Description
Provision of one nominal 800 kWh stationary LFP buffer-battery reference.
Trucks and lorries
Reference product Storage battery RER
Stable dataset identity
storage-battery
1.0.1Published inventory
Process description and catalog context. View scientific metadata
Provision of one nominal 800 kWh stationary LFP buffer-battery reference.
Classification, keywords, bookmarks and download counts.
Classification path: Transport > Road transport > Trucks and lorries
Log in to bookmarkSource documentation, background profiles and references.
Other
Supporting sources:
Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0
Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf
These are the stored source profiles for this version. Foreground methodology is recorded in Scientific metadata.
Missing exchange uncertainty generation: Not requested
Representativeness scores use a 1–5 scale when provided. Lower scores indicate a closer fit to the modeled technology, geography, or time period.
Precalculated screening profile
Results per unit, using UVEK 2025 and the ecoinvent 3.10 biosphere. Exchange rows are shaded from green to red by relative contribution to the selected indicator.
This screening result uses Brightpath mappings from the source background to UVEK 2025; mapped suppliers are not claims of scientific equivalence.
Profile uvek-2025-ef-v3-1-4e70d56a85b1 · artifact
4e70d56a85b1 · calculated
2026-11-03 09:20 UTC. These screening results do not replace a reviewed comparative LCA.
Outputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
storage battery
RER
|
Storage battery
|
1
|
unit | Reference flow |
Inputs
| Exchange | Reference / categories | Amount | Unit | Metadata | Climate change contribution |
|---|---|---|---|---|---|
|
electricity storage capacity
|
800
|
kilowatt hour |
642.563
mol H+-Eq / unit
99.9% of total
38773.1
kg CO2-Eq / unit
99.6% of total
557405
CTUe / unit
99.9% of total
171.841
kg P-Eq / unit
100.0% of total
100.574
kg N-Eq / unit
99.8% of total
449.394
mol N-Eq / unit
99.6% of total
-0.000130489
CTUh / unit
100.0% of total
0.0075337
CTUh / unit
100.0% of total
10920.2
kBq U235-Eq / unit
99.9% of total
188208
dimensionless / unit
99.7% of total
0.000563566
kg CFC-11-Eq / unit
99.2% of total
0.00211346
disease incidence / unit
99.8% of total
62.1499
kg NMVOC-Eq / unit
98.8% of total
361025
MJ, net calorific value / unit
99.4% of total
4.13172
kg Sb-Eq / unit
100.0% of total
187293
m3 world Eq deprived / unit
99.9% of total
|
||
|
market for transport, freight, lorry >32 metric ton, EURO6
RER
|
transport, freight, lorry >32 metric ton, EURO6
|
800
|
ton kilometer |
0.482365
mol H+-Eq / unit
0.1% of total
137.897
kg CO2-Eq / unit
0.4% of total
357.492
CTUe / unit
0.1% of total
0.0135104
kg P-Eq / unit
0.0% of total
0.180741
kg N-Eq / unit
0.2% of total
1.93816
mol N-Eq / unit
0.4% of total
4.9444e-08
CTUh / unit
0.0% of total
1.0894e-06
CTUh / unit
0.0% of total
16.125
kBq U235-Eq / unit
0.1% of total
605.489
dimensionless / unit
0.3% of total
4.7153e-06
kg CFC-11-Eq / unit
0.8% of total
4.1962e-06
disease incidence / unit
0.2% of total
0.774758
kg NMVOC-Eq / unit
1.2% of total
2019.67
MJ, net calorific value / unit
0.6% of total
0.000350154
kg Sb-Eq / unit
0.0% of total
175.861
m3 world Eq deprived / unit
0.1% of total
BAFU:2025
|
Read-only definitions preserved with this inventory version. Values are supplied by the source; CLIC does not evaluate formulas or recalculate exchange amounts and impact scores from them.
No parameter definitions were supplied with this inventory snapshot.
Direct technosphere and natural-resource inputs appear on the left; emissions appear on the right.
2 CLIC nodes and 1 background boundary node shown. Direct inputs appear to the left of the current dataset, while emissions appear to the right. Hover an arrow to inspect its amount and unit, click a blue supplier node to reveal up to three upstream steps, or click an emissions node to open its biosphere flows, then scroll or drag the canvas to navigate.
Reuse and provenance
Add this version to your basket, inspect original uploads, or reuse it in your LCA software.
Original source files are currently unavailable, but you can still add this version to your basket for generated package export.
Published versions are immutable and remain available.
Oldest to newest. Arrows show recorded revision links; each node describes the change introduced by that version.
First published inventory; no earlier version is available for comparison.
SupersededUses the documented storage battery reference: This dataset represents a stationary storage battery used as part of electric-vehicle charging infrastructure rather than as an…
Published · Viewing · Latest| Version | Published | Reason for this version | Link |
|---|---|---|---|
| Version 1.0.1 | 2026-11-03 | Uses the documented storage battery reference: This dataset represents a stationary storage battery used as part of electric-vehicle charging infrastructure rather than as an onboard traction battery. | Current view |
| Version 1.0.0 Superseded | Published 2026-07-15 | First published inventory; no earlier version is available for comparison. | Open version |
Uses the documented storage battery reference: This dataset represents a stationary storage battery used as part of electric-vehicle charging infrastructure rather than as an onboard traction battery.
Source reference: https://doi.org/10.1016/S0306-2619(01)00032-0.
Declared licence: CC BY 4.0. Source documents and external supplier inventories retain their own terms.
Uses the documented storage battery reference: This dataset represents a stationary storage battery used as part of electric-vehicle charging infrastructure rather than as an onboard traction battery.
This comparison is permanently visible with the published version so users can assess every detected change before reuse.
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for battery capacity, Li-ion, LFP, stationary (technosphere / GLO / kilowatt hour) | Amount | Not present | 800 kilowatt hour | Use the documented storage battery reference and its component boundary: This dataset represents a stationary storage battery used as part of electric-vehicle charging infrastructure rather than as an onboard traction battery. In the life-cycle analysis of EV charging infrastructure, the charger system includes supporting electrical equipment needed to buffer and manage power delivery, and this row captures that infrastructure-side storage function for truck charging. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| market for battery capacity, stationary (CONT scenario) (technosphere / GLO / kilowatt hour) | Amount | 800 kilowatt hour | Not present | Use the documented storage battery reference and its component boundary: CLIC A031 standalone storage revision: the existing 800 kWh capacity input now uses 100% stationary LFP supply from CLIC dataset 1435, not the former CONT technology mix. The 800 ton-kilometer transport input, capacity quantity, other assumptions and native profiles are unchanged. Historical charger-use attribution above is preserved as provenance; this revision does not reintroduce storage into corrected charger datasets 1622, 1623 or 2972. Supplier 1435 retains its existing capacity-to-mass conversion and treatment boundary. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| storage battery (production / RER / unit) | Name | Storage battery | storage battery | Standardized capitalization of the activity or product name. The amount, unit and other exchange fields are unchanged. |
| Exchange / scope | Field | Previous value | Revised value | Reason |
|---|---|---|---|---|
| Version metadata | Inventory evidence types | Literature | Engineering estimate | No explanation was recorded for this change. |
| Version metadata | Design capacity | 100.000000 | 800.000000 | |
| Version metadata | Design capacity unit | kW | kWh | |
| Version metadata | Geographical representativeness | 2 | 3 | |
| Version metadata | Intended application | Charging-infrastructure equipment reference for LCA, preserving the exact hardware/capacity/installation basis; not a direct delivered-electricity or vehicle-kilometre inventory. | Nominal buffer-capacity provision with the existing LFP supplier boundary. | |
| Version metadata | Methodology and allocation explanation | Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Storage is currently800kWh nominal LFP manufacturing-capacity demand, not800kWh delivered electricity and not a source4000kg lead-acid inventory. Historical CONT market is a different technology basket. Chemistry, mass/capacity transfer, service life, cycling and current supplier boundary need original stationary-battery evidence before changes. Freight800tkm would imply200km at the earlier4tonne mass; that does not certify the LFP system mass. | Chemistry and capacity are later engineering choices. The earlier charging paper's 4,000 kg lead-acid battery is historical ancestry, not this LFP recipe. Nominal manufacturing capacity, usable electricity and discharge power have different dimensions. | |
| Version metadata | Plant lifetime | 24 | Not set | |
| Version metadata | Source type | scientific_journal | other | |
| Version metadata | Contributors, publications, projects and supporting evidence | Evidence: 1. Origin: editor_verification Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Exact source/adaptation evidence; a battery component used in transport is included under the explicitly authorized battery-production exception. Vehicle and transport activities remain excluded. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: editor_verification Evidence: 2. Target field: data_origins Evidence: 2. Qualification: Exact source/adaptation evidence; a battery component used in transport is included under the explicitly authorized battery-production exception. Vehicle and transport activities remain excluded. Evidence: 2. Source location: description Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: editor_verification Evidence: 3. Target field: publications Evidence: 3. Qualification: Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers. Evidence: 3. Source location: DOI registration: title, publication dates and byline Evidence: 3. Source reference: https://api.crossref.org/works/10.1016%2FS0306-2619%2801%2900032-0 Evidence: 4. Origin: editor_verification Evidence: 4. Target field: publications Evidence: 4. Qualification: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Historical2001 affiliations are supported by NIES annual bibliography: Nansai/Moriguchi at NIES, Tohno/Kasahara at Kyoto University, Kono at Toshiba International Fuel Cells. Nansai's primary ORCID is0000-0002-2449-1874; other unverified identifiers remain blank. Kyoto University (02kpeqv85) is not its museum; NIES (02hw5fp67) is not the Environment Ministry. Toshiba International Fuel Cells is not automatically the parent Toshiba corporation. ABB E-mobility and generic ABB publisher roles remain separate and no unrelated ABB-acronym ROR is assigned. Evidence: 4. Source location: NIES2003 annual bibliography, printed106; byline and historical external affiliations Evidence: 4. Source reference: https://www.nies.go.jp/en/pr/publications/annual/ae-9-2003.pdf Evidence: 5. Origin: editor_verification Evidence: 5. Target field: methodology_notes Evidence: 5. Qualification: Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Storage is currently800kWh nominal LFP manufacturing-capacity demand, not800kWh delivered electricity and not a source4000kg lead-acid inventory. Historical CONT market is a different technology basket. Chemistry, mass/capacity transfer, service life, cycling and current supplier boundary need original stationary-battery evidence before changes. Freight800tkm would imply200km at the earlier4tonne mass; that does not certify the LFP system mass. Evidence: 5. Source location: Original source tables and frozen revision rationale Evidence: 5. Source reference: https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Evidence: 6. Origin: editor_verification Evidence: 6. Target field: funding Evidence: 6. Qualification: Primary2001 publisher acknowledgment identifies JSPS Research for the Future project Distributed Autonomous Urban Energy System for Mitigating Environmental Impact,JSPS-RFTF97P01002; recovered2000 paper independently prints the same award. Canonical JSPS (00hhkn466) differs from its London office (02m7axw05). NIES's B-55 research-topic classification is not an interchangeable grant number or proof of funding of later CLIC/ABB adaptations. No funding/project declarations are propagated to these adapters. Evidence: 6. Source location: 2000 printed281 acknowledgment;2001 publisher acknowledgment preview Evidence: 6. Source reference: https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Publications: 1. Doi: 10.1016/s0306-2619(01)00032-0 Publications: 1. Url: https://doi.org/10.1016/s0306-2619(01)00032-0 Publications: 1. Title: Life-cycle analysis of charging infrastructure for electric vehicles Publications: 1. Scientific authors: 1. Name: Keisuke Nansai Publications: 1. Scientific authors: 1. Orcid: 0000-0002-2449-1874 Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02hw5fp67 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.nies.go.jp/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: National Institute for Environmental Studies Publications: 1. Scientific authors: 2. Name: Susumu Tohno Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02kpeqv85 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.kyoto-u.ac.jp/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Kyoto University Publications: 1. Scientific authors: 3. Name: Motoki Kono Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Toshiba International Fuel Cells Publications: 1. Scientific authors: 4. Name: Mikio Kasahara Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02kpeqv85 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.kyoto-u.ac.jp/ Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Kyoto University Publications: 1. Scientific authors: 5. Name: Yuichi Moriguchi Publications: 1. Scientific authors: 5. Orcid: Not set Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02hw5fp67 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.nies.go.jp/ Publications: 1. Scientific authors: 5. Affiliations: 1. Name: National Institute for Environmental Studies Publications: 1. Citation: Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0 Publications: 1. Relation: supporting_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2001 Publications: 2. Doi: Not set Publications: 2. Url: https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Publications: 2. Title: Life Cycle Analysis of Charging Infrastructure for Electric Vehicles Publications: 2. Scientific authors: 1. Name: Keisuke Nansai Publications: 2. Scientific authors: 1. Orcid: 0000-0002-2449-1874 Publications: 2. Scientific authors: 2. Name: Motoki Kono Publications: 2. Scientific authors: 2. Orcid: Not set Publications: 2. Scientific authors: 3. Name: Susumu Tohno Publications: 2. Scientific authors: 3. Orcid: Not set Publications: 2. Scientific authors: 4. Name: Mikio Kasahara Publications: 2. Scientific authors: 4. Orcid: Not set Publications: 2. Scientific authors: 5. Name: Yuichi Moriguchi Publications: 2. Scientific authors: 5. Orcid: Not set Publications: 2. Citation: Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: scientific_journal Publications: 2. Publication year: 2000 |
Evidence: 1. Origin: editor_verification Evidence: 1. Target field: data_origins Evidence: 1. Qualification: Exact source/adaptation evidence; a battery component used in transport is included under the explicitly authorized battery-production exception. Vehicle and transport activities remain excluded. Evidence: 1. Source location: source Evidence: 1. Source reference: Existing published CLIC inventory documentation Evidence: 2. Origin: editor_verification Evidence: 2. Target field: data_origins Evidence: 2. Qualification: Exact source/adaptation evidence; a battery component used in transport is included under the explicitly authorized battery-production exception. Vehicle and transport activities remain excluded. Evidence: 2. Source location: description Evidence: 2. Source reference: Existing published CLIC inventory documentation Evidence: 3. Origin: editor_verification Evidence: 3. Target field: methodology_notes Evidence: 3. Qualification: Explicit declaration in this supplied inventory. Evidence: 3. Source location: source Evidence: 3. Source reference: Existing published CLIC inventory documentation Evidence: 4. Origin: editor_verification Evidence: 4. Target field: methodology_notes Evidence: 4. Qualification: Explicit declaration in this supplied inventory. Evidence: 4. Source location: description Evidence: 4. Source reference: Existing published CLIC inventory documentation Evidence: 5. Origin: editor_verification Evidence: 5. Target field: publications Evidence: 5. Qualification: Bibliographic details refer to this explicitly cited DOI. Existing citation text is retained, including any additional sources. Publication year does not establish the inventory reference year; publication authors are not assigned as inventory compilers. Evidence: 5. Source location: DOI registration: title, publication dates and byline Evidence: 5. Source reference: https://api.crossref.org/works/10.1016%2FS0306-2619%2801%2900032-0 Evidence: 6. Origin: editor_verification Evidence: 6. Target field: publications Evidence: 6. Qualification: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Historical2001 affiliations are supported by NIES annual bibliography: Nansai/Moriguchi at NIES, Tohno/Kasahara at Kyoto University, Kono at Toshiba International Fuel Cells. Nansai's primary ORCID is0000-0002-2449-1874; other unverified identifiers remain blank. Kyoto University (02kpeqv85) is not its museum; NIES (02hw5fp67) is not the Environment Ministry. Toshiba International Fuel Cells is not automatically the parent Toshiba corporation. ABB E-mobility and generic ABB publisher roles remain separate and no unrelated ABB-acronym ROR is assigned. Evidence: 6. Source location: NIES2003 annual bibliography, printed106; byline and historical external affiliations Evidence: 6. Source reference: https://www.nies.go.jp/en/pr/publications/annual/ae-9-2003.pdf Evidence: 7. Origin: editor_verification Evidence: 7. Target field: methodology_notes Evidence: 7. Qualification: Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Storage is currently800kWh nominal LFP manufacturing-capacity demand, not800kWh delivered electricity and not a source4000kg lead-acid inventory. Historical CONT market is a different technology basket. Chemistry, mass/capacity transfer, service life, cycling and current supplier boundary need original stationary-battery evidence before changes. Freight800tkm would imply200km at the earlier4tonne mass; that does not certify the LFP system mass. Evidence: 7. Source location: Original source tables and frozen revision rationale Evidence: 7. Source reference: https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Evidence: 8. Origin: editor_verification Evidence: 8. Target field: funding Evidence: 8. Qualification: Primary2001 publisher acknowledgment identifies JSPS Research for the Future project Distributed Autonomous Urban Energy System for Mitigating Environmental Impact,JSPS-RFTF97P01002; recovered2000 paper independently prints the same award. Canonical JSPS (00hhkn466) differs from its London office (02m7axw05). NIES's B-55 research-topic classification is not an interchangeable grant number or proof of funding of later CLIC/ABB adaptations. No funding/project declarations are propagated to these adapters. Evidence: 8. Source location: 2000 printed281 acknowledgment;2001 publisher acknowledgment preview Evidence: 8. Source reference: https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Evidence: 9. Origin: editor_verification Evidence: 9. Target field: technology_description Evidence: 9. Qualification: Technical-characterisation review TC-2969. Design capacity: 800.000000. Basis: Current own engineering equipment/capacity reference, not manufacturing-factory throughput, measured operating output, usable electricity or performance validation. Nominal model rating is explicitly retained with its source-transfer qualifications. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 9. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 9. Source reference: https://zenodo.org/records/23935622 Evidence: 10. Origin: editor_verification Evidence: 10. Target field: technology_description Evidence: 10. Qualification: Technical-characterisation review TC-2969. Design capacity unit: kWh. Basis: Current own engineering equipment/capacity reference, not manufacturing-factory throughput, measured operating output, usable electricity or performance validation. Nominal model rating is explicitly retained with its source-transfer qualifications. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 10. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 10. Source reference: https://zenodo.org/records/23935622 Evidence: 11. Origin: editor_verification Evidence: 11. Target field: technology_description Evidence: 11. Qualification: Technical-characterisation review TC-2969. Capacity factor (%): Unspecified. Basis: No additional own operating parameter established. Manufacturing/validity/revision dates, source scenario years, material retention and equipment rating do not establish annual observed output or plant capacity factor. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 11. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 11. Source reference: https://zenodo.org/records/23935622 Evidence: 12. Origin: editor_verification Evidence: 12. Target field: technology_description Evidence: 12. Qualification: Technical-characterisation review TC-2969. Annual production volume: Unspecified. Basis: No additional own operating parameter established. Manufacturing/validity/revision dates, source scenario years, material retention and equipment rating do not establish annual observed output or plant capacity factor. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 12. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 12. Source reference: https://zenodo.org/records/23935622 Evidence: 13. Origin: editor_verification Evidence: 13. Target field: technology_description Evidence: 13. Qualification: Technical-characterisation review TC-2969. Annual production volume unit: Unspecified. Basis: No additional own operating parameter established. Manufacturing/validity/revision dates, source scenario years, material retention and equipment rating do not establish annual observed output or plant capacity factor. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 13. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 13. Source reference: https://zenodo.org/records/23935622 Evidence: 14. Origin: editor_verification Evidence: 14. Target field: technology_description Evidence: 14. Qualification: Technical-characterisation review TC-2969. Annual production volume year: Unspecified. Basis: No additional own operating parameter established. Manufacturing/validity/revision dates, source scenario years, material retention and equipment rating do not establish annual observed output or plant capacity factor. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 14. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 14. Source reference: https://zenodo.org/records/23935622 Evidence: 15. Origin: editor_verification Evidence: 15. Target field: technology_description Evidence: 15. Qualification: Technical-characterisation review TC-2969. Plant or represented-asset lifetime (years): Unspecified. Basis: The current 800 kW h LFP adapter replaced historical lead-acid ancestry; inherited generic24-year charger life does not establish this buffer's own chemistry/system life. Preserve missing lifetime as a specific evidence question. Retain guarded current numeric values only in their explicitly identified device/model roles. Keep manufacture versus operation, installation versus hardware life, continuous/peak/input/output ratings, efficiency versus capacity factor, material yield and actual annual production distinct. Unsupported own fields remain unspecified; no factory throughput, operating observation year or additional calendar life inferred. Evidence classification: source parameter and exact reference scope review. Confidence: high for scoped source model values and explicit gaps. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 15. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 15. Source reference: https://zenodo.org/records/23935622 Evidence: 16. Origin: editor_verification Evidence: 16. Target field: technology_description Evidence: 16. Qualification: Technical-characterisation review TC-2969. Commercial maturity stage: early_commercial. Basis: Clear exact numerical readiness for this adapted model. Retain existing broad early-commercial classification only as qualified prior model context, not a source-assigned maturity assessment of the precise recipe. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 16. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 16. Source reference: https://zenodo.org/records/23935622 Evidence: 17. Origin: editor_verification Evidence: 17. Target field: technology_description Evidence: 17. Qualification: Technical-characterisation review TC-2969. Technology readiness level: Unspecified. Basis: Clear exact numerical readiness for this adapted model. Retain existing broad early-commercial classification only as qualified prior model context, not a source-assigned maturity assessment of the precise recipe. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 17. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 17. Source reference: https://zenodo.org/records/23935622 Evidence: 18. Origin: editor_verification Evidence: 18. Target field: technology_description Evidence: 18. Qualification: Technical-characterisation review TC-2969. Technological representativeness: 4. Basis: Curator technology/geography/time 4/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 18. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 18. Source reference: https://zenodo.org/records/23935622 Evidence: 19. Origin: editor_verification Evidence: 19. Target field: technology_description Evidence: 19. Qualification: Technical-characterisation review TC-2969. Geographical representativeness: 3. Basis: Curator technology/geography/time 4/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 19. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 19. Source reference: https://zenodo.org/records/23935622 Evidence: 20. Origin: editor_verification Evidence: 20. Target field: technology_description Evidence: 20. Qualification: Technical-characterisation review TC-2969. Temporal representativeness: 4. Basis: Curator technology/geography/time 4/3/4 for reconstructed geometry, material and integration scope, transferred suppliers and unresolved observation vintage. Preserve worse existing scores. Manufacturer edition, EPD date and source background release are not factory measurement or production years. Evidence classification: source scope and explicit curator assessment. Confidence: medium curator judgement. A retained model value is not a measured observation or industrial certification. Source-specific assumptions and detailed technical parameters accompany this plan. Evidence: 20. Source location: Exact current recipe and source/EPD/design/replacement reconstruction; variant-specific manufacturer documentation where recorded Evidence: 20. Source reference: https://zenodo.org/records/23935622 Publications: 1. Doi: 10.1016/s0306-2619(01)00032-0 Publications: 1. Url: https://doi.org/10.1016/s0306-2619(01)00032-0 Publications: 1. Title: Life-cycle analysis of charging infrastructure for electric vehicles Publications: 1. Scientific authors: 1. Name: Keisuke Nansai Publications: 1. Scientific authors: 1. Orcid: 0000-0002-2449-1874 Publications: 1. Scientific authors: 1. Affiliations: 1. Ror: https://ror.org/02hw5fp67 Publications: 1. Scientific authors: 1. Affiliations: 1. Url: https://www.nies.go.jp/ Publications: 1. Scientific authors: 1. Affiliations: 1. Name: National Institute for Environmental Studies Publications: 1. Scientific authors: 2. Name: Susumu Tohno Publications: 1. Scientific authors: 2. Orcid: Not set Publications: 1. Scientific authors: 2. Affiliations: 1. Ror: https://ror.org/02kpeqv85 Publications: 1. Scientific authors: 2. Affiliations: 1. Url: https://www.kyoto-u.ac.jp/ Publications: 1. Scientific authors: 2. Affiliations: 1. Name: Kyoto University Publications: 1. Scientific authors: 3. Name: Motoki Kono Publications: 1. Scientific authors: 3. Orcid: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Ror: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Url: Not set Publications: 1. Scientific authors: 3. Affiliations: 1. Name: Toshiba International Fuel Cells Publications: 1. Scientific authors: 4. Name: Mikio Kasahara Publications: 1. Scientific authors: 4. Orcid: Not set Publications: 1. Scientific authors: 4. Affiliations: 1. Ror: https://ror.org/02kpeqv85 Publications: 1. Scientific authors: 4. Affiliations: 1. Url: https://www.kyoto-u.ac.jp/ Publications: 1. Scientific authors: 4. Affiliations: 1. Name: Kyoto University Publications: 1. Scientific authors: 5. Name: Yuichi Moriguchi Publications: 1. Scientific authors: 5. Orcid: Not set Publications: 1. Scientific authors: 5. Affiliations: 1. Ror: https://ror.org/02hw5fp67 Publications: 1. Scientific authors: 5. Affiliations: 1. Url: https://www.nies.go.jp/ Publications: 1. Scientific authors: 5. Affiliations: 1. Name: National Institute for Environmental Studies Publications: 1. Citation: Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0 Publications: 1. Relation: supporting_source Publications: 1. Source type: scientific_journal Publications: 1. Publication year: 2001 Publications: 2. Doi: Not set Publications: 2. Url: https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Publications: 2. Title: Life Cycle Analysis of Charging Infrastructure for Electric Vehicles Publications: 2. Scientific authors: 1. Name: Keisuke Nansai Publications: 2. Scientific authors: 1. Orcid: 0000-0002-2449-1874 Publications: 2. Scientific authors: 2. Name: Motoki Kono Publications: 2. Scientific authors: 2. Orcid: Not set Publications: 2. Scientific authors: 3. Name: Susumu Tohno Publications: 2. Scientific authors: 3. Orcid: Not set Publications: 2. Scientific authors: 4. Name: Mikio Kasahara Publications: 2. Scientific authors: 4. Orcid: Not set Publications: 2. Scientific authors: 5. Name: Yuichi Moriguchi Publications: 2. Scientific authors: 5. Orcid: Not set Publications: 2. Citation: Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf Publications: 2. Relation: supporting_source Publications: 2. Source type: scientific_journal Publications: 2. Publication year: 2000 |
|
| Version metadata | System boundary | One stationary buffer-battery reference buying800kWh nominal manufacturing capacity and800tkm freight. Historical supply uses the CONT stationary-battery technology basket. This is a capacity/service adapter, with no direct operating-electricity delivery in the foreground. The earlier Nansai lead-acid battery is a historical source, not the current chemistry recipe. Component/reference-unit manufacturing or aggregate installation only, as specified above. Vehicle operation, grid electricity delivery, efficiency, utilization and pervehicle allocation require separate service models. |
Supplied battery-capacity reference and represented freight; charge/discharge operation, stationary system design and any additional replacement schedule require a separate consuming-system model. | |
| Version metadata | Technological representativeness | 2 | 4 | |
| Version metadata | Technology description | One stationary buffer-battery reference buying800kWh nominal manufacturing capacity and800tkm freight. Historical supply uses the CONT stationary-battery technology basket. This is a capacity/service adapter, with no direct operating-electricity delivery in the foreground. The earlier Nansai lead-acid battery is a historical source, not the current chemistry recipe. | The reference buys 800 kWh from the current stationary LFP capacity market and 800 tkm freight; it supplies no operating electricity directly. | |
| Version metadata | Technology readiness level | 8 | Not set | |
| Version metadata | Temporal representativeness | 3 | 4 | |
| Version metadata | Limitations on use | Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Historical200kW charger uses4.3 equivalents of the600kg component, consistent with2×1290/600. ABB's1290kg row is rated100kW, while PSI2023 Table70 calls it200kW; the retained coefficient therefore includes an additional factor2 relative to the report's literal mass wording. Historical450kW scaling is(3×1340+500)/600=7.533333333. Manufacturer masses do not establish linear electrical-power scaling or the2000 electronics fraction in modern hardware. Current4675 replaces the legacy charger/stand/buffer assembly with1.2 integrated200kW hardware equivalents, one foundation and negative retirement/packaging demands. Current4676 buys the separate450kW station and WEEE demand; it no longer buys the old stand or buffer battery. Preserve these documented equipment-only replacements, including absence of dedicated stationary storage; do not restore Nansai's battery or treat the vehicle-model2020 climate/cycle as this component's measurement year. Recovered ABB Terra184 PEP ABBG-00284-V01.01-EN was issuedJuly2023, with395kg180kW hardware,25kg packaging,458kg foundation and10year reference life. Its functional unit is1kWh supplied in the defined operating scenario, whereas CLIC hardware outputs one equipment unit. Do not import EPD use-phase electricity, headline impacts or lifetime denominator into component manufacture. Current200kW hardware scales Terra184 material masses by200/180, giving438.888889kg total,430kg assigned classes and8.888889kg unassigned miscellaneous material. Keep that gap visible instead of normalizing it away. Source steel197kg×200/180 is split between ordinary steel and a grade430 shell within the same budget. Shell geometry/grade, material providers, wood500kg/m3 density and backgrounds are compiler assumptions, not a manufacturer200kW BOM. Source percentages use the full878kg station reference; do not treat them as percentages of395kg hardware. Current200kW installation retains12/10=1.2 expected hardware equivalents: the hardware's10years is sourced, installation12years is an inherited assumption. Foundation450kg concrete plus8kg steel is purchased/retired once, with2400kg/m3 concrete. WEEE−526.666667kg excludes packaging; wood−29.333333kg and PE−4kg cover all deliveries once. Preserve negative waste-service signs, paired background profiles and absence of double-counted foundation steel. No discrete replacement timetable or recycling credit is inferred. ABB PantoUP RevB January2021 confirms450kW from three1340kg150kW cabinets,7inch service HMI, and a separate pole/interface specification. It lists45kg contact dome and500kg control-box/pole rows; whether500kg includes the dome is not established here. Current station's500kg support recipe,10m cable, one shared2kg industrial HMI/PLC and aggregate4613.576kg retirement are engineering assumptions, not a certified full station BOM. Do not add a second onboard pantograph to offboard infrastructure without checking callers. Current charger/stand retain generic-wrought aluminium50/1kg instead of AlLi, and the stand replaces one laptop/17inch screen with an industrial interface/controller. Five current predecessor/rationale hashes are verified. Do not reverse these corrections or infer that8.25kg grouped stand electronics includes the replaced computer/display. Historical recipes and later native zero-laptop entries remain distinct evidence. Storage is currently800kWh nominal LFP manufacturing-capacity demand, not800kWh delivered electricity and not a source4000kg lead-acid inventory. Historical CONT market is a different technology basket. Chemistry, mass/capacity transfer, service life, cycling and current supplier boundary need original stationary-battery evidence before changes. Freight800tkm would imply200km at the earlier4tonne mass; that does not certify the LFP system mass. Charger freight120tkm is consistent with600kg×200km. Stand36.05tkm would imply180.25kg at200km versus the earlier100kg total, or360.5km if100kg is retained. This is an unresolved source/functional mass-distance convention; no isolated numerical candidate is proposed. Preserved HMI/PLC changes and stationary-battery chemistry further complicate direct rescaling. Historical2001 affiliations are supported by NIES annual bibliography: Nansai/Moriguchi at NIES, Tohno/Kasahara at Kyoto University, Kono at Toshiba International Fuel Cells. Nansai's primary ORCID is0000-0002-2449-1874; other unverified identifiers remain blank. Kyoto University (02kpeqv85) is not its museum; NIES (02hw5fp67) is not the Environment Ministry. Toshiba International Fuel Cells is not automatically the parent Toshiba corporation. ABB E-mobility and generic ABB publisher roles remain separate and no unrelated ABB-acronym ROR is assigned. Primary2001 publisher acknowledgment identifies JSPS Research for the Future project Distributed Autonomous Urban Energy System for Mitigating Environmental Impact,JSPS-RFTF97P01002; recovered2000 paper independently prints the same award. Canonical JSPS (00hhkn466) differs from its London office (02m7axw05). NIES's B-55 research-topic classification is not an interchangeable grant number or proof of funding of later CLIC/ABB adaptations. No funding/project declarations are propagated to these adapters. Crossmark explicitly reports no available data for the2001 DOI, rather than current status. Scoped DOI/title/erratum/supplement searches locate no authoritative correction, amended supplement or retraction; full2001 text and any historic supplementary inventory remain unavailable locally. Earlier2000 original and2021/2023 manufacturer documents are different sources, not published corrections of2001. ABB PEP issue/revision and PantoUP revision are pinned; later product revisions do not automatically amend this frozen equipment model. |
Usable state-of-charge window, power, cycling, life and the LFP mass/transport relationship remain unverified. The inherited 100 kW and generic charger-life labels do not establish this battery's own parameters; upstream capacity/treatment responsibilities must be checked before adding replacement or retirement burdens. | |
| Version metadata | Description | One stationary buffer-battery reference buying800kWh nominal manufacturing capacity and800tkm freight. Historical supply uses the CONT stationary-battery technology basket. This is a capacity/service adapter, with no direct operating-electricity delivery in the foreground. The earlier Nansai lead-acid battery is a historical source, not the current chemistry recipe. Source roles and limits: Nansai2001 AppliedEnergy70(3),251–265 has five ordered authors: Keisuke Nansai, Susumu Tohno, Motoki Kono, Mikio Kasahara and Yuichi Moriguchi. The2000 Japanese original is separately recovered: authors place Kono before Tohno. Its Table3 is an earlier numerical comparator, not proof that every2001 table is identical. Do not replace2001 date/byline with2000 or confuse server upload2021 with publication year. Earlier2000 Table3, printed277/PDF4, lists600kg charger: iron400, copper80, aluminium50 and70kg grouped electronics. Stand100kg comprises iron73, copper11, aluminium1, computer4.5, card reader1.5, display2.25 and other6.75. Stationary lead-acid storage4000kg includes lead2400kg and560kg30percent sulfuric-acid solution. These are not measured stainless18/8, AlLi, industrial HMI/PLC or LFP compositions. Storage is currently800kWh nominal LFP manufacturing-capacity demand, not800kWh delivered electricity and not a source4000kg lead-acid inventory. Historical CONT market is a different technology basket. Chemistry, mass/capacity transfer, service life, cycling and current supplier boundary need original stationary-battery evidence before changes. Freight800tkm would imply200km at the earlier4tonne mass; that does not certify the LFP system mass. |
Provision of one nominal 800 kWh stationary LFP buffer-battery reference. | Describe the actual reference flow, process boundary, engineering assumptions and source limitations in reader-facing language. Remove operational review/release instructions and distinguish capacity/component services from operating-energy inputs; the inventory content and declared terms are preserved. |
| Version metadata | Name | Storage battery | storage battery | Standardized capitalization; the dataset identity and reference basis are retained. |
| Version metadata | Source | Supporting sources: Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0; Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf | Supporting sources: Nansai, K.; Tohno, S.; Kono, M.; Kasahara, M.; Moriguchi, Y. (2001). Life-cycle analysis of charging infrastructure for electric vehicles. Applied Energy70(3),251–265. https://doi.org/10.1016/s0306-2619(01)00032-0 Nansai, K.; Kono, M.; Tohno, S.; Kasahara, M.; Moriguchi, Y. (2000). Life Cycle Analysis of Charging Infrastructure for Electric Vehicles. Energy and Resources21(3),274–281. https://www.jser.gr.jp/wp-content/uploads/2021/02/21-274.pdf |
Document the actual vehicle model/component recipe, its source publication and operating/proxy assumptions, keeping source attribution distinct from changes to physical exchange quantities. |
Publication route
This inventory was restored from a public CLIC archive. Its original publication route is Curator-led bulk import; private review and workflow records were not transferred.
Use this form to report a problem with this dataset or version. To report an individual public comment, use “Report this comment” beside that comment. To propose better numerical inventory data, use “Suggest an inventory improvement” in the inventory section.
Log in to report content