original uploaded files were not included in the inventory archive. Generated inventory exports remain available.
Versions & changes 2 versions · change rationale, release notes and comparisons.

Version history

Published versions are immutable and remain available.

Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.

  • Version 1.0.1 revises version 1.0.0.
  1. Version 1.0.0
    Published

    First published inventory; no earlier version is available for comparison.

    Superseded
  2. Version 1.0.1
    Published

    Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders…

    Published · Viewing · Latest
Show full version history table (2 versions)
Version Published Reason for this version Link
Version 1.0.1 2026-11-03 Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries. Current view
Version 1.0.0 Superseded Published 2026-07-15 First published inventory; no earlier version is available for comparison. Open version
About this version

Why this version changed

Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries.

Release notes

The ferritic alloy replaces the 18/8 steel placeholder at unchanged plate mass. Matched yttrium-containing oxide purchases replace mixed Sm/Eu/Gd oxide impact proxies. Finished LSM and glass references own their precursor and manufacturing inputs, replacing the old separate placeholders; their source-specific loading and process limitations remain explicit.

Changes from version 1.0.0 Compare this version with its predecessor. Exchanges are grouped by type and change; biosphere labels include their environmental compartments. Open the base version. Show changes Hide changes

Why this version changed

Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries.

Public revision record

This comparison is permanently visible with the published version so users can assess every detected change before reuse.

Modified exchanges
3
Added exchanges
5
Removed exchanges
9
Inventory metadata
0
Version metadata
12
Technosphere exchanges modified 2
Technosphere exchanges modified
Exchange / scope Field Previous value Revised value Reason
market for zirconium oxide (technosphere / GLO / kilogram) Amount 170.7 160.01991086063632 The quantity of zirconium oxide follows the selected material or process reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for cerium oxide (technosphere / GLO / kilogram) Amount 91.5 98.25386326929127 The quantity of cerium oxide follows the selected material or process reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
Technosphere exchanges added 5
Technosphere exchanges added
Exchange / scope Field Previous value Revised value Reason
market for yttrium oxide (technosphere / GLO / kilogram) Amount Not present 25.49931784143422 kilogram The yttrium oxide entry supplies the material, process or treatment required by the revised reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for yttrium oxide (technosphere / GLO / kilogram) Amount Not present 16.113284777632217 kilogram
glass seal production, SOEC, barium alumino-borosilicate (technosphere / GLO / kilogram) Amount Not present 25.6 kilogram The glass seal, SOEC, barium alumino-borosilicate entry supplies the material, process or treatment required by the revised reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
contact ceramic production, lanthanum strontium manganite, la0.8sr0.2mno3 (technosphere / GLO / kilogram) Amount Not present 2.1 kilogram The contact ceramic, lanthanum strontium manganite, La0.8Sr0.2MnO3 entry supplies the material, process or treatment required by the revised reference. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
ferritic steel production, electrolysis interconnect, crofer 22 apu type (technosphere / GLO / kilogram) Amount Not present 8976.1 kilogram Use the ferritic Crofer22APU-type interconnect material reference for the high-temperature SOEC function instead of generic austenitic 18/8 chromium steel. The 8976.1 kg plate mass and separate rolling service are retained. Alloy composition and manufacturing remain qualified engineering assumptions rather than a verified full-scale stack bill of materials.
Technosphere exchanges removed 9
Technosphere exchanges removed
Exchange / scope Field Previous value Revised value Reason
market for steel, chromium steel 18/8, hot rolled (technosphere / GLO / kilogram) Amount 8976.1 kilogram Not present Use the ferritic Crofer22APU-type interconnect material reference for the high-temperature SOEC function instead of generic austenitic 18/8 chromium steel. The 8976.1 kg plate mass and separate rolling service are retained. Alloy composition and manufacturing remain qualified engineering assumptions rather than a verified full-scale stack bill of materials.
market for samarium-europium-gadolinium oxide (technosphere / GLO / kilogram) Amount 14.8 kilogram Not present The former samarium-europium-gadolinium oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for samarium-europium-gadolinium oxide (technosphere / GLO / kilogram) Amount 22.9 kilogram Not present
market for lanthanum oxide (technosphere / GLO / kilogram) Amount 21 kilogram Not present The former lanthanum oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for strontium carbonate (technosphere / GLO / kilogram) Amount 21 kilogram Not present Purchase the finished La0.8Sr0.2MnO3 contact ceramic at the author-model 2.1 kg stack loading instead of the two separate 21 kg lanthanum-oxide/strontium-carbonate placeholders. Precursor chemistry and calcination are included inside the ceramic reference. The new loading is a selected author-model basis, not a claim that the old 21 kg entries were decimal errors.
market for aluminium oxide, metallurgical (technosphere / IAI Area, EU27 & EFTA / kilogram) Amount 6.4 kilogram Not present The former aluminium oxide, metallurgical entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for boric oxide (technosphere / GLO / kilogram) Amount 6.4 kilogram Not present The former boric oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for barium oxide (technosphere / GLO / kilogram) Amount 6.4 kilogram Not present The former barium oxide entry is superseded by the revised product/component boundary. The inputs now describe the functional materials of the stack; upstream ceramic and seal manufacture is separated from stack assembly, and the shared glass component owns its recipe once. The SOEC stack now uses Crofer-type ferritic interconnects, YSZ/YDC oxide ceramics, a finished LSM contact material and a separate glass-seal component.
market for silicone product (technosphere / RER / kilogram) Amount 6.4 kilogram Not present Replace the silicone-polymer proxy and the other three 6.4 kg placeholder materials with a finished barium alumino-borosilicate glass-seal reference. Its 25.6 kg loading retains their combined nominal mass and includes the selected glass composition and manufacture. Loading, composition transfer, utilities and manufacturing losses remain engineering assumptions.
Reference flows modified 1
Reference flows modified
Exchange / scope Field Previous value Revised value Reason
electrolyzer production, 1MWe, SOEC, stack (production / RER / unit) Name electrolyzer production, 1MWe, SOEC, Stack electrolyzer production, 1MWe, SOEC, stack Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable.
Metadata changes 12
Metadata changes
Exchange / scope Field Previous value Revised value Reason
Version metadata Inventory evidence types Literature Literature; Engineering estimate No explanation was recorded for this change.
Version metadata Geographical representativeness 2 3
Version metadata Methodology and allocation explanation The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Source model
Gerloff (2021) compares 1 MWe AEC, PEM and SOEC systems under German 2019, 2030, 2050 and renewable-electricity scenarios. The study uses ecoinvent 3.5 cutoff, European/German suppliers, Umberto+, ILCD 2.0 midpoint 2018 and IPCC 2013 GWP. CLIC uses separately declared 3.9 background/biosphere profiles and later material, lifetime and utility adaptations. Publication and scenario years do not date measured inputs.

Manufacturing basis
The reference is one manufactured stack, including 122224.433 kWh assembly electricity. Processing services are separate from installed material mass. Stack assembly electricity is the source's three-stack total divided by three.

Lifetime accounting
The paper assumes 20 years at 8000 h/year and numerically counts three stacks, despite wording about three replacements. SM1 manufacturing-energy totals also include three stacks; the CLIC stack-manufacturing reference uses one third. Operating models separately purchase four PEM/AEC stacks or eight SOEC stacks with corresponding signed retirement. The retrieved IndWEDe document is the Kurzfassung, whereas the cited p. 178 belongs to an unrecovered full report. Selected lifetimes are not independently verified from that page.

Materials
The 8976.1 kg interconnect purchase retains its matching steel-rolling service; an older air-electrode label does not establish that function. YSZ uses 8 mol% Y2O3-stabilized zirconia and YDC uses Ce0.8Y0.2O1.9, reconstructed from 0.425 and 0.262 kg/kW source references with the 0.88 scale exponent. Ceramic incorporation assumes 100% retention with unquantified purchase-boundary loss. Glass-seal loading is a combined 25.6 kg placeholder rather than measured seal geometry. Finished LSM loading is 2.1 kg/MW from an author-model reference.
Version metadata Contributors, publications, projects and supporting evidence Evidence: 1. Origin: source_import
Evidence: 1. Target field: data_origins
Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: source_import
Evidence: 2. Target field: included_life_cycle_stages
Evidence: 2. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Evidence: 2. Source location: name
Evidence: 2. Source reference: Existing published CLIC inventory documentation
Evidence: 3. Origin: source_import
Evidence: 3. Target field: publications
Evidence: 3. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 3. Source location: source
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: editor_verification
Evidence: 4. Target field: publications
Evidence: 4. Qualification: Append/deduplicate these references within this version. Preserve original_citation/original_doi and reconcile any existing primary source. Model ancestry is not automatically inventory authorship.
Evidence: 4. Source location: Publisher-deposited registry /message/title, /message/published and /message/author
Evidence: 4. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759
Evidence: 5. Origin: editor_verification
Evidence: 5. Target field: publications
Evidence: 5. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
Evidence: 5. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers
Evidence: 5. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: methodology_notes
Evidence: 6. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Evidence: 6. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Evidence: 6. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Publications: 1. Doi: 10.1016/j.est.2021.102759
Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Publications: 1. Scientific authors: 1. Name: Niklas Gerloff
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany
Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2021
Publications: 2. Doi: Not set
Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Publications: 2. Scientific authors: 1. Name: Tom Smolinka
Publications: 2. Scientific authors: 1. Orcid: Not set
Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 3. Name: Philip Sterchele
Publications: 2. Scientific authors: 3. Orcid: Not set
Publications: 2. Scientific authors: 4. Name: Andreas Palzer
Publications: 2. Scientific authors: 4. Orcid: Not set
Publications: 2. Scientific authors: 5. Name: Franz Lehner
Publications: 2. Scientific authors: 5. Orcid: Not set
Publications: 2. Scientific authors: 6. Name: Malte Jansen
Publications: 2. Scientific authors: 6. Orcid: Not set
Publications: 2. Scientific authors: 7. Name: Steffen Kiemel
Publications: 2. Scientific authors: 7. Orcid: Not set
Publications: 2. Scientific authors: 8. Name: Robert Miehe
Publications: 2. Scientific authors: 8. Orcid: Not set
Publications: 2. Scientific authors: 9. Name: Sylvia Wahren
Publications: 2. Scientific authors: 9. Orcid: Not set
Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann
Publications: 2. Scientific authors: 10. Orcid: Not set
Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Evidence: 1. Origin: source_import
Evidence: 1. Target field: data_origins
Evidence: 1. Qualification: Tags describe documented input origins of this exact supplied version. Literature does not assert direct measurements; engineering and proxy tags describe stated assumptions, not validated industrial performance.
Evidence: 1. Source location: source
Evidence: 1. Source reference: Existing published CLIC inventory documentation
Evidence: 2. Origin: source_import
Evidence: 2. Target field: included_life_cycle_stages
Evidence: 2. Qualification: Minimum explicitly named stage(s); no assertion that all upstream/downstream stages of the cited study are present. Manufacturing rejects alone do not create an end-of-life stage.
Evidence: 2. Source location: name
Evidence: 2. Source reference: Existing published CLIC inventory documentation
Evidence: 3. Origin: source_import
Evidence: 3. Target field: use_limitations
Evidence: 3. Qualification: Copied version-specific scientific qualification; it remains applicable to this exact reconstruction and is not a claim about the source paper.
Evidence: 3. Source location: description
Evidence: 3. Source reference: Existing published CLIC inventory documentation
Evidence: 4. Origin: editor_verification
Evidence: 4. Target field: publications
Evidence: 4. Qualification: Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers.
Evidence: 4. Source location: DOI registration: title, publication dates and byline
Evidence: 4. Source reference: https://api.crossref.org/works/10.1016%2Fj.est.2021.102759
Evidence: 5. Origin: editor_verification
Evidence: 5. Target field: publications
Evidence: 5. Qualification: Publication author and inventory compiler remain distinct. EST and TUClausthal have different ROR IDs with verified parent-child relationship; do not merge as aliases. RO primary source is a2022report with six named authors. Helpers retain supporting-source roles.
Evidence: 5. Source location: Source byline, historical affiliation, SM1 and NRC report cover/Table7-9; role-specific CLIC helpers
Evidence: 5. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 6. Origin: editor_verification
Evidence: 6. Target field: methodology_notes
Evidence: 6. Qualification: Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Evidence: 6. Source location: SM1 Tables2–6 and five embedded EMF figures; pinned later compiler Final specifications/lci
Evidence: 6. Source reference: https://ars.els-cdn.com/content/image/1-s2.0-S2352152X21004874-mmc1.docx
Evidence: 7. Origin: editor_verification
Evidence: 7. Target field: technology_description
Evidence: 7. Qualification: Technical-characterisation review TC-2068. Design capacity: 1.000000. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 7. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 7. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 8. Origin: editor_verification
Evidence: 8. Target field: technology_description
Evidence: 8. Qualification: Technical-characterisation review TC-2068. Design capacity unit: MW. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 8. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 8. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 9. Origin: editor_verification
Evidence: 9. Target field: technology_description
Evidence: 9. Qualification: Technical-characterisation review TC-2068. Capacity factor (%): Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 9. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 9. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 10. Origin: editor_verification
Evidence: 10. Target field: technology_description
Evidence: 10. Qualification: Technical-characterisation review TC-2068. Annual production volume: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 10. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 10. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 11. Origin: editor_verification
Evidence: 11. Target field: technology_description
Evidence: 11. Qualification: Technical-characterisation review TC-2068. Annual production volume unit: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 11. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 11. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 12. Origin: editor_verification
Evidence: 12. Target field: technology_description
Evidence: 12. Qualification: Technical-characterisation review TC-2068. Annual production volume year: Unspecified. Basis: No new current-context value established for this reference; no source/consumer parameter is transferred automatically. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 12. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 12. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 13. Origin: editor_verification
Evidence: 13. Target field: technology_description
Evidence: 13. Qualification: Technical-characterisation review TC-2068. Plant or represented-asset lifetime (years): Unspecified. Basis: Single-component manufacture and whole-system operating life are different scopes. Existing source/current lifetime wording must be reconciled before transferring a consumer system or stack lifetime to this record. Evidence classification: exact asset or service scope review. Confidence: high for model role not industrial performance. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 13. Source location: Final specifications rows4/6/12and exact companion operation allocations; electrolysis-source-reading.json
Evidence: 13. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 14. Origin: editor_verification
Evidence: 14. Target field: technology_description
Evidence: 14. Qualification: Technical-characterisation review TC-2068. Commercial maturity stage: early_commercial. Basis: Retain early-commercial/TRL8as a qualified curator route estimate for SOEC, supported by contemporary industrial demonstration context. This is not a manufacturer/source-assigned numeric TRL for the exact1 MW model or validation of steam/pressure interfaces and durability. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 14. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 14. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 15. Origin: editor_verification
Evidence: 15. Target field: technology_description
Evidence: 15. Qualification: Technical-characterisation review TC-2068. Technology readiness level: 8. Basis: Retain early-commercial/TRL8as a qualified curator route estimate for SOEC, supported by contemporary industrial demonstration context. This is not a manufacturer/source-assigned numeric TRL for the exact1 MW model or validation of steam/pressure interfaces and durability. Evidence classification: current source scope and curator route or proxy assessment. Confidence: explicit unresolved route vs exact model classification. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 15. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 15. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 16. Origin: editor_verification
Evidence: 16. Target field: technology_description
Evidence: 16. Qualification: Technical-characterisation review TC-2068. Technological representativeness: 4. Basis: Curator assessment of a hybrid literature/compiler model with selected updated membrane/alloy/PCS/drive and utility assumptions. Established route maturity does not make exact bill and performance representative measured production. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 16. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 16. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 17. Origin: editor_verification
Evidence: 17. Target field: technology_description
Evidence: 17. Qualification: Technical-characterisation review TC-2068. Geographical representativeness: 3. Basis: Curator assessment of generic regional supplier/material references and scenario electricity choices, not a matched or production-weighted factory population. Selected supply scenarios do not independently establish equipment manufacturing geography. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 17. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 17. Source reference: https://doi.org/10.1016/j.est.2021.102759
Evidence: 18. Origin: editor_verification
Evidence: 18. Target field: technology_description
Evidence: 18. Qualification: Technical-characterisation review TC-2068. Temporal representativeness: 4. Basis: Curator assessment of mixed historical source materials, IndWEDe/manufacturer scenario assumptions and later compiler adaptations.2019/2030/2050electricity scenarios,2021publication and current equipment availability are not full-inventory observation periods. Evidence classification: current source scope and curator route or proxy assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan.
Evidence: 18. Source location: Publisher scope; compiler Final specifications/native current references; electrolysis-source-reading.json
Evidence: 18. Source reference: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Doi: 10.1016/j.est.2021.102759
Publications: 1. Url: https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Title: Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production
Publications: 1. Scientific authors: 1. Name: Niklas Gerloff
Publications: 1. Scientific authors: 1. Orcid: Not set
Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/00q7z2571
Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.est.tu-clausthal.de/
Publications: 1. Scientific authors: 1. Affiliations: 1. Name: Research Centre Energy Storage Technologies (EST), TU Clausthal, Am Stollen19A,38640Goslar,Germany
Publications: 1. Citation: Gerloff, N. (2021; online 9 October 2021). Comparative Life-Cycle-Assessment analysis of three major water electrolysis technologies while applying various energy scenarios for a greener hydrogen production. Journal of Energy Storage 43, 102759. https://doi.org/10.1016/j.est.2021.102759
Publications: 1. Relation: primary_source
Publications: 1. Source type: scientific_journal
Publications: 1. Publication year: 2021
Publications: 2. Doi: Not set
Publications: 2. Url: https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Title: Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland
Publications: 2. Scientific authors: 1. Name: Tom Smolinka
Publications: 2. Scientific authors: 1. Orcid: Not set
Publications: 2. Scientific authors: 2. Name: Nikolai Wiebe
Publications: 2. Scientific authors: 2. Orcid: Not set
Publications: 2. Scientific authors: 3. Name: Philip Sterchele
Publications: 2. Scientific authors: 3. Orcid: Not set
Publications: 2. Scientific authors: 4. Name: Andreas Palzer
Publications: 2. Scientific authors: 4. Orcid: Not set
Publications: 2. Scientific authors: 5. Name: Franz Lehner
Publications: 2. Scientific authors: 5. Orcid: Not set
Publications: 2. Scientific authors: 6. Name: Malte Jansen
Publications: 2. Scientific authors: 6. Orcid: Not set
Publications: 2. Scientific authors: 7. Name: Steffen Kiemel
Publications: 2. Scientific authors: 7. Orcid: Not set
Publications: 2. Scientific authors: 8. Name: Robert Miehe
Publications: 2. Scientific authors: 8. Orcid: Not set
Publications: 2. Scientific authors: 9. Name: Sylvia Wahren
Publications: 2. Scientific authors: 9. Orcid: Not set
Publications: 2. Scientific authors: 10. Name: Fabian Zimmermann
Publications: 2. Scientific authors: 10. Orcid: Not set
Publications: 2. Citation: Smolinka, T., Wiebe, N., Sterchele, P., Palzer, A., Lehner, F., Jansen, M., Kiemel, S., Miehe, R., Wahren, S., & Zimmermann, F. (30 October 2018). Studie IndWEDe – Kurzfassung: Industrialisierung der Wasserelektrolyse in Deutschland. NOW GmbH. https://www.now-gmbh.de/wp-content/uploads/2020/09/181127_bro_a4_indwede-studie_kurzfassung_de_v03.pdf
Publications: 2. Relation: supporting_source
Publications: 2. Source type: technical_report
Publications: 2. Publication year: 2018
Version metadata System boundary Foreground reference: 1 unit of electrolyzer, 1MWe, SOEC, Stack. The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy. Material/component supply, recorded forming services and assembly electricity for one SOEC stack. Hydrogen-production utilities, lifetime multiplication and the paired finished-equipment treatment are modelled separately.
Version metadata Technological representativeness 2 4
Version metadata Technology description Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack. SOEC stack represented by material supply, forming/processing and component purchases. This unit represents one manufactured component, separately from the operating model's lifetime purchases. Crofer-type interconnect, composition-specific YSZ/YDC oxides, nominal glass seal and LSM contact ceramic are supplied through separate engineering references.
Version metadata Temporal representativeness 2 4
Version metadata Limitations on use Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page. Source component quantities and estimated assembly energy do not establish a measured complete manufacturer bill of materials, actual industrial yield or equivalent supplier grades/performance. SM1 BoP energy totals follow approximately linear 1 MW scaling, despite the paragraph's 0.7 exponent; they are about 7.94 times a reconstruction using that exponent. Some component intensities may already be scaled. Original H2_generation and data_generation_material workbooks were not recovered, limiting exact reconstruction. Source La/Sr quantities are deferred to an unrecovered material-generation sheet; the 2.1 kg LSM reference does not prove older 21 kg precursor entries were decimal errors. Alloy, ceramic and glass manufacture are not a validated complete industrial stack BOM. Lanthanum-reject fate and fluoride/PFC/bath coverage remain unresolved, and native uncertain rolling makeup remains upstream.
Version metadata Description Gerloff (2021; online 9 October) compares 1 MWe AEC, PEM and SOEC systems using modeled component inventories and German 2019, 2030, 2050 and renewable-only electricity scenarios. The paper uses ecoinvent 3.5 cut-off, European or German suppliers where available, Umberto+ and ILCD 2.0 midpoint 2018, with IPCC 2013 for GWP. Oxygen is vented without a product credit. Publication and scenario dates do not date input measurements. This record supplies 1 unit of electrolyzer, 1MWe, SOEC, Stack.

The source assumes a 20-year system operating 8000 hours/year, a factor of 3 for stacks, two 250 km component transport legs and estimated manufacturing energy. Later CLIC records adapt manufacturer specifications, lifetimes and materials. The stack reference represents one manufactured unit; operating purchases and corresponding negative retirement are counted once. Source manufacturing estimates are not measured factory energy.

Preserve current source-specific backgrounds, biosphere profiles, attribution and published revisions. Source quantity agreement is not validation of pressure/purity, partial-load operation, metal allocation, ceramic chemistry, membrane grade, waste recovery or uncertainty. Main paper says three stack replacements but multiplies quantities by3; SM1 manufacturing totals also include3stacks. CLIC uses4purchases forPEM/AEC and8forSOEC with distinct adapted lifetimes. Current stack-unit manufacturing energy is source total/3; avoid applying replacement factors in both stack recipe and operating service. Preserve current coordinated choice pending lifetime-model review. Original SOEC figure defers La/Sr quantities to data_generation_material spreadsheet; it does not print21kg+21kg or validate2.1kgLSM. Current oxide mixtures, finished glass, Crofer, PFSA, reinforced diaphragm and PTFE gasket references are engineering adaptations with inherited performance and waste-treatment limits. SM1 Table3 stack energy includes three stacks; current single-stack recipes correctly use one third, with lifetime purchases handled separately. BOP Table3 totals instead follow near-linear1MW scaling despite the paragraph's0.7exponent: about7.94times its reconstruction. Component intensities may already be scaled. Preserve printed quantities while resolving this source-internal basis conflict. Retrieved IndWEDe is the Kurzfassung; Gerloff cites p178 of the unrecovered full report, so compiler-selected hours/lifetimes are not independently verified from that page.
Manufacturing reference for one stack of a nominal 1 MWe SOEC water electrolyzer. It combines source-model material quantities and assembly energy with later CLIC component and supplier adaptations. Use material-specific SOEC interconnect and ceramic references, and represent the seal as finished glass. The revision replaces generic steel, mixed rare-earth and precursor placeholders with the adopted component compositions and manufacturing boundaries. The description states the resulting reference flow, process boundary and remaining source limitations.
Version metadata Intended application Not set Provision of one SOEC electrolyzer stack in compatible operating or equipment scenarios with separate lifetime and retirement accounting. Apply reviewed discovery metadata and change explanations from the curated release.
Version metadata Name electrolyzer production, 1MWe, SOEC, Stack electrolyzer production, 1MWe, SOEC, stack Activity and product names now follow consistent catalogue spelling, so the intended inventory and its supplier references remain identifiable.
Review & discussion Publication provenance, scientific review and community discussion.
Public review record Curator-led bulk import. Public evidence is shown without participant accounts, assignments, recommendations, or private editor notes. Show review Hide review

Publication route

Curator-led bulk import

This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.

No public review transcript is available for this version.
Discussion 0 public comments · questions, context and problem reports.

Public discussion

Questions and comments are public. The dataset submitter is notified.

Log in to participate
No public comments yet. Start the discussion if you have a question about this inventory.
Report this dataset or version

Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.

Log in to report content